}

Design, Construction And Retrofitting Of Piped Water Supply Schemes Under Jal Jeevan Mission At Villages -1.Niwaniya, 2.Achalukhedi, 3.Karnakhedi, 4.Hoshyarkhedi , Block Dewas, Distt.Dewas Based On Tube Wells Including Providing And Installation Of Subme, dewas-Madhya Pradesh

Public Health Engineering Department-PHED has published Design, Construction And Retrofitting Of Piped Water Supply Schemes Under Jal Jeevan Mission At Villages -1.Niwaniya, 2.Achalukhedi, 3.Karnakhedi, 4.Hoshyarkhedi , Block Dewas, Distt.Dewas Based On Tube Wells Including Providing And Installation Of Subme. Submission Date for this Tender is 22-09-2022. Water Pipe Line Tenders in dewas Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33961234
Design, Construction And Retrofitting Of Piped Water Supply Schemes Under Jal Jeevan Mission At Villages -1.Niwaniya, 2.Achalukhedi, 3.Karnakhedi, 4.Hoshyarkhedi , Block Dewas, Distt.Dewas Based On Tube Wells Including Providing And Installation Of Subme
Open Tender
Indian
Madhya Pradesh
dewas
22-09-2022

Tender Details

Design, Construction And Retrofitting Of Piped Water Supply Schemes Under Jal Jeevan Mission At Villages -1.Niwaniya, 2.Achalukhedi, 3.Karnakhedi, 4.Hoshyarkhedi , Block Dewas, Distt.Dewas Based On Tube Wells Including Providing And Installation Of Submersible Motor Pumps, Pump Houses , Construction Of Rcc Oht’S And Sumpwells, Providing, Laying And Jointing Of Rising Main And Distribution Pipe Line System, Household Tap Connections, Electric Power Connections At Tube Wells / Sumpwells Etc. Including Cost Of All Material And Labour With Testing Commissioning And Thereafter 90 Days Of Successful Trial Run Of Entire Schemes.

Key Value

Document Fees
INR 15000 /-
EMD
INR 239250.0 /-
Tender Value
INR 2.39 Crore /-

BOQ Items

Name of Work:
Sl. No. Item Description
1Design, Construction and Retrofitting of Piped Water Supply Schemes under Jal Jeevan Mission at Villages -1.Niwaniya,2.Achalukhedi,3.Karnakhedi,4.Hoshyarkhedi ,Block Dewas,Distt.Dewas based on Tube wells including providing and installation of submersible motor pumps, pump houses ,construction of RCC OHT’s and Sumpwells, providing, laying and jointing of rising main and distribution pipe line system, household tap connections, electric power connections at tube wells/Sumpwells etc. including cost of all material and labour with testing commissioning and thereafter 90 Days of successful Trial Run of entire schemes.
2Fabrication, providing and fixing of typical information board of size 2.40 m x 1.80 m made out as detailed below 1. Three vertical support made out from 100 mm x 50 mm , 6.0 mm thick channel. This shall be minimum 1.0 m below GL and 3.00 m above GL. The Channel shall be erected on 600 mm x 600 mm x 1000 mm foundation blocks at appropriate depth made of cement concrete 1:2:4. 2.The board shall be fabricated from 1.6 mm thick MS sheet of size 2.40 m x 1.80 m, The frame of board shall be fabricated with 50 mm x 50 mm x 5 thick angle with one horizontal additional support in center with same angle. 3. Whole structure shall be painted by standard color with lettering border, heading and logo etc using synthetic enamel paint of superior quality including welding, excavation, concreting , painting of base, border and lettering, painting and other required details etc complete as directed by Engineer in charge II Amdt USOR 17.47 P-7
3Cutting of Water Bound Machadam road and making good the same including supply of extra quantities of materials i.e aggregates,moorum,screening and labour required.USOR.Item.no. 16.21- P.no. 166
4Installation of HDPEpipe by Horizontal Direction Drilling Method including preparing and setting up the plant and equipment , making string of new pipe material, installing new pipe string and making the system ready for commissioning by HDD operation including drilling, stringing,reaming and pulling back the new pipe on the designed bore path alignment , proper disposal of drilling fluid, as per code of practice for horizontal direction drilling technique suiting Indian conditions. Required pipes/specials and other civil work shall be paid separately - In all types of soils.HDPE pipes of any class 90 mm outer dia.USOR.Item.no. 16.3- P.no. 207
5Earth work in Excavation for pipe trench in all kinds of soil and WBM in areas including dressing, watering and ramming and disposal of Excavated earth lead upto 50 meters and lift upto 1.5m, disposal earth to be leveled, neatly dressed.USOR. Item.no. 16.4 -P.no.207 (a)
6Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. Soft rock with or without blasting or bituminous pavement / cement concrete road In ordinary or Soft rock with or without blasting or bituminous pavement / cement concrete road. Hard rock (requiring blasting.) USOR.Item.no. 16.6-(b) P.no.208
7Demolishing cement concrete manually / by mechanical means including disposal of material within 50 m lead as per direction of engineer-in- charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) USOR. Item.no.16.15.1-P.no.209
8Providing & laying mechanically mixed cement concrete 20mm nominal size graded crushed stone excluding cost of centering & shuttering. 1:3:6 (M-10) . USOR.Item.no. 16.23 a(i)-P.no.210
9Providing & laying mechanically mixed cement concrete 20mm nominal size graded crushed stone excluding cost of centering & shuttering. 1:2:4 (M-15) . USOR.Item.no. 16.23 a (ii)-P.no.210
10Providing, Laying, Jointing & field Itesting of PE pipes made from 100% lvirgin material (Earlier know as High lDensity Polyethylene pipes, PE 100 ) lconfirming to IS 498414151/ 12786/13488 with necessary jointing material llike mechanical connector of jointing pipes by heating to the ends of pipes with the help of Tellon coated electric lmirror/ heater to the required temperature and then mechanically pressing the ends together against each othero to form a monolithic & leak proof joint by thermosetting process. It] may be required to be done with Jack/Hydraulic Jacks/ Butt fusion machine. (50 mm & above fusion jointed & below 50mm mechanical jointed)as per USOR 6 th Amend. Item.no. 9.1 -P.no.9 ,90 mm dia PE 10 Kg/cm²
11Providing, Laying, Jointing & field Itesting of PE pipes made from 100% lvirgin material (Earlier know as High lDensity Polyethylene pipes, PE 100 ) lconfirming to IS 498414151/ 12786/13488 with necessary jointing material llike mechanical connector of jointing pipes by heating to the ends of pipes with the help of Tellon coated electric lmirror/ heater to the required temperature and then mechanically pressing the ends together against each othero to form a monolithic & leak proof joint by thermosetting process. It] may be required to be done with Jack/Hydraulic Jacks/ Butt fusion machine. (50 mm & above fusion jointed & below 50mm mechanical jointed)as per USOR 6 th Amend. Item.no. 9.1 -P.no.9 , 90 mm dia PE 6 Kg/cm²
12Providing, Laying, Jointing & field Itesting of PE pipes made from 100% lvirgin material (Earlier know as High lDensity Polyethylene pipes, PE 100 ) lconfirming to IS 498414151/ 12786/13488 with necessary jointing material llike mechanical connector of jointing pipes by heating to the ends of pipes with the help of Tellon coated electric lmirror/ heater to the required temperature and then mechanically pressing the ends together against each othero to form a monolithic & leak proof joint by thermosetting process. It] may be required to be done with Jack/Hydraulic Jacks/ Butt fusion machine. (50 mm & above fusion jointed & below 50mm mechanical jointed)as per USOR 6 th Amend. Item.no. 9.1 -P.no.9, 110 mm dia PE 6 Kg/cm²
13Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy ncluding testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part- II 50mm diamedium class for lowering of motor pump in T.W.USOR.Item.no. 6.1P. No.86-87-USOR.Item.no. 6.2P. No.87
14Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy ncluding testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part- II 65mm dia medium class for lowering of motor pump in sumpUSOR.Item.no. 6.1P. No.86-87-USOR.Item.no. 6.2P. No.87
15Providing & fixing of following Ductile iron double flanged sluice valves as per I.S.:14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete, PN 10, 80mm dia, USOR 4.41 D- 71
16Providing & fixing of following Ductile iron double flanged sluice valves as per I.S.:14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete, PN 10,100 mm dia, USOR 4.41 D- 71
17Providing & fixing following cast iron double flanged single door reflux (non return) valves including jointing & testing with cost of jointing material such as bolts,nuts and rubber insertion all complete as per IS :5312 (Part I) class PN 1.0 80 MM Dia USOR 8.4 a P-113
18Providing and laying including testing Bend 90° confirming to IS specifications.USOR. 6 th Amend. Item.no. 9.2 -P.no.9.90mm dia 10 kg/sq.cm
19Providing and laying including testing Bend 90° confirming to IS specifications.USOR. 6 th Amend. Item.no. 9.2 -P.no.9.90mm dia 6 kg/sq.cm
20Providing and laying including testing Bend 90° confirming to IS specifications.USOR. 6 th Amend. Item.no. 9.2 -P.no.9110 mm dia 6 kg/sq.cm
21Providing and laying Bend 45° confirming to IS specifications. USOR. 6 th Amend. Item.no. 9.3 -P.no.10 90mm dia 10 kg/sq.cm
22PProviding and laying Bend 45° confirming to IS specifications. USOR. 6 th Amend. Item.no. 9.3 -P.no.10 90mm dia 6 kg/sq.cm
23Providing and laying Bend 45° confirming to IS specifications. USOR. 6 th Amend. Item.no. 9.3 -P.no.10 110mm dia 6 kg/sq.cm
24Providing and laying equal tee confirming to IS specifications. USOR.6 th Amend. Item.no. 9.4 -P.no.10 90 mm dia 10 kg/sq.cm
25Providing and laying equal tee confirming to IS specifications. USOR.6 th Amend. Item.no. 9.4 -P.no.10 90 mm dia 6 kg/sq.cm
26Providing and laying equal tee confirming to IS specifications. USOR.6 th Amend. Item.no. 9.4 -P.no.10 110 mm dia 6 kg/sq.cm
27Providing and laying pipe end confirming to IS specifications.USOR.6 th Amend. Item.no. 9.5 -P.no.10 90 mm dia 10 kg/sq.cm
28Providing and laying pipe end confirming to IS specifications.USOR.6 th Amend. Item.no. 9.5 -P.no.10 90 mm dia 6 kg/sq.cm
29Providing and laying pipe end confirming to IS specifications.USOR.6 th Amend. Item.no. 9.5 -P.no.10 110 mm dia 6 kg/sq.cm
30Providing and laying reducer confirming to IS specifications.USOR.6 th Amend. Item.no. 9.6 -P.no.11 110 mm dia 6 kg/sq.cm
31Supply & Filling moorum for pipe bedding or over the pipe ( including supply of moorum ) PHE USOR Item 16.11a Page 208
32Providing and laying including testing End Cap confirming to IS specifications.USOR.6 th Amend. Item.no. 9.8 -P.no.12,90 mm dia 6 kg/sq.cm
33Providing & Supply of Electro Fusion Fittings in accordance with BS EN 12201 : Part-3 suitable for drinking water with in black/blue color manufactured from compounded PE80/PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rated SDR 11 with min PN 12.5 rated for water application and shall be inclusive of all cost such as testing, all taxes related to central state & municipal, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. complete. Electro Fusion Coupler 90mmUSOR.6 th Amend.Item no. 9.14.1.8- P.no.16
34Providing & Supply of Electro Fusion Fittings in accordance with BS EN 12201 : Part-3 suitable for drinking water with in black/blue color manufactured from compounded PE80/PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure ratedSDR 11 with min PN 12.5 rated for water application and shall be inclusive of all cost such as testing, all taxes related to central state & municipal, inspection charges, transportation up to site, transit insurance, loading, unloading, stacking etc. complete.Electro Fusion Coupler 110mm , USOR.6 th Amend. Item no.9.14.1.9 -P.no.16
35Provision for Jointing of TW to Rising Main with cost of Material/ specials such as GI Union / CI Flange, GI Reducer UPVC MTA FTA etc. as per requiement of site i/c cost of labour etc. complete as per approved specification and as directed by Engineer in charge USOR 17.19 P 228
36Provision for jointing of Rising main to sump well/OHT and OHT to Distribution pipe line with cost of material/specials such as Bends, MTA as per rerquirement of site i/c cost of labour with excavation, labour as per requirement complete as per approved specification and as directed by Engineer in charge.USOR 17.20 P-229
37Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm with - Heavy Duty SFRC chamber cover with frame size 130cm x 100cm x 10cm including cost of materials, labour etc. complete. USOR item no. 17.46.2, Amdt Page no 7)
38Filling available excavated earth in trenches, plinth Filling available excavated earth in trenches, lead up to 50m and lift up to 1.5m in all kind of soil excluding watering and ramming.. USOR.Item.no.16.10 (b)-P.no. 208
39Fabrication of M.S. pipes & specials from steel plates as per relevant IS specifications inclusive of cost of all materials, for any thickness as per design, inspection charges, testing, transit insurance, loading/ unloading, FOR site and stacking etc. complete as per direction of the Engineer in charge. fabricating of pipes and specials from steel plates .USOR.Item.no. 10.2 P - 137
40Labour only for lowering and laying of MS pipe and specials as per approved specification complete as directed by Engineer incharge,USOR.Item.no. 10.3 P - 138
41Providing and applying primer and one coat of red oxide externally, USOR.Item.no. 10.3 P - 138
42Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items. For connection with 20 mm dia MDPE pipe upto 5 meter and CONCRETE ROAD CROSSING is necessary.USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020Item.no.17.41.1 -P.no. 4
43Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items. For connection with 20 mm dia MDPE pipe more than 5 meter & upto 10 meter and CONCRETE ROAD CROSSING isnecessary..USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020Item.no.17.41.2 -P.no. 4
44Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items , For connection with 20 mm dia MDPE pipe upto 5 meter and road crossing is not required. (Distribution pipe line is on the same side of house) .USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020Item.no.17.41.3 -P.no. 5
45Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items . For connection with 20 mm dia MDPE pipe upto 5 meter and road (OTHER THAN CONCRETE ROAD) crossing isnecessary..USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020Item.no.17.41.4 -P.no. 5
46Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items. For connection with 20 mm dia MDPE pipe more than 5 meter & upto 10 meter and road (OTHER THAN CONCRETE ROAD)crossing isnecessary.USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020Item.no.17.41.5 -P.no. 5
47Design, drawing, construction, testing and commissioning of Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS codes and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meter staging height from GL :- (26.5.10 50 Kilo Litres 12 MTR STAGINGUSOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020 USOR 26.1.7 P 14
48Design, drawing, construction, testing and commissioning of Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS codes and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meter staging height from GL :- (26.5.10 75 Kilo Litres 15 MTR STAGINGUSOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020 USOR 26.1.7 P 14
49Design, drawing, construction, testing and commissioning of GSR/Sumpwell of following capacities with all necessary fitting and accessories as mentioned in the relevant chapter of USOR, IS codes and departmental circulars. Complete turn key job for following capacities :- 40 Kilo Litres USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020USOR 26.2 P 17
50Design, drawing, construction, testing and commissioning of GSR/Sumpwell of following capacities with all necessary fitting and accessories as mentioned in the relevant chapter of USOR, IS codes and departmental circulars. Complete turn key job for following capacities :- 20 Kilo Litres USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020USOR 26.2 P 17
51Design and Construction of RCC framed brick masonry pump house over the sump with all necessary fitting and requirement as mentioned in relevant chapter of USOR, IS codes and departmental guidelines. Complete turn key job. This item will only be used with item no 26.2 only in cases where pumphouse to be constructed above the proposed sumpwell.USOR 2nd ADDENDUMOF Issued vide order no. 254 dt 06.08.2020 USOR 26.3 P 18
52Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) - All kinds of soil.MPPWD SOR Item 2.6 page 13
53Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. - Ordinary rock MPPWD SOR Item 2.7.1 page 13
54Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete. Thermo-Mechanically Treated bars.(TMT) MPPWD SOR Item 5.16.6 page 79
55Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering, finishing and reinforcement : M 20 -Grade ConcreteMPPWD SOR Item 5.2.1 page 75
56Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc.up to plinth level. MPPWD SOR Item 5.9 page 76
57Lintels, beams, girders, bressumers and cantilevers. - Coping sides MPPWD SOR Item 5.9.5 page 77
58Foundations, footings, bases of columns, etc. for concrete up to plinth level.MPPWD SOR Item 5.9.1 page 76
59Columns, Pillars, Piers, Abutments, Posts and Struts.MPPWD SOR Item 5.9.6 page 77
60Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :With 20mm nominal size graded stone aggregate.Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate (M 10) MPPWD SOR Item 4.1.1.4 page 38
61Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters,columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor two level, excluding the cost of centering, shuttering and finishing : With 20mm nominal size graded stone aggregate.M 20 - Grade concrete - Coping MPPWD SOR Item 4.2.1.2 page 39
62Brick work with well brunt open bhatta, bricks, crushing strength not less than 25kg / cm2 and water absorpt ion not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete.Cement Mortar 1:6 (1 cement : 6 sand)MPPWD SOR Item 6.6.2 page 109
6312 mm cement plaster of mix :1:6 (1 cement : 6 sand) MPPWD SOR Item 13.1.2 page 397
64Finishing walls by any mechanical or manual means with Acrylic Smooth exterior paint (Economy Exterior) of required shade including all scaffolding. New work ( Two or more coat applied @ 1.67 ltr/10 sqm over and including one coat undiluted exterior waterproofing coating @ 2.39 litre/10 sqm with crack bridging ability of upto 0.5 mm on horizontal surfaces with an elongation of 150 % and water proofing of upto 3 bars on vertical surface. MPPWD SOR Item 13.52 page 405
65Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. MPPWD SOR Item 2.25 page 18
66Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.MPPWD SOR Item 10.2 page 278
67Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. MPPWD SOR Item 13.69.1 page 408
68Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. . MP PWD SOR No. 11.66 P. NO. 325
69Supply, delivery, erection and commissioning of the micro processor based water disinfection equipment using silver ionization process based on Oligodynamic technology as per detailed specifications mentioned in the NIT, 10000 LPH capacity.Rates as per CE PHED Indore Zone indore Letter No. 160 Dt 25.07.2020
70Supply, delivery, erection and commissioning of the micro processor based water disinfection equipment using silver ionization process based on Oligodynamic technology as per detailed specifications mentioned in the NIT, 5000 LPH capacity.Rates as per CE PHED Indore Zone indore Letter No. 160 Dt 25.07.2020
71Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, deep-well submersible pump Steel body, suitable for 6"tube well with control Panel Starter suitable for Submersible pump with dry run protection (Auto cut-ofl), single phase preventer, connections, including clamps, bore cap, flat cable of length equals to maximum head of the pump plus 5 metres etc. as required as per specifications but excluding riser pipe and connection cable. l0 H.P. with 20 stages, head Mt.184-80Discharge LpM,60-270.USOR 6th Amendment Item.no. 24.20.106 (ix) P.no.42
72Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections, etc. as required as per specifications but excluding pipe and connection cable. II 3.0 H.P. Head Mt.15-24, Discharge LPM 615-195, USOR.Item.no. 24.20.113 P.no.268
73Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, centrifugal mono block pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections ,basechannel foundationetc. as required as per specifications but excluding pipe and connection cable.7.5 H.P. Head Mt.24-37, Discharge LPM 780-320, USOR.Item.no. 24.20.112 iii P.no.268
74Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.4.0 Sq.mm.multi strand USOR 24.20.107 P-207
75Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.. USOR.Item.no. 24.20.107 P - 267 6.0 Sq.mm.multi strand
76Providing and installation of automatic water level indicator for supervisory control cum auto on/off of motor pump assembly inclusive of control panel ,500 mtr long 2 core, 4 pair cable for small rural water supply scheme, having source within 500mtr as per approved specification and as directed by Engineer in charge. (In case of lesser length of cable,equivalent amount @ Rs 12 /- per meter of short length will be deducted from above rate) USOR. Item.no. 17.11.-P.no. 226
77Providing and installation of automatic water level indicator for supervisory control cum auto on/off panel of motor pump assembly, using GSM module based water level controller and accessories for small water supply scheme, having source more than 500mtr but within 10 Kms as per approved specification and as directed by Engineer in charge. USOR. Item.no. 17.12.-P.no. 226
78Supply & erection of readymade mini pump house (control panel box) GI sheet of 18 gauge of size 90cmx90cm x60cm with 40x40x5mm angle Iron frame to fix it 200mm below ground level with hold fasts grouted in foundation and 300mm above ground level for clearance suitable for fixing of control panel, fuse unit, main switch etc. as per approved specification.USOR item 17.18, P - 227
79Steel work in welded built-up section/ framed work, including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder , railings, brackets, gates and similar works USOR 16.25 P- 212
80Supplying and filling in plinth with crusher stone dust / coarse sand under floors including, watering, ramming and compacting in layers not exceeding.20cm in depth and dressing complete Note: - Maximum thickness of this layer shall be 20 cm. PWD SOR I.No. 2.26/P.No.29
81Fabrication, supply & erection of 5m high Mild Steel (MS) staging structure including foundation and 2x5 KL polyethylene tank with inlet, outlet and over flow pipe fittings complete Item of Work as per details given in the relevant chapter of USOR, enclosed drawings and relevant IS codes and direction of Engineer-in Charge. The approximate weight of the MS staging structure excluding tank, Gl pipe and Gl pipe fitting is 2050 kg. Complete tumkey job.USOR2nd Amendment Item.no. 26.6P.no28
82Providing, placing and installation of polyethylene water tankISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and the base support for tank on tenace (at all floor level).USOR2nd Amendment Item.no. 17.36 P.no3
83Supplying & Installation of Energy efficiant Five star rating ISI Marked required. capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6", tube well with Control Panel Starter suitable for Submersible pump with dry run protection (Auto cut-ofl), connections, including clamps, bore cap, flat cable of length equals to maximum head of the pump plus 5 meters etc. as required as per specifications but excluding riser pipe,SS/ Nylon wire rope and connection cable. 3 H.P. with 20 to 22 srages, Head Mt,167-51 Dischaige LpM 25-90 USOR 6th Amendment Item.no. 24.20.105(xviii) P.no 40
84Providing and supplying of HDPE pipes in 300/500/600 mtr. coils or in length ,Grade PE 100 Conforming to ISl4984-2016 store or at site (without copper wire) 40 mm Dia 10 kg/Cm² USOR 5th Amendment Item.no. 9.9 P.no 1
85Supplying and laying of approved Make Nylon rope12mm thick complete with binding for support of pump and motor USORItem.no. 24.20.108P.no267
86Providing and fixing G.l chain link fabric fencing of required width in mesh size 25 x 25 mm made of G.l wire of dia. 3 mm including strengthening with 2 mm dia. Wire or nuts, bolts and washer as required complete with posts of angle iron size 50x50x5mm 2.5 meter apart and strut of required size including bottom to be split and band at right angle in opposite direction for l0 cm length and drilling holes upto l0 mm dia and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix l:2:4 (l cement:2 sand : 4) graded stone aggregate 40 mm nominal size) every 15th post,last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineering charge. USOR 5th Amendment Item.no. 17.35 P.no3
87Providing and laying factory made machine pressed precast cement concrete interlocking paver block of any shape and size conforming to IS:15658- 2006 and ISI marked of 60 mm thickness, M-30 grade with grey cement and pigment all as specified. Made by block making machine with strong vibratory compaction, laid in required colour and pattern over and including 50mm thick compacted bed of stone dust, filling the joints with sand etc. all complete as per the direction of Engineer-in-Charge. . MP PWD SOR No. 11.66 P. NO. 325
8811 KV line on 140 kg. 8.0 Mtrs. long PCC Poles with rabbit conductor average span of 70 mtr. in rural area including labour complete. (Schedule Ref. C-1.2 of MPMKVVCL for SOR 2021-22)
8911 KV D.P. Structures on 140 kg. 8.0 mtr. long PCC poles for tapping DP including labour complete. (Schedule Ref. C-5.2 of MPMKVVCL for SOR 2021-22)
90L.T. Line 1 phase 3 wire on PCC support using Aerail Bunched XLPE cable with maximum span of 50 Meter including labour complete. 2 x 35+ 1 x 16 sq. mm (Insulated nuetral massenger)(Schedule Ref. D-2.2 of MPMKVVCL for SOR 2021-22)
9111/0.4 KV out-door type transformer sub-station. 25 KVA on 140 kg. 8.0 meter long PCC Pole including labour complete.(Schedule Ref. E-1.1of MPMKVVCL for SOR 2021-22)
92Fabrication, Providing and fixing of typical information board of size 1.50mX0.90m made out as detailed below - l.Tow vertical support (post) made out from ISA angle 50.X50X6mm this shall be minimum 0.75m below GL and 2.25m above GL. The vertical post shall be erracted on 450mmX450mmXl000mm foundation blocks (250mm above GL and 750mm below GL) made of cement concrete 1:2:4. 2. The board shall be fabricated from l.6mm thick MS sheet of size 1.50mX0.90m, The frame of board shall be fabricated with angle ISA 40X40X6 cross member support from"behind and flat 20X5mm support all around board. 3. Whole structure shall be painted by standard color with lettering, border, heading, and logo etc using synthetic enamel paint of superior quality including supply, welding, excavation, concreting, painting of base, border and lettering, painting and other required details etc complete as directed by Engineer in charge.USOR 6th Amendment item 17.48, P - 32
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail