}

Construction Of New I.T. Block In Post Graduate Govt. College, Sector 46, Chandigarh ( Under Rusa Grant ) . ( Composite Work ) ., chandigarh-Chandigarh

Chandigarh Administration Engineering Department has published Construction Of New I.T. Block In Post Graduate Govt. College, Sector 46, Chandigarh ( Under Rusa Grant ) . ( Composite Work ) .. Submission Date for this Tender is 15-09-2022. Civil Work Tenders in chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

33471400
Corrigendum : Construction Of New I.T. Block In Post Graduate Govt. College, Sector 46, Chandigarh ( Under Rusa Grant ) . ( Composite Work ) .
Open Tender
Indian
Chandigarh
chandigarh
15-09-2022

Tender Details

Construction Of New I.T. Block In Post Graduate Govt. College, Sector 46, Chandigarh ( Under Rusa Grant ) . ( Composite Work ) .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Aug-2022 CONSTRUCTION OF NEW I.T. BLOCK IN POST GRADUATE GOVT. COLLEGE, SECTOR 46, CHANDIGARH (UNDER RUSA GRANT). (COMPOSITE WORK). Date 25-08-2022
2 25-Aug-2022 Date Extend Date 02-09-2022
3 31-Aug-2022 Date Amended Date 09-09-2022
4 08-Sep-2022 Date Extended Date 15-09-2022
5 13-Sep-2022 Regarding Bidding Capacity Technical Bid 15-09-2022

Key Value

Document Fees
Refer document
EMD
INR 1530318.0 /-
Tender Value
INR 7.65 Crore /-

BOQ Items

Name of Work:CONSTRUCTION OF NEW I.T. BLOCK IN POST GRADUATE GOVT. COLLEGE, SECTOR 46, CHANDIGARH (UNDER RUSA GRANT). (COMPOSITE WORK).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
2All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
4Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
5All kinds of soil
6Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
81:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
101:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
11Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
12Centering and shuttering including strutting, propping etc. and removal of form for :
13Foundations, footings, bases of columns, etc. for mass concrete
14Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
15Suspended floors, roofs, landings, balconies and access platform
16Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Columns, Pillars, Piers, Abutments, Posts and Struts
18Edges of slabs and breaks in floors and walls
19Under 20 cm wide
20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
21Thermo-Mechanically Treated bars
22Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
23Thermo-Mechanically Treated bars of grade Fe-500D or more.
24Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
25Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
26All works upto plinth level
27Concrete of M25 grade with minimum cement content of 330 kg /cum
28Concrete of M40 grade with minimum cement content of 390 kg/cum
29Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
30All works above plinth level upto floor V level
31Concrete of M25 grade with minimum cement content of 330 kg /cum
32Concrete of M35 grade with minimum cement content of 370 kg /cum
33Concrete of M40 grade with minimum cement content of 390 kg /cum
34Add for using extra cement in the items of design mix over and above the specified cement content therein.
35Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
36Cement mortar 1:6 (1 cement : 6 coarse sand)
37Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
38Cement mortar 1:4 (1 cement : 4 coarse sand)
39Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
40Cement mortar 1:4 (1 cement :4 coarse sand)
41Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
42Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
43Granite of any colour and shade
44Area of slab over 0.50 sqm
45Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
46Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
47Sal wood
48Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
49Kiln seasoned and chemically treated hollock wood
5030 mm thick
51Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
52Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
5335 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
54Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
55Fixed to steel windows by welding
56Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
57250x16 mm
58Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
59200x10 mm
60150x10 mm
61Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
62125 mm
63Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.
64250 mm weighing not less than 280 gms
65Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
66Profile C
67Fixing with adjustable lugs with split end tail to each jamb
68Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
69In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
70Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
71Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement:4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
72Glazed Vitrified tiles Matt/Antiskid finish of size
73Size of Tile 600 x 600 mm
74Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
75Udaipur green marble
76Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre.
7740 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.
78Red sand stone
79Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
80In 75x75 mm deep chase
81Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
82Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
83Coupler
84110 mm
85Shoe (Plain)
86110 mm Shoe
87Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes:
88110 mm diameter
89Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
90Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
9112.5 mm thick tapered edge gypsum moisture resistant board
9212 MM CEMENT PLASTER MIX
931:6 (1 cement: 6 fine sand)
9415 mm cement plaster on the rough side of single or half brick wall of mix :
951:4 (1 cement: 4 fine sand)
966 mm cement plaster of mix :
971:3 (1 cement : 3 fine sand)
98Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.
99Two or more coats on new work
100Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
101Two or more coats on new work
102Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
103Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
104With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
105Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
106Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
107Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)
108Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall bemooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) :
109For fixed portion
110Powder coated aluminium (minimum thickness of powder coating 50 micron)
111Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water+C1446 curing for 48 hours. The rate includes preparation of surface, treatment and sealing of alljoints, corners, junctions of pipes and masonry with polymer mixed slurry.
112Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
113(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
114(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
115With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
116Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
117Providing Udaipur Green Marble stone flooring with 15-18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.
118Providing and fixing centre mullion memberconforming to IS : 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, mild steel angle of section 50x25 mm single rebate rigidly fixed together by mechnaically means and applying a coat of primer of approved brand & manufacturrer. in all respect and entire satisfaction of Engineer-in-charge.
119Providing and fixing 5.5 cm brick daily facing at all heights to be obtained after cutting from F.P.S (non modular) bricks of class designation 10 having size of 23cm X 11.5 cm X 7.5cm laid in 12mm thick cement sand mortar 1:3 on RCC beams, lintels and fascias etc. complete in all respects as per architectural drawings and to the entire satisfaction of Engineer-in-charge.
120Providing and fixing extra granite strip 50mm wide at bottom of nozing with edge moulding on bottom side with adhesive and filling of joint with white cementand matching pigment complete in all respect to the entire satisfaction of Engineer-in-Charge.
121Providing and fixing asbestos cement sheet strips 50 mm x 6mm for conglomerate / terrazzo floors complete fixed in position to the entire satisfaction of Engineer-in-charge. (NS)
122Providing and Fixing chicken mesh of size ½"x½" and 24 gauge up to 15m height on RCC beams, facias, brick work etc. wherever required with wooden gutties, nails and screws including drilling holes etc complete as per directions of the Engineer-in-charge.
123Providing and filling with dry brick ballast under floor in depressed portion ofslab of toilets, including watering, ramming, consolidating and dressing upto floor V complete.
124Providing, assembling, fixing and supplying vision glass panels i.e. heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface. The glass panel should be coloured tinted and covered with reflective soft coating; having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by Engineer-in-charge as per the site requirement. the rate includes the cost of weather silicone sealant, providing grooves etc. complete in all respect. The cost includes cleaning and protection of the glass system till the handing over of the building for occupation. Further, contractor shall provide a water tight structural glazing system all complete as required by Engineer-in-charge. For payment, only the actual area of glass on face of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
125PUBLIC HEALTH (SANITARY INSTALLATION)
126Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
127All kinds of soil.
128Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
129All kinds of soil
130Pipes, cables etc, not exceeding 80 mm dia.
131Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
132Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1331:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1341:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
1351:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
136Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
137Centering and shuttering including strutting, propping etc. and removal of form for :
138Suspended floors, roofs, landings, balconies and access platform
139Edges of slabs and breaks in floors and walls
140Under 20 cm wide
141Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
142Thermo-Mechanically Treated bars of grade Fe-500D or more.
143Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
144Cement mortar 1:4 (1 cement : 4 coarse sand)
145Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
14612 mm cement plaster
147Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings &C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
148W.C. pan with ISI marked white solid plastic seat and lid
149Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
150Providing and fixing soil, waste and vent pipes :
151100 mm dia.
152Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
15375 mm diameter :
154Centrifugally cast (spun) iron socketed pipe as per IS: 3989
155Providing and fixing heel rest sanitary bend
156100 mm dia
157Sand cast iron S&S as per IS - 3989
15875 mm dia
159Sand cast iron S&S as per IS - 3989
160Providing & fixing single equal plain junction of required degree :
161100x100x100 mm
162Sand cast iron S&S as per IS - 3989
16375x75x75 mm
164Sand cast iron S&S as per IS - 3989
165Providing & fixing terminal guard :
166100 mm
167Sand cast iron S&S as per IS - 3989
16875 mm
169Sand cast iron S&S as per IS - 3989
170Providing and fixing collar:
171100 mm
172Sand cast iron S&S as per IS - 3989
17375 mm
174Sand cast iron S&S as per IS - 3989
175Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :
176100 mm
17775 mm
178Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
179100 mm inlet and 75 mm outlet
180Sand cast iron S&S as per IS - 3989
181Providing and fixing PTMT Bottle Trap for Wash basin and sink.
182Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
183Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
184Internal work - Exposed on wall
18525 mm dia nominal bore
18632 mm dia nominal bore
18750 mm dia nominal bore
188Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18915 mm dia nominal bore
19020 mm dia nominal bore
191Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
192External work
19350 mm dia nominal bore
194Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
19525 mm nominal bore
19620 mm nominal bore
19732 mm nominal bore.
19850 mm nominal bore
199Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20025 mm nominal bore
201Providing and fixing uplasticised PVC connection pipe with brass unions :
20245 cm length
20315 mm nominal bore
204Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
20520 mm nominal bore
20625 mm nominal bore
20732 mm nominal bore
20850 mm nominal bore
209Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
210Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
211Cutting holes up to 30x30 cm in walls including making good the same:
212With common burnt clay F.P.S. (non modular) bricks
213Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
214150 mm diameter
215200 mm diameter
216Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
217150 mm diameter S.W. pipe
218200 mm diameter S.W. pipe
219Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
220100x100 mm size P type
221With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
222Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
223L D- 2.5
224Rectangular shape 600x450 mm internal dimensions
225H D - 20
226Circular shape 560 mm internal diameter
227Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
228For pipes 100 to 250 mm diameter
229NSR Items
230Providing drip seal/ M-Seal joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter.
231100 mm
23275 mm
233Providing and fixing in position toilet front panel comprising door with left right supporting panels made of heat, bacteria, water, chemical, scratch proof and impact resistant 12mm thick solid high pressure compact laminate panels of end, Mid & door conforming per IS 2046 of Greenlam/ Merino/ or equivalent including door pilasters & inetmediate panels finished with approved texture/ shade comprising assesories & handwares made out od Anodised Alluminium(Grade 6063- T6) & SS-304 Grade with Alluminium supporting system with following complete in all respect as per drawing.
234Providing & fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap,controlled flush, low level cistern (dual flush type) made of vitreous china with all fittings complete including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
235White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
236Providing and fixing ofCounter wash basin including CP Waste of approved Make / Model as approved by EIC.
237Providing and fixing ofWash basin with pedestalwith C.I. brackets , 32mm CP brass waste of standard pattren ,including painting of fittings and brackets cutting and making good the walls whereever require complete in all respect of make CERA Model Concord or equivalent model of any other approved make. (Size 630 x 450mm)
238Providing & fixing white vitreous china flat back half stall urinal of size 420 x 395 x 635mm with fittings, standard size C.P. brass flush pipe, spreadersand clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required Make CERA Model CARAMINA or equivalent model of any other approved make.
239Providing and fixing of urinal partition toughen glass Complete in all respect. Make as approved by EIC. (Size Height 900 mm x Width 450mm)
240Providing & fixing Urinal Valve Auto Closing System with Built-in Control Cock with Wall Flange ( Pressmatic Type ) of approved Make / Model as approved by EIC.
241Providing & fixing C.P.Short Body Bib Cock with wall flange complete of approved Make / Model as approved by EIC.
242Providing & fixing C.P. Angular Stop Cock with wall flange complete of approved Make / Model as approved by EIC.
243Providing & fixing CP Pillar Cock with Auto Closing System ( Pressmatic ) of approved Make / Model as approved by EIC.
244Providing & fixing Acrylic Soap Dispenser complete in all respect of approved Make / Model as approved by EIC.
245Providing & fixingof CP Towel Ring of Make / Model as approved by EIC
246Providing & fixing 5 mm thick looking glass with PVC frame beading including cost of screws, rawal plugs complete in all respects make as approved by EIC
247Providing & fixing of SS grab rail of 304 Grade ISI of 50mm dia complete in all respect of approved Make / Model as approved by EIC.
248Providing andfixing UPVC pipe Medium Class, IS 4985 marked including all ncessary fittings, solvent complete in all respect as per entire satisfaction of EIC
249110 mm OD
250Providing and fixing of CP Bottle Trap for Wash Basins, and Urinals complete of make CERA, Jaquar, Hindware
251Providing and fixing of CI P Trap for Urinals complete in all respects of size 75 mm of approved make
252Sub Head - II
253Supplying Installing Testing and Commissioning of Water Cooler having following specifications, conforming to IS 1475 Part 1 of approved make: Climatrol, Usha, Blue Star
254Storage Capacity: 150 Ltr
255Cooling Capacity: 150 LPH (Min)
256Material Tank: SS 304, Body: SS 304, Body: SS
257Refrigerant: CFC Free
258Supplying and Fixing of water purifier with 3 stage purification system consisting of sediment filter, activated carbon filter and Ultravoilet treatment having purification capacity of 200 LPH, Water Control Sensor for automatic control of purifier as per level of water cooler and valve for back flushing of sediment filter complete in all respect. Make: Aquaguard, Kent, Usha, Brita, Pure-it, A-Pure etc. to the entire satisfaction of EIC.
259Providing and Fixing of 4 KVA Voltage Stablizer (For Water Cooler) Copper Winding Range 160-280 Volt with timer MCB, Volt Meter, Amp Meter & 22 G Powder Coated Body complete in all respects to the entire satisfaction of EIC Make. Deol, Logic, State, Jewel.
2604 KVA
261Providing and Fixing of angle iron stand for Water Cooler of the angle of size 50 x 50 x 5 including cutting, welding, primer and synthetic enamel painting two coats of required color after one coat of primer complete in all respect.
262PUBLIC HEALTH (FIRE FIGHTING SYSTEM)
263Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
264All kinds of soil.
265Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating eachdeposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
266All kinds of soil
267Pipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
268Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
2691:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
270Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
271Centering and shuttering including strutting, propping etc. and removal of form for
272Foundations, footings, bases of columns, etc. for mass concrete
273Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
274Cold twisted bars
275Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
276Cement mortar 1:4 (1 cement : 4 coarse sand)
27712 mm cement plaster finished with a floating coat of neat cement of mix :
2781:3 (1 cement: 3 fine sand)
279Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
280Internal work - Exposed on wall
28125 mm dia nominal bore
28232 mm dia nominal bore
283Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
28425 mm nominal bore
28532 mm nominal bore
286Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
28725 mm nominal bore
288Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
28925 mm nominal bore
29032 mm nominal bore
291WATER STORAGE TANK AT TERRACE (FOR FIRE FIGHTING)
292Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
293Cutting holes up to 30x30 cm in walls including making good the same:
294With F.P.S. bricks
295Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
296Supplying laying fixing testing and commissioning of following Sizes(NB) of ISI marked heay class M.S. pipes including cuttings threading,welding etc. and providing all fittings e.g. elbows, reducers clampshangers flanges gaskets nuts bolts and washers etc including painting of pipes and fitting with red paint over a coat of ready mixed primer bothof approved quality and shade including cutting holes and chases in brickor RCC walls/Slabs and making good the same etc complete in all respect as required ("C" Class) Make: Jindal Hissar, TATA,Sail
297150 mm dia
298100 mm dia
29980 mm dia
300Providingand applyingone coat of 4 mm thickPYPKOTE OR COATEK anti rust pipe protection inclduing approved primer of 2 coats as per manufacturers specifications and lap of 25 mm to make and impermeable layer on pipes in trenches or on structural /masonary members complete including surface preparation.
301150 mm dia
302Supplying Installing Testing and Commissioning of Butterfly valves of PN 1.6 rating of following sizes with nitlrile Bronze/G.M. seat duly ISI marked and stainless steel stem with lever /gear operation and cast iron body in powder coated finish for fire fighting application complete in al respect confirming to IS 13095 as required. Make: Kirloskar Audco, Advance, Honeywell, Zoloto
303150 mm dia
304100 mm dia
30580 mm dia
306Supplying and Fixing Single Headed Internal Hydrant Valve oblique pattern with instantaneousStainless steel coupling of 63 mm dia with cast iron wheel ISImarked conforming to IS 5290 (TypeA) with 80 mm dia flanged inlet, with ABS cap andchain complete with all accessories etc. as required.
307Ground , First, 2nd , 3rd Floor.
308ProvidingFixing and Testingof 63mm dia , 15 mtr long RRL hose pipe with 63mm dia male and female Gun metal coupling duly binded with stainless steel (SS) wire, Rivets etc. confirming to IS 636 (Type-A)as required.
309Supplying and Fixing Stainless Steel branch pipe with 20mm dia nozzle conformingto IS 903. suitable for installation connections to hose coupling etc. as required.
310Supplyingand Fixing First Aid Hose Reel, wall mounting swinging type complete with drum and bracket of MS Construction, spray painted in Post office Red, Confirming to IS 884/1995 with upto date amendments, complete with ;the followingas required (Make :padmini/Exflame/FGE)
31130 Meter long 20mm dia water hose thermoplastic(Textile reinforced) Type -2 as per IS 12585
31225mm dia ball valve & nozzle.
313Drum and brackets for fixing the equipments on wall.
314Connection from riser with stop valve (Gunmetal) & M.S.Pipe.
315Supplying Installing Testing Commissioning of weather proof M.S. cabinet size 600mmx600mm x450mm deep fabricated from 1.6mm thick M.S. Sheets and M.S. angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following :-
316SS Singleheaded Hydrant Valve- 1 No.
317Fire Hoses 63mm 15 M long with accessories -1 Nos.
318Short Branch -1 No.
319Providing Fixing Testing and commissioning of pressure vessel (250 mm dia & 1500 mm height ) for pressurization of fire system complete with pressure switches with isolation valves, pressure gauge with isolation valve, valves at outlet drain to operate as per operating sequences including 25mm dia drain valve, air release valve with stop cock on the top Duly painted from inside and outside complete as required.
320Supplying Installing Testing Commissioning of ISI Marked(IS:15638)protablefire extinguisher ABC (Gas pressure) type capcity 4 Kg with gun metal cap and nozzle and complete in all respects including initial fill and wallsuspension bracketsas requriedas per specifications.
321Supplying and Instlling of 3 Nos. set of fire buckets of 24 guage galvanized steel sheet, standard 9 litr capacity and of round bottom shape painted white inside and red outsideand blck on thebottom, inscribed with letters "Fire" in black and gold.
322Supplying, Laying, Testing and Commissioning of Kirloskar make pump in back pull out design having 50mm suction, 32 mm delivery, CI casing, bronze impeller and C-40 shaft with gland packed arrangement coupled on common baseplate to Kirloskar/ABB (at our option) make 10 KW /7.5 HP, 2900 RPM TEFC sq. cage induction motor suitable for 3 phase, 415V, 50 Hz AC supply through suitable flexible coupling. The pumpset is suitable for following duties: Total head : 35m Flow : 27 m^3/hr (450 lpm)
323DUAL PLATE NON RETURN VALVE
324Providing, fixing, testing and commissioning of DUAL PLATE NON RETURN VALVE (all valves shall be ISI marked and shall be one approved makes) of following sizes confirming to IS 5312 complete withrubber gasket , GI bolts, nuts and washers etc. as required. Make: Audco/ Advance/ Kirloskar/ Castle/ Honeywell
325100 mm dia
326Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, dischargenozzle, suspension bracket, confirming to IS: 15683 finished externally with redenamelpaint andfixed towall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
327Supplying, laying, testing and commissioning of MS made cubicle panel made out of 1.6mm CRCA sheet powder coated with siemens color. The panel is design for wall mounting type with cable incoming and out goings from bottom. All the switchgear are from L&T /Schneider/Eaton Make MCB TP 32A, Contractor MNX-12A., Over load relay 4.5-7 5A, ON/OOF indication, STOP/START Push Button, Auto/Manual Switch, Terminal STRIP, MBC 1 POLE 6 Amp, Aux. Cont., SDS Timer, SPPR, Enclosure & accessories fabrication in 1.6mm. CRCA Sheet powder coating in Siemens Gray Shede, 75X40MM. Channel Base Frame, Cable Entry will be Top & Bottom Suitable for Cable Lock, Rubber Gasket, hardware etc. Wiring & Accessories Power & Control wiring will be (ISI 1100V) flamo smoke FRLS PVC Singte Core Copper Wire Copper Lugs, PVC Steeve, Ferruels Numbers, Hardware & Lbour etc. including Starter suitable for 7.5 Hp mortar.
328Supplying and laying of XLPE insulated, PVC sheathed aluminium conductor 1.1 KV grade armoured I.S.I marked cable of makes given in the list of approved makes of following sizes laid on surface including cable terminations, galvanised cable tray of thickness as specified, brass compression Glands, aluminium lugs suitably clamped as specified and as required.
3294 Core x 10 sq. mm.
330Supplying & fixing of SELF ILLUMINATION TYPE EXIT SIGN, 400X150MM suitable size as required.
331Providing and fixing dial type pressure gauge with isolation cock and copper pipeat hydrant station. Make:FIEBIG/H GURU
332Providing and fixing of cover for all terrace pumps made up of corrugated PVC fibre sheet with 25 x 25 x 4 MS angel frame with openable door having lockable facility and painting the MS angel with 1 coat of red oxide primer and 2 coats of black enamel paint complete in all respects as shown in the drawings.
333Providing and fixing dual type pressure switch suitable for 1-20 Kg/cm2 including electrical connections setting of Cut-In and cut-Off pressure complete in all respects.
334ELECTRICAL INSTALLATION
335DSR Item No. 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5Sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5Sq mm. FRLS PVC insulated copper conductor single core cable etc as required.
336Group-C
337DSR Item No.1.4 Wiring for twin control light point with 1.5Sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the pointwith 1.5Sq mm. FRLS PVC insulated copper conductor single core cable etc as required.
338DSR item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3393 x 1.5 Sq. mm
3403 x 2.5 Sq.mm
3413 x 4 Sq. mm
342DSR item No.1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
34320 mm
34425 mm
345DSR Item No. 1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
34625 mm (For Internet and Telephone & CCTV)
347DSR Item No. 1.7 Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed and steel conduit as required.
3484 X 16 sq. mm + 2 X 6 sq. mm earth wire
3494 X 10 sq. mm + 2 X 6 sq. mm earth wire
350DSR item No.1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
351200 mm X 250 mm X 60 mm deep
352DSR item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
3531 or 2 Module (75mmX75mm)
354DSR Item No.1.31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
355DSR Item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/ 16A modular switch, connections etc as reqd.
356DSR Item No. 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
357DSR Item No. 10.18 (Civil) Providing and fixing circular / hexagonal cast iron or MS sheet box for ceiling fan clamp of internal dia 140mm, 73mm height top lid of 1.5mm thick MS Sheet with its top surface hacked for proper bonding, top lid shall be screwed in to the cast iron / MS Sheet box by means of 3.3 mm dia round headed screws one lock at the corners. Clamp shall be made of 12 mm dia MS bar bent to shape as per standard drawing.
358DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
359Telephone socket outlet
360DSR item No.2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator).
3614 way (4 + 12), Double door
3626 way (4 + 18), Double door
3638 way (4 + 24) Double door
364DSR item No.2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
365Single pole
366Triple pole and neutral
367DSR Item No. 2.18 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
368DSR Item No. 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
369DSR item No.5.11Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
370DSR item No.5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
371DSR item No.5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
372DSR item No.9.1Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.
3734 X 10 sq. mm (25mm)
3743½ X 50 sq. mm (35mm)
3753½ X 120 sq. mm (45mm)
3763½ X 400 sq. mm (82mm)
377DSR item No.4.1 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
378375 mm width X 62.5 mm depth X 2mm thickness
379DSR Item No. 1.33 Supplying and fixing 3 pin, 5 Amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required.
380DSR item No.14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
381200 mm dia (OD-200 mm & ID-175 mm nominal)
382S/E of AC ceiling fans 230Volts rating with copper winding but without regulator complete with Aluminium blades, plastic canopies 2 Nos. double ball bearing, MS hanging rods (As per site requirement), condenser, reels, clamps etc. The body of fan and blades should be white in colour. The job includes the cost of making necessary connections from the adjacent light point with 1.5mm2 single core copper conductor cable and 3mm thick white B.L. sheet cover for fan box of suitable size. The sample of fans shall be got approved from the Engineer-in-charge of work before installation at site.The job also includes the cost of carriage, erection, testing, commissioning of fan, all labour and petty material required to complete the job to the entire satisfaction of the Engineer-In-Charge.
383Size 56” 1400mm sweep ceiling fan of Havells make Velocity / Orient make New Breeze / Crompton make High Speed / Usha make Striker/ Bajaj make Spedster only.
384Supply & erection of Exhaust Fan of 230 Volts rating (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of carriage charges, making connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer in Charge.
385Size 15 inches (380mm) Sweep, 900 RPM, Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Crompton (EXHD380-6-1) / Bajaj (Supreme Dlx HD 380) / Orient 15” H.D. EX Fan / Almonard / Usha (Turbo Heavy Duty) make only.
386Supply and laying of PVC insulated PVC sheathed Aluminium conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/ HUME / DWC pipe. The job include the cost of making connections with suitable size of Aluminium Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge.
387Size 400 Sq. mm. 3.5 Core PVC Aluminium conductor armoured Cable
388Supply and laying of PVC insulated PVC sheathed Aluminium conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing cable tray/ trench. The job include the cost of making connections with suitable size of Aluminium Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge.
389Size 400 Sq. mm. 3.5 Core PVC Aluminium conductor armoured Cable
390Supply and laying of PVC insulated PVC sheathed Aluminium conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid direct on surface with the help of suitable size MS clamp.The job include the cost of making connections with suitable size of Aluminium Lugs / thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge.
391Size 10 Sq. mm. 4 Core PVC Aluminium conductor armoured Cable.
392Size 50 Sq. mm. 3.5 Core PVC Aluminium conductor armoured Cable.
393Size 120 Sq. mm. 3.5 Core PVC Aluminium conductor armoured Cable.
394Providing and fixing following rating MCCB 4 pole 415 Volt without MS enclosure (Thermal magnetic/ microprocessor release) for over load and short circuit protection, Breaking capacity 36KA (Ics=100% Icu). The overload & short circuit release shall be of adjustable type. The MCCB is to be installed in existing MS enclosure / distribution boards / angle iron board/ LT Cubical panel as required including drilling holes in angle iron board, making connections etc. The job includes the cost of copper spreaders terminal links and direct/ extended rotary handle as required at site.
395100 Amp 4 Pole MCCB (Thermal Magnetic release). The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.
396160 Amp 4 Pole MCCB (Thermal Magnetic release). The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.
397250 Amp 4 Pole MCCB (Microprocessor release). The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.
398Providing and fixing following rating MCCB 4 pole 415 Volt without MS enclosure(microprocessor release) for over load, short circuit, instantaneous, inbuilt ground fault protection (LSIG), Breaking capacity 50 KA (Ics=100% Icu). The overload & short circuit release shall be of adjustable type. The MCCB is to be installed in existing MS enclosure / distribution boards / angle iron board/ LT Cubical panel as required including drilling holes in angle iron board, making connections etc. The job includes the cost of copper spreaders terminal links and direct/ extended rotary handle as required at site.
399630 Amp 4 Pole MCCB (Microprocessor release). The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.
400Supplying and fixing following rating 240/415 V, 10 kA, "C" curve, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge.
401MCB 63 Amp 4 pole
402Supply and fixing of 12 modules (200 mm x 150 mm) G.I box in surface/recess as required with modular plate and cover in front on surface, including providing and fixing 4 Nos. 5/6 Amps modular switch and 4 Nos. 3 pin 5/6 Amps modular socket outlet. The job includes the cost of making interconnections with suitable copper wire and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site.
403Supply & fixing ofRJ 45 SOCKET with Shutter for CAT 6 LAN cable (one module) including making connection as required completing thejob to the entire satisfaction of EIC.
404Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN aluminium bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common aluminium earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of\ accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The depth of panel should be upto 600mm deep. The LT panel should have provision of following switchgear and accessories:-
405INCOMING
406Space for 1 No. 630 Amps., 50KA, 4 Pole, MCCB
407Space for one number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 630/5 A class 1.0 accuracy and 15 VA burden.
408Space for one set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required
409BUS BAR:
410TPN aluminium bus bars (having 100% neutral) of minimum of 600 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set.
411OUTGOING:
412Space for 3 Nos. 100Amp. 415 V. 4 pole 36KA MCCB
413Space for 1 No. 160 Amp. 415 V. 4 pole 36KA MCCB
414Space for 1 No. 250 Amp. 415 V. 4 pole 36KA MCCB
415Space for 18 Nos. MCB SP and1 No. 63Amp. MCB TPN = 2 Nos.
416Space for 2 Nos. 63 Amp 4 pole MCB
417Space for 2 Nos. 32 Amp MCB TPN
418LT Panel approx. size 2375 mm x 1600 mm
419Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN aluminium bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common aluminium earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The depth of panel should be upto 600mm deep. The LT panel should have provision of following switchgear and accessories:-
420INCOMING
421Space for 1 No. 160 Amps., 36KA, 4 Pole, MCCB.
422Space for one number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 630/5 A class 1.0 accuracy and 15 VA burden.
423Space for one set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required
424BUS BAR:
425TPN aluminium bus bars (having 100% neutral) of minimum of 300 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set.
426OUTGOING:
427Space for 1 No. 100 Amps., 36KA, 4 Pole, MCCB.
428Space for 18 Nos. MCB SP and1 No. 63Amp. MCB TPN = 2 Nos.
429Space for 2 Nos. 63 Amp 4 pole MCB
430LT Panel approx. size 1425 mm x 1300 mm
431Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN aluminium bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common aluminium earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The depth of panel should be upto 600mm deep. The LT panel should have provision of following switchgear and accessories:-
432INCOMING
433Space for 1 No. 100 Amps., 36KA, 4 Pole, MCCB.
434Space for one number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 630/5 A class 1.0 accuracy and 15 VA burden.
435Space for one set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required
436BUS BAR:
437TPN aluminium bus bars (having 100% neutral) of minimum of 300 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set.
438OUTGOING:
439Space for 18 Nos. MCB SP and1 No. 63Amp. MCB TPN = 2 Nos.
440Space for 1 No. 63 Amp 4 pole MCB
441LT Panel approx. size 1425 mm x 1300 mm = 2 Nos
442Supply and erection of 16 GMS sheet frame of suitable size for erection of 12”/15”/18” sweep exhaust fan. The holder should be suitable for 12”/15”/18” sweep exhaust fan shall be cut from the centre of the sheet and bedding ¼” round collar with round cut and duly fixed with existing ventilator frame with suitable arrangement after removing the existing glass. The exhaust fan frame shall be painted on both side with superior quality paint after one coat of primer. The job includes the cost of M.S. strips of 1”x1/4” and other petty material required to complete the job to the entire satisfaction of E.I.C.
443S/I/T/C of 1x4’x18/20Watt. LED box type fittings made of CRCA Sheet with LED tube rods. The fittings should be installed on existing surface. The LED tube rod should be of Philips/ Wipro/ Havells/ Bajaj/ Crompton/ Jaquar/ Twinkle make of polycarbonate material only. The batten for hosing the tube rod should be of Philips/ Havells/Wipro/ Bajaj/ Crompton/ Jaquar/ Twinkle make only. The job includes carriage, erection, making connections testing and commissioning of the fittings. Specification of LED fittings:
444Wattage of LED fittings (As per following parameter)
445Total lumens of the LED fittings (Minimum 1800 lumen)
446Diffuser(Extrusion Aluminium heat sink with Polycarbonatediffuser.)
447Operating voltage (140 V to 270 V, AC supply or better.)
448Input frequency (50 Hz + 1 Hz)
449Power factor (Minimum 0.95)
450Luminaire efficacy (>100 lm/w)
451Color rendering index (CRI shall be greater than 80)
452Working/ operating temperature (00 to + 450c or better)
453Color temperature (60000K to 65000K)
454Electronic Driver
455Drive current (LED) (As per OEM.)
456Operating voltage (140 V to 270 V AC supply or better)
457Type of driver (Constant current output driver)
458THD (Less than 10%)
459Surge Protection (2.5 KV minimum)
460Efficiency Driver (>85%)
461Protection (Shall have under voltage and over voltage protection.)
462Guarranty of LED fittings including LED driver(2 years against manufacturing defect.)
463Fixture (Should comply with LM 79 test from NABL/UL lab.)
464LED Type/ Make/ Model (Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 30,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.)
465Life of LED (30000 burning hours at 70% lumen maintenance )
466S/I/T/C of 18W./20W. LED Square type surface mounted fitting with integral/ non integral driver to be installed on existing surface with the help of rawl plug & screws etc. The fitting should be Philips / Wipro / Bajaj / Trilux / Jaquar / Panasonic/ Twinkle make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point, other petty material and labour etc. as required to complete the job to the entire satisfaction of Engineer In Charge. Specification of LED fittings:
467Wattage of LED fittings (As per following parameters)
468Total lumens of the LED fittings (Minimum 1800 lumen)
469Body of fittings (CRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.)
470Operating voltage (140 V to 270 V, AC supply or better.)
471Input frequency (50 Hz + 1 Hz)
472Power factor (Minimum 0.95)
473Luminaire efficacy (>100 lm/w)
474Color rendering index (CRI shall be 80 (minimum))
475Working/ operating temperature (00 to + 450c or better)
476Color temperature (60000K to 65000K)
477Electronic Driver
478Drive current (LED) (As per OEM.)
479Operating voltage (140 V to 270 V AC supply or better)
480Type of driver (Constant current output driver)
481THD (Less than 10%)
482Surge Protection (2.5KV minimum)
483Efficiency Driver (>85%)
484Protection (Shall have under voltage and over voltage protection.)
485Guarantee of LED fittings including LED driver (2 years against manufacturing defect.)
486Fixture(Should comply with LM 79 test from NANL/UL lab.)
487LED Type/ Make/ Model(Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance complying with LM 80 test report from the manufacturer.)
488Life of LED(50000 burning hours at 70% lumen maintenance)
489S/E of one number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 630/5A class 1.0 accuracy and 15 VA burden along with S/E of one set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice as required
490S/I/T/C of 2’x2’ LED Square type surface mounted fitting with integral/ non integral driver to be installed on existing surface with the help of rawl plug & screws etc. The fitting should be Philips / Wipro / Bajaj / Trilux / Havells / Crompton/ Jaquar/ Twinkle make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point, other petty material and labour etc. as required to complete the job to the entire satisfaction of Engineer In Charge. Specification of LED fittings:
491Wattage of LED fittings (As per following parameters)
492Total lumens of the LED fittings (Minimum 3300 lumen)
493Body of fittings (CRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.)
494Operating voltage (140 V to 270 V, AC supply or better.)
495Input frequency (50 Hz + 1 Hz)
496Power factor (Minimum 0.95)
497Luminaire efficacy (>100 lm/w)
498Color rendering index (CRI shall be 80 (minimum)
499Working/ operating temperature (00 to + 450c or better)
500Color temperature (60000K to 65000K)
501Electronic Driver ()
502Drive current (LED) (As per OEM.)
503Operating voltage (140 V to 270 V AC supply or better)
504Type of driver (Constant current output driver)
505THD (Less than 10%)
506Surge Protection (2.5KV minimum)
507Efficiency Driver (>85%)
508Protection (Shall have under voltage and over voltage protection.)
509Guarantee of LED fittings including LED driver (2 years against manufacturing defect.)
510Fixture (Should comply with LM 79 test from NANL/UL lab.)
511LED Type/ Make/ Model (Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance complying with LM 80 test report from the manufacturer.)
512Life of LED (50000 burning hours at 70% lumen maintenance )
513S/I/T/C of 2’x2’ LED Square type recessed mounted fitting with integral/ non integral driver to be installed on existing false ceiling with the help of steel chain / fastener, screws etc. The fitting should be Philips / Wipro / Bajaj / Trilux / Havells / Crompton/ Jaquar/ Twinkle/ Panasonic make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point, other petty material and labour etc. as required to complete the job to the entire satisfaction of Engineer In Charge. Specification of LED fittings:
514Wattage of LED fittings (As per following parameters)
515Total lumens of the LED fittings (Minimum 3960 lumen )
516Body of fittings (CRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.)
517Operating voltage (140 V to 270 V, AC supply or better.)
518Input frequency (50 Hz + 1 Hz)
519Power factor (Minimum 0.95)
520Luminaire efficacy (>120 lm/w)
521Color rendering index (CRI shall be 80 (minimum))
522Working/ operating temperature(00 to + 450c or better)
523Color temperature (60000K to 65000K)
524Electronic Driver ()
525Drive current (LED) (As per OEM.)
526Operating voltage (140 V to 270 V AC supply or better)
527Type of driver (Constant current output driver)
528THD (Less than 10%)
529Surge Protection (2.5KV minimum)
530Efficiency Driver (>85%)
531Protection (Shall have under voltage and over voltage protection.)
532Guarantee of LED fittings including LED driver (2 years against manufacturing defect.)
533Fixture (Should comply with LM 79 test from NANL/UL lab.)
534LED Type/ Make/ Model (Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance complying with LM 80 test report from the manufacturer.)
535Life of LED (50000 burning hours at 70% lumen maintenance)
536S/E ofLED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The LED Bulk Head fitting should be of Philips / Trilux / Lighting Technologies / Jaquar / Wipro / Bajaj /Crompton / Havells /Panasonic make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD<15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.
537Supply & erection of Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 Nos. of pull cord switches, one for oscillation and one for speed regulation. The fan should be of Havells make Swing / Crompton greaves make WM Wind FIO (HiSpeed) / Orient make 400 mm (16") Wall-45/ Bajaj make media BW07 400 mm wall only. The cost includes the connection with adjacent light points and installed on wall with suitable size rag bolts, nuts and other material required to complete the job to the entire satisfaction of Engineer-in-Charge.
538S/E of High Power LED Flood light luminaries of Philips/ Lighting Technologies/ Wipro / Bajaj /Crompton /Panasonic / Surya make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm. copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer in Charge.Specification of LED fittings:
539Wattage of LED fittings (As per following parameter)
540Total lumens of the LED fittings (Minimum 13200 lumen)
541Ingress protection level of fittings (IP 65 or better)
542Body of fittings(Pressure dia cast aluminium body with Extruded Aluminium heat sink)
543Operating voltage (140 V to 270 V, AC supply or better.)
544Input frequency (50 Hz + 1 Hz )
545Power factor (Minimum 0.95)
546Luminaire efficacy (Minimum 110 lm/w)
547Color rendering index (CRI shall 70 (minimum))
548Working/ operating temperature (00 to + 450c or better)
549Color temperature (55000 K to 65000K)
550Electronic Driver
551Drive current (LED) (Constant current less than 750 MA)
552Operating voltage (140 V to 270 V AC supply or better)
553Type of driver (Constant current output driver)
554THD (Less than 10%)
555Surge Protection (10 KV minimum)
556Efficiency Driver (>85%)
557Protection (Shall have under voltage and over voltage protection.)
558Guarantee of LED fittings including LED driver (2 years against manufacturing defect.)
559Fixture (Should comply with LM 79 test from NABL lab.)
560LED Type/ Make/ Model (Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the original manufacturer.)
561Life of LED (50000 burning hours at 70% lumen maintenance)
562S/Eof Thermo Plastic cable Jn. Box IP 55/65 “Weather Proof” for outdoor installation having dimensions 167x125x82 mm deep approximate with 4 nos. thermal block suitable for incoming and outgoing cables as required at site. The terminal block should be of Hansel make K-9105 with terminal link/ Clipsal or its equivalent make Wago/ Elmex/ Siemens only and cable junction box should be of Hansel / Legrand / Clipsal make only. The job includes all labour and petty material to required complete the job to the entire satisfaction of the Engineer in Charge of work.
563S/E of M.S. bracket (‘L’ shape) made from 40mmx40mmx 5mm thick angle iron to be installed on existing parapet / wall with the help of suitable size of nuts & bolts etc. for erection of metal halide flood light fitting. The job includes cost of painting of bracket with superior quality of paint and other all petty material etc. as required to complete the job.
564S/E of enclosure for MCCB630 Amp 3 Pole / 4 pole made out of 16 Gauge M.S. sheet. The enclosure is to be painted after one coat of primer including its erection in existing angle iron board with nut bolts/ screws etc. to complete the job to the entire satisfaction of Engineer In Charge.
565PASSENGER LIFT:
566Supply, erection, testing and Commissioning of 10 passenger lifts, 1.0 MPS (minimum), 4 Stop & 4 Openings, 4 Floor 10 Mtr. Travel Approx. as per technical specification of technical bid. The rates includes the cost of minor civil work and steal item required for installation for lifts in all respect to the entire satisfaction of Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail