Special Repairs To Jcos Md Accn Bldg No P- 201 / 01 To 04 At O / L, Eme School, Vadodara As Per Boq, baroda-Gujarat

Military Engineer Services-MES has published Special Repairs To Jcos Md Accn Bldg No P- 201 / 01 To 04 At O / L, Eme School, Vadodara As Per Boq. Submission Date for this Tender is 28-09-2022. Building Work Tenders in baroda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

33757771
Corrigendum : Special Repairs To Jcos Md Accn Bldg No P- 201 / 01 To 04 At O / L, Eme School, Vadodara As Per Boq
Open Tender
Indian
Gujarat
baroda
28-09-2022

Tender Details

Special Repairs To Jcos Md Accn Bldg No P- 201 / 01 To 04 At O / L, Eme School, Vadodara As Per Boq

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Sep-2022 Change in BOQ BOQ 21-09-2022
2 21-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 77600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: SPECIAL REPAIRS TO JCOS MD ACCN BLDG NO P- 201/01 TO 04 AT O/L, EME SCHOOL, VADODARA.
Sl. No. Item Description
1Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar.
2Roughening of old unservicable PCC floorsurface by picking, chipping and wire brush sweeping clean and washing down with water to remove dust outside and make it suitable for laying floor tile
3M&L fornon skid coloured ceramictile 7 to 8 mm thick, joint free area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm , as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalent of pigment matching to tile colorincluding screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:6 (Tile pattern and decoration may be as suggested by Engineer-in-charge)
4M&L fornon skid coloured ceramictile 7 to 8 mm thick joint free, area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm , as in floors etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalent of pigment matching to tile colorincluding screed bed or bedding layer of mortar 15 mm thick for laying floor finishes withCM 1:6 (Tile pattern and decoration may be as suggested by Engineer-in-charge)
5M&L fornon skid coloured ceramictile 7 to 8 mm thick,joint free area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm , as in skirting/dado etc set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementious grout manufactured by somani ezy grout or equivalent of pigment matching to tile color as in vertical serfaces of wall over and including 10 mm thick backing coat withCM 1:4 to receive wall tiles (Tile pattern and decoration may be as suggested by Engineer-in-charge)
6M & L for Glazed ceramic coloured walls tilesin vertical surfaces 350x 250x 6 mm to 7mm/ 450X 300X 6mm to 7mm thick set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color as in vertical serfaces of wall over and including 10 mm thick backing coat withCM 1:4 to receive wall tiles (Tile pattern and decoration may be as suggested by Engineer-in-charge)
7M & L for 18 to 20 mm thick machine cut green marble stone in single piece in riser of steps, skirting, dado, window (Jambs/Cills), and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 10 mm thick plastering with cement mortar 1 : 4 complete all as specified
8M & L for 18 to 20 mm thick machine cut green marble stone as in flooring, in steps in single piece laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick screed bed with cement mortar 1 : 6 complete all as specified
9M & L for machine cut kota stone slab flooring 20 - 25mm thick set over and including high performence adhesive manufactured by somani ezifix tile adhesive or equivalentmixed in cement as per manufacturer instructionand jointed with polymer modified cementious grout manufactured by somani ezy grout laid over and including 15 mm thick cement screed inCM 1:6 all as specified and as directed.
10Demolition of cement concrete as in Roofs,floors(otherthan ground floors), beams, staircases, landing, chajjas, chullah hood and similar suspended work
11M&L for Plain cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges.
12Taking down cement plaster on brick/concrete surface including raking out joints hacking for key scrubbing down with water etc.
13Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc,
14M&L for Brickwork with sub class ‘B’ old size bricks straight or curved on plan exc 6 mmean radius built in CM 1:6
15M & L for brickwork with sub class ‘B’ old size bricks straight or curved on plan exc 6 mmean radiusin half brick thick walls builtin CM 1:4
16M&L for Rendering 15 mm thick onfair faces of brick work or concrete surfaces of wall in cement mortar 1:6 finished even and smooth (without using extra cement)
17M&L for Rendering 15 mm thick in two layer onfair faces of brick work or concrete sur-faces of wall, 5 mm thick in CM 1:4 mixed with WPC@ 3% by wt of cement finished even and smooth without using extra cement over 10 mm thick rendering incement mortar 1:6 (WPC will be measured and paid separately).
18M&L for Rendering 10 mm thick onfair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:4 finished even and smooth (without using extra cement)
19Supply only Integral water proofing compound all as specified and directed.
20M & L for preparingnew plastered surfaces of wall and applying two coats of oil bound distemper over and includinga coat of 2mm averagethickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed.
21M & L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distemper over a coat of 2mm averagethickness birla/ equivalent wall care putty and one coat of primer all as specified and as directed.
22M& L for complete removal of existing treatment on wall surface andapplying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces.
23M& L for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
24M & L for preparing new plastered surfaces of ceiling and applying three coats of white wash.
25M & L for preparing old plastered surfaces of ceiling and applying two coats of white wash on ceiling .
26Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each
27Taking down chowkats or frame with shutter (without taking off shutter from the frame) exc 1.5 Sq m but n.exc 4.00 Sq m each
28M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick ,veneered on both side with decorative choice laminate type 1 (factory laminated),including 6mm thickexternal teak wood lipping fixed with nails, color and pattern as approved by EIC/GE.
29S & F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut ,mitred andmoulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats.
30M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/PVC door frame with screw complete all as specified and directed.
31S & F200mm long Aluminium anodised barrel tower bolt of extruded section and fixed
32S & F 150 mm size extruded aluminium alloy handles, fabricated type anodised
33S & F 300 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters
34S & F solidPVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade.The door frame shall be tied to the wall using 75/100mm long MS screw as directed .
35S & F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tube of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheetto be fitted in the MS frame welded/ sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete all as specified and directed.
36Providing and fixing factory made 18(+0.7mm) thick PVC sheet one sided pre laminated sheetcabinet shutter. 18 mm(+0.7mm) thk sheetshutter of density 600 kg/m3 bent at 90o and finished all edges at all level for making edges, Lipping/bending or 0.5 mm thk PVC sheet lipping at all four edges using bonding tape and fixed with magnet catcher etc complete all as per directions of enginer in Charge, Manufacturers"s speciifcations.
37S & F SSHinges SS 202 Grade steel RustResistance , for fixing cup board shutters sizes of hinges 3" to 4" and 1.5 mm thickness, suitable for 18 mm thick cabinets shutters complete all as specified and directed
38S & F 40 mm dia cupboard knobs fixed with nut, screw and washer of mild steel, bright finished supplied and fixed.
39S & F 125 mm aluminium alloy handles,cast type anodised all as specified.
40S & F 150mm aluminium anodised barrel tower bolts of extruded section and fixed.
41S & F in repairs 25mm dia stainless steel 202 grade tubular curtain rod as directed
42S & F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be approved by GE/AGE at the time of execution) as directed
43S&F of Powder coated aluminiumframe (Thickness of powder coating minimum 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
44S&F of Powder coated aluminium window/ventilator shutters,(Thickness of powder coating minimum 50 micron) side hung/sliding type including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws etc as per manufactures instruction & trade pactice
45S&F 4.00mm thick sheet glass, ordinary quality and glazing with rubber beading or with glazing clips, all as specified and directed.
46S&F 4.00mm thick figuredglass, pin head typeand glazing with rubber beading or with glazing clips, all as specified and directed.
47S&Fstainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.
48S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
49M & L for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate to fix hold fast complete all as specified and directed.
50M & L for preparing newsteel surface of any description not otherwise described over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of red oxide primer.
51M & L for preparing newwoodensurface of any description not otherwise described over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer.
52Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
53S & F16 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
54S & F 15mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
55Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
56Refixing of old galvanised mild steel medium grade of dia 20mm bore tubing and connections in new or old position with all new fittings and fixed complete to walls and ceilings or laid in floors all as directed.
57S & F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
58Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land all as directed by Engr-in-Charge.
59S & F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as directed.
60Dismantling cast iron pipes, jointed in cement mortar for 100 mm bore
61S & F 110mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wallall as specified and as directed.
62S & F 110mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed.
63S & F in repairs 110mm bore PVC (SWR) bends any radius all as specified and as directed.
64Dismantling cast iron pipes, jointed in cement mortar for 75 mm bore
65S & F 75mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wallall as specified and as directed.
66S & F 75mm borePVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorall as specified and as directed.
67S & F in repairs 75mm bore PVC (SWR) bends any radius all as specified and as directed.
68S & F 110mm PVC (SWR) vent cowl all as specified and as directed
69S & F 75mm PVC (SWR) vent cowl all as specified and as directed
70S & F 110mm PVC (SWR) WC connector with lip ring all as specified and as directed.
71S & F 110mm PVC (SWR) WC connector bent type to fit WC outlet all as specified and as directed.
72S & F 110mm PVC (SWR) junction single, (Single T, "Y" type) equal or unequal all as specified and as directed.
73S & F 75mm PVC (SWR) junction single, (Single, "Y" type T) equal or unequal all as specified and as directed.
74S & F stack clamps made out of 50mm X 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 110mm bore pipe all as specified and as directed
75S & F stack clamps made out of 50mm X 5mm flat iron and 16mm dia round iron stays incliding bolts and nuts and securing ends of stays to walls and roofs for 75mm bore pipe all as specified and as directed
76S & F in repair 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent all as specified and as directed.
77M & L PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement
78S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt, flushing cistern and flush pipe) complete all as specifed and directed.
79S&F plastic water closet seat, black and white closed pattern with flat bottom and cover and mild steel chromium plated plated or aluminium hinging device complete all as specifed and directed.
80S & F in repairs 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule
81S & F in repair CP wall mixer three in one system for mixing hot and cold wather screwed down for iron pipe 15 mm bore and fixed complete all as specified and directed.
82S & F in repairs stop valves/Angle valve15mm bore fancy type chromium plated screwed both ends for iron pipe or for unions and fixed
83S & F in repairs 25mm dia bore gun-metal,globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed
84S & F 125mm dia chromium plated shower rose with swivel joints including fixing to GI union complete
85S & F in repairs 20mm dia brass chrom plated tubular towel rail complete.
86S&F 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waste pipe
87Dismantling of water storage tank of 500 ltrs capacity.
88S & F 1000 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified and as directed.
89S & F in repairs Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed
90S&F in repair vitreous china Wash hand basin, white, bowel type size 550x400 mm except taps, CP waste coupling but incl brackets all as specified.
91Supply and fixing CP Centre hole Wash Basin mixerTwo in One 15 mm borecomplet all as specified.
92S & F 32 mm dia stainless steel waste coupling for wash hand basin all as specified and directed. Make : Prayag or equivalant.
93S & F PVC connections 15mm size with PTMT nuts of length 450mm
94S & F 600mm x 450mm bevelled edge mirror of selected quality glass, 5mm thick mounted on 6mm thick AC building board and around aluminium lipping fixed to wooden plugs with chromium plated brass screws and cup washers .
95S & F Stainless steel sink with drainage board, made out of 1.00mm thick sheet for kitchenwith plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm including suitable waste coupling and waste pipe.
96Supply & Fix of stainless steel wall mounted plate rack of size 900x1200X 300 mm and thickness of sheet not less than 0.50mm with provn for keeping plates and other crockeryfixed with screw and rawal plug etc on wall complete all as specified and as directed
97M & L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection,chajja,fins,facia, roof bands etc and making good with PCC (1:11/2; :3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in anyposition finished the surface even and smooth with out using extra cement including necessary form work and welding/binding of reinforcement (including reinforcement)if required complete and applying three coat of white wash/two coat of cement base pintto match with the existing surface as directed by the Engr- in -Charge . (Reiforcement will be measured and paid saperately under respective item.
98Repairsby brushing of treatment to reinforcement by application of corrrosion resisting coat in two coats, suitable time to be provided between coats according to manufacturers instructions to resist further deteroriation of reinforcement etccomplete according to intruction of eng- in - charge. Make Fosroc/piditlite or equivalent
99Repairs byapplication of approved epoxy based bond coat on concrete surfaces or sound bonding of cold and new concrete surfaces according to instructions of engineer in chargeMake Fosroc/ pidilite or equivalent
100Making of profile of structral memebers with polymer modified mortar in damaged areas 1:3(Cement:sand) mortar with 5 -10percentage addition of latex polymer,w/c ratio of0.35 in 20 mm thklayers / including leveling etc complete . Make Fosroc/ Pidilite or equivalemt
101M&L for Providing precast cement concrete Type B-1(1:2) using 20 mm aggregate, set in CM 1:6 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to matchcomplete all as specified and directed. (reinforcement shall be measured and paid separately)
102M&L for Providing reinforced cement concrete (nominal mix)Type B0(1:2:4) using 12.50 mm aggregateinSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed. Note. (reinforcement shall be measured and paid separately)
103M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specifed and as directed.
104M&L for complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris/rubbish out side MD land complete all as specified and directed by Engr-In-Charge
105M&L for 50 mm avg thick PCC padding in cement concrete type B1 (1:2:4) using 20 mm graded stone aggr with water proofing compound @2% by weight of cement finished surface even and smooth without using extra cement for laying of WPT all as specified and directed. (Note :- WPC will be measured and paid separately).
106M&L for 10 mmthick plaster on roof surface with CM 1:3 mixed with water proofing compound @3% by weight of cement plaster surface should be even and smooth without using extra cement all as directed. ( Note :-WPC will be measured and paid separately).
107M&L for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum75 mm side overlaps and minimum 100 mm end overlaps complete all as specified and directed by Engr-In-Charge
108M & L for brushing with neat cement slurry @ 3Kg/Sqm
109M & L for Cement concrete tiles 25cm x 25cm x 22-25mm thick with grey cement and pigments, machine pressed; laid over 15mm thick cement screed in CM 1:6, set, jointed and pointed in neat cement slurry with WPC@ 3% by wt of cement in floors/roof top complete all as specified and directed(WPC will be measured and paid separately).
110M & L forcutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3complete all as specified and directed
111M & L forFramed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed
112Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thickness (below or above ground level)
113M & L for 75 mm thick PCC 1:3:6mix type C2 as in plinth protection and paving finishing cone surface even and smooth without using extra cement
114M & L for Forming 65mm deep x 10mm thick contraction (dummy joints), filled with sealing compound grade "A".
115Taking down shutter exc 1 Sqm but n.exc 2 Sqm each
116M&L for floor door stopper of aluminium body complete all as specified and as directed.
117S & F in repairs Chromium plated soap dish heavy duty fixed with brass screw complete all as directed.
118S & F in repairs aluminum door seal of suitablesection fixed to door shutter with screw complete all as specified.
119Supply & fix in repair glass corner shelf assembly fancy type made of 6 to 7 mm thick sheet glass of size 250x 250mm fixed with CP brackets complete all as specified and directed.
120S & F in repair of sheet glass shelf assembly consisting of 5.5 mm thick sheet glass self 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as directed.
121S & F in repair of chromium plated hand shower (Health faucet) 15mm dia 1 mtr longtube acrylic type complete all as directed.
122S&F in repairs PVC flushing cistren low level, 10 ltr capacity with syphonic action type ball valve. Incl inlet ball valve,PVC band 32mm complete all as specified.
123M&L for sunken treatment of WC/Bath with polymeric membrance (APP based) with non woven polyster mat as reinforcement including water tightness test with filling of water for continuous 48 hours as under:-
124Demolition of existing PCC /lean concrete including floor tiles and removing rubbish off the premises.
125M&L for 15 mmthick plaster in sunken portion with CM 1:3 mixed with water proofing compound @3% by weight of cement plaster surface should be even and smooth without using extra cement all as directed. Note . (WPC will be measured and paid separately).
126M&L for water Proofing treatment to sunken floor slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum75 mm side overlaps and minimum 100 mm end overlaps complete all as specified and directed by Engr-In-Charge
127M&L for filling sunken portion with leanconcrete 1:5:10 using brick/lime aggregate and finish the surfaces rough to receive sub base complete all as specified and as directed.
128M & L for 25 mm thick cement concrete in flooring type B0, 1:2:4 (12.5mm graded aggregate) with water proofing compound @3% by weight of cementfor laying floor tiles. Note (WPC will be measured and paid separately).
129M & L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
130Taking down carefully existingunserviceable copper/aluminiumpoint wiring (light, fan, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), and making good disturbedsurface of wall, floors, etc complete all asdirected by Eng-in-Charge.
131M & L for Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVCConduit and all accessoriesConcealedinwalls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:-
132One light point controlled by one switch.
133One ceiling fan point controlled by one switch and fan regulator.
134One exhaust fan point controlled by one switch.
135One bell point controlled by one bell push
136One 3 pin socket outlet 5 Amps independent board.
137One 3 pin socket outlet 5 Amps on the same board with other switch.
138One light point controlled by two Nos two way switches
139All as per item No. 126 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket.
140S & F for switch piano flush type SP one way 6 Amp.
141S & F for switch piano flush flush type SP two way 6 amp
142S & F for Bell push, flush type, 5 amp
143S & F for switch socket combination 2 in 1, 3 pin, 6 and 16 amp flush typeuniversal.
144S & F for switch socket combination 2 in in 1, 6 A flush type.
145S & F for Socket outlet 2 in 1 , 3 pin, 6 Amps flush type.
146S & F ceiling rose surface polycarbonate body three terminal.
147S & F LED lamp 9W, 230V,AC, 50Hzsingle phase including backlite batten holder and lamp with all fitting fixing accessoriescomplete all as specified and directed.
148S & F stepped type electronic fan regulator flush type on the laminated sheet complete.
149S & F of ceiling fan complete with blades, down rod from existing roof / truss to false ceiling, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed. Note :1) Old ceiling fans shall be deposited to AGE E/M store yard.
150S & F Bell, AC, 230 volts, single pole complete all as specified and directed
151Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc. complete all as specified and directed. Note : Old electric water heater shall be deposited to AGE E/M store yard .
152Supply and fix LED light fitting 1X20Watt, 220 Volt AC decorative box type with drivers, holders and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable existing light fitting complete all as specified and directed.
153Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable existing light fitting complete all as specified and directed.
154S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete including taking down old unserviceable existing light fitting complete including taking down old unserviceable existing light fitting complete all as specified and directed.
155Supply and fix exhaust fan made of sturdy engineering Plasticcomplete with louvers shutter, voltage 230V, 50Hz, RPM 1200, copper winding of sweep 300mm including cutting of suitable size holes on existing wall and making good disturbed work to match the existing surfaces and exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in Charge. Note : Old exhaust fans shall be deposited to AGE E/M store yard
156M&L for Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694 marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
157S & F in repair MCB DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V completeall as directed by Engr-incharge.
158S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 ampsrated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed
159S & F incl connecting MCB single pole,having rupturing 10KA,6 amps to 32 amps as ordered 240 Volts
160S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 40 amps as ordered.
161S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240 V 63 amps as ordered.
162Supply and fix electronic meters tamper proof LCD display with polycarbonate cover 230 V, 10-60Amp, acuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH complete including PVC transparent suitable size meter box and taking down old unserviceable meter complete all as specified and directed Note : Old meter shall be deposited to AGE E/M store yard etc.
163S & F in repair LED street light coolwhitefitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers completecomplete all as specified and directed by Engr-in-Charge. (highly efficient LED street light made of pressure die cast aluminium housing with high power LEDs, Lens & toughened glass, IP66
164Taking down existing earthing and M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
165Excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes,pierholes etc and getting out in soft/loose soil complete
166Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete
167Returning filling in excavated approved soil including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil completed all as specified and directed
168Supply and laying dry fine sand of best available quality sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying, punned all as specified complete all as specified and directed. Note:- .Punned thickness shall be measured and paid.
169M & L Sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks as protection cover of cable laid, complete all as specified and directed.
170Supply and laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulatedaluminium conductor servedwithan innersheathing of PVC tape armoured with galvanised steel wire or tape andoverallPVC sheathed 25 sq. mm 4 Core nominal cross section in service connections.
171M&L for galvanized steel tubing light Grade of 40 mm dia for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
172Supply and laying in trenches of GI steel tubing 50 mm bore of pipe medium grade including all fittings such as Tees, elbow, bends etc complete all as specified.
173Supply and laying in trenches of GI steel tubing 20 mm bore of pipe medium grade including all fittings such as Tees, elbow, bends etc complete all as specified.
174S & F 50 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
175S & F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe.
176M & L for cutting existing steel tubing for alterations or additions (Each cut measured) for inserting new Tee, bend, elbow etc up to 50 mm dia