}

Repairs And Maintenance Of Various Summer Cooling Appliances Including Rewiring And Replacement Of Internal Electrical Accessories To Various Otm And Md Accn At Nahan Under Ge Chandigarh- 1 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, So, Chandigarh-Chandigarh

Military Engineer Services-MES has published Repairs And Maintenance Of Various Summer Cooling Appliances Including Rewiring And Replacement Of Internal Electrical Accessories To Various Otm And Md Accn At Nahan Under Ge Chandigarh- 1 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, So. Submission Date for this Tender is 10-09-2022. Spare Part Tenders in Chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

33523280
Corrigendum : Repairs And Maintenance Of Various Summer Cooling Appliances Including Rewiring And Replacement Of Internal Electrical Accessories To Various Otm And Md Accn At Nahan Under Ge Chandigarh- 1 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, So
Open Tender
Indian
Chandigarh
Chandigarh
10-09-2022

Tender Details

Repairs And Maintenance Of Various Summer Cooling Appliances Including Rewiring And Replacement Of Internal Electrical Accessories To Various Otm And Md Accn At Nahan Under Ge Chandigarh- 1 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Socket Or Power ) Complete, Including , Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc.Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit For Above Items Should Be Made As Per Conditions Separately ) And Making Good Disturbed Surfaces Of Walls, Floors, Etc. All As Specified And Directed. 2 Taking Down Mccb Incomer Db / Mcb Db / Ac Box / Meter Box / Junction Box Of Any Size And Disposal Under Schedule Of Credit And Making Good Disturbed Surfaces All As Specified And Directed. 3 Taking Downold Unserviceable Light Fittings Any Type And Removal From Site And Making Good Disturbed Surfaces Of Walls, Ceiling Etc Complete All As Specified And Directed By Engineer-In-Charge To Match With Existing Surface All As Directed. 4 M&Lfor Point Wiring Using Approved Colour Coding As Per Is ( For Phase And Neutral ) With Copper Conductor1.5 Sqmm ( Cross Sectional Area ) Single Core Multistrandedfrls , Pvcinsulated And Unsheathed Cable 1100 Volts Grade, Conforming To Is Drawnand Including Pvcconcealed Coduitwith Fittings Isi Marked , Terminated In Modular Switch Boxes Incl 1.5 Sqmm ( Cross Sectional Area ) Single Core , Multistranded , Frls Pvc Insulated And Sheathed Cable As Earth Continuity Conductorconnected To Earth Dolly For One Light Point Control By One Way Switch Complete All As Specified And Directed. Note: 1.Colour Code Of Wiring Should Be ( For Phase , Red, Neutral , Black & Earth Wire Green ) 2.Modular Switch Sockets Fan Regulators Shall Be Measured And Paid Separately Under Respective Items Deemed To Be Included In The Quoted Rates. 5 - Ditto - All As Per Item No - 4 Above But Controlled By Two Way Switch. 6 - Ditto - All As Per Item No - 4 Above But For One Ceiling Fan / Wall Fan / Exhaust Fan Point. 7 - Ditto - All As Per Item No - 4 Above But One Call Point Controlled By One Bell Point. 8 - Ditto - All As Per Item No - 4 Above But For One 3 Pin 5 Amp Socket On Same Board All As Directed. 9 - Ditto - All As Per Item No - 4 Above But For One 3 Pin 5 Amp Socket On Indipendant Board All As Directed. 10 - Ditto - As Per Item No4 Here In Before Butwith 4 Sqmm Copper Conductor For 15 Amp Socket With 2.5 Sqmm Earth Continuity Conductor 11 S&F Sub Main Wiring With Pvcinsulated, Frlscable 2 Single Core 6 Sq Mm 1100 V Grade With Stranded Copper Conductor On And Inclpvc Rigid Non Metalic Conduit ( Isi Marked ) In Concealedincl All Specials Like Joint, Elbow , Tee , Junction , Bend Etc And Provision Of Pvc Insulated Copper Conductor Single Core 4 Sq Mm For Earth Continuity Conductor Including Taking Out / Dismantling Unsv Sub Main Wiring Complete All As Directed By Enginer-In-Charge. 12 All As Per Item No 11 Here In Before But 2 Run Of 4 Sqmm And One Run Of 2.5 Sqmm Earth Contuinity Conductor 13 All As Per Item No-11Above But 2 Single Core 1.5 Sq Mm, One Single Core 1.0 Sq Mm For Earth Continuity Conductor Complete All As Directed By Enginer-In-Charge . 14 S&F Ofmodular Snap Switch Sp One Way 5 / 6 Amps Suitable For 1 Module Complete All As Specified And Directed. 15 S&F In Replacement Ofmodular Snap Switch Sp Two Way 5 / 6 Amps Suitable For 1 Module Complete All As Specified And Directed. 16 S&F Ofmodular Bell Push Switch, Sp One Way 5 / 6 Amps Suitable For 1 Module Complete All As Specified And Directed. 17 S&F Of Modular Socket 5 Pin 5 / 6 Amps Suitable For 2 Module Complete All As Specified And Directed. 18 S&F Of Modular Snap Switch Sp One Way 15 / 16 Amps Suitable For 1 Module Complete All As Specifiedand Directed. 19 S&Fofmodular Socket 5 / 6 Pin 15 / 16 Amps Suitable For 2 Module Complete All As Specifiedand Directed. 20 S&F Of Modular Fan Step Regulator Electronic, 120 Watts, 2 Module Complete All As Specifiedand Directed. 21 S&F Of Modular Blanking Plate Suitable For 1 Module Complete All As Specifiedand Directed. 22 Supply And Fixingof Modular Indicator Lamp, 2 Module Size Complete All As Directed. 23 S&F Of Modular White Cover Plate Incl Modular Baseframe & Powder Coated Modularsheet Metal Concealed Box For 12 / 8 Module Complete All As Specifiedand Directed. 24 All As Per Item No-23 Above But 6 / 4 Module Complete All As Specifiedand Directed. 25 All As Per Item No-23 Above But 3 Module Complete All As Specifiedand Directed. 26 All As Per Item No-23 Above But 2 Module Complete All As Specifiedand Directed. Make For Item Sl No - 14 To 26 Shall Be Legrand / Anchor / Roma / Abb / Indo Asian / HavellS. 27 S & F Of Ceiling Rose Surface Backalite 65Mm X 50 Mm, Two To Three Terminals Complete All As Specifiedand Directed.Make :- Anchor / Bajaj / Philips / HavellS. 28 Supply And Fixof Lamp Holder Insulated Body With Back Plate Suitable For Any Type Of Fitting Incl One No Of Led Bulb 15-18 Watts Base B-22 Retrofittypeall As Specified And Directed. 29 Supply And Fixing Electric Bell, Ac, 230 Volts Single Phase Ding Dong Type Complete All As Specified And Directed. 30 Supply And Fix Mcb Protected Socket ( Modular Ac Box ) 4 Module Plasic Box With 25A Cap Mcb Sp Complete All As Directed And Specified. 31 Supply And Fixingof 25 Watt Led Batten With Opal Diffuser , Ip20, Battery Backup Upto 4 Hrs.Fitting Should Have Inbuilt 2 NoS Of Li-On Battery Of 2600Ma Each.Housing Of Fixture Should Be Of Extruded Aluminium Efficacy Of Fixture >100Lpw, P>F>0.9, Thd<30% Complete All As Specified And Directed.Make: Halonix Model No: Hlb-08-25-Cw-Inv Or Equivalent In Crompton Greaves, Bajaj, Philips, HavellS. 32 Supply And Fixingofled Light Fitting 1X9w / 1X10w Bulkhead Luminaires Including Led Light Driver Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size. Complete All As Specified And Directed. Make :Halonix Model No:Hlbh-15-10-Cw-Inv Or Equivalent In Cg / Philips / HavellS. 33 Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac, Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And As Directed. 34 Supply And Fixingof 60 Watt Led Inverter Rtc ( Street Light With Inbuilt Rtc ( Real Time Clock ) For Auto On / Auto Off. Housing Made Of Pressure Die Cast Aluminium , Top Maintainable And With Clear Heat Resistant Toughned Glass , Have Secondary Lens For Better Optics, Should Have Lm80 Certified Led Of Cree, Nichia, Osram, Seoul Make Only With Constant Current Rtc Enabled Electronic Driver With 5Kv Spd, Ip66. Street Light Shall Have Inbuilt Li-On Battery Of 5200Mah And Shall Have>1.5 Hrs Battery Backup At Inverter Load In Case Of Power Failure, Efficacy > 100Lpw, Cri>70, Thd<10%, Pf>0.95, Cut Off Voltage At 300 Volt + 10% And Suitable For 50Mm Mounting Gi Pipe Complete All As Specified And Directed.Make: Halonix Model No: Hlsld-Ml04-60-Cwl-Inv-Rtc Or Equivalent In Crompton Greaves, Bajaj, Philips, HavellS.. 35 Supply And Fix In Replacement Of Security Light Fitting Bracket Made Up Of 25 / 32 Mm Dia Light Grade Pipe Of Length 0.9 Mtr With Bending In Shape By Hot Or Cold Method With 2 Nos 50X4 Mm Ms Flate Clamps With Nut Bolts And Washer Etc All As Directed 36 Supply And Fixing Ofdistribution Boarddouble Doormade Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating And Ip 43 & Ik 09 Protection, Surface Mounting, Spn 8, 240 Volts With Bus Bar Rating 200 Amps, Dust And Vermin Proof Suitable For Incorporation Of Mcb’S And Isolators Etc Flushed On The Existing Wall , To Match With Existing Surface And Making All Necessary Connections Complete All As Directed.Make : L&T / Legrand Lexichager / HavellS / Indo Asian / Abb. 37 All As Per Item No: 36 Here In Before But Spn 04 Way, 240 Volts Complete All As Directed. 38 All As Per Item No: 36 Here In Before But Spn 12 Way, 240 Volts Complete All As Directed. 39 All As Per Item No: 36 Here In Before But Tpn 04 Way, 415 Volts Complete All As Directed. 40 Supply And Fixing Of Mccb Incomer Distribution Board Double Door Vertical Type Made Out Of Crca Mild Steel Sheet Surface With Insulated Material Like Polyester Or With Epoxy Powder Coating Surface Mounting, Tpn 4 Way, 415 Volts With Bus Bar Rating 200 Amps, Dust And Vermin Proof And Ip 43 - Ik 09Protection Suitable For Incorporation Of Mccbcomplete All As Specified And Directed. Make :Legrand / Indo Asian Note : The Cost Of Removing Old Mcbbox And Making Good Of Surface As Original I.E. Brick Work, Plastering, White Washing Etc Is Included In Quated Rate. 41 Supply And Fixing Ofmccb, 415 Volts, Three Pole Of Cap 100 Amps, 25 Ka, Ics = 100% Icu, With Thermal - Magnetic Release, Including Spreader Terminals / Thimble Of Suitable Size And Making Connections Complete All As Specified And Directed.Make : Legrand Lexic Cat No: 625354 / Hager / L&T / Schneider Elect. 42 S&Fofisolator Dp63 Amp 230 Volt Complete All As Specified And Directed.Make : L&T / Legrand Lexichager / HavellS / Indo Asian. 43 All As Per Item No: 42 Here In Before Butisolator Tpn 63 Amps, 415 Volts Complete All As Directed. 44 S&Fof Isolator Sp, 6-40 Amps, 230 Voltscomplete All As Specified And Directed. 45 M&L For Blanking Plate Suitable For Mcb DbS Spncomplete All As Specified And Directed. 46 Supply And Fixingof 60 Watt Led Inverter Rtc ( Flood Light With Inbuilt Rtc ( Real Time Clock ) For Auto On / Auto Off. Housing Made Of Pressure Die Cast Aluminium , Top Maintainable And With Clear Heat Resistant Toughned Glass , Have Secondary Lens For Better Optics, Should Have Lm80 Certified Led Of Cree, Nichia, Osram, Seoul Make Only With Constant Current Rtc Enabled Electronic Driver With 5Kv Spd, Ip66. Flood Light Shall Have Inbuilt Li-On Battery Of 5200Mah And Shall Have>1.5 Hrs Battery Backup At Inverter Load In Case Of Power Failure, Efficacy > 100Lpw, Cri>70, Thd<10%, Pf>0.95, Cut Off Voltage At 300 Volt + 10% And Suitable For 50Mm Mounting Gi Pipe Complete All As Specified And Directed.Make: Halonix Model No: Hlfld-Ml30-60-Cwl-Inv-Rtc-R Or Equivalent In Crompton Greaves, Bajaj, Philips, HavellS. 47 Supply And Fixing Led Luminaire 600 Mm X 600 Mm, 35 / 36 Watt, 220 V Ac Surface / Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete.Complete All As Specified And As Directed. Make :-Bajaj Cat No:Bzrsql 36W Gz1 Wh ( Skylux ) Or Equivalent To HavellS / Philips. 48 Supply And Fixingof Indoor Decorative Led Box Type Suitable For Fixing Ceiling / Wall With Aluminium Basedirectly Retro Fit Led Tubelight , 22 Watt, , Color: Cool Day Light 4 Ft White Operating Voltage: 140-270 Voltscomplete With All Accessories Internally Pre Wired And Including Up With Three Core Pvc Copper Flexible Cable Of Size 23 / 0.0076 From Ceiling Rose To Connector Block Complete All As Specified And Directedled Batten & Led Tube Rod Shall Be Of Same Brand. 49 Supply And Fixing Led Street Light Fitting 120 Watt, 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Complete Including Taking Down Old Unsv Fittings Of Any Size / Watt Complete All As Specified And Directed. Make : Halonix Cat No - Hlsld-07-72Cw-E Or Equivalant In Crompton / Wipro / C&S 50 Material & Labourfor 10 Watts Energy Efficient Wall Mounted Inverter Led Bulk Head Light Fitting , Ip 20, Battery Backup Upto 4 Hrscomplete All As Specified And Directed. Make :Halonix Model No:Hlbh-15-10-Cw-Inv Or Equivalent In Cg / Philips / HavellS. 51 Supply And Fixingof Post Top Lantern Led Type 20 Watt 230 Watt Volts Ac Outdoor Type With Decorative Post Top For 360 Degree Indirect Light Ip 65 Protection With Impact And Corrosion Resistant Complete With Driver And Lamp Complete Incl Necessary Mounting Pole Of Gi Tubing Light Grade Suitable Dia Of Required Length Incl Necessary Form Work , All Fixing Accessories, Monkey Menace Protection Using Steel Spikes & Barbed Wire Etc Andall Electric Connections And Testing Complete Incl Taking Out Unserviceable Fittings All As Specified And As Directed. 52 Supply And Fixingof Decorative Fancy Light Fitting 2X15 Watt Retrofit / Non Retrofit Type Holder ( Baseb-22 Or E-27 ) Incl 02 Nos Of Led Bulb 15 Watts Withconnector Block, Etc. Complete With All Accessories Prewired And Including Connecting Up With Two Core Round Flexible Copper Conductor Cable In White With Suitable Size Complete All As Specified And Directed 53 Supply And Fixingof Decorative Fancy Light Fitting 1X15 Watt Retrofit Type Holder ( Baseb-22 Ore-27 ) Incl 01 Nos Of Led Bulb 15 Watts Withconnector Block, Etc. Complete With All Accessories Prewired And Including Connecting Up With Two Core Round Flexible Copper Conductor Cable In White With Suitable Size Complete All As Specified And Directed 54 Supply And Fixingof Polycarbonate Integrated Directly Retrofit Led Tube Light T8, 18 / 20 Watt ( Base Aluminium ) Colour Cool Day Light 4 Feet White, Operating Voltage:142-270 Volts In Existing Ftl Fitting Of Capacity 36 / 40 Watts In Repairs All As Specified And Directed. 55 Supply And Fixingof 10 To 15 Watts Led Bulb E-27 Non-Retrofit Type Suitable For Fancy Light Fittings 10 To 15 Watts Complete All As Specified And Directed. 56 Supply And Fixing Of 18 Watts Led Bulb Retrofit Type Suitable For Decorative Light Fittings 18 Watts Complete All As Specified And Directed. Make : Havells / Wipro / Syska / C&S. 57 S&F Indoor Led Inverter Bulb 9 Watts , B-22 Cap With Opal Diffuser , Ip 20 , Battery Backup Upto 4 Hrs Omplete All As Specified And Directed. Make: Halonix Or Equivalent To Cg, HavellS, Philips, Wipro. 58 S&F Of Led High Bay Light Fitting Out Door Type 100 Watts Pressure Die Cast Aluminium Housing, Electronic Driver Unit And Led Lamp With Refector And Ip 66 Protection Incl Necessary Mounting Bolts, Connecting Up Incl Taking Down Old Unsv Fittings All As Directed . Cat No: Lohy100 Of Lukar Or Equivalent To Halonixcg, HavellS, Philips, Wipro. 59 Supply And Fixingofled Surface Mounting Light Fitting 18 Watts With Lamp Consisting Of Prewired High Efficiency Electronic Driver High Translucent Frosted Diffuser Glare Free Smooth High Distribution And Connected Up With White Flexible 2 Core Cable Incl Taking Down Unsv Fitting Complete All As Specified And Directed. Make : Havells / Wipro / Syska / C&S. 60 Supply And Fixing Led Street Light Fitting 70 Watt, 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Complete Including Taking Down Old Unsv Fittings Of Any Size / Watt Complete All As Specified And Directed. Make : Halonix Cat No - Hlsld-07-72Cw-E Or Equivalant In Crompton / Wipro / C&S 61 Supply And Fixingof Ip 65 Protection Led Bollard Fitting9 Watts With Electronic Driver Unit And Lampfor Landscape Lighting Having Aluminium Housing Translucent Diffuser Tube Polycorbonate, The Colour Of Bollard Is Gray Or Silver And Height Of Bollard 60 Cm Including Mounting Nut Bolts Pvc Connecterincl Monkey Menace Protection Using Steel Spikes & Barbed Wire Etc And Taking Down Old Unserviceable Lights Complete All As Directed.Make: Jaquar, Bajaj Cat No: Bgbol 605 9W Led ( Flute ) , Crompton, Philips 62 Material & Labourof 3 Pole Mccb 400 Amps , 50 Hz, 415 Volts Adjustable Type With Rupturing Capacity 50 Ka And Making Connections Of Incoming And Out Going Wires Are Properly Fitted In Suitable Lugs / Thimples Including Taking Out Old Unserviceable Mccb Complete All As Specified And Directed. 63 All As Per Item No 62 Above But 200 Amps Complete All As Specified And Directed. 64 All As Per Item No 62 Abovebut 250 Amps Complete All As Specified And Directed. 65 Material & Labourfor Mccb 3 Pole415 V Micro Processor Type, 25 To 100 Amps With Breaking Capacity 16 Kacomplete All As Specified And Directed. 66 Suuply And Fix Of Porcelain Tewireable Kit Kat Fuze Of Capacity 63 Amps To 400 Amps Complete All As Directed. 67 M&L In Replacement Offabrication Of Sheet Metal Enclouser To Accommodate 04 Nos Electric Meters Of Size 800 Mm X 500 Mm X 150 Mm Deep And 1.6 Mm Thick Ms Sheet, Powder Coated, Bakelite Sheet With Side Hung Shutter Including Provision Of Locking Arrangement And Niche Covered With 4 Mm Thick Plain Glass , Including Locking Arrangement & Open Wiring Coverd With Flexible Pvc Pipe Of Suitable Sizecomplete All As Specified And Asdirected. 68 Supplying And Fixing Smart Single Phase Two Wire Dual Source Prepaid Energy Meters Bis 15884 Marked In Existing Meter Board / Floor Panels With Pre Payment Capacity Touch Keypad Based Digital Having Current Range 10-60 Amp 240 Volt Accuracy Class 1.0 Alongwith Parallel Home Display Split Unit With Inbuilt Load Control Switch Containing Provision For Tod And Rtc, Inbuilt Feature To Sense The Dg Mode Through Plsi, Dual Source Registration Wrt Grid As Well As Dg Supply And Dynamic Load Allocation Facility From Grid And Dg, Capable To Define For Tariff Slabs, Happy Hours And Holiday Definition Making All Electric Connections Complete All As Specified And Directed. 69 Supply And Fixing Of Exhaust Fan 300 Mm Sweep Heavy Duty Complete With Self Closing Ms Louvers, Mounted In Suitable Opening Arrangement And Suitable For Operation On 230 / 240 Volts Single Phase, 50 Hz, 1400 Rpm , Ac Supply With And Including Two Core Pvc Insulated, Pvc Sheathed Copper Conductor Flexible Cable 24 / 0.2 Mm And Making All Necessary Connection And Fixed By Using 4 Nos 100 Mm Long 10 Mm Dia Bolts, Nuts And Washers And Grouted In Wall In Cm 1:3 ( Including Opening Of Walletc ) Completed All As Directed. 70 S & Fof Exhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter, Voltage 230V, 50 Hz, Rpm 1200, Copper Winding Of Sweep 200Mm / 250Mm And Making All Electric Connections Complete All As Specified And Directed. Make: Havells / Cg / Ge Note: The Unsv Old Oneitem Srl No 68To 70 Is Mes Property Andwill Be Handed Over To Mes Store Yard . 71 Supply And Fixing Of Off Load Change Over Switch, 4 Pole, 415 Volts, 50 Hz, Ac, 200 Amps Side Handle Operated Conforms To Is 60947-1 & 3Incl Making All Incoming And Out Going Wires Are Properly Fitted Through Lugs / Thimbles Complete All As Specified And Directed. Make: HavellS Cat No:Ihhcd01200 Or Equivalent To L&T, Indo Asian 72 Supply And Fixing Of Switch Disconnector Fuze 200 Amps , 3 Pole & Neutral , Ac, 415 Volts, 50 Hz With Panel Mounting Cubical Type In Sheet Steel Encl, With 3 NoS Hbc Fusesincl Making All Incoming And Out Going Wires Are Properly Fitted Through Lugs / Thimbles Complete All As Specified And Directed. Make: HavellS Cat No:Ihhcd01200 Or Equivalent To L&T, Indo Asian 73 Supply And Fixing In Replacement Of 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminiumconductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections Suspended By Insulating Hangers Not More Than 1 Metre Apart Including 4Mm Suspension Wire, One Twin Core Cable Flat Or Circular Of Size 10 Sqmm 2 Corecomplete All As Directed.Make:Finolex / Havells / Rrcables. 74 All As Per Item No 73 Abovebut 16 Sqmm2 Core Omplete All As Directed 75 Supply And Fix Of Junction Box Made Out Ofthermo Plastic Material Of Size 240X130x110 Mm With Provision Of Single Phase Cable Connector Incomming And Out Going With Mcb Sp 6-32 Amps For Security Light Fitting / Ptlip 65 Protection Totally Enclosed Weather Proof With Cable Entryalong With Gi Clamps Nut Bolts & Washer Fixed On Pole Including Dismantling / Taking Out Old Unserviceale One All As Directed. 76 Taking Down And Re Fixing The Existing Water Geyser / Ceiling Fan / Exhaust Fan Any / Type And Any Sizeafter Necessary Servicing / Greasingcomplete Incl Painting All As Specified And Directed By Engr-In-Charge To Match With Existing Surface 77 Material And Labour For Road / Path Wayany Type ( Concrete ) Cutting , Including Excavation, Returning Filling In, Spreading, Leveling, Well Ramming In Layers, Soiling With Broken Boulders / Stones, Wbm 7.5 Cm Thick Coarse Aggregate Received From Dismantling The Existing Road, Premix, Carpeting 25 Mm Thick Using Ready Mix Patch Mate Material, Rolled And Compacted For Road Patch Repair Work, Completeall As Directed. 78 Meterial And Labour For Cement Concrete In Foundations For Pole Or Any Other Worktype C21:3:6 With 40 Mm Gradedcrushed Stone Aggregate All As Directed 79 Meterial And Labour For Cement Concrete In Foundations For Pole Coping Or Any Other Worktype B01:2:4 With 12.5Mm Graded Crushed Stone Aggregate All As Directed 80 Meterial And Labour For Cement Concrete In Foundations For Pole Or Any Other Worktype D21:4:8 With 40 Mm Graded Crushed Stone Aggregate All As Directed. 81 Earthing Complete With Galvanised Steel Earth Plate Electrode Of Size 60Cmx 60Cm X 6Mm Thick Electrode Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Meters Deep Below The Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level Connected To Gi Earthwire 4 Mm Diaby Means Ofbolts, Nuts, Check Nuts And Washers And Earth Lead Protected By 15Mm Dia Gi Pipe Medium Grade Connected To Main Distribution Board / Earthingtest Point All As Shown On Electrical Plate No-03 Of Ssr Part-1 And All As Specified Including Testing On Completion.Note: The Unit Rate Shall Also Include For Excavation, Earth Work In Hard / Dense Soil, Plain Cement Concrete 1:3:6 Mix, Type C1 Pit, 40Mm Thick Rcc 1:2:4 Mix Type B1 Cover Reinforced With 8Mm Dia Tmt Bars @ 150Mm C / C Both Ways , Gi Funnel With Watering Pipe 20 Mm Dia, Wire Mesh, Salt And Charcoal, Protection Pipe For Earth Lead Upto 7.50M Long Complete In Addition To Item No 1 ( A ) To ( E ) Of Preamble ( Notes ) Under Sub Heading Earthing, Specified In Ssr Part-Ii Earth Lead Wire And Protection Pipe Beyond 7.5M Shall Be Measured And Paid Separately. 82 Excavation In Trenches N Exc 1.5 Mtr Wide And N Exc 1.5 Meter In Depth For Foundation, Laying Of Cable, Pole Etc Or For Shafts, Wells, Cesspits, Manholes Pier Holes Etc Not Exc 10 Sqm On Plan And Not Exc. 1.5 M In Depth And Getting Out In Soft / Loose Soil Complete All As Specified And Directed By Engr-In-Charge 83 Returning, Filling In Including Spreading, Levelling, Watering And Well Ramming Excavated Soilin Layers Not Exceeding 25 Cm Thick Each, Back In Trenches After Cables Have Been Laid And Tested, Poles, Stays , Struts Have Been Errected And Tested , All As Specified. 84 Removing Excavated Surplus ( Soil ) Obtained From Excavation To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete, All As Specified. 85 M&L For Brick Protection For Lt Cable With Sub Class B Bricks Laid Dry And Flat Abutting Each Other With Gaps Between Adjacent Bricks Not Exceeding 10Mm With Width Equal To Length Complete All As Specified And Directed By Engr-In-Charge 86 Supplyandlayingdryriversand To Belaidin 8 Cms Before Laying Of Cable And 15 Cms Above Cable In Trencheascablecushioningandcovering Complete Allasspecifiedanddirected. Note: For Payment Purpose Punned Thickness Shall Be Measured 87 Supply And Fixing In Repair Of Gi Pipe Light Grade Size 40 Mm Dia For Protection Of Ugcable , Road Crossing, Complete And Incl M & L For Clamps Suitable Size With Nuts, Bolts, Incl Excavation, Pcc Work For Fixing Of Path Way Lights Complete All As Specified And Directed.Make:Jindal / Surya / Tata 88 Supply, Laying , Jointing , Testing And Commisioninglt Underground Cable 1100 Volts Grade Xlpe Insulated And Steel Strip Or Wire Armoured Heavy Duty With Multistranded Aluminium Conductor 25 Sqm 4 Coresizeincluding Taking Out Unserviceablecomplete All As Specified And Directed.M Note:- ( I ) Excavation And Earth Work Cable Protection And Sand Cushioning Shall Be Measured And Paid Seperately . 89 Dittoall As Per Item No 88 But Size 16 Sqmm 4 Core 90 Dittoall As Per Item No 88 But Size 10 Sqmm 2 Core 91 Material And Labour For Point Wiringwith 1.5 Sq Mm ( Nominal Area ) Frls, Pvc Insulated Un-Sheathed And Multi Stranded 1100 Volts Grade Single Core Including One Single Core 1.5 Sqmm Frls Pvc Insulated Unsheathed Copper Conductor Cable As Earth Continuity Conductor ( Colour Green ) Drawn Through And Including Stove Enamelled Steel Conduit With All Aceessories Fixed To All Type Of Electrical Fittings And Earth Terminal / Earth Dooly, Complete With Pvc Rectangular Block And Rawl Block And Rawl Plugs Fixed To Wall / Ceilings / Roofs / Concealed With And Including 3M Thick Ms Sheet Fabricated Terminal Boxes / Modular Boxes, Flush Mounted For Mounting Of Switches, Switch Socket Combination Or Flame Proof Switches Etcwith 3Mm Thick Hylem Sheet Top Cover As Specified And Directed For The One Light Point / Fan Point / Exhaust Fan Point Controlled By One 1-Way Switch. 92 - Ditto - All As Per Item No - 91 Above But For One 3 Pin 5 Amp Socket On Same Board All As Directed. 93 - Ditto - All As Per Item No - 91 Above But For One 3 Pin 5 Amp Socket On Indipendant Board All As Directed. 94 Supply & Fixing Of Switch Flame Proof Rotarytype With Termination Box Lm6, 16 Amps Single Pole 250 Volt, 1 Way Complete All As Directed. 95 Supply And Fixing Of Flame Proof Switch Socket & Plug Combined In Lm6 Cable Termination Box In Lm6, 16A, 250V, P+Earth Complete All As Directed. 96 Supply And Fixing Led Light Fitting 2X16 Watt Flame Proof, Cmri Certified Recommended For Gas / Vapour Group Of Iia & Iiib, Zone 1 & 2 And Ip 65 Protection With Die Cast Aluminum Hosing With Heat Resistant Toughened Glass With Led Tube Light Fixtures Driver, Holders, Connector Etc. Complete With All Accessories Prewired And Including Connecting Up With Three Core Flexible Copper Conductor Cable With Suitable Size Complete All As Directed. 97 M&L For Earthing Complete With Copper Plate Earth Electrode Of Size 60 Cm X 60 Cm X 3.15 Mm Thick Burried Directly In Ground Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level Connected To Copper Strip Of 20 Mm X 3 Mm Thick By Means Of Brass Or Copper Alloynuts, Bolts, Check Nut And Washer Including Earthing Pit Made By Pcc ( 1:3:6 ) Type C-1, Rcc ( 1:2:4 ) Type A-1 Pre Cast Cover ( 54Cm X 54Cm X 5 Cm ) Duly Reinforced With And Including 8 Mm Dia Tmt Steel Bars @ 150 Mm C / C Both Way, One Lifting Handle Made Of 8 Mm Dia Tmt Bar Embedded In Precast Cover Slab And 15 Mm Dia Medium Grade Gi Pipe For Watering With Funnel Having Wire Mesh And 40 Mm Dia Medium Grade Gi Pipe For Protection Of Copper Strip Including Providing Charcoal Or Coke And Salt In Alternative Layer Of 15 Cm Complete All As Shown In Electrical Plate No-3 Including Necessary Earth Work Such As Excavation, Removal Of Soil N.Exc 50 Mtr, Returning And Refilling Dismantling The Old Unserviceable Earthing All As Specified And Directed. 98 Supply And Fixing In Replacement Ofgi Pipe Mediumgrade 80 Mm Bore Inclusive Of All Fittings Such As Tees Bends, Elbows, Reducer, Bell Mouth Tube Ends And All Fixing Accessories Such As Couplers Hook, Nuts, Saddlers, Pipe Hook Etc ( 8.0 Meter Long ) Complete With Gi Base Plate, Finial Taper Plug, Bolts, Nuts & Screws Etc Including Making The Holes On The Pole ( Bottom And Top ) Suitable Sizefor Drawing Of Wire 1.5 Sqmm 3 Core Round Flexible For Connection Of Security Light Fitting From Junction Box To Light Fittings Including Of One Primer Coat, One Under Coat And One Finishing Coat Of Silver Paint Including Dismantling / Taking Out Old Unserviceale One All As Specified And Directed. 99 M & L For Taking Down Of Geysers25 / 35 / 50 Ltrs Capacity Of Any Type / Make From Existing Location By Unscrewing Bolts, Disconnecting Water And Electric Connections And Painting The Outer Surface Of Geyser As Per Original Shade With Two Coats Of Synthetic Enamel Paint Over One Coat Of Primer By Spray Gun After Scrapping The Existing Paint, Denting, Filling Depression With Putty Etcincludingwriting Of Mes No In 5Cm Height And Refixing The Geyser In Position Including Water / Electric Connection And Testing, Complete All As Directed. 100 Taking Down Of Unserviceable Geyser Of 25 / 35 / 50 Ltr Capacity Of Any Type / Make From Existing Locationafter Disconnecting And Opening Of Nuts And Bolts Carefully And Taking Out Inner Tank, Descaling The Inner Surface By Scrapping Carrying Out Soldering / Brazing / Gas Welding To Prevent The Leakage, Filling Of Glass Wool & Assembling The Same After Repair Including Replacement Of Required Number Of Stainless Steel / Copperscrews, Nuts & Bolt For Fixing Of Syphon Assembly, Including Grouting Of Fasteners 04 Nos Wherever Requiredat Site For Fixing Of Geyser Any Type / Capacity And Etc Complete And Refixing The Same After Repair / Replacement Of Foundation Nuts And Bolts, Connecting To Water Mains And Electric Supply, After Carrying Out The Repair Work / Replacement Complete All As Specified And As Directed Note:- Spare Parts Shall Be Measured And Paid Separately Under Respective Items Complete All As Specified And Directed . 101 Supply And Fixing In Replacement Of Safety Pressure Valve With Vent Isi Marked, Suitable For Geysers Of Any Type / Make And Capacity Complete All As Directed. 102 Supply And Fixing In Replacement Of Indicator Lamp Red & Green ( Round Shape ) Suitable For Geyser Of Any Type / Make And Capacity Isi Marked Including Making Necessary Electric Connection Complete All As Directed. 103 Supply And Fixing In Replacement Of Copper Inner Shell Of Suitable Size Made Of Copper, Duly Pressure Tested For 30 Metre Water Head, Suitable For Geyser Of Any Type / Make And 25 Litres Capacity With And Including All Suitable Fixing Accessories Including Testing After Assembled & Fixed At Site Complete All As Specified Anddirected . 104 All As Per Srl Item No 103 Here-In-Before But For 35 / 50 Lts Capacity. 105 Supply And Fixing In Replacement Of Outer Shell Of Suitable Size Made Of Steel Sheet Isi Marked For Geyser Of Any Type / Make And 25 Ltrs Capacity Complete With All Suitable Accessories Such As Thermal Insulation Etc Complete All As Directed. 106 All As Per Srl Item No 105 Here-In-Before But For 35 / 50 Lts Capacity. 107 Supply And Fixing In Replacement Of Heating Element 2 Kw ( Circular / Triangle ) Capacity Isi Marked For Geyser Of Any Type / Make And Capacity Including Making Necessary Electric Connection And Testing The Geyser Complete All As Directed.Note : The Petty Items Such As Nut, Bolt, Clamps Etc Are Deemed To Be Included In Quoated Rates. 108 All As Per Srl Item No 108 Here-In-Before But 1.5 Kw Capacity. 109 Supply And Fixing In Replacement Of New Glass Wool Of Superior Quality Of 16 Kg / Cum Density In Geyser Of Any Type / Make And For 25 Ltrs Capacity Of Geyser Complete All As Specified And As Directed . 110 All As Per Srl Item No 109 Here-In-Before But For 35 / 50 Lts Capacity. 111 Supply & Fixing In Replacementof Copper Flexible Cable, Pvc Insulated, 3 Core, 70 / .0076Complete All As Specified And As Directed . 112 Supply And Fixing In Replacement Of Modular Mcb Protected Power Units 16-25 Amps ( 6Module Plate, 16-25 Amps Starter, 25 Amps Socket, 25 Amps Plug& Mcb Spn 16-25 Amps ) Including Suitable Size Of Modular Sunken Box , Fixing Accessories Etc For Accomplete All As Directed. 113 Supply And Fixing In Replacement Of 15Mm Bore Angle Stop Valve Cast Copper Alloy Chromium Plated Fancy Type, High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Or Union And Fixed Complete All As Specified And As Directed . 114 Supply And Fixing In Replacement Of Thermostat Isi Marked For Geyser Of Any Type / Make And Capacity Including Making Necessary Electric Connection And Testing The Geyser Complete All As Directed. 115 Supply And Fixing In Replacement Of Non Return Valve In Position Isi Marked Made Out Of Cast Copper Alloy, Internally Screwed On Both Ends, Suitable For Iron Pipe Of Size 15 Mm, Suitable For Geysers Of Any Type / Make And Capacity Complete All As Directed. 116 Supply And Fixing In Replacement Of C P Connection 450 Mm Long And C P Brass Adopter 10 Mm Dia With Washer For Inlet & Outlet Pipe, Isi Marked For Geyser Of Any Type / Make And Capacity Complete All As Directed. 117 Supply And Fixing In Replacement Of Inner Base Assembly Complete With Inlet / Outlet, Heating Element 1.5 / 2.0 Kw, Thermostat With Drain Plug And Screw Including Clamps For Holding The Elements, Nuts, Bolt Etc, Isi Marked For Geyser Of Any Type / Make And 25 / 35 Ltrs Capacity Complete All As Directed. 118 All As Per Srl Item No 117 Here-In-Before But For 50 Lts Capacity. 119 Supply & Fixing In Replacementof Plug Top 3 Pin 16 Amps Earth Metal Clad Suitable For Industrial Type Db Complete All As Directed. 120 M&L In Replacement Of 15Mm Bore Steel Water Tubingmedium Grade, Galvanised Withand Including All Fittings And Fixturefixed & Concealed Inwall / Ceiling Or Laid In Floors Or Any Position ( Including Cutting Chases And Making Good With Cm 1:3 Cement Work And Colour Matching On Existing Wall ) Complete All As Specified And Directed . 121 Matrial And Labour In Replacement Of Grouting Of Nuts & Bolts ( Fastners ) 04 Nos Of Each For Fixing Only Of 50 / 35 / 25 Ltrs Capacity Geyser Including Cement Work And Colour Matching On Existing Wall Complete All As Directed. 122 Matrial And Labour For Brazing / Welding Of Inner Copper Tankat Leaking Spots Up To Five Leakage Of Geyser Of Any Type / Make / Capacity Complete All As Directed. 123 Supply And Fixing In Replacement Of Neoprene Seal ( Bottom Ring ) Of Superior Quality, Isi Marked Suitable For Geysers Of Any Type / Make And Capacity Complete All As Directed. 124 Supply And Fixing In Replacement Of Bottom Cover Plate ( 2 Halfs ) With Matching Colour Of Existing Geysers Of Any Type / Make And Capacity Complete All As Directed. 125 Taking Down To Desert Cooler Of Any Make & Size, Fixed At Different Site / Location And Repair To Desert Cooler To Stop Any Type Of Leakage, Tightening / Replacingto Rusted Screw Nuts, Bolts & Washers With New Of Same Size Etc Including Floor Cleaning, Scraping All Scales Internally & Externally Surfaces And Painted Todesert Cooler With Two Coats Of Synthetic Enamel Paint ( Hammer Tone ) On Externalsurface & 2 Coat Of Black Japan Paint On Internal Surfaces Over One Coat Of Red Oxide Primer With Help Ofspray Gunmachine Includingwriting Of Mes No In 5Cm Heightand Re-Fixing The Desert Cooler After Necessary Oiling And Greasing Of Fan And Water Lifting Pump At Site / Location Complete All As Specified And As Directed 126 Supply & Fixing In Replacementof15mm Bore Ball Valve With Float Ball Ptmtcomplete All As Specified And As Directed 127 Supply & Fixing In Replacementofpvc Water Distributor 3-Way Complete All As Specified And As Directed 128 Supply & Fixing In Replacementofselector Switch ( Three Speed ) Complete All As Specified And As Directed 129 Supply & Fixing In Replacementof Pvc Bend Right Angle Complete All As Specified And As Directed 130 Supply & Fixing In Replacementof3-Pin Plug Top, 6Amp, 230 Volt, Ac Complete All As Specified And As Directed 131 Supply & Fixing In Replacementofcooler Fan Motor With Blade, 1400 Rpm, 50Hz, 230 Volts, Ac Suitable For Mild Steel Body Of Desert Cooler Having Nominal Air Flow Capacity 4000 Cum Per Hour.Make: Khaitan Complete All As Specified And As Directed . 132 Supply & Fixing In Replacementofwooden / Grass Pads ( Set Of Three ) Complete All As Specified And As Directed . 133 Supply & Fixing In Replacementof 15Mm Bore High Densitypolythene Pipe Complete All As Specified And As Directed . 134 Supply & Fixing In Replacementof15mm Bore Stop Cock Ptmt Complete All As Specified And As Directed . 135 Supply And Fixing In Replacement Of Complete Mild Steel Body Of Desert Cooler Of Capacity 300 Cum Duly Painted With Two Coats Synthetic Enamel Paint On External Surface & Black Japan Paint On Internal Surfaces Over One Coat Of Red Oxide Primer With Spray Gun Machine. The Body Of Desert Cooler Will Be Fabircated As Under Mentined Complete All As Specified And As Directed By Engineer-In-Charge. ( A ) The Top And Bottom Made Out Of 1.25Mm Thick M.S Galvanised Sheet. ( B ) Side Panels ( Set Of Three ) Made Out 1.00Mm Thick M.S Galvanised Sheet With Wood Pad & Wire Netting Of Gi Wire 1.4Mm Dia 25Mm Mesh For Holding Pads. ( C ) Front Grill Of Suitable Size And Of Approved Quality Mild Steel. ( D ) With And Includingfan Motor With Blades, 50Hz, 230 Volt Ac’S , Water Lifting Pumb And Eletric Wiring / Fittings Complete All As Directed. 136 Material & Labour For Shifting Of Split Type Ac Of 1.5 / 2.0 Tr Capacity, Any Type / Make, With Stabilizer Including Taking Down Carefully Indoor And Outdoor Unit, Copper Piping, Drain Pipe And Thermal Sleeve, Lifting Angle Etc And Installating The Same To New Location Using Newcopper Piping Of Suitable Gauge For Suction And Delivery With Insulation, Drain Pipe And Re-Fixing Arrangement I. E. Lifting Angle, Fastners, Nut Bolt, Washer Etc, Testing & Commissioning, Complete All As Directed.Note : The Cost Of Making Hole For Passing Through Inlet / Outlet Copper Pipes, Drain Pipe And Electrical Cord And Making Good Of Surface At Both Location As Original By Plastering / Whitewash / Colour / Distemper Etc Is Included In Quoated Rate And No Extra Payment Will Be Made To Contractor In This Effect. 137 Material & Labour For Shifting Of Window Type Ac Of 1.5 / 2.0 Tr Capacity, Any Type / Make, With Stabilizer From One Location To Another Complete With And Including Making Of Suitable Opening In Brick Wall Or Removing Aluminum Grill And / Or Glass Panel From Existing Window, Including Supply And Fixing Of New Wooden Frame Of Suitable Size And Thickness For Proper Fixing Of Outer Chassis Of Ac At New Location, Making Good Of Disturbed Surface As Original Etctesting & Commissioning, Complete All As Directed.Note : The Cost Of Making Suitable Opening In Brick Wall Or Removing Aluminum Grill Or Glass Panel From Existing Window And Making Good Of Surface At Both Location As Original By Plastering / Whitewash / Colour / Distemper Etc Is Included In Quoated Rate And No Extra Payment Will Be Made To Contractor In This Effect. 138 Taking Down Serviceable Window Type Air Conditioner Capacity 1.5To 2.0 Ton Strip Opening, General Cleaning Of Filter And Complete Units With Detergent And Chemiclal And Re-Fixing In The Same Opening Or Shifted To Other Opening / Room Complete All As Specified And As Directed 139 S&F In Replacement Of Pcb For Split Type AcS 1.5 / 2.0 Tr Of Various Make And Model Of Capacity All As Specified And Directed. 140 Disconnecting To Unserviceable Sealed Compressor Of 1.5 Ton / 2.00 Ton Capacity Window Type Ac And Replaced With New Sealed Compressor Of Existing Capacity& Model Including Soldering Of Liquid / Gas Pipe , Cleaning The System & Testing The Leaking Etccomplete All As Specified And Directed By Engineer-In-Charge 141 Supply & Fixing, In Replacement, Of New Hermetically Sealed Rotary Type Compressor Of Capacity 1.5 Ton Suitable For Air Conditioner Of Any Make / Type Including Replacement Of Foundation Bolts, Rubber Pad Etc, Complete All As Directed. 142 All As Per Above Item No 141 Here-In-Before But2.0 Ton Capacity Split Type Ac Complete All As Specified And As Directed 143 Supply & Fixing In Replacement Of Condensing Unit Of Split Type Ac Of Existing Make And Model Suitable For Capacity 1.5 / 2.0 Tr With Anti Corrosive Blue Fins, Complete With Condensing Coil, Coil Frame, Wiring Kit, Starting And Running Capacitor, Relay Condensing Motor With Blade All As Specified And Directed. 144 Supply & Fixing In Replacementofindoor Unit Of Split AcS Of Existing Make And Model Suitable Forsplit Type Ac 1.5 / 2.0Ton Capacity, With Suction, Discharge, Water Drainage Pipe Line, Wall Mounting Bracket Etc All As Specified And Directed. 145 Supply & Fixing In Replacementof Condenser Unitof Existing Make And Model Suitable For Window Type Ac 1.5 Ton Capacity, Complete All As Specified And As Directed . 146 Supply & Fixing In Replacementof Cooling Coilof Existing Make And Model Suitable Forwindowtype Ac 1.5 Ton Capacity, Complete All As Specified And As Directed . 147 Material & Labour For Charging Of Air Conditioner Window / Split Type Of Capacity 1.5 / 2.0 Ton With R - 22 Or Any Other Recommended Refrigerant Gas, Including Detecting Of Leakage, Repairing Using Welding / Brazing, Pressure Testing, Replacement Of Connection Lead, Tin Coated Copper Thimbles And Installation Of Ac At Site And Testing On Full Load For 24 Hours Continuously Etc Complete All As Directed. 148 Supply & Fixing In Replacementof Cooling Coil Fan Motor Water Proof For Split Ac Of Any Capacity ( 1.5 / 2.0 Tr ) Suitable For Any Make Complete All As Specified And Directed. 149 Supply And Fixing In Replacement Ofswing Motor For Split Type Ac Of Capacity 1.5 Tr / 2.0 Tr Indoor Unit For Any Type And Makes As Per Existing All As Specified And Directed. 150 Supply & Fixing In Replacementof Thermostat Switchwith Existing Make Model Suitable Forwindow Type / Split Type Ac 1.5 / 2 Ton Capacity, Complete All As Specified And As Directed . 151 Supply & Fixing In Replacementof Starting Capacitor 100 -120 Mfdsuitable For Window / Split Type Ac Any Capacity, Complete All As Specified And As Directed . 152 Supply & Fixing In Replacementof Starting Capacitors 80-100 Mfd For 1.5 Ton AcS All As Specified And Directed. 153 Supply & Fixing In Replacementof Running Capacitor 50 Mfd For 2 Ton AcS All As Specified And Directed. 154 Supply & Fixing In Replacementofrunning Capacitor 45 Mfd For 1.5 Ton AcS All As Specified And Directed. 155 Supply & Fixing In Replacementofrunning Capacitor 36 Mfdfor Window / Split Type Ac Any Capacity Complete All As Specified And As Directed. 156 Supply & Fixing In Replacementof Unsvserviceable Front Grillas Per Existing Suitable For Window Type Ac 1.5 / 2.Toncapacity Complete All As Specified And As Directed 157 Supply & Fixing In Replacementofblower Motor Suitable For Window Type Ac Of 1.5 / 2 Ton Capacity Complete All As Specified And As Directed . 158 Supply & Fixing In Replacementof Flexible Pvc Insulatedcopper Conductor Connection Lead 3- Core , Size 23 / 0.0076Suitable Foracof Anycapacitycomplete All As Specified And As Directed . 159 Supply & Fixing In Replacementofknob Suitable For Window Typeac 1.5 / 2Toncapacitycomplete All As Specified And As Directed 160 Supply & Fixing In Replacementof Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 4 / 5 Kva For 1.5 / 2.0 Trincluding Making Good Surface As Original By Plastering And Whitewash / Colour / Distemper Etc Complete All As Directedcomplete All As Specified And Directed. 161 Supply & Fixing In Replacementofselector Switch ( On / Off Five Steps ) Suitable For Window Type / Split Typeac 1.5 / 2Toncapacitycomplete All As Specified And As Directed 162 Supply And Fixing In Replacement Ofremote Sensor For Split Type Ac 1.5 / 2.0 Ton Capacity Suitable For Existing Make And Model All As Specified And Directed. 163 Supply & Fixing In Replacementof Over Load Protection Suitable For Split Type Ac 1.5 / 2Toncapacitycomplete All As Specified And As Directed 164 Supply And Fixing In Replacement Of Gas Strainer For Window Type Ac 1.5 / 2.0 Ton Capacity All As Specified And Directed. 165 Supply & Fixing In Replacementofpvc Canopy Suitable For1200 / 1400 / 1500Mm Sweep Fan Completeall As Specified And As Directed . 166 M&L In Replacement For Ms Work For Stand / Bracket ( 02 Nos ) Fabricated From Structural Steel Section Including Nut, Bolt, Washer, Welding. Bedding Cold Or Hot, Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Complete All As Directed. 167 Supply And Fixing In Replacement Of Mcb C Curve Type, 10 Ka, 10 To 32 Amp, Single Pole With Over Load And Short Circuit Protection Complete All As Directed. 168 Supply & Fixing In Replacementof New Compressor Suitable For Deep Freezer Of Any Make / Type And Any Capacity Including Replacement Of Foundation Bolts, Rubber Pad, Capillary Tubes Etc Complete All As Directed. 169 Recharging Of Eco Friendly R-410Arefrigerent Suitable Forwindow Type / Split Type Ac Of 1.5 / 2.0 Ton Capacity Including Testing All As Specified And Directed. 170 Dismandling And Opening Of Stabilzer Unit Removing Variable Transformer And Taking Out Of Old Burnt Copper Wire Of Make Htp / Devidayal After Provisioning E Class Insulator Material Varnishing And Refixing On Existing Places Of Capacity 5 Kva / 4Kva Stabilizer Complete All As Specified And Directed. 171 Supply & Fixing In Replacementof Cooling Coil For Refrigerator Of Capacity 280 / 320 Litres Suitable For Any Make Complete All As Specified And Directed. 172 Supply & Fixing In Replacementof Condencing Coil For Refrigerator Of Capacity 280 / 320 Litres Suitable For Any Make Complete All As Specified And Directed. 173 M & L For Complete Replacementof Rusted Out Door Unit Body Package Type Split Ac 8.75 Tr As Per Existing Size, Colour And Make And Refixing In Position Including Making Connection, Testing Complete All As Specified And Directed. 174 Supply & Fixing In Replacementof Pvc Pipe Of Size 15 Mm Dia Heavy Grade With L Bend, Elbow, Tee, Etc Suitable To Connect Window / Split Type Ac Drain Line. Pipe Lines Shall Be Fixed On Wall Or Floor Upto 5 Level Of The Building With Necessary Clamping Arrangement Complete All As Specified And Directed. 175 Supply And Fixing In Replacement Of Pcb For Refrigerators Of Various Make And Model Of Capacity All As Specified And Directed. 176 Rechargingr-134 ( A ) Gas For Deep Freezer 286 / 310 Litres Capacity , Refrigerator & Water Coolers All As Specified And Directed. 177 Supply And Fixing In Replacement Of Fan Motor With Blade Suitable For Deep Freezer 286 / 310 Litres Capacityall As Specified And Directed. 178 Supply And Fixing In Replacement Of Starting Capacitor Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 179 Supply And Fixing In Replacement Ofrunning Capacitor Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 180 Removing The Existing Insulation From Suction Line Of Split AcS Of Various Size Inserting Of New Insulation Complete With Spacers And Saddle Etc. On Walls Without Damage To Existing Pipe All As Specified And Directed. 181 Supply And Fixing In Replacement Ofcopper Tube Heavy Duty Of Size 3 / 8 Including Jointing, Testing Etc All As Specified And Directed. 182 All As Per Item No 181 But1 / 4 Size 183 All As Per Item No 181 But 1 / 2Size 184 All As Per Item No 181 But 5 / 8Size 185 Supply And Fixing In Replacement Ofgun Metal Suction Valve For Size 5 / 8All As Specified And Directed. 186 All As Per Item No 185But1 / 4Size 187 All As Per Item No 185But1 / 2 Size 188 Supply And Fixing In Replacement Of Ac Contactor, Single Phase 230 Volt, 50 Hz Capacity 25 Amps Taking Double Pole Complete All As Specified And Directed. 189 Supply And Fixing In Replacement Ofthermostat For Water Cooler All As Specified And Directed. 190 Supply And Fixing In Replacement Ofstarting Relay For 1.5 / 2.0 Ton Window / Split Type Acall As Specified And Directed. 191 Supply & Fixing In Replacementofload Protection Relay Unit Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 192 Supply & Fixing In Replacementofstarting Capacitor Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 193 Supply & Fixing In Replacementof Running Capacitor Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 194 Supply & Fixing In Replacementof Sealed Compressor Ofwater Cooler Of Capacity40 / 80Or 100 / 150 Liters And Replaced With New Sealed Compressor Of Existing Capacity& Model Including Soldering Of Liquid / Gas Pipe , Cleaning The System Arresting The Leaking Etccomplete All As Specified And As Directed By Engineer-In-Charge. Make :-- Sri-Ram / Tikamshah / Kirlosker. 195 Supply & Fixing In Replacementof Starting Capacitors 45-60 Mfd For Water Cooler All As Specified And Directed. 196 Supply & Fixing In Replacementofrunning Capacitor 25 Mfd For Water Cooler All As Specified And Directed. 197 Supply & Fixing In Replacementof Starting Relay Assembly Suitable Forwater Cooler Of 100 / 150 Liter Capacitycomplete All As Specified And As Directed . 198 All As Per Above Item No 197 Butwater Cooler Of Capacity 40 / 80 Liter Complete All As Specified And As Directed 199 Supply & Fixing In Replacementof Over Load Protection For Suitable Forwater Cooler Of 40 / 80 Or 100 / 150 Liter Capacitycomplete All As Specified And As Directed . 200 Supply & Fixing In Replacementof Fan Motorsuitalbe For Water Cooler Of 100 / 150 Liter Capacity Complete All As Specified And As Directed . 201 All As Per Above Item No 200 Butwater Cooler Of Capacity 40 / 80 Liter Complete All As Specified And As Directed 202 Supply & Fixing In Replacementof Aluminium Fan Blade For Water Cooler Blower Motor 1 / 35 Hp Capacity All As Specified And Directed 203 Supply & Fixing In Replacementof15 Mm Bore Self Closing Tap Push Typecast Copper Alloy Chromium Plated Fixed To Water Coolercomplete All As Specified And As Directed 204 Cleaning To Water Coolers 100 / 150 Ltrs Capacity Internal & External Surfaces Of Suitable Repairs Tobody & Stop Leakage Etc, Replacing Unserviceable Nut Bolts & Washers Etc Including Preparation Of External Surfaces Ofbodyandpainted Withanticorrosive Synthetic Enamel Paint Withhelp Of Spray Gunmachine Over A Coat Of Red Oxide Primerand Writing Sm / Mes No In 5Cm Height Complete All As Specified And As Directed 205 All As Per Above Item No 204 Butwater Cooler Of Capacity 40 / 80 Liter Complete All As Specified And As Directed . 206 Supply And Fixing In Replacement Ofhermeticaly Sealed Or Rotary Compressor For Refrigerators 165 Litres Capacity All As Specified And Directed.Make : Kirloskar / Tecumseh / Copeland / Lg / Hitachi. 207 Supply & Fixing In Replacementoffruit / Vegetable Tray Of Any Capacityas Per Existing Make & Model Complete All As Specified And As Directed . 208 Supply & Fixing In Replacementofpigmy Lamp ( Bulb ) Complete All As Specified And As Directed 209 Supply And Fixing In Replacement Ofcapillary Tube Suitable For Window / Splittype Ac 1.5 / 2.0 Ton Capacity All As Specified And Directed. 210 Supply And Fixing In Replacement Ofstarting Relay Unit Suitable For Refrigerator 165 / 286 / 310 Litres Capacity All As Specified And Directed. 211 Supply And Fixing In Replacement Ofgas Strainer For Refrigerator All As Specified And Directed. 212 Supply And Fixing In Replacement Of Refrigerator Stand Suitable For Refrigerator Of Various Capacity And Make All As Specified And Directed. 213 Supply And Fixing In Replacement Ofover Load Protection Relay Unit Suitable For Deep Freezer 286 / 310 Litres Capacity All As Specified And Directed. 214 Opening To Refrigerator Freezer Of Capacity 165 To 320 Ltr Re-Fixing The Same After Flushing Out And Removal Of Blockage Brazing Replacement Of Liquid Line, Filtercomplete All As Specified And As Directed 215 Taking Down To Fake Coloured Refrigerator Of Capacity 210 To 320 Ltrand Scrapingto Existing Colour Completely And Painted With Two Coat Of Synethic Enamel Paintover A Coat Of Red Oxide Primer After Filing The Cavities With Filler To Ms Sheet And Inner Surface Of Bottomand Sides Shall Be Painted With One Coat Of Synetic Enamel Paint Over One Coat Of Primer Complete All As Specified And As Directed 216 Repair / Servicing / Cleaning Of Packaged Air Conditioner Water Cooled Of Cap 8.75 Tr Including Cooling Tower, Pressure Guage, Connected Water Supply Line, Butterfly Valves, Gate Valves, Evaporation Fan Motor, Compressor, Conduncing Motor, Heater, Automation Panels. Induction Motors, Control Switch Gears & Other Electrical Eqpts Of Main Electric Panels, Contactors, Etc. Including Cleaning Of Filters, Shafts And Bearing Alignment And Cleaning Of Cooling Coils And Necessary Repairs To Keep The System Functioning Properly According To The Parameters By Authorized Service Agent All As Directed By Engr-In-Charge.Note :- Repairs / Spares Partswill Be Measured And Paid Separately Under Respective Items Complete All As Specified And As Directed . 217 Recharging Of Gas R-22 In Packaged Air Conditioner Water Cooled Of Cap 8.75 X 2Tr Complete Including Testing Of Leakage And Testing The Unit For Satisfactory Performance Complete All As Specified And As Directed. 218 Taking Down Carefully Ceiling / Exhaust / Wall Mounted Fans ( Of Any Size / Make ) From Site To Mes Store Yardcompleteall As Specified And As Directed. Note :- Transportation For Ceiling Fan From Site To Mes Store Yard And Vicevarsa After Repair Incl In This Quoted Rate.No Extra Payment Will Be Made For It. 219 M&Lin Replacement For Rewinding Toceiling Fan Motor Of1200mm Sweep Any Make Windedwith Winding Machinewith Super Enameled Copper Winding Wire Of Existing Size Includinginsulated Sleeves& Paper , Varnishing With ‘B’ Class Insulation Varnish Thimbles, Connection With Flexible Cableof Copper Conducor Of Size 23 / .0076Upto Connector Block ( Winding Wireexc 300 Gm And N-Exc 350Gm ) Complete All As Specified And As Directed 220 M&L In Replacement For Rewinding Toceiling Fan Motor Of1400 / 1500Mm Sweep Any Make Windedwith Winding Machinewith Super Enameled Copper Winding Wire Of Existing Size Includinginsulated Sleeves& Paper , Varnishing With ‘B’ Class Insulation Varnish Thimbles, Connection With Flexible Cableof Copper Conductor Cable Of Size 23 / .0076Upto Connector Block ( Winding Wireexc 350 Gm And N-Exc 750Gm ) Completeall As Specified And As Directed By Engineer-In-Charge.Note For Item No 219 & 220 :-- ( I ) The Cost Of Cutting & Taking Out To Existing Old Winding Wire Shall Be Deemed Tobe Included In The Unit Rate Of This Item. Nothing Extra Shall Beentertained On This Account ( Ii ) Spare Parts Like As Ball Bearings, Bush & Shaft Shall Be Measured &Paid Seperatly Under Respective Item No 221 To 223 Of This Schedule . Fixing Charges Of These Spare Parts Shall Be Deemed To Be Included In The Unit Rate Of This Item Without Entertaining Extra Cost On This Account Complete All As Specified And As Directed 221 Supply & Fixing In Replacementof Ball Bearing Suitable For 1200 / 1400 / 1500 Mm Sweep Any Make Ceiling Fans Complete All As Specified And As Directed 222 Supply & Fixing In Replacementof Gun Metal Bushsuitable For 1200 / 1400 / 1500 Mm Sweep Any Make Ceiling Fans Complete All As Specified And As Directed 223 Supply & Fixing In Replacementof Mild Steel Shaft Suitable For 1200 / 1400 / 1500 Mm Sweep Any Make Ceiling Fans Complete All As Specified And As Directed 224 M&L In Rewinding Of Exhaust / Pedestal / Wall Mounting Fan Motor Of225 To 300Mm Sweep Any Make Winded With Winding Machinewith Super Enameled Copper Winding Wire Of Existing Size Includinginsulated Sleeves , Paper , Varnishing With ‘B’ Class Insulation Varnish, Thimbles, Connection With Flexible Cableof Copper Conductor Of Size 23 / .0076 Up-To Connector Blockcomplete All As Specified And As Directed. 225 All As Per Above Item No 224 Here-In –Before But350 / 450 Mm Sweep.Note For Item No 224 & 225 :-- ( I ) The Cost Of Cutting & Taking Out To Existing Old Winding Wire Shall Be Deemed Tobe Included In The Unit Rate Of This Item. Nothing Extra Shall Beentertained On This Account ( Ii ) Spare Parts Like As Ball Bearings, Bush & Shaft Shall Be Measured & Paid Separately Under Respective Item No 226 To 228 Of This Schedule . Fixing Charges Of These Spare Parts Shall Be Deemed To Be Included In The Unit Rate Of This Item Without Entertaining Extra Cost On This Account Complete All As Specified And As Directed 226 Supply & Fixing In Replacementof Ball Bearing Suitable For 225 / 300 / 350 / 450 Mm Sweepexhaust / Pedestal / Wall Mounting Fan Complete All As Specified And As Directed. 227 Supply & Fixing In Replacementof Gun Metal Bushsuitable For 225 / 300 / 350 / 450 Mm Sweepexhaust / Pedestal / Wall Mounting Fan Complete All As Specified And As Directed. 228 Supply & Fixing In Replacementof Mild Steel Shaft Suitable For 225 / 300 / 350 / 450 Mm Sweepexhaust / Pedestal / Wall Mounting Fan Complete All As Specified And As Directed. 229 M&L For Lath Work To Any Type Of Fan For Taking Out Bush From The Lower Body Part Of Ceiling Fan And Replacing It With Suitable Size Of Ball Bearingas Per Matching Size To Shaft Making Necessary Bearing Boring, Cutting, Greasing, Polishing Of Shaft Completeall As Specified And As Directed By Engineer-In-Charge. Note : - Supply And Fix To Bearing Shall Be Measured And Paidseparately Under Respective Item Of This Schedule 230 Supply And Fixing Of Wall Mounting Fan 400 Mm Sweep Size, Double String Type And Making All Electric Connections Including Fixing Accessories Complete All As Specified And Directed. 231 Supply & Fixing In Replacementof Dry Type 4 Mfd Suitable For 240 Volt Acfor Exhaust Fancompleteall As Specified And As Directed . 232 Supply & Fixing In Replacementof Capacitor Oil Type 2.5 / 3.15 Mfd Suitable For 240 Volt Ac For Ceiling Fan Completeall As Specified And As Directed . 233 S&F Of Ventilatingfan 250 Mm Sweep Metal Type Incuding Self Cosing Louver And Making All Electric Connections Complete All As Specified And Directed. Make: Havells / Cg / Ge 234 M&L For Painting To Ceiling Fan 1200 / 1400 / 1500Mm Sweep & Exhaust / Pedestal / Wall Mounting Fan Motor Of225 / 300 / 350 / 450 Mm Sweepincl Preparation Tosurfaces, Cleaning Thoroughly With Kerosene Oilto Remove Oily Dust And Any Type Of Spots Etc And Painted Withone Coatsynthetic Enamelpaint ( White Colour ) With Help Ofspray Gunmachine Complete All As Specified And As Directed. 235 Supply & Fixing In Replacementof Fan Blades Ofsuitable For1200 / 1400 / 1500Mm Sweep Fan ( Set Of Three Blades ) Of Existing Make Complete All As Specified And As Directed 236 Supply & Fixing In Replacementofm.S Rod 1Ft / 2Ft Long As Per Site Requirement Including Clamp, Nut & Split Pin Suitable For1200 / 1400 / 1500Mm Sweep Fancomplete All As Specified And As Directed 237 Supply & Fixing In Replacementofrubber Real Suitable For 1200 / 1400 / 1500Mm Sweep Fan Completeall As Specified And As Directed 238 Supply And Fixingof Exhaust Fan 300 / 380 Mm Sweep Heavy Duty Complete With Self Closing Ms Louvers, Mounted In Suitable Opening Arrangement And Suitable For Operation On 230 Volts Single Phase, 50 Hz, 1400 Rpm , Ac Supply With And Including Two Core Pvc Insulated, Pvc Sheathed Copper Conductor Flexible Cable 24 / 0.2 Mm And Making All Necessary Connection And Fixed By Using 4 Nos 100 Mm Long 10 Mm Dia Bolts, Nuts And Washers And Grouted In Wall In Cm 1:3 ( Including Opening Of Walletc ) Completed All As Directed. Make: Polar Note: The Cost Of Making Hole In The Existing Wall And Making Good The Disturbed Surface Of Wall Etc. As Original Ie Brick Work, Plastering, White Washing Etc Is Included In This Quoted Rate. 239 Supply And Fixing In Replacement Of Water Cooler Tray , Drain Pipe Including Self Closing Tape Complete All As Specified And Directed. 240 S&F Forpcb Suitable For Washing Machine 7 Kg Cap Incl Taking Down Old Unsv Complete All As Directed. 241 S&F For Display Pcb Suitable For Washing Machine 7 Kg Cap Incl Taking Down Old Unsv Complete All As Directed. 242 S&F For Water Pressure Sensorofwashing Machine 7 Kg Cap Incl Taking Down Old Unsv Complete All As Directed. 243 S&F For Drain Pumpofwashing Machine 7 Kg Cap Incl Taking Down Old Unsv Complete All As Directed. 244 S&F For Directdrain Motor Ofwashing Machine 7 Kg Cap Incl Taking Down Old Unsv Complete All As Directed. 245 Supply And Fixing In Replacement Of3 Phase Blower Motor Suitable For 8.75 Ton Split Package Type Ac Including Taking Down Existing Old Unserviceable Motor Complete All As Specified And Directed. 246 Supply And Fixing In Replacement Of Condenser Fan Motor 230 Volt, Three Phase For 8.75 Ton Split Package Type Ac Including Taking Down Existing Old Unserviceable Condenser Fan Motor Complete All As Specified And Directed. 247 Supply And Fixing In Replacement Of V-Belt A-32 For 8.75 Ton Split Package Type Ac All As Specified And Directed.Make: ( Poly-F ) Plus A-26. 248 Supply And Fixing In Replacement Ofblower Motor Bearing Size For 8.75 Ton Split Package Type Acall As Specified And Directed. 249 Supply And Fixing In Replacement Of Three Phase Contactor Avi-18 For 8.75 Ton Split Package Type Ac All As Specified And Directed. 250 Supply And Fixing In Replacement Of Remote Sensor Display For 8.75 Ton Split Package Type Ac Plantall As Specified And Directed. 251 Supply And Fixing In Replacement Of Condenser Fan Bladefor 8.75 Ton Split Package Type Ac Plantall As Specified And Directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Sep-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
INR 42.50 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail