Military Engineer Services-MES has published Comprehensive Repair Maint Of Submersible Pump Booster Pumps Starter Panels Cables And Connected Items Under Ge N Akhnoor . Submission Date for this Tender is 10-09-2022. Starter Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 03-Sep-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-09-2022 |
Sl. No. | Item Description |
1 | Material and labour in replacement of LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm imbedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed,The panel should be IS/IEC 61439-I&II- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. (Note: Panel shall be a front/rear opening with cable entry from the bottom).Make of Panel:Make: Legrand/L&T/Siemen. |
2 | (a)MCCB 200 Amps,thermal adjustable and magentic setting havingrupturing capacity 36 KA (Ics= 100% Icu) , TP, 415 volts, 50 Hz,along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. |
3 | (b) Supply, installation, testing and commissioning of Soft Starter 100 H.P. |
4 | (c) Supply, installation, testing and commissioning contactors, relays, CT timers, for suitable rating having with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM along with contactor & semiconductor fuses with , Control Fuse etc fitted in Panel board for showing V, I, Hz, Pf all as specified and directed. |
5 | Taking down the 220 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. Note for srl item No 1 to 6 (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate,greese lubrication to bearing bushes ets are deemed to be included and supply only bearings and terminal plates will be measured and paid separetly under respective items. |
6 | Taking down the 125HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
7 | Taking down the 100HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
8 | Taking down the 75HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
9 | Taking down the 60HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
10 | Taking down the 50 HP 3 phase 415 volt capacity motor from base plate/pump after disconnecting,and rewinding with super enamelled copper wire of best quality of existing size/guage and weight includingreplacement of insulation material ,varnish,bearing,connection plate and all other petty items required to motor functional and reassembling the motor incl installation,commissioning and testing on full load all as specified and directed. |
11 | Supply only the following parts for incorporating initem No1 to 6 here in before:- 220 HP motor bearings as per sample Make SKF/NBC |
12 | 125 HP motor bearings as per sample Make SKF/NBC |
13 | 100HP motor bearings as per sample Make SKF/NBC |
14 | 75 HP motor bearings as per sample Make SKF/NBC |
15 | 60 HP motor bearings as per sample Make SKF/NBC |
16 | 50 HP motor bearings as per sample Make SKF/NBC |
17 | Terminal plate with brass nuts, washers suitable for 3 phase 220 HP Motor |
18 | Terminal plate with brass nuts, washers suitable for 3 phase 125 HP Motor |
19 | Terminal plate with brass nuts, washers suitable for 3 phase 60 HP Motor |
20 | Material and labour in replacement of LT Panel Board, indoor type of suitable size as per relevent IS, mounted on angle iron legs of size 40x40x6mm embedded in PCC 1:2:4 block type B-2 (using 40 mm graded aggregates) at pump house, floor mounting, dust and vermin proof, factory made (CPRI approved), fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase, 415 Volt, 50HZ AC Supply, busbar chamber with aluminum busbar of suitable amp rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in grey colour all as specified & directed,The panel should be IS/IEC 61439-I- TTA. The Panel builder should submit Test Certificate along with GA drawing before executing the job. (Note: Panel shall be a front/rear opening with cable entry from the bottom). |
21 | Make of Panel:Make: Legrand/L&T/ABB. (a)MCCB 160 Amps,thermal adjustable and magentic setting havingrupturing capacity 36 KA (Ics= 100% Icu) , TP, 415 volts, 50 Hz,along with Extended Ratory handle ,Spreader terminal and phase barrier - 01 No. (b) Supply, installation, testing and commissioning of Soft Starter 60 H.P. (c) Supply, installation, testing and commissioning contactors, relays, CT timers, for suitable rating having with ON, OFF , Trip Indicating Light, Push Buttons, Digital MFM along with contactor & semiconductor fuses with , Control Fuse etc fitted in Panel board for showing V, I, Hz, Pf all as specified and directed. |
22 | Dismantling and Taking down centrifugal pumpset from platform and disconnecting suction and delivery pipe line and electrical connections, transport the same to workshop for repair and after repairing transporting the pumpset from workshop to site , installation at site connecting suction and delivery pipe and electrical connection complete all as directed by Engineer-in-charge for 220 HP pump capacity Note :(i) The rate is deemed to be included the cost of providing foundation nuts,bolts and washers gland packing, greasing,oiling and oil sheet gasket (ii) The spare parts will be measured and paid separately under relevant items of supply only. |
23 | All as per Srl item No. 10 above but of capacity 100 to 125 HP. |
24 | All as per Srl item No. 10 above but of capacity 100HP. |
25 | All as per Srl item No. 10 above but of capacity 50 to 75 HP. |
26 | Supply only the following parts for incorporating in item for 220HP Capacity centrifugal pumpset (i) Bronze impeller |
27 | casing ring |
28 | impeller ring brass nut |
29 | impeller key |
30 | coupling key |
31 | coupling rubber bushes |
32 | shaft sleeve(steel) |
33 | Bearing |
34 | Shaft(steel) |
35 | Brass bush |
36 | Gland bolt/nut |
37 | Supply only the following parts for incorporating in item for 125HP Capacity centrifugal pumpset, complete all as specified & directed. Bronze impeller |
38 | casing ring |
39 | impeller ring brass nut |
40 | impeller key |
41 | coupling key |
42 | coupling rubber bushes |
43 | shaft sleeve(steel) |
44 | Bearing |
45 | Shaft(steel) |
46 | Brass bush |
47 | Gland bolt/nut |
48 | Supply only the following parts for incorporating in item for 100HP Capacity centrifugal pumpset Bronze impeller |
49 | casing ring |
50 | impeller ring brass nut |
51 | impeller key |
52 | coupling key |
53 | coupling rubber bushes |
54 | Shaft sleeve(steel) |
55 | Bearing |
56 | Shaft(steel) |
57 | Brass bush |
58 | Gland bolt/nut |
59 | Supply only the following parts for incorporating in item for 50/75HP Capacity centrifugal pumpset Bronze impeller |
60 | casing ring |
61 | impeller ring brass nut |
62 | impeller key |
63 | coupling key |
64 | coupling rubber bushes |
65 | shaft sleeve(steel) |
66 | Bearing |
67 | Shaft(steel) |
68 | Brass bush |
69 | Gland bolt/nut |
70 | Lifting the submersible pump from the existing bore hole/tube well for repairs complete including disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts, washers, rubber flanges etc and taking out the submersible pump set of capacity 60 to 75 HP with column pipes of size 80/100/150 mm bore and two runs of submersible cable and stacking properly for reuse and lowering complete in borewell afterrepair from workshop, rejointing each column pipe, submersible cable connection, testing, complete all as specified & directed. Note (i) Transportation charges from installation to contractor workshop and back after repair are deemed to be included in the unit rate quoted for above item (ii) Cost of nuts, bolts, washers,connection plate,greese lubrication to bearing bushes ets are deemed to be included and supply onlyrelevant parts of pumps and motorswill be measured and paid separetly. |
71 | All as per Srl item No. 18 above but of capacity 41 to 55 HP. |
72 | Supply only following parts for submersible pumpset (i) Impeller brass suitable for 60 HP |
73 | (ii) Impeller brass suitable for 41HP |
74 | (iii) Stage bowl suitable for 60HP |
75 | (iv) Stage bowl suitable for 41HP |
76 | (v) Bowl fixing steel nut and bolt for 60 HP |
77 | (vi) Bowl fixing steel nut and bolt for 41 HP |
78 | (vii) Bearing sleeve suitable for 60 HP |
79 | (viii) Bearing sleeve suitable for 41 HP |
80 | (ix) Bearing bush suitable for 60 HP |
81 | (x) Bearing bush suitable for 41 HP |
82 | (xi) Neck ring suitable for 60 HP |
83 | (xii) Neck ring suitable for 41 HP |
84 | (xiii) Casing wear ring suitable for 60 HP |
85 | (xiv) Casing wear ring suitable for 41 HP |
86 | (xv) Shaft steel for 60 HP Pump |
87 | (xvi) Shaft steel for 41 HP Pump |
88 | (xvii) Strainer suitable for 60 HP |
89 | (xviii) Strainer suitable for 41 HP |
90 | (xix) Stage gasket for suitable for 60 HP |
91 | (xx) Stage gasket for suitable for 41 HP |
92 | Rewinding of AC 3 phase submersible motor of capacity 60 HP by cutting of burnt out winding,cleaning of starter slots, cleaning,bleaching of motor and rewinding with appropriate guage of copper winding wire complete including all required parts complete all asspecified and directed. Note Taking down of unsv parts and fixing the same with new ones will be taken under relevant items hereafter |
93 | Rewinding of AC 3 phase submersible motor of capacity 41 HP by cutting of burnt out winding,cleaning of starter slots, cleaning,bleaching of motor and rewinding with appropriate guage of copper winding wire complete including all required parts complete all as specified and directed. |
94 | Supply only the following parts of motor of submersible pumpset: (i) Thrust bearing plate suitable for 60 HP |
95 | (ii) Thrust bearing plate suitable for 41 HP |
96 | (iii) Motor bearing bush suitable for 60 HP |
97 | (iv) Motor bearing bush suitable for 41 HP |
98 | (v) Assembly for coupling sleeve suitable for 60 HP |
99 | (vi) Assembly for coupling sleeve suitable for 41 HP |
100 | (vii) Drain plug for 60 HP motor |
101 | (viii) Drain plug for 41 HP motor |
102 | (ix) Sand guard for 60 HP |
103 | (x) Key for thrust plate for 60HP |
104 | (xi) Key for thrust plate for 41HP |
105 | MCCB of capacity 400 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S adustable type fixed in existing panel board including modification for new MCCB, all jointing/connecting materials and dismantling of old unserviceable MCCB,complete all as specified & directed. Make- Havells/L&T./Siemen |
106 | MCCB of capacity 250 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S adustable type fixed in existing panel board including modification for new MCCB, all jointing/connecting materials and dismantling of old unserviceable MCCB,complete all as specified & directed. Make- Havells/L&T./Siemen |
107 | MCCB of capacity 160 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S adustable type fixed in existing panel board including modification for new MCCB, all jointing/connecting materials and dismantling of old unserviceable MCCB,complete all as specified & directed. Make- Havells/L&T./Siemen |
108 | MCCB of capacity 250 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S Adustable type, fixed in existing panel board including modification for new MCCB, all jointing/connecting materials and dismantling of old unserviceable MCCB,complete all as specified & directed. Make- Havells/L&T./Siemen |
109 | MCCB of capacity 160 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S Adjustable type fixed in existing panel board including modification for new MCCB, all jointing/connecting materials and dismantling of old unserviceable MCCB,complete all as specified & directed.Make- Havells/L&T./Siemen |
110 | Scrapping existing painting of pumpset of capacity 220 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint ASIAN, BERGER |
111 | Scrapping existing painting of pumpset of capacity 125 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint ASIAN, BERGER |
112 | Scrapping existing painting of pumpset of capacity 100 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint ASIAN, BERGER |
113 | Scrapping existing painting of pumpset of capacity 75 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint ASIAN, BERGER |
114 | Scrapping existing painting of pumpset of capacity 50/60 HP incl painting of steel base structure, exposed suction/delivery pipe, valve header complete with emery paper/ wire brush and repaintingwithtwo coat of synthetic enamel paint ofcolour approved by Engr-in-charge all as specified and directed. Make of paint ASIAN, BERGER |
115 | Supply and fixing vinyl display board frame size 6"x4"showing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installationall as specified and directed by Engr-in-charge. |
116 | Supply and fixing acrylic sheet display board frame size 3"x2"showing schematic diagram of electric/water supply distribution network as sketch provided to be fixed on walls in installationall as specified and directed by Engr-in-charge. |
117 | Material and labour for retro reflectiveinstallation sign board size 6ft x4 ft fabricated out of 1.6mm MSsheet frame welded/riveted with stainless steel pipe finished in square of size 25mmx25mm at 2.5m height from ground level on stainless steel finished pipe of size 50mm fixed with PCC 1:2:4 Type B-1 of block size 45cmx45cmx60cm.The board shall be painted in stove enamelled paint and the front and back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The writting matter will be in English language on both sides with reflective adhesive painter tape all as specified and directed. |
118 | Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundationof pole and laying of HT cable as in soft/loose soil and getting out complete all as specified and directed. |
119 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
120 | M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint |
121 | M&L for Cement concrete infilling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type C-2 1:3:6 (40 mm graded aggregate) complete all as specified and directedby Engr-in-Charge. |
122 | M&L for Cement concrete infilling and mass concrete/ Coping of Poles and PCC for road crossings etc all as directed , type C-1 1:3:6 (20 mm graded aggregate) complete all as specified and directed by Engr-in-Charge. |
123 | Taking down old unsv PCC poles and M&L for steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx 300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping, complete all as specified and directed. |
124 | Taking down old/unsv flood lights from high mast light of any type and M&L for LED flood light of capacity 250 watt IP 66 Lumainire with aluminium die cast housing toughened glass and unique lens system for enhancement illuminationcomplete with all accessories Make Wiprocat part No LF3 -342-060-57XXor equivalent in specification of make phillips, Oshram,wipro, GE |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail