Fire Fighting System At Sdo Complex At Bawal In Rewari Distt. Reinvited, Rewari-Haryana

Public Works Department-PWD has published Fire Fighting System At Sdo Complex At Bawal In Rewari Distt. Reinvited. Submission Date for this Tender is 19-08-2022. Fire Fighting Consumable Tenders in Rewari Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

33391754
Fire Fighting System At Sdo Complex At Bawal In Rewari Distt. Reinvited
Open Tender
Indian
Haryana
Rewari
19-08-2022

Tender Details

Fire Fighting System At Sdo Complex At Bawal In Rewari Distt. Reinvited

Key Value

Document Fees
INR 5000 /-
EMD
INR 111000.0 /-
Tender Value
INR 55.47 Lakhs /-

BOQ Items

Name of Work:FIRE FIGHTING SYSTEM AT SDO COMPLEX BAWAL IN REWARI DISTRICT. (RE-INVITED) (Appd. Cost Rs. 55.47 lacs)
Sl. No. Item Description
1FIRE HYDRANT SYSTEM Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to IS 3589/ IS 1239 including Welding ,fittings like elbows ,tees ,flanges,tapers ,nuts bolt ,gaskets etc . And fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complite as required . MAKE HISAR JINDEL , TATA ,PARKSH SURYA . (A) 250 mm dia (MINIMUM 6.3 MM THIKNESS) (NS)
2(B) 200 mm dia (MINIMUM 6.3 MM THIKNESS) (NS)
3(C ) 100 mm dia (NS)
4(D) 80 mm dia (NS)
5(E) 25 mm dia (NS)
6Providing laying ,testing & commissioning of ( C ) class heavy duty MS pipe conforming to ISIS 1239 /3589 i/c fitting like elbows ,tees ,flanges ,tapers ,nuts bolt , gaskets etc .in ground including welding ,excavation & providing cement concrete blocks as supports , anticorrosive treatment with coaltar /asphalt tape as per IS 10221 reffilling the trench etc .of following sizes complete as required make PYPECOAT/COALTEK. (A) 150 mm dia (MINIMUM 6.3 MM THIKNESS) (NS).
7Supplying and fixing single headed internal and external yard hydrent valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 ( TYPE -A ) with blank stainless steel cap and chain as required (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ Safex /) (DSR code No. 9.2)
8SITC ofINTERNAL OR EXTERNAL weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For external hydrant system) (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX / MINIMAX )( N.S )
9Supplying and fixing 63 mm dia ,15 m long RRL hose pipe with 63 mm dia male and femaile coupling duly bond with GI WIRE , RIVETS ETC . CONFORMING TO IS 636 (Type -A ) as required . (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX / MINIMAX ) (DSR code No. 16.2)
10Supplying & fixing 63 mm dia Stainless Steel (grade 304 ) short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 sutitable for instantaneous connection to iIS 903 sutitable for instantaneous connection to interconnect hose pipe coupling as required (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX / MINIMAX). (DSR code No. 18.2)
11Supplying and fixing firsr-aid Hose Reel with MS construction spray painted in post office red , conforming to IS 884 complite with the follwing as required . 20 mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS 12585. 20 mm normal internal dia gun metal globe & nozzle. Drum and brackets for fixing the equipmets on wall.connections from riser with 25 mm dia stop gunmetal valve & MSpipe and socket (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX / MINIMAX ) (DSR Code No.17.1)
12Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd , for sutitable dia MS pipe connection conforming to IS 904 AS REQUIRED .4 WAY -150 mm dia MS pipe(MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX / MINIMAX ) (DSR code No. 19.2).
13Providing , installation , testing and commissioning of stainless steel Y- strainer fabricated out of 1.6 mm thick stainless steel, grade 304 , sheet with 3 mm dia hole with stainless steel flange . 250 mm dia . KARTAR / SANT (DSR code No. 15.5)
14Supplying and fixing air vessel made of 250 mm dia ,8 mm thick MS sheet , 1200 mm in height with air release valve on top and flanged connection to riser , drain arrangement with 25 mm dia gun metal wheel valve with required accessories , pressure gauge and paintingwith synthetic enamel paint of approved shade as required . (MAKE: / FIRE CUT /NEW AGE/ SAFEX / MINIMAX ) (DSR code No. 20)
15SITC OF Providing & Fixing ofair vessel 450/1600 0mm dia,height with dish top made in 6mm thick ms pipecomplete with 20 mm dia brass air valve , 200mm diastop valve , pressure gauge ,stop cock, nipplefor fire control room (MAKE: / FIRE CUT / MINIMAX / NEW AGE/ SAFEX /) ( NS )
16Supplying and fixing orifice plate made out of 6mm thick stainless steel ( Grade 304 )with orrice of required size to be fitted between flange & landing valve of external and internal hydrent to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required .MAKE-SANT,LEADER,KARTAR / SAFEX OR EQULENT (DSR code No. 13)
17Supplying , fixing , testing and commissioning of butterfly vave of PN 1.6 rating with bronze /gunmetal seat duly ISI markedcomplete with nuts , bolt , washers ,gaskets conforming to IS 13095 OF FLOWING SIZES AS REQUIRED MAKE - KARTAR / SANT /ZOLOTO / KILOSKER. (A) 250 mm dia. (DSR code No. 11.8)
18(B) 150 mm dia. (DSR code No. 11.6)
19(C )100 mm dia. (DSR code No. 11.5)
20(D) 80 mm dia. (DSR code No. 11.4 )
21Providing , installation , testing and commissioning of non-return valve of following sizes confirming to IS 5312 complete with rubber gasket . GI bolt ,nuts , washers etc .as requiredMAKE - KARTAR / SANT /ZOLOTO / KILOSKER. (A) 250 mm dia (DSR code No. 14.9)
22(B) 150 mm dia (DSR code No. 14.7)
23(C )100 mm dia (DSR code No. 14.5)
24providing & fixing of pressure switch in M.S pipe line including connection MAKE INDIFUS /DANFOSE (DSR code No. 22)
25SITC of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.(MAKE - FIRE CUT / SAFEX /MINIMAX ( N.S )
26Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2. MAKE H.GURU/FIEBIG( N.S )
27MECHANICAL/ELECTRICAL PUMPS-Fire Hydrants Supplying , installation , testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following , complite in all respect , as required (Diesel Driven Pump ) horizontal type , multistage , centrifugal pump of cast of iron body and brinze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 OF Suitable HP ,1500 RPM water cooled with radiator , diesel engine conforming to relevant IS standard complete with autostarting mechanism , 12 /24 volt electric starting equipment , disel tank , exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick almunium sheet cladding, residebtial silencer , instruments and protection as per standard specification ,stop solenoid for auto stop in the ecent of fault with audio indications , painted with post office red colour etc .as required.M.S fabricated ,common base plate coupling ,coupling guard , foundation bolt etc. as required .1620 LPM 56 METAR HEAD (DSR-2.9 )
28Supplying , installation , testing and commissioning of electric driven Main Fire Pump suitable for automatic operation and consisting of following , complete in all respects , as required . (a ) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shaft , mechanical seal conforming to IS 1520 (b) suitable HP squirrel cage induction motor ,TEFC , synchronous speed 1500 RPM ,suitable for operation on 415 volt , 3 phase 50 Hz ,ac supply with IP 55 protection for enclosure , horizontal foot mounted type with class " F " insulations , conformingIS-325 FOR HYDRENT SYSTEMMAKEKILOSKER / LUBI. (NS) 1620 LPM suitable for56 Mtr Head. ( DSR-1.9 )
29Supplying , installation , testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following , complete in all respects , as required ; (Jockey Pump ) Horizontal type , multistage , centrifugal pump of cast iron body and bronze impeller with stainless steel shaft , mechanical seal conforming to IS; 1520 . Suitable HP squirell cage induction motor tefc type suitable for operation on 415 volt , 3 phase 50 HZ AC supply with IP 55 class of protection for enclosure , horzontal foot mounted type with class- " F "insulation,conforming to IS; 325 M .S fabricated common base plate , coupling ,coupling guard , foundation bolt etc as required . M.S fabricated bolt etc as required. Suitable cement concrete foundation duly plastered and with anti vibration pad MAKEKILOSKER / LUBI 180 LPM suitable for 56 Mtr( DSR-3.3 )
30Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following , complete in all respects , as required ; ( Terrace Pump ) (a) Horizontal type , multistage , centrifugal , split casing pump of cast iron body & bronze impeller with stainless steel shsft , mechanical confirming to IS; 1520(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volt ,3 phase ,50 Hz , AC supply with IP55 class of protection for enclosure , horiziontal foot mounted type with class - "F "insulation , conforming to IS- 325 (c) M.S fabricated common base plate ,coupling ,coupling guard , foundation bolt etc as required . (d) Suitable cement concrete foundation duly plastered and with anti vibration pads .450 LPM at 35 m head MAKEKILOSKER / LUBI (DSR- 4.1).
31SITC OF DOL type fire pump panel suitable for 450 lpm fire pump 415 V+/-6 volts,panel shall be free standing floor mounting sheet metal enclosed dust and verming proof.Panel shall be provided with heat shrinkable sleeves and shall be coloour coded. The panel shall be suitable for cable entry from top or bottem. The minimum fault rupturing for all incoming and outgoing switch/ breakers shall be 35 KA. The panel shall be fabricated.Auto mannual Starterswith change over system. MAKE ATTACK FIRE / FIRE CUT / HYDROTEC. (NS)
32Supply, installation, testing and commissioning of Dewatering Submersible type, vertical resting pump for dewatering from Underground sumps/Pits suitable to deliver 120 LPM at 10M head (minimum HP=1 ).415V, 50Hz, AC supply system, 2900 RPM, including providing required suspension or bracket supports, delivery connections, water proof windings, cable termination box etc suitable for under water application. The pumps shall have self level control including sensing probes or water/weather proof float switch for automatic controls complete KILOSKER ,LUBI ,CROMPTON. (NS) Note:Contractor to Guarantee the required discharge at required headfrom the pumps.The rating of motors to be property indicated for required head and discharge (selected for required duty points as per performance data of the pumps) The models to be got approved by the Architects before procurement.KW/HP/BHP of motors and engine shall finally be selected as per performance carve.Contractor to produce the required documents for such assessment at the time of purchase of pumps, motors and engines. MAKE KILOSKER / LUBI
33Supplying and making end termination with brass compression gland and almminium lugs for following size of PVCand PVCsheathed /XLPE almuminium conductor cable of 1.1 KV grade as required (MAKE:RR/FINOLEX/polycab ) (A) 3.COREx 95 sq. mm (From Fire Fighting Control Panel to main fireAND SPRINKLAR pump) (DSR E & M code No. 9.1.13)
34(B) 3 CORE x 35 sq. mm (From Fire Fighting panel to jockey pump) (DSRE & M code No. 9.1.10)
35( C) 2 core x 1.5 sq .mmFor pressure switch to fire panel and fire annuciator panel and flow switch ) supplying and drawing FRLS PVC insulated copper conductorcable (DSRE & M )code No. 1.17.2)
36( D ) 3.COREx 10 sq. mm (From Fire Fighting Control Panel to main fire pump)(DSRE & M code No.9.1 .7
37Fabrication , supply, insallation testing & commissioning of electrical control panel of cubical construction , floor mounted type , fabricated out of 2mm thick Crca sheet , compartmentalised with hinged lockable door ,dust and vermin proof ,powder coated of approved shade after 7 tanktreatment process , cable alley ,interconnection with suitable size copper conducor cable /solid copper strip , having switchgears and accessories , numbering etc , completein all respect ,suitable for main fire pump , pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoing , suitable for opreraton on 415v , 3 phase, 50 Hz Ac Supply with enclosure protection class IP 42 as required. INCOMING : 250 A , 50kA 4 pole MMCB ,lcs =100 %icu rating Digital Voltmeter 0-500 V with selector switch Ammeter (0-400 A ) with selector swtich & CTs etc . LED type RYB phase indicating lamps , ON , OFF , trip indicating lamps. Set of copper bus baar 500a. Outgoings ( Note ;- ALL outgoing feeder for pumps should have digital Ammeter with selector switches , and LED type ON ,OFF ,trip indicating lamps ) MAIN FIRE PUMP 125 A , 50 kA TPN MCCB , ics =100% icu , with fully automatic star /delta starter sutable for 75 hp pump with overload protection , current sensingtype single phase preventor complete with all acceessories and internal wiring required for automatic operation , selector switch for locl /remote ,auto / manwel /off opreation . JOCKEY PUMP - 63 A ,50kA TPN MCCB ,ICS= 100 % 1CU with suitableHP fully automatic star/delta starter with overload protection ,current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation , selector switch for local / remote ,auto /manual /off operation . DIESEL ENGINE CONTROL- Control for diesel engine comprising - Automatic / Manual selctor switch & 3 attempt starting device , timers and relays as required , push buttons , start /stop in manual modeindication lamp for high /low lub ,oil pressure ,high water temp and engine on indication . Battery charger suitble for 12 V /24 V DC with boost and trickle selectorswitch , 0-30 V DC volt meter , and 0-20 A DC Ammeter , All standard relays and accessories for automatic opretion of diesel engineSystem controller. Designing Supply installation , testing and commissioning of system controller to control operation of main electric fire pump ,disel pump ,pressurization pump in sequence as per specification consisting of relays ,timers sensors , annunciation window for fault indication ,complite as per specificationsMAKE fire cut /attack fire /hydrotec (DSR -5.1 )
38AUTO GLOW EXIT SIGNS AUTOGLOW EXIT SIGNS AND INDICATION SIGNS SIZE 12 "x 6", MAKE FIRE CUT AND ATTACK FIRE ,DP lndication every exit point,fire point,fire extinguisher . ( N.S )
39FIRE EXTINGUISHERS SUPPLY AND INSTALLATION of ISI marked (ISI MARK 15683) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve , dischargeone metar long hose of . meter complete in all respect withexplosive certificate .MAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE. (NS)
40SITC of ISI marked (IS: 15683) portable ABC multipurpose filled by 90% (MAP ) mono amonioum phosphatepowder , nitrogen pressurised type fire extinguisher, Capacity 6 kg with 90% map complete in all resp.MAKE MAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE ( N.S )
41SITC of Clean Agenttype ISI mark IS code 15683 2006Fire Extinguisher capacity: 2 kglocation - o.t room ,nursing station ,labmachinry room pantry kitchenMAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE. (NS)
42SITC of 5 kg modular type self operated on 68o temperature Clean Agenttype CE certifiedFire Extinguisher filled with NAFPIV clean agent gas MAKE location electrical shaft ,electrical control room servar room other places where water or other camical are prohibited . MAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE. (NS).
43SITC of 50 KG DCP (Dry Chemical Powder) Trolley type fire extinguisher as per IS 16018I jet length minimum 8 mtr minimum discharge time 40-50 sec,tested on 30 kgf/cm2MAKE.location dg room , fire control room , ground floor of every block . MAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE. (NS).
44SITC of 50 KG Mechanical Foam AFFF Trolley type fire extinguisher as per IS 16018 jet length minimum 10 mtr minimum discharge time 60-180 sec,tested on 35 kgf/cm2 with 2 kg co2 external fire extinguisherMAKE location dg room , fire control room , ground floor of every block .MAKE SAFEX / MINIMAX / FIRE CUT / CEASE FIRE(NS)
45SITC of 9 ltr capacity Fire Bucket made in 16 guage MS filled by 9 kg sand with MS angle stand having arrangement of hanging 6 buckets with shed KARTAR /FIRE CUT. (NS)
46FIRE CHECK DOOR SITC OF 46 mm steel fire check door of 120 minut fire rating confirming to bs 476 part -22 and is 3614 part-11 fabricated with 2 no , 1mm thick galvnized steel sheet sandwiching with proprietary fire resistant insulation materials in between . The door frames are manufactured from 1.5mm thick galvanized steel sheet pressed from to double rebate profile of size 143mm x 57 mm . the door frame and door shutters to finish with powder coatingSITC OF 2HR FIRE RATED METAL DOOR MAKE. location- basement stair case , electrical cantrol room and all floor stir case where there is no natural vantilationMAKE= /LAKESTA /AGNI /INDIAN FIRE /FIRE CUT
47UG WATER TANK AND MACHINARY ROOM Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (As per HSR 22.181)
48Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.All kinds of soil (HSR 4.12.1)
49Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1.6)
50Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). [HSR. 6.16)
51Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and stringcourses, fillets, columns, pillars, piers, abutments, posts andstruts etc. above plinth level up to floor four level, excluding costof centering, shuttering, finishing and reinforcement :[HSR. 6.15.1)
5212 mm cement plaster of mix : (HSR 11.5.4)
531 O mm thick cement plaster (HSR 11.4.2)
54Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length includinghooks, if any, separately for different diameters as actually usedin work , excluding overlaps. Wastage, overlaps, couplings,welded joints, spacer bars, chairs, stays, hangers and annealedsteel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to beincluded in the rates for reinforcement.. (HSR 6.33.6)
55Providing and laying of brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:(HSR 10.33.1)
56Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement: 6 coarse sand). (HSR 7.20.2)
57Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) 40mm thick(HSR 6.8.2)
58Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confonning to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar 1 :6 (1 cement : 6 coarse sand) : With Modular bricks (HSR 7.23.2)
59Half brick masonry with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level.Cement mortar 1 :4 ( 1 cement :4 coarse sand)(HSR 7.28.2)
6010 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1 :3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: With common burnt clay non-modular brick tile of class sqm designation 1 O (HSR 9.11.1)
61Bottom Khurra on ground 1.2mx0.60m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:11 including 12mm thick cement plaster 1:3 (HSR 9.18)
62Providing gola 75x75 mm in cement concrete 1 :2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase [HSR 9.17.1]
63Providing and fixing on wall face Unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketedpipes 110 mm diameter[HSR 9.57.2]
64Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion. 110 mm Bend[HSR 9.58.5.2]
65Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.[HSR 4.33]
66Providing and laying of Conglomerate floor 25 mm thick cement concrete 1:2:4 on 100 mm cement concrete 1:8:16 and 100 mm sand or stone filling. [HSR 10.9]
6712 mm cement plaster of mix :1 :4 (1 cement: 4 fine sand)(HSR 11.5.3)
6815 mm cement plaster on the rough side of single or half brick wall of mix :1 :4 (1 cement: 4 fine sand) [HSR 11.6.1]
691 O mm thick cement plaste1 :3 (1 cement: 3 fine sand) [HSR 11.4.2]
70Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand):Flush / Ruled/ Struck or weathered pointing [HSR 11.25.1]
71Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand)Flush/ Ruled/ Struck or weathered pointing [HSR 11.26.1]
72Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.[HSR 13.28]
73Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold ofmild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mildsteel welded or rigidly fixed together by mechanical means, including M.S.pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primerafter pre-treatment of the surface as directed by Engineer-in-charge:Fixing with adjustable lugs with split end tail to each jamb (a) Door and Window frame of size 89mmx50mm with 40mm wide single rebate. [HSR13.3.1.1]
74Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm [HSR 12.98.1]
75Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISi marked M.S. pressed butt hinges bright finished ofrequired size with necessary screws.Kiln seasoned and chemically treated Hollock wood30 mm thick [HSR 12.10.2.2]
76Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.[HSR 23.8.4]
77Planking of commercial hard wood, such as Hollock, champ, chikrassy andchaplash etc., (Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln-seasoned) planed on both sides, rebated and fixedin position, including nails and screws, etc: 40mm thick[HSR 12.24.3]
78Preparation of ply wood surface for painting including sand paperingthe surface and applying filling with approved quality filler consisting of whitelead, linseed oil, varnish and chalk mitti including finishing the surface torequired finish complete.[HSR 11.76]
79Applying pink primer or aluminium priming coat on wood work includingpreparation of surface, Knotting and stopping etc.[HSR 11.77]
80Painting two coats excluding priming coat with synthetic enamel paint in allshades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [HSR 11.78]
81With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works [HSR 11.68.3]
82Painting the wooden I metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work [HSR11.82.1
83White washing with lime to give an even shade New work (three or more coats)[HSR 11.61.1]
84Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of white washingwith lime[HSR 11.62.1]
85Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two or more coats) over and including water thinnablepriming coat with cement primer[HSR 11.64]
86Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/1 O sqm overand including priming coat of exterior primer applied @ 2.20 kg/10 sqm)[HSR11.95.1]
87Providing & fixing UV stabilised fibreglass reinforced plastic sheet roofing upto any pitch, including fixing with polymer coated "J" or "L" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost ofpurlins, rafters, trusses etc. The sheets shall be manufactured out of 2400TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resinsystem underapproximately 2400 psi and hot cured. They shall be of uniformpigmentation and thickness without air pockets and shall conform to IS 10192and IS 12866.The sheets shall be opaque or translucent, clear or pigmented,textured or smooth as specified.2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3"or 6" ) as specified [HSR 9.32.1]
88Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 5.5 mm thick glass panes [HSR 13.10.2] Note:- 1. In case of any difference in the unit & nomenclature of any of the HSR Items of Civil, P.H.,depicted in this DNIT and that given in HSR, the unit and nomenclature given in HSR shall be applicable. 2. Only reputed make material will be used (make/brand exhibited in HSRand exhibited in approved standard document) as approved by Engineer-in-charge, while executing various items/works at site.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail