Rural Development Department has published Tender For Jal Jeevan Mission Water Supply Projectfor Pimpri Nirmal Tal Rahata Dist. Ahmednagar. Submission Date for this Tender is 01-09-2022. Water Supply Project Tenders in ahmednagar Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 24-Aug-2022 | DATE 02 | Date | 29-08-2022 |
2 | 29-Aug-2022 | DATE 03 | Date | 01-09-2022 |
Sl. No. | Item Description |
1 | Raw Water Gravity Main Item No. 1Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cementolvent). 280 MM PVC 6KG/CM^2 |
2 | Item No. 2Providing PVC Specialssuitable for pipe diameter including all taxes etc complete 5 % Cost of Pipe |
3 | Item No. 3Providing and supplying ISI mark Sluice valve including all taxes, railway freight, inspection charges unloading from railway wagon, loading into truck, transportation unto site, unloading, stacking etc.complete.Sluice Valve P,N 1.0 Without Bypass300 MM |
4 | Item No. 4Providing and supplying Kinetic Double Orifice type AirValves confirming to IS 14845 as per N4JP"s standard specifications having small orifiee elastic ballresting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring,with builGin Kinetic features, isolating sluice valve mounted in horizontal position and operated by wheel gearing, inlet face and ctrilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.50 MM |
5 | Item No. 5Excavation for Foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum,including removing the excavated material up to a distance of 50 meters and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
6 | Item No. 6Excavation for foundation / pipe trenches by all means in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer- In-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259) |
7 | Item No. 7Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd- A-3/259) |
8 | Item No. 8Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers |
9 | Item No. 9Lowering, laying and jointing with P.V.C. pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material, except cement solvent, rubber ring, as per IS code, etc. complete (with cement solvent joint / ring fit joint).280 MM |
10 | Item No.10Lowering, laying and jointing in position following CID/F Reflux valves & Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.Sluice Valve P,N 1.0 Without Bypass300 MM |
11 | Item No.11Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) 200 MM TO 400 MM |
12 | Item No. 12Providing and laying in situ following grades of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding excluding dewatering, form work, compacting and curing, finishing etc. complete. c) 1:2:4 (M-150) grade for encasing |
13 | Item No. 13 Providing & casting in situ C.C. of trap metal for RCC work as per detaileddrawing & designexcluding dewatering, centering from work compaction, finishing the formed surfaces with C.M.(1:1 1/2:3) of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if special finish is to be provided & curing etc. complete.RCC M- 200 for Thrust Blocks |
14 | Item No. 14 Providing & fixing in position steel bar "reinforcement of various dia. for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases, newels chajjas, lintels, pardies copings fins, arches, etc. as per detailed "design & drawing & schedules, excluding cutting, bending, hooking the bars, binding with wire track "welding & supporting as required, etc. complete |
15 | Item No. 15 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5proportion 12 mm thick cement plaster in cm 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or cm thick slab etc. complete as directed by Engineer-in-charge.Size 1.2 X 1.2 X 1.2 M |
16 | Item No. 16 Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing endcap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.280 MM |
17 | Item No. 17 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts excluding consolidation, surcharging, etc. complete |
18 | Earthen Balancing Tank Item No-1 Cleaning cutting thorny shrubs bushes, grass as directed with 15m lead and lift up to 1.5m. |
19 | Item No 2 Excavation in all kinds of soil including boulders upto 0.6 m diameter (0.113 cum) for canal, seating of embankment, filter drains / catch water drains etc., and placing the excavated stuff neatly in dump area or for formation of service road / embankment as directed including cost of all materials, machinery, labour, dressing bed and sides to required level and profile etc., complete with lead upto 1 km and lift upto 6 m.A) Lift 0 To 6.00 m |
20 | Item No-3 Excavation in hard murum including boulders upto 0.6 m diameter (0.113 cum)for canal, seating of embankment, filter drain / catch water drains etc., and placing the excavated material neatly in dump area or for formation of service road as directed including cost of all materials, machinery, labour, dressing bed and sides to required level and profile etc., complete with lead upto 1 km and 6m lift. A) Lift 0 To 6.00 m |
21 | Item No 4 Excavation in Soft rock including boulders upto 0.6 m diameter (0.113 cum)for canal, seating of embankment, filter drain / catch water drains etc., and placing the excavated material neatly in dump area or for formation of service road as directed including cost of all materials, machinery, labour, dressing bed and sides to required level and profile etc., complete with lead upto 1 km and 6m lift. A) Lift 0 To 6.00 m |
22 | Item No 5 Excavation in hard rock of all toughness by breaker including boulders above 0.6 m dia.(0.113Cum) minimising damage to side slopes of excavation and placing the excavated rock neatly in approved dump area including cost of all materials, machinery, labour,levelling bed etc., complete with lead upto 1 km and all lifts as directed .A) Lift 0 To 6.00 m |
23 | Item No 6 Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery) |
24 | Item No 7 Disposing of surplus excavated material including loading, unloading, transporting, spreading or stacking as directed by the Engineer in charge upto 5 km |
25 | Item No 8 Providing cut off trench filling using selected impervious soil directly available from material of excavation including cost of all materials, machinery, labour, all other operations such as collection of soil, spreading soil in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc., complete with lead upto1 km for watering and lift upto 6m. |
26 | Item No 9 Providing cut off trench filling using selected impervious soil from approved borrow areas including cost of all materials, machinery, labour, all other operations such as collection of soil, spreading soil in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc. complete with lead upto1 km & lift upto 6 m. |
27 | Item No 10 Providing casing embankment using selected pervious material available directly from excavation in layers including cost of all materials, machinery, labour, all other operations such as collection of material, spreading material in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc., complete with lead upto1 km for watering and lift upto 6 m. |
28 | Item No 11 Providing casing embankment using selected pervious material from approved borrow areas in layers of including cost of all materials, machinery, labour, all other operations such as collection of soil, spreading soil in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc., complete with lead upto1 km & lift upto 6 m. |
29 | Item No 12 Providing hearting embankment using selected impervious material available directly from excavation in layers including cost of all materials, machinery, labour, all other operations such as collection of material, spreading soil in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc., complete with lead upto1 km for watering and lift upto 6 m. |
30 | Item No 13Providing hearting embankment using selected impervious soil from approved borrow areas in layers including cost of all materials, machinery,labour, all other operations such as collection of soil, spreading soil in layer of specified thickness, sorting out, breaking clods, levelling, sectioning edges / sides, watering, compacting each layer to density control of not less than 95 percent or as stipulated using vibratory compactor etc., complete with lead upto1 km & lift upto 6 m |
31 | Item No 14 Providing and filling in sand boxing in trenches with sand of approved quality including watering and compaction as directed etc complete. |
32 | Item No 15 Providing and Supplying & Laying HDPE geomembrane sheet 0.5 mm thk. 100% acid, alkali proof 100% rain forced sealing quality every joints eleronically welded as per relavent is specification and placing in proper position prepared bed on foundation/ embankment with welding the joints of sheet using but wedge and extension welding techniques according to the liner manufactures specification in anhance temparature of 5 to 450 C inclding all taxes and labour for joining and placing etc complte(500 mm micron) |
33 | Item No 16 Providing and constructing 300 mm thick dry rubble stone pitching with pin headers at 2 per sqm using stones and stone chips from approved source including cost of all materials, labour, hand packing / wedging stone chips, finishing etc.,complete with lead upto 50 m and all lifts. |
34 | Item No 17 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for PCC work below foundation and footing including normal dewatering,plywood form work, compaction, finishing and curing, etc, complete cc M 150. |
35 | Item No 18 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, ,plywood form work,bully/steel prop ups compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC M 20 FOR BEAM |
36 | Item No 19 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, ,plywood form work,bully/steel prop ups compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC M-200 for slab Vertical wall |
37 | Item No 20 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation,slabs, beams, columns, canopies, staircases. newels,chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting,bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire |
38 | Item No 21 G.I. chain link of size 50 x 50 mm 8 guage thick and fixed 75mm above Ground level on vertical M.S Angle of 40 x 40 x 6 mm size including excavating pits for foundation and embeddedin C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75M.c/c with iron bar 16 mm dia as hold fast including weldinglink with angle frame at 30 cm c/c with nuts and bolts andhorizontal M.S. Angles at top and bottom of 25 x 25 x 5 mmsize and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontalincluding cross support of 40 x 40 x 6 mm Angles both sides atevery corner or bends embedded in concrete blocks of 1:4:8 ofsize 450 x 450 x 670 mm including 3 coats of oil painting etc. |
39 | Item No 22 Providing and fixing M.S. gate 2.5 M wide for compound with 40 mm dia M.S.black pipe medium class, approved grill work, RCC M - 150 side pillars of 25 cm x 40 cm x 2.5 M height, its foundation, finishing, painting etc. complete. |
40 | Item No 23 Providing and fixing water level indicator upto 5 M height including M.S. enamelled gauge plate 300 mm wide 3 mm thick, P.V.C. float, providing and fixing required accessories such as pointer, pulleys, nylon thread including cost of all material, labour, etc. complete |
41 | Item No 24 Providing and fixing P.C.C. guard stone/indicator stones of standard size and shape (200 x 200 x 600 mm) including fixing in ground and white washing etc. complete. Spec.No. : As directed by Engineer in charge. |
42 | Item No 25Providing lowering laying jointing the site of work 300 mm. dia. R.C.C. P2 class coller / rubber rings all taxes (central & local) transport to site of works hydraulic testing etc. complete as directed .300 mm dia RCC P-2 |
43 | Item No 26 Design Charges For Balancing Tank from MERI |
44 | Item No 25Taking Trial Bore (Core Bore Sampling) by Calyxe machine with TCT/NX bits together undisturbed strata samples for investigation in all types of strata soft soil, murum, hard murum with boulders, soft rock hard rock & quartizite etc. The item includes all Hire & running cost of Callyx Machine conveying all materials to site of work excluding conveyance of callyx, machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden Core Box, Samples to be taken at 1.0 m interval and conveying to the place as directed by Engineer-in-charge, The diameter of bore in overburden shall be 100 mm and of NX size (50mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburdern only and shall be 1.0 m above GL with cap over it.In Overburden (Soft soil, ) |
45 | In HBM |
46 | In Soft rock |
47 | Item No 28 Analysis & preparation of detailed report pertaining to Geotechnical & Geological Investigation of the Trial Bore samples taken& submission of the same to the department with due recommendation in view of construction of water retaining structure such a50 % of Item No 27 |
48 | Item No 29 Royalty chargesNote :- Reimburcement of royalty charges actually paid by contractor to Revenue Department for quantity of material (Sand,Metal,Murum, Stone, Soil )broughtfrom outside at site for construction of balancing tank |
49 | Raw Water Sump& P House in Balancing TankR W Sump Item No. 1 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd- A-2/259) |
50 | Item No. 2 Providing and casting in situ CC of trap/granite/ quartzite/ gneiss metal of approved quality for CC M-15 work as per detailed drawings and design or as directed by Engineer-in-charge including normal dewatering, centering, formwork, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish to be provided and curing, etc complete.PCC M-15 |
51 | Item No. 3 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work infoundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, plywood form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCC M-200 |
52 | Item No. 4 Providing and casting in situ CC of trap/granite/ quartzite/ gneiss metal of approved quality for RCC M-20 work as per detailed drawings and design or as directed by Engineer-in-charge including normal dewatering, centering, formwork, compaction, finishing the formed surface with CM 1:3 ofufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish to be provided and curing, etc complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted) excluding M.S. or Tor Steel.For RCC Beams M - 200 |
53 | For VERTICAL WALL RCC M - 200 |
54 | For Slab RCC M - 200 |
55 | Item No. 5 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire) |
56 | R W Pump House Item No. 1 Providing & casting in situ C.C.for RCC work as per detaileddrawing & design orasdirectedby Engineer-in-charge including dewatering, centering from work compaction, finishing the formed surfacescuring etc. complete. (By weigh batching and mix M200. Only use of L&T, A.C.C., Ambuja, Birla gold Manikgad, Rajashree, etc. cement is permitted. Excluding M.S. or Tor reinforcement.For R.C.C. (M-300) grade Column |
57 | Item No. 2 Providing & casting in situ C.C.for RCC work as per detaileddrawing & design orasdirectedby Engineer-in-charge including dewatering, centering from work compaction, finishing the formed surfacescuring etc. complete. (By weigh batching and mix M200. Only use of L&T, A.C.C., Ambuja, Birla gold Manikgad, Rajashree, etc. cement is permitted. Excluding M.S. or Tor reinforcement.For R.C.C. (M-300) grade Beams |
58 | Item No. 3 Providing & casting in situ C.C.for RCC work as per detaileddrawing & design orasdirectedby Engineer-in-charge including dewatering, centering from work compaction, finishing the formed surfacescuring etc. complete. (By weigh batching and mix M200. Only use of L&T, A.C.C., Ambuja, Birla gold Manikgad, Rajashree, etc. cement is permitted. Excluding M.S. or Tor reinforcement.For R.C.C. (M-300) grade Slabs |
59 | Item No. 4 Providing & fixing in position steel bar "reinforcement of various dia. for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases, newels chajjas, lintels, pardies copings fins, arches, etc. as per detailed "design & drawing & schedules, including cutting, bending, hooking the bars, binding with wire track "welding & supporting as required, etc. complete |
60 | Item No. 5 Providing and fixing M.S. chaquerred plate flooring of following thickness supported on M.S.angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plate to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge. |
61 | Item No. 6 Providing Bricks masonry in cement mortar 1:6 using Second Class Burnt Bricks bricks in superstructure including striking joints, raking out joints, watering and scaffolding complete. |
62 | Item No. 7 Providing and fixing steel windowsCRC sheet of various sizes as per detailed drawings with welded square bars 12 mm at 10 cm centre to centre without hot dip zinc coating without/with ventilator including fabrication, glazing with non-acetinic/ plain/ obscured glass panes of approved type and quality, all fixtures and fastenings without teak wood boxing, and architraves and finishing with one coat of primer complete. |
63 | Item No.8 Providing & fixing rolling steel shutters fabricated from 18 gaug steel laths with side guides, bottom rail , brackets, door suspension, shaft, housing box arrengement and painting with three coats of approved shad oilpaint etc. complete. |
64 | Item No 9 Providing internal cement plaster 20mm thick in double coat in cement mortar 1:3 without neeru finish to stone masonry surfaces, in all positions including scaffolding and curing complete. Spec. No.: Bd.L.3 Page No. 368 |
65 | Item No 10 Providing sand faced plaster externally in cement mortar using Kharsalia/Kasaba or similar type of sand, in all positions including base coat of 15mm thick in C.M. 1:4 using waterproofing compound at 1kg.per cement bag, curing the same for not less than 3 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8mm thick in C.M. 1:4, finishing the surface by taking out grains and curing for fourteen days, scaffolding etc. complete. Spec. No.: Bd.L.7 Page No. 369 |
66 | Item No. 11 Providing andfixing in position copperlightenig conductor including copper rod of 20 mm dia as per upper terminal 1.5 M long with a knob at end and with conical spike at top, copper tape conductor 20 x 3 mm size, copper earth plate of 3mm thick and 0.81 sqm in area, clamps at 1 M c/c including necessary excavation, laying and fixing the conductor, providing and fixing 40 mm G.I.pipe upto 3 M hight from ground and 0.5 M below ground including making all connection, filling the earthing pit with charcoal, salt etc.and refilling and watering, etc.complete as per specification laid down in relevent I.S. codes. |
67 | Item No. 12 Providing cement based water proofing treatment over slab (India water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface, applying a coat of cement slurry and mixed with approved water proofing compound and laying the brick bats, on bottom layer of c.m. (1:5) and mixed with approved water proofing compound, filling upto half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer, jointing of brick bats with c. m. 1:3 and mixed withapproved water proofing compound and finally top finishing with average 20 mm thick layer of same morter including finishing the surface smooth with cement slurry mixed with approved water proofing compound, marking the finished surface with false squares of 300mm x 300mm, making the junctions at the parapets rounded and tapered towards top for required height with drip mould at the junction of plaster and curing etc. covering 7 years guarantee on Court Fee Stamp paper of Rs. 100/- including ponding test etc complete |
68 | Item No 13 Providing and applying white wash in two coats on old /new plastered or masonry surface and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down, etc. complete. |
69 | Item No 14 Providing and applying washable oil bound distemper of approved colour and shade to old/ new surfaces, in three coats including scaffolding, preparing the surface to receive the priming coat and finishing coat etc. complete. |
70 | Item No15 Providing and applying two coats of Apex paint of approved manufacture and ofapproved colour and blistered surface including scaffolding if necessary andpreparing the surface curing etc. complete. |
71 | Item No. 16 Providing and making nesecessary internal electric "arrangement for pumphouse with all labour andmaterial etc.complete |
72 | Item No. 17 Providing and laying Rough Shahabad Stone Flooring 40 to 45 mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. Spec. No.: Bd.M.1 Page No. 379 |
73 | Raw Water Pumping Machinery in Balancing Tank Item No 1 :-Submersible PumpProviding, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pumpDischarge 41720 LPH at 11 meter head |
74 | Item No. 2:- M S pipes andSpecialsProviding and fabricating installing M S Pipes and special for suction & delivery side with jointing materials etc complete as per detailled specification.M S pipes & flanged ended specials of required dia. |
75 | Item No. 3 :- CIDF Valve. Providing installing commissioning of CIDF sluice valves PN-1 rating with satisfactory test & trial as per detailed specifications etc. complete.a) 100 mm dia sluice valve |
76 | b) 100 mm dia reflux valve |
77 | c) 50 mm dia air valve |
78 | Item No 4 :- Pressure gauge Providing, erecting, pressure gauge of 150 mm dia. Complete with syphon tube isolating cock suitable for 12 mm dia. G.I. pipe |
79 | Item No. 5:-Lifting Equipment a) Providing, erecting triple spur gear type chain pulley block suitable for 1 Tonne Capacity with 6 m Lift complete with load chain and hand chain suitable for above lift,tested to 50% overload as per IS 3832 carrying ISI mark. |
80 | b) Travelling trolley Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load. |
81 | Item No.6:-Control Panel board Providing , erecting and commissioning, industrial Cubicaltypecontrol panel boardandas per detailed specification. |
82 | Item No 7 :- Cable Providing, erecting, XLPE / PVC insulated armouredaluminium conductorOf following sizes 1100 V grade cable as per detailed specification attached.(a) 3.5 core 25 sq.mm cable from Transformer to Main Panel |
83 | (b) Submersible Copper conductor3 Core 4 sq.mm cable |
84 | Item No. 8 :- Earthing Providing, erecting giving test of earthing arrangement to all electrical equipment as per IE rules and as per detailed specifications. |
85 | Item No. 9 :-Electrifications Providing installing of electrificationsto pump house as per detailed specifications . |
86 | Item No. 10 :- Foundation Providing, constructing C.C. Foundation block in 1:2:4 proporation for supporting valves, specials, pipes, panel and starter as per detailed specifications. |
87 | Item No 11 :- ToolsProviding tools as per detailed specification |
88 | Item No. 12:- Electromagnetic Water meter Supplying,Instaling and commissioning electromagnetic flow meter EMF As per ISO 4064 for Raw/Pure water with accuracy +/- 0.50% of measured value and protection as per given specification for size 100 mm - 1000 mm including sensor transmitter surge arrestor cable GI duct of suitable size 25 mtrs built in GSM (with simcard and its charges valid for 36 months)including pipe cutting,levelling and installation of flow meter in the pipe line with necessary tool tackles cranesincluding 36 months guaranteeetc. complete as may be required at site and base on technical specification.150 mm dia |
89 | Raw Water Rising Main ( B T to WTP ) Item No. 1Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excludingoupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete160 mm dia.HDPE pipe |
90 | Item No. 2 Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.5% OF Pipe amount |
91 | Item No. 3Providing and supplying ISI standard MSspecials of required thickness with 3 coats ofpproved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. |
92 | Item No. 4 Excavation for Foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material up to a distance of 50 meters and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
93 | Item No. 5 Excavation for foundation / pipe trenches by all means in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer- In-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259)) |
94 | Item No. 6 Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers |
95 | Item No. 7 Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634Part 160 mm dia.HDPE pipe |
96 | Item No. 8 Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessaryquipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position160 mm dia.HDPE pipe |
97 | Item No. 9 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)In PCC M-150For Road Crossing |
98 | Item No. 10 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)For Concrete Blocks |
99 | Item No. 11 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F17/306) |
100 | Item No. 12 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts excluding consolidation, surcharging, etc. complete |
101 | Raw Water Pumping Machinery(RWS @ EX.BT- 1 TO WTP) Item No 1 :-Submersible PumpProviding, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pumpDischarge 41720 LPH at 11 meter head |
102 | Item No. 2:- M S pipes andSpecialsProviding and fabricating installing M S Pipes and special for suction & delivery side with jointing materials etc complete as per detailled specification.M S pipes & flanged ended specials of required dia. |
103 | Item No. 3 :- CIDF Valve.Providing installing commissioning of CIDF sluice valves PN-1 rating with satisfactory test & trial as per detailed specifications etc. complete.a) 100 mm dia sluice valve |
104 | b) 100 mm dia reflux valve |
105 | c) 50 mm dia air valve |
106 | Item No 4 :- Pressure gauge Providing, erecting, pressure gauge of 150 mm dia. Complete with syphon tube isolating cock suitable for 12 mm dia. G.I. pipe |
107 | Item No. 5:-Lifting Equipment a) Providing, erecting triple spur gear type chain pulley block suitable for 1 Tonne Capacity with 6 m Lift complete with load chain and hand chain suitable for above lift,tested to 50% overload as per IS 3832 carrying ISI mark. |
108 | b) Travelling trolley Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load. |
109 | Item No.6:-Control Panel board Providing , erecting and commissioning, industrial Cubicaltypecontrol panel boardandas per detailed specification. |
110 | Item No 7 :- Cable Providing, erecting, XLPE / PVC insulated armouredaluminium conductorOf following sizes 1100 V grade cable as per detailed specification attached.(a) 3.5 core 25 sq.mm cable from Transformer to Main Panel |
111 | (b) Submersible Copper conductor3 Core 4 sq.mm cable |
112 | Item No. 8 :- Earthing Providing, erecting giving test of earthing arrangement to all electrical equipment as per IE rules and as per detailed specifications. |
113 | Item No. 9 :-Electrifications Providing installing of electrificationsto pump house as per detailed specifications . |
114 | Item No. 10 :- Foundation Providing, constructing C.C. Foundation block in 1:2:4 proporation for supporting valves, specials, pipes, panel and starter as per detailed specifications. |
115 | Item No 11 :- ToolsProviding tools as per detailed specification |
116 | Item No. 12:- Electromagnetic Water meterSupplying,Instaling and commissioning electromagnetic flow meter EMF As per ISO 4064 for Raw/Pure water with accuracy +/- 0.50% of measured value and protection as per given specification for size 100 mm - 1000 mm including sensor transmitter surge arrestor cable GI duct of suitable size 25 mtrs built in GSM (with simcard and its charges valid for 36 months)including pipe cutting,levelling and installation of flow meter in the pipe line with necessary tool tackles cranesincluding 36 months guaranteeetc. complete as may be required at site and base on technical specification.150 mm dia |
117 | Pure Water Pumping Machinery Item No 1 :-Submersible monoblock Pump Providing, erecting and giving test of submersible pumpset conforming to IS 8034 and motor conforming to IS9283, with water proof winding. Pump shall be suitablefor various delivery head and discharge with stainlesssteel shaft. Motor suitable for working on 415 V ± 10%, 3Ph, 50 Hz A.C. Supply, with cable guard, thrustcarbon/fiber bearing to withstand entire hydraulic thrust.The pump set shall be suitable for direct coupling, withsuitable suction strainer. Pump should have suitabledischarge out let as per manufacturer"s design. Antithruststream lined non return valve shall be provided with thepump. 3 m submersible copper conductor cable in single/ double run and 2 pairs of suitable size erection clamp10 mm thick shall be provided with each pump. a) Discharge 22876 LPH at 53 meter head |
118 | b) Discharge 14611 LPH at 43 meter head |
119 | Item No. 2:- M S pipes andSpecialsProviding and fabricating installing M S Pipes and special for suction & delivery side with jointing materials etc complete as per detailled specification.M S pipes & flanged ended specials of required dia. |
120 | Item No. 3 :- CIDF Valve. Providing installing commissioning of CIDF sluice valves PN-1 rating with satisfactory test & trial as per detailed specifications etc. complete.a) 80 mm dia sluice valve |
121 | b) 80 mm dia reflux valve |
122 | c) 50 mm dia air valve |
123 | Item No 4 :- Pressure gauge Providing, erecting, pressure gauge of 150 mm dia. Complete with syphon tube isolating cock suitable for 12 mm dia. G.I. pipe |
124 | Item No. 5:-Lifting Equipment a) Providing, erecting triple spur gear type chain pulley block suitable for 1 Tonne Capacity with 6 m Lift complete with load chain and hand chain suitable for above lift,tested to 50% overload as per IS 3832 carrying ISI mark. |
125 | b) Travelling trolley Providing, erecting Travelling Trolley of capacity as below with 6 m lift, tested to 50% over load. |
126 | Item No.6:-Control Panel board Providing , erecting and commissioning, industrial Cubicaltypecontrol panel boardandas per detailed specification. |
127 | Item No 7 :- Cable Providing, erecting, XLPE / PVC insulated armouredaluminium conductorOf following sizes 1100 V grade cable as per detailed specification attached.(a) 3.5 core 35 sq.mm cable from Transformer to Main Panel |
128 | (b) Submersible Copper conductor3 Core 6 sq.mm cable |
129 | Item No. 8 :- Earthing Providing, erecting giving test of earthing arrangement to all electrical equipment as per IE rules and as per detailed specifications. |
130 | Item No. 9 :-Electrifications Providing installing of electrificationsto pump house as per detailed specifications . |
131 | Item No. 10 :- Foundation Providing, constructing C.C. Foundation block in 1:2:4 proporation for supporting valves, specials, pipes, panel and starter as per detailed specifications. |
132 | Item No 11 :- ToolsProviding tools as per detailed specification |
133 | Item No. 12:- Electromagnetic Water meterSupplying,Instaling and commissioning electromagnetic flow meter EMF As per ISO 4064 for Raw/Pure water with accuracy +/- 0.50% of measured value and protection as per given specification for size 100 mm - 1000 mm including sensor transmitter surge arrestor cable GI duct of suitable size 25 mtrs built in GSM (with simcard and its charges valid for 36 months)including pipe cutting,levelling and installation of flow meter in the pipe line with necessary tool tackles cranesincluding 36 months guaranteeetc. complete as may be required at site and base on technical specification.150 mm dia |
134 | Pure Water Rising Main Item No. 1 Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excludingoupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete 90 mm dia.HDPE pipe |
135 | 110 mm dia.HDPE pipe |
136 | 140 mm dia.HDPE pipe |
137 | 160 mm dia.HDPE pipe |
138 | Item No. 2 Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete.5% OF Pipe amount |
139 | Item No. 3Providing and supplying ISI standard MSspecials of required thickness with 3 coats ofpproved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. |
140 | Item No. 4 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.PN - 1.0 WITHOUT BYPASS 80 MM |
141 | 100 MM |
142 | 125 MM |
143 | 150 MM |
144 | Scour Sluice Valve P.N-1.0 Without Bypass 65 MM |
145 | Item No. 5 Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete Air Valve Single Ball Flanged / Screwed Type - PN -1.632 mm |
146 | Item No. 6 Excavation for Foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material up to a distance of 50 meters and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
147 | Item No. 7 Excavation for foundation / pipe trenches by all means in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer- In-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259)) |
148 | Item No. 8 Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers |
149 | Item No. 9 Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent ISCode complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634Part 90 mm dia.HDPE pipe |
150 | 110 mm dia.HDPE pipe |
151 | 140 mm dia.HDPE pipe |
152 | 160 mm dia.HDPE pipe |
153 | Item No. 10 Lowering, laying and jointing in position following CID/F Reflux valves & Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.PN - 1.0 WITHOUT BYPASS80 MM |
154 | 100 MM |
155 | 125 MM |
156 | 150 MM |
157 | Scour Sluice Valve P.N-1.0 Without Bypass65 MM |
158 | Item No. 11 Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) Up to 150 mm dia. |
159 | Item No.12 Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position 90 mm dia.HDPE pipe |
160 | 110 mm dia.HDPE pipe |
161 | 140 mm dia.HDPE pipe |
162 | 160 mm dia.HDPE pipe |
163 | Item No. 13 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete.In PCC M-150 For Road Crossing (Cement 5.90 bags / cum) |
164 | Item No. 14 Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
165 | Item No. 15 Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F17/306) |
166 | Item No. 16 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in C.M. 1:5proportion 12 mm thick cement plaster in cm 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or cm thick slab etc. complete as directed by Engineer-in-chargeSize 0.9 X 0.9 X 1.2. |
167 | Item No. 17 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts excluding consolidation, surcharging, etc. complete |
168 | RCC ESR Item No. 1 Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipeassembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers,water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint to the structure including roof slab, epoxy painting to internal surface and antitermite treatment for nderground parts of the structure and giving satisfactory water tightness test as per I.S. code. Anil Nirmal Wasti Capacity - 17000 Lit Staging height - 12.0 M |
169 | Dilip Pawar WastiCapacity - 31000 Lit Staging height - 16.0 M |
170 | Gaothan Capacity - 40000 Lit Staging height - 11.0 M |
171 | Bhusal Wasti Capacity - 75000 Lit Staging height - 15.0 M |
172 | Item No. 2 Providing and supplying ISI standard welded DI double flanged pipe excluding GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to store / site, unloading, stacking etc. complete as directed by Engineer -in- charge. (for 2.75 m bare pipe)Inlet pipe 100MM |
173 | Outlet Pipe 100 MM |
174 | Outlet Pipe 150 MM |
175 | OVER FLOW 100 MM |
176 | OVER FLOW 150 MM |
177 | Bypass 100 MM |
178 | Item No. 3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. PN - 1.0 WITHOUT BYPASS 100 MMSV (INLET,OUTLET & BYPASS) |
179 | 150 MMSV (INLET,OUTLET & BYPASS) |
180 | 80 MM WASHOUT |
181 | Item No. 4 Providing and supplying ISI standard D.I. specials & fittings with sealing rubber gasket of S.B.R.,complete with Cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for D.I. pipesexcluding cost of all labours and materialsandtransportation to stores / site, loading , unloading excluding all taxes , etc. complete.ISI standard D.I. specials |
182 | Distribution System Item No. 1 Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excludingoupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. completeHDPE PE-100@6kg/sqm PipeFor Distribution 75 mm Dia |
183 | 90mm Dia |
184 | 110mm Dia |
185 | 125mm Dia |
186 | 140mm Dia |
187 | Item No. 2 Providing & Supply of Electro Fusion Fittings in accordance with BS EN12201: Part-3 suitable for drinking water with in black/ blue colour manufactured from compounded PE80/ PE100 virgin polymer and compatible with PE80/PE100 pipes, in pressure rating SDR11 with min PN12.5 rated for water application and shall be inclusive of all cost such as testing, inspection charges, transportation up to store, transit insurance, loading, unloading, stacking excluding GST leviedby GOI & GOM in all respect, etc. complete. 5% cost of pipe |
188 | Item No. 3 Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.80 mm Dia |
189 | 100 mm Dia |
190 | 125 mm Dia |
191 | 150mm Dia |
192 | Item No. 4 Excavation for Foundation / pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material up to a distance of 50 meters and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
193 | Item No5 Excavation for foundation / pipe trenches by all means in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer- In-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(Bd-A-2/259)) |
194 | Item No. 6 Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers |
195 | Item No. 7 Lowering, Laying and Jointing H. D. P. E./M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 HDPE PE-100@6kg/sqm PipeFor Distribution75 mm Dia |
196 | 90mm Dia |
197 | 110mm Dia |
198 | 125mm Dia |
199 | 140mm Dia |
200 | Item No. 8 Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of sluice valves) CIDF Sluice Valve(PN1)For Distribution 80 mm Dia |
201 | 100 mm Dia |
202 | 125 mm Dia |
203 | 150mm Dia |
204 | Item No. 9 Providing and fixing C.I. road box including loading, unloading and carting to site of work including all necessary excavation in all types of strata and fixing in murum packing, etc. complete. Size 100 mm x 225 mm (20 kg) |
205 | Item No.10 Hydraulic testing of D.I./HDPE pipeline to specified pressure cost of all materials and labour and water for testing for the length upto 1 km, using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary.HDPE PE-100@6kg/sqm PipeFor Distribution 75 mm Dia |
206 | 90mm Dia |
207 | 110mm Dia |
208 | 125mm Dia |
209 | 140mm Dia |
210 | Item No.11 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete |
211 | Trial Run Item No-1 Commisioning running and maintaining the scheme to quntities, rated capacity, including manning necessary personnel such as operatore, valveman etc.as per requirment of the scheme and who should also administer chemical dose for a period of1 month for individual scheme and 3 months for regional scheme together wit training of personnel spared by MJP/Local Body and handling over the scheme to Local Body after completion of the above period as directed by Engineer-in-charge Note : Required chemicals to be supplied by Departement free of cost and electricity bill will also paid by the Department a) For single village (3 month) with WTP |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy