Repair / Maintenance Of Conventional And Led Type Fittings And Fixtures, Tube Lights , Ceiling Lights, Bulkhead Fittings , Mirror Lights , Wall Lamp Etc ) And Its Allied Works Zone B At Zakhama Military Station Under Age ( I ) Zakhama, zakhama-Nagaland

Military Engineer Services-MES has published Repair / Maintenance Of Conventional And Led Type Fittings And Fixtures, Tube Lights , Ceiling Lights, Bulkhead Fittings , Mirror Lights , Wall Lamp Etc ) And Its Allied Works Zone B At Zakhama Military Station Under Age ( I ) Zakhama. Submission Date for this Tender is 05-09-2022. Electrification Work Tenders in zakhama Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

33451808
Corrigendum : Repair / Maintenance Of Conventional And Led Type Fittings And Fixtures, Tube Lights , Ceiling Lights, Bulkhead Fittings , Mirror Lights , Wall Lamp Etc ) And Its Allied Works Zone B At Zakhama Military Station Under Age ( I ) Zakhama
Open Tender
Indian
Nagaland
zakhama
05-09-2022

Tender Details

Repair / Maintenance Of Conventional And Led Type Fittings And Fixtures, Tube Lights , Ceiling Lights, Bulkhead Fittings , Mirror Lights , Wall Lamp Etc ) And Its Allied Works Zone B At Zakhama Military Station Under Age ( I ) Zakhama.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-09-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIRS/ MAINTENANCEOF CONVENTIONAL & LED TYPE FITTINGS & FIXTURES, TUBE LIGHTS , CEILING LIGHTS, BULKHEAD FITTINGS , MIRROR LIGHTS , WALL LAMP ETC) AND ITS ALLIED WORKSZONE "B" AT ZAKHAMA MILITARY STATION UNDER AGE(I) ZAKHAMA.
Sl. No. Item Description
1Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
2M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
3All as per item serial No 02 here-in-before but for One 3 pin 5 Amp switch socket outlet on same board with other switches.
4All as per item serial No 02 here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board.
5All as per item serial No 02 here-in-before butfor one 5A3 pin socket outlet independent but below the switch board of light points in the same vertical plane.
6All as per item serial No 02 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
7Allas per item serial No 02 here-in-before butfor One bell point controlled by one switch 5 Amps bell push.
8S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
9S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
10S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
11S&F bell push, flush type, 5 Amps complete all as specified and as directed.
12S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
13S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
14S & F lamp holder, insulated, PVC / polycarbonate /bakelite bodyincluding 9W LED lampscomplete all as specified and as directed.
15S&F in repairs, LED box type fitting pre-wired including LED tube 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on PVC blockcomplete all as directed.Make:- Jaquar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or Havells Model-LUMILINEPLUSBS20WLED865SPCSS or equivalent model of make Philips /GE/Crompton
16S&F in repairs,LED (single sided connection) ) ultra bright polycarbonate tube light 20 watt,6500K retrofit in existing flourescent tube light fittings complete all as speciifed and as directed. Make:- Havells Model- LHLDDCXCML8Q020 or equivalent /Phillips. /crompton/Bajaj/Jaquar
17S&F in repairs,LED (double sided connection) ) ultra bright polycarbonate tube light 20 watt,6500K retrofit in existing flourescent tube light fittings complete all as speciifed and as directed. Make:- Havells Model-CRYSTAL 1213T8DSTL20WLED865SGLASS or equivalent /Phillips. /crompton/Bajaj/Jaquar
18S&F in repairs, Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips /Crompton /GE.
19S&F in repairs,34 watt LED recessed mountedluminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling and fixture size in mm (LxWxH) 595x595x70 complete all as specified and directed. Make : Havells Model-PLUTONEO2x2PLR34WLED840S/ PLUTONEO2x2PLR34WLED857S or equivalent model in make of Philips/ Crompton/Bajaj
20S&F in repair 1 LT Opal Glass with Chrome Finishing Wall Lamp including E-14 LED 4W x 1 bulb, warm white complete all as specified and as directed. Make :Jaquar Model :KWB-CHR-MB12021151A or equivalent make of Phiilips/ Crompton.
21S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43/42 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11or Havells Model-DHDMSHODCW08 equivalent model in Siemens / Schneider
22S&F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43/42 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 10 or Havells Model-DHDPSHOSRW04 or equivalent model in Siemens / Schneider/L&T
23S & F in repairs, sheet metal enclosurewhen MCBto be used 2 way, Single pole & neutralwithout bus barcomplete all as specified and asdirected..
24S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 250 mm x 150 mm and 50 mm deep complete all as specified and as directed.
25S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mmthick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed.
26S&FMCB SPN63Amps, 415V,50 HZ,C series breaking capacity 10KA complete all as specified and as directed. Make- Legrand ,cat part no-4086 20 or Havells Model-DHMGCSNF063 or equivalent model of make Siemens/Schnider.
27S&F MCBs, SPN 6 to 32 Amps, 10 KA,"C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or Havells Model-DHMGCSNF06-32 or equivalent model in Siemens / Schneider/L&T
28S&F MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 or Havells Model-DHMGBSPF006-032 orequivalent model in Siemens / Schneider/L&T
29S & F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, "C" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :-Legrand Model 4085 90 to 95 or Havells Model-DHMGBSPF006-032 orequivalent model in Siemens / Schneider/L&T
30S&F 1100 volts grade heavy duty flat cable ofsize 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking out old cable of any description complete all as specified and as directed.
31S&F 1100 volts grade heavy duty flat cable ofsize 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking out old cable of any description complete all as specified and as directed.
32S&F 1100 volts grade heavy duty flat cable ofsize 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking out old cable of any description complete all as specified and as directed.
33M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
34M&L forGI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 3.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail