Construction Of Atc Tower Cum Technical Block At Civil Aerodrome Vadodara.Sh:- Sitc Of Airfield Lighting Control And Monitoring System ( Alcms ) Including Aicmc Of Five Years At Vadodara Airport, vadodara-Gujarat

Airports Authority Of India has published Construction Of Atc Tower Cum Technical Block At Civil Aerodrome Vadodara.Sh:- Sitc Of Airfield Lighting Control And Monitoring System ( Alcms ) Including Aicmc Of Five Years At Vadodara Airport. Submission Date for this Tender is 17-09-2022. Electrification Work Tenders in vadodara Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

33453630
Corrigendum : Construction Of Atc Tower Cum Technical Block At Civil Aerodrome Vadodara.Sh:- Sitc Of Airfield Lighting Control And Monitoring System ( Alcms ) Including Aicmc Of Five Years At Vadodara Airport
Open Tender
Indian
Gujarat
vadodara
17-09-2022

Tender Details

Construction Of Atc Tower Cum Technical Block At Civil Aerodrome Vadodara.Sh:- Sitc Of Airfield Lighting Control And Monitoring System ( Alcms ) Including Aicmc Of Five Years At Vadodara Airport

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Aug-2022 CORRIGENDUM - 1 Date 10-09-2022
2 07-Sep-2022 CORRIGENDUM - 2 Date 17-09-2022
3 07-Sep-2022 CORRIGENDUM - 2 Technical Bid 17-09-2022

Key Value

Document Fees
INR 1180 /-
EMD
INR 123947.0 /-
Tender Value
INR 61.97 Lakhs /-

BOQ Items

Name of Work:Construction of ATC Tower Cum Technical Block at Civil Aerodrome Vadodara. SH:- SITC of Airfield Lighting Control and Monitoring System (ALCMS)including AICMC of Five years at Vadodara Airport.
Sl. No. Item Description
1SH-I :- SITC of ALCMS Design, supply, installation, testing & commissioning of Airfield Lighting Control & Monitoring System (ALCMS), Type "L 890 BB" to the requirements of FAA Advisory Circular No. AC 150/5345 - 56B (Current edition) and additional circuits/ mechanisms/ interfaces for control & monitoring of constant current regulators (CCRs) & fixed circuits such as Landing - H, Wind cones, Apron High Mast flood lightsBeacon lights etc., as mentioned in Annexure-1, network diagram, maintaining data and event log records, suitable interface to make them compatible with ALCMS, Data & Power Cabling, Earthing etc., including PLC and I/O modules, all hardwares and softwares, licenses & other items as required for successful operation of the ALCMS system etc. to ensure failsafe, expandable and future proof system in line with the scope of work, details of equipments, equipments specification, performance criteria etc., complete as per site requirement and tender specifications. Two vault processor, Two touch screen, Two monitor(one for tower and one for CCR room) complete with industrial grade computer & UPS should be provided for running in parallel for redundancy in operation etc complete as per site requirement and tender specifications.
2Supply and laying of Single mode 6 core, armoured Optic Fibre Cable (OFC) (ISI marked) conforming to ITU-T G.652 and IEC- 60794 with up to date amendments, etc., complete as required. through existing HDPE pipe of 50 mm dia.
3Supply of 50mm dia.(O.D.) HDPE (High Density Polyethylene) duct of grade PE80, PN6 ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 4984:1995 with latest ammendments complete as required.
4Laying of 50mm HDPE pipe along with all accessories like socket, bend, couplers etc. in the existing existing RCC/HUME/metal pipe/ masonry duct/ trench complete as required.
5Laying of 50mm HDPE pipe along with all accessories like socket,couplers etc. on wall surface/cable tray clamped with 1mm thick saddle at required intervals as required.
6Supply and fixing of Single mode 6 core, armoured Optic Fibre Cable (OFC) (ISI marked) conforming to ITU-T G.652 and IEC- 60794 with up to date amendments, etc., as loop inside the vault processors/Open duct/ surface including providing cable tie/ mounting clamps etc., complete as required.
7Supply of 8c x 1.5 sq.mm. of XPLE insulated PVC sheathedarmouredcopper conductor control cable of 1.1KV grade confirming to IS 7098 (Part-I) with up to date ammendment etc. complete as required.
8Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
9SH-II :- AICMC of ALCMS All inclusive comprehensive maintenance of complete ALCMS & other related hardwares and softwares including all spares and consumables, providing full support during breakdown & trouble shooting, programming, carrying out quarterly routine maintenance checks, preventive and breakdown maintenance etc. as required as per good engineering practices, recommendations of the respective equipment manufacturers and instructions of engineer- in-charge for maintaining the systems. This includes keeping the system in acceptable functional and serviceable state etc. as specified including cost of all spare parts. First Year (after Completion of one year DLP)
10Second Year (after Completion of one year DLP)
11Third Year (after Completion of one year DLP)
12Fourth Year (after Completion of one year DLP)
13Fifth Year (after Completion of one year DLP)