Repair Maintenance Of Cooling Appliances Such As Acs Water Coolers Refrigerators Desert Coolers Voltage Stabilizers Etc Alongiwth Connected Works And Repair Maint Of Summer Appliances Such As Ceiling Fan Exhaust Fans Fresh Air Fans Etc Under Ge ( E ) M, mathura-Uttar Pradesh

Military Engineer Services-MES has published Repair Maintenance Of Cooling Appliances Such As Acs Water Coolers Refrigerators Desert Coolers Voltage Stabilizers Etc Alongiwth Connected Works And Repair Maint Of Summer Appliances Such As Ceiling Fan Exhaust Fans Fresh Air Fans Etc Under Ge ( E ) M. Submission Date for this Tender is 30-08-2022. Voltage Stabiliser Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33380470
Corrigendum : Repair Maintenance Of Cooling Appliances Such As Acs Water Coolers Refrigerators Desert Coolers Voltage Stabilizers Etc Alongiwth Connected Works And Repair Maint Of Summer Appliances Such As Ceiling Fan Exhaust Fans Fresh Air Fans Etc Under Ge ( E ) M
Open Tender
Indian
Uttar Pradesh
mathura
30-08-2022

Tender Details

Repair Maintenance Of Cooling Appliances Such As Acs Water Coolers Refrigerators Desert Coolers Voltage Stabilizers Etc Alongiwth Connected Works And Repair Maint Of Summer Appliances Such As Ceiling Fan Exhaust Fans Fresh Air Fans Etc Under Ge ( E ) Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Aug-2022 AMENDMENT BOQ 23-08-2022
2 12-Aug-2022 AMENDMENT Other 23-08-2022
3 23-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work:REPAIR, MAINT OF COOLING APPLIANCEs SUCH AS ACs, WATER COOLERs, REFRIGERATORs, DESERT COOLERs, VOLTAGE STABILIZERs ETC ALONGIWTH CONNECTED WORKS AND REPAIR, MAINT OF SUMMER APPLIANCEs SUCH AS CEILING FAN, EXHAUST FANs, FRESH AIR FANs ETC UNDER GE(E) MATHURA
Sl. No. Item Description
1Taking down of window/split AC 1.5/2.0tonne of any make opening complete. Servicing of AC components carefully such as cleaning with chemical solution and soft nylon brush and change of air filters,tightnining of loose screw, checking wiring connection and tightening the same and rectification of defects if any assembling the same with body balancing and fixing in position and testing in the presence of Engineer-in-Charge complete all as specified and as directed. Note :- (i) Cost of unserviceable major parts as required shall be measured and paid separetaly under relevant items under this BOQ. (ii) Servicing of same AC should be after minimum gap of six month of previous servicing.
2Supply and fix in repairscompressor sealed unit of the following appliances. New compressor shall be of the same type (rotary/reciprocating) and make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/Sriram/Panasonic/complete including replacement of copper tubing/capillary strainer etc, testing and commissioning in the presence of Engineer -in-charge to entire satisfaction complete all as specified and as directed Note:- Gas Filling is included in new compressor rates.
3Window type air conditioning of capacity 1.5 Ton.
4Window type air conditioning of capacity 2.0Ton.
5Split type AC 1.5 Ton capacity.
6Split type AC 2.0 Ton capacity.
7Cutting of worn out bottom portion welded properly of bottom tray fabricted out of 20 guage MS CRC sheet for window type ACs capacity 1.5/2.0 ton complete all as specified and as directed.
8Re-alignment of split AC 1.5/2.0 ton capacity including cutting of wall and making hole and change of liquid lines position in wall/roof by means of making sufficient grooves/channels and making good the disturbed surface including surface finish to match the exisingfinish with testing complete all as specified and as directed.
9Supply & fix in repairs running/starting capacitors of the following capacities for AC"s complete all as specified and as directed. Make :- Siemens/Epcos/KS electromech/Tibcon
104/5/6 Mfd.
1136/45 Mfd.
1280/100 Mfd.
13Supply & fix in repairs selector switch complete with knob of compatible size and model suitable forwindow type ACs of capacity upto 2 Tonne complete all as specified and as directed.
14Supply & fix in repairs starting relay suitable for following capacity of AC"s.
15Window type room air conditioners of 1.5/2.0 TR capacity complete all as specified and as directed.
16Split type AC 1.5/2.0 Ton complete all as specified and as directed.
17Contactor relay for split AC 1.5/2.0 TR complete all as specified and as directed.
18Supply & fix in repairs thermostats of following capacity window/split ACs:-
19Window type room air conditioners of capacity 1.5/2.0 Ton complete all as specified and directed.
20Split type room air conditioners of capacity 1.5/2.0 Ton complete all as specified and directed.
21Supply & fix in repairs overload protector of the following type and capacity AC"s:-
22Window type room air conditioners of capacity 1.5/2.0 Ton complete all as specified and directed.
23Split type room air conditioners of capacity 1.5/2.0 Ton complete all as specified and directed.
24Supply & fix in repairs capper condenser unit of the followingtype and capacity appliances including making of all connections complete as specified and directed by Engr-in-Charge. Make : Hitachi/Voltas/LG/Carrier/Blue star/Daikin/ LLyod/Sriram/Panasonic
25Window type room air conditioner of capacity 1.5/2.0 complete all as specified and directed.
26Split type room air conditioner of capacity 1.5/2.0 Ton complete all as specified and directed.
27Supply & fix in repairs ofevaporator coil for the followingtype and capacity air conditioner"s:-
28Window type room air conditioning of capacity 1.5/2.0 Ton capacity complete all as specified and as directed.
29Split type room air conditioner of capacity 1.5/2.0 Ton complete all as specified and directed.
30Supply & fix in repairs metal clad/sheet metal plug and socket with a 2 pin and earth plug and 20 Amps SP MCB including making all connections complete complete all as specified and directed. .
31Supply & fix in repairs indoor unit of split AC 1.5 toncapacity of make as existing at site single phase 230v, cooling/condensing coil assembly, electric fan motor with blower drum, control panel, front grill with nut/screws etc for fixing in wallcomplete set all as per specified and as directed.
32Supply & fix in repairs of indoor unit of split AC 2.0 toncapacity of make as existing at site single phase 230v, cooling/condensing coil assembly, electric fan motor with blower drum, control panel, front grill with nut/screws etc for fixing in wallcomplete set all as specified and as directed.
33Supply & fix in repairs of electrical water heater storage type of capacity 25 ltr, BEE 5 Star rated complete all as specified and as directed.
34Repair of voltage stabilizers, AC, single phase. upto 5 KVA of any make by opening of the body, cleaning of internally, checking and tigtening of all terminal connections including replacement of worn out terminal connectors, screws, bolts complete all as directed.
35Supply & fix in repairs of following parts ofvoltage stabilizer single phase 230V of following capacity :-
36Main transformer 5 KVA Copper wound 170 to 230V.
37Main transformer 3/4 KVA copper wound 170 V to 230 V.
38Printed circuit board (PCB) for time control/cut off for 12V system upto 10-25A suitable of 0.5 to 5 KVA stabilizer complete all as specified and as directed.
39Electromagnetic relay copper wound 12V ranging 10-25A Suitable for 0.5 to 5 KVA stabilizer complete all as specified and as directed.
40Voltmeter flush type 230V, 0-300V rangingcomplete all as specified and as directed.
41Supply & fix in repairs voltage stabilizer 5kVA230V complete all as specified and as directed. Make:- V guard/Microtek/Bluebird/Luminous
42Supply & fix in repairs of voltage stabilizer 4KVA,230V complete all as specified and as directed. Make:- V guard/Microtek/Bluebird/Luminous
43Supply & fix in repairs ofblower motor, double shaft, single/double speed, single phase, AC 230 V ofsuitable for existing window type AC 1.5/2.0 TR capacity. Make : Hitachi/Voltas/LG/Carrier/Blue star/ Daikin/Llyod/Sriram/ Panasonic etc. allas specified andas directed.
44Supply & fix in repairs of blower motor single shaft, single speed, single phase, AC, 230 V suitablefor door unit of split type AC upto 2.0 TR capacity Make : Hitachi/Voltas/LG/Carrier/Blue star/ Daikin/Llyod/Sriram/ Panasonic etc. allas specified andas directed.
45Supply & fix in repairs of blower motor single shaft, single speed, single phase, AC, 230 V suitablefor indoor unit of split type AC upto 2.0 TR capacity. Make : Hitachi/Voltas/LG/Carrier/Blue star/ Daikin/Llyod/Sriram/ Panasonic etc. allas specified andas directed.
46Supply & fix in repairs of fan motor single shaft, single phase, AC, 230 V suitableas per chiller unit of AC capacity 4.0 TRcapacity. Make : Hitachi/Voltas/LG/Carrier/Blue star/ Daikin/Llyod/Sriram/ Panasonic etc. allas specified andas directed.
47Supply & fix in repairs heavy duty PVC flexible pipe with necessary fittings for split/Window ACs of any capacity complete all as specified and as directed.
48Supply & fix in repairs front cover grill suitable for window type room AC ofmake Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/Sriram/Panasonic/ and capacity upto 2.0 TR complete all as specified and as directed.
49Supply & fix in repairs Air fillter suitable for 1.5 ton/2.0 ton capacity window type AC complete all as specified and as directed.
50Supply & fix in repairs air fillter suitable for 1.5 ton/2.0 ton splittype ACcomplete all as specified and as directed..
51Supply & fix in repairs copper tubingfor wondow/split AC of any capacity offollowing flareconforming to relevant IS.
5212mm dia
536mm dia
54Supply & fix in repairs suction/discharge valve of size 1/4"/3/8" suitable for split AC upto 2 TR capacity complete all as specified and as directed.
55Supply & fix in repairs suction/discharge valve of size 1/2"/5/8" suitable for split AC upto 2 TR capacity complete all as specified and as directed.
56Supply & fix in repairs fan blade set suitable for window AC of capacity 1.5/2.0 Tonne complete all as specified and asdirected.
57Supply & fix in repairs fan blade set suitable for split AC outdoor unit of capacity 1.5/2.0 Tonne complete all as specified and directed.
58Supply & fix in repairs remote control with PCboard (PCB) complete suitable for 1.5/2.0 tonne capacitysplit type air conditioneer suitable for make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/Panasonic model complete all as specified and asdirected..
59Supply & fix in repairs remote control with PCboard (PCB) complete suitable for 1.5/2.0 tonne capacitysplit type air conditioneer suitable for make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/Panasonic model invertertype complete all as specified and asdirected.
60Supply & fix in repairs remote control with PCboard (PCB) complete suitable for 1.5/2.0 tonne capacitysplit type air conditioneer suitable of make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/Panasonic hot and cold (inverter or non inverter type) with type complete all as specified and asdirected.
61Supply & fix in repairs remote control with PCboard (PCB) complete suitable for 1.5/2.0 tonne capacityWindow type AC suitable of make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/Panasonic type complete all as specified and asdirected..
62Supply & fix in repairs remote of split/Windowtype AC of any capacity suitable for AC"s of make Hitachi/Voltas/LG/Carrier/Blue star/Daikin/LLyod/ Sriram/Panasonic with cell complete all as specified and as directed.
63Supply & fix in repairs of outdoor unit of split AC 1.5 tonne capacity suitable for AC"s of make Hitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/ Panasonic single phase 230V complete set including rotatory compressor, fan motor, condensor unit etc complete all as specified and as directed.
64Supply & fix in repairs of outdoor unit of split AC 2.0 tonne capacity suitable for AC"s of makeHitachi/Voltas/LG/Carrier/ Blue star/Daikin/LLyod/ Sriram/ Panasonicsingle phase 230V complete set including compressor, fan motor, condensor unit etc all as specified and as directed.
65Material and labour for servicingof the following appliances which included cleaning the body, storage tank, blow out the condenser coils with air blower, alignment and greasing, cleaning of fan bushes thorough checking of wiring and rectification of defects and leakages, cleaning of blockages of drain out-let connections, testing for smooth operation in presere of Engineer-in-Charge to entire satisfaction all as specified and directed. Note :- Cost of Gas charging as in topping up as required to maintain desired gas pressure is deemed to be included in the unit rate quoted for this item.
66Water coolers ofmake Voltas/Blue star/LG/Whirlpool/Godrej/Samsung and capacity upto 280 Ltrs complete all as specified and asdirected..
67Refrigerator ofmake Voltas/Blue star/LG/Whirlpool/Godrej/Samsung and capacity upto 320 Ltrs complete all as specified and asdirected.
68Deep Freezers of make Voltas/Blue star/LG/Whirlpool/Godrej/Samsung upto 425 ltr capacity complete all as specified and asdirected.
69Testing leakage in system by injecting Nitrogen gas upto 300 PSI,rectification leaking spots/joints with gas welding work, filter anti moistoring agent, soldering, brazing, copper capillary tubing of reqd size and cleaning and flushing out complete system with gas making the system leak proof,vaccumising the complete system and supply and charging R-22/R407 refrigerant gas qty as required for the followingtype and capacity of appliances:- Note:- No extra cost shall be paid to the contractor for gas charging (any numbers of times) in case of leakage with in six months of initial gas charging except in case where external damage to the plant is noticed.
70Water coolers of capacity upto 280 Ltrs.complete all as specified and asdirected.
71Refrigerator ofcapacity upto 320 Ltrs.complete all as specified and asdirected.
72Deep Freezers upto 425 ltr capacity complete all as specified and asdirected.
73Window type AC 1.5/2.0Ton capacity complete all as specified and asdirected.
74Split type AC 1.5 /2.0 Ton capacity complete all as specified and asdirected.
75Supply & fix in repairs compressor sealed unit of the following appliances of make : Blue star/voltas/LG/ Hitachi/Carrier/Samsung/Godrej complete including replacement of copper tubing/capillary strainer etc, testing and commissioning in presence of Engineer-in-Charge to entire satisfaction all as specified and as directed.
76Water coolers of 40/80 ltr capacity. complete all as specified and asdirected.
77Water coolers of 60/120 ltr capacity. complete all as specified and asdirected.
78Refrigerator of 165-195 ltr capacity. complete all as specified and asdirected.
79Refrigerator of 300-310 ltr capacity. complete all as specified and asdirected.
80Deep Freezers upto 425 ltr capacitycomplete all as specified and asdirected.
81Supply & fix in repairs starting relay suitable for appliance of existing makes Blue star/Voltas/Hitachi/ Carrier/Samsug/Godraj of following capacity appliances:-
82Water coolers of 40/80/120 capacity. complete all as specified and asdirected.
83Refrigerator of 300 to 310 liters capacity. complete all as specified and asdirected.
84Deep freezers of upto 425 ltrs capacity. complete all as specified and asdirected.
85Supply & fix in repairs thermostats suitable for appliances of makes Blue star/Voltas/Hitachi/Carrier/ Samsug/Godraj of following capacity appliances all as directed by Engineer-in-Charge.
86Water coolers of capacity upto 280 Ltrs. complete all as specified and asdirected.
87Refrigerator ofcapacity upto 320 Ltrs. complete all as specified and asdirected.
88Deep freezers of upto 425 ltrs capacity.complete all as specified and asdirected.
89Supply & fix in repairs overload protector suitable forappliance of makes, Blue star/Voltas/Hitachi/Carrier/ Samsug/Godraj of following capacity appliances all as directed by Engineer-in-Charge.
90Water coolers of capacity upto 280 Ltrs.complete all as specified and asdirected.
91Refrigerator ofcapacity upto 320 Ltrs. complete all as specified and asdirected.
92Deep freezers of cap 425 ltrs. complete all as specified and asdirected.
93Supply & fix in repairs condenser unit of the following appliances of make Blue star/Voltas/Hitachi/Carrier/ Samsug/Godraj of following capacity appliances including making of all connections as specified and as directed by Engr-in-Charge.
94Water coolers of capacity upto 280 Ltrs complete all as specified and as directed.
95Refrigerator ofcapacity upto 320 Ltrs complete all as specified and as directed.
96Deep Freezers upto 425 ltr capacity complete all as specified and as directed.
97Supply & fix in repairs cooling coil of following appliances of make Blue star/Voltas/Hitachi/Carrier/ Samsug/Godraj of following capacity applinaces
98Water coolers of capacity upto 280 Ltrs. complete all as specified and asdirected.
99Refrigerator ofcapacity upto 320 Ltrs. complete all as specified and asdirected.
100Deep Freezers upto 425 ltr capacity complete all as specified and asdirected.
101Supply & fix in repairs float valve of water cooler of capacity upto 320 Ltrs.
102Supply & fix in repairs PVC insulated and sheathed circuler flexible 3 core 4 sqmm copper conductor cable complete all as specified and asdirected.
103Supply & fix in repairsblower/condenser fan motorwith necessary mounting bracket to and base frames for applinace of make : Blue star/Voltas/Hitachi/Carrier/ Samsug/Godraj for the following appliances complete all as specified and asdirected.
104Water coolers of capacity upto 280 Ltrs.complete all as specified and asdirected.
105Refrigerator ofcapacity upto 320 Ltrs.complete all as specified and asdirected.
106Supply & fix in repair Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in pipe including taking out existing unserviceable globe or gate of valvesof following sizes complete all as specified and asdirected.
10715mm dia bore.
10820mm dia bore.
109Supply & fix in repairspush cock ofbrass chromium platedsuitable for water cooler of any capacity including taking down existing unserviceable cock complete all as specified and as directed.
11015mm dia bore.
11120mm dia bore.
112Supply & fix in repairs of water cooler inner tank made of stainless steel of capacity (40/80 ltr) of make Blue star/Voltas/Hitachi/Carrier/ Samsug/Godrajwater cooler including drilling work with nuts and bolts complete all as specified and asdirected.
113Supply & fix in repairs water cooler inner tank made of stainless steel of capacity (60/120 ltr) complete with drilling work with nuts and bolts of make Blue star/Voltas/Hitachi/Carrier/ Samsug/Godrajwater cooler including drilling work with nuts and bolts complete all as specified and asdirected.
114Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/replacement/overhauling andre-fixing the same back to its original position or in different locations as directed by Engineer-in-charge and commissioning & testing complete all as directed. Note- (i) All major parts required for maint/ repair shall be measured and paid under relevant items mentioned as under. However, fixing charges of these items shall be deemed to be included in unit rate quoted for this item. (ii) contractor should provide suitable transportation to carry servicable/unserviceable desert cooler to site or store yard or vice vesra and cost included in the quoted rates.
115Supply only following items for incorporation in item No 51 here in before:
116Wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wirecomplete all as specified and as directed
117Cooler fan motor 230V with super enameled copper wire of existing size including testing suitable for 4000 CFM complete all as specified and as directed Make:-
118Fan blades matal suitable for motor of capacity 4000 CFM complete all as specified and as directed
1193 pin plug top one way 5 Amp, 230V.complete all as specified and as directed
120Water lifting pump 230 V, single phase, submersible type.complete all as specified and as directed
121Front show grill of desert cooler made of Stainless steel. complete all as specified and as directed
122Sidegrill of desert cooler made of stainless steel for fixing wood wool pad including iron wire mesh complete all as specified and directed.
123Flexible wire of 1.5 sqmm 3 core complete all as specified and as directed.
124Fan regulator suitable for any type any make of metal body desert cooler.
125Three way water distributer assemblyon padsalongwith connecting PVC Pipes complete all as specified and as directed.
126M & L for prepration of steel/metal body of desert cooler by scratching old pain and applying two coat of synthetic enamel paint of grey colour with spray gun/machine to achive smoothfinish and writing of MES No complete all as specified and directed by Engineer-in-charge.
127M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of standard sizewith double diversion grills and grill box suitable for 450mm sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring, fan & pump set complete controlled separately with 5 amp Piano type switch and indicator etc complete all as specified.
128Supply & fix in repairs of bottom tank of desert cooler made of MS CRC Sheet 0.8mm thick of800x700x550mm size rebated at corners nut, botls, joints sealed to make tank leak proof.complete all as specified and as directed.
129Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as directed.
130Taking down MCB distribution boards with incoming and outgoing controls any make and capacity after disconnecting of electric connections complete all as directed.
131Taking down old unserviceable/burnt sub main wiring of any size including earth wire and making good to the disturbed surfaces and removing the material from site complete all as directed.
132Material and labour for point wiring with 1.5 sq mm PVC insulated unsheathed single core multi-stranded copper conductor cable 1100 Volts grade FRLS, drawn through and including20 mm dia rigid non-metallic PVC concealed conduit (medium grade) along with 1.5 sq mm continuous PVC insulated unsheathed solid/stranded copper conductor cable FRLS for earth continuity wire, connected to earth dolly and to be terminated inflush metal boxesreadily available andconcealed type, covered withplates for mounting switch & sockets etcincluding testing on completion complete all as specified and as directed by the Engineer-in-Charge for one three / five pin switch-socket outlet, 5 Amps on independent board all as specifiedand as directed.
133All as per item No59here-in-above but for one 15 Amp 3 pin switch socket outlet, independent, with 2.5 sq mm single core multi-stranded FLRS copper conductor along with 2.5 sq mm continuous PVC insulated unsheathed FLRS solid copper conductor cable for earth continuity wire complete all as specified and as directed.
134Supply and fixing switch socket combination 2 in 1, flush type 6 Amps 240 V complete all as specified and as directed.
135Supply and fixing switch socket combination flush type 3 pin & 5 pin multipurpose 6 & 16 Amps 240 V complete all as specified and as directed.
136Material and labour for submain wiring along with earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase-Red, Neutral-Black, Earth-Green) drawn in and including concealed rigid non metallic PVC conduit medium grade, ISI marked ivory colour alongwith accessorirs of following size:
1372x4 Sqmm + 1x4Sqmm (earth) in 25 mm dia conduit.
1382x6 Sqmm + 1x6 Sqmm (earth) in 25 mm dia conduit.
1392x2.5 Sqmm + 1x2.5Sqmm (earth) in 25 mm dia conduit.
140Supply & fixing powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted for 240 volts, single pole and neutral 8 way with 100 Amps rated copper bus bar, type complete all as directed.
141Supply & fixing powder coated CRCA steel sheet MCB distrbution board, single door recess mounted for 240 volts, single pole and neutral 2 way complete all as directed.
142Supply & fixing MCB Single pole 240 volts, C series of capacity 6 to 32 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed.
143Supply & fixing MCB Single pole and neutral 240 volts, C series of capacity 32 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed.
144Supply & fixing MCB triple pole and neutral 240 volts, C series of capacity 63 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed.
145Supply & fix in repairs of electrical water heater storage type of capacity 3 ltr complete all as specified and directed.
146Material and labour rolled mild steelJoist, channel, angle or tee sections ( GDE Fe 290 ) as in framing for stand for Desert cooler, voltage stabilizer, ACs or for any other purpose with riveted bolted or welded attachment etcand inclusive of one primer coat , one under coatand one finishing coat of synthetic enamelpaint including preparation of new steel surface complete all as specified and as directed.
147Supply and fixing LT XLPE insulated heavy duty electric cables with aluminium condudctor, 1100 volts grade, 10 sqmm 2 core .complete all as specified and as directed
148Supply and fixing LT XLPE insulated heavy duty electric cables with aluminium condudctor, 1100 volts grade, 16 sqmm 4 core .complete all as specified and as directed
149Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundations laying of cable in soft /loose soil complete all as specified and as directed.
150Returning filling in including spreading, levelling, watering & well ramming in layer not exc 25cm thick complete all as specified and as directed.
151Removing excavated meterial n.exc 50m & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed
152Material and labour for fillingdry fine sand in trenchesfor cushioning to under ground cable spreading, levelling and hand punning complete all as specified and directed. Note : Punned down thickness will be measured for payment purpose.
153Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed.
154Supply & fix in repairs1/2""X1/4"" dia copper pipe including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and as directed. Note:-01 Meter of 1/2""copper pipe,01 Meter of 1/4"" dia copper pipe, 01 Meter PVC corrugated pipe shall be measured as one unit length.
155Supply & fix in repairs5/8""X3/8"" dia copper pipe includingtubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC complete all as specified and as directed. Note:-01 Meter of 5/8""internal dia ,01 Meter of 3/8"" internal dia shall be measured as one unit length.
156Supply & fix in repairs of tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split ACcomplete all as specified and as directed.
157Supply & fix in Stands for fixing of outdoor unit of split ACs complete includingnuts,bolts,clampsetc complete all as specified and as directed . Note:- working tools and plants used for fixing of outdoor unit on wall of height upto 5 mtris included in quot rates.
158Taking down ceiling fans/exhaust fans/fresh air fans of any make and type for rectifying the defects including replacement of unserviceable parts to make the fans fully functional testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes : (i).The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete will be provided without any extra cost and cost of these minor items or works will be deemed to be included in the quoted rates against this item and nothing extra shall be paid on this account
159Material and labour for spray painting to ceiling fan (1200 mm/ 1400 mm) with one coat synthetic enamel paint by spraying machine including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
160Material and labour for spray painting to exhaust fan of any make, type and size with one coat of synthetic enamel paint by spraying machine including filling cavities with filler, after cleaning all dusts including writing of MES Nos in black paint complete all as specified and as directed.
161Dismantling of worn out/burnt out windings of ceiling fan and re-winding the motor of ceiling fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing complete for following sizes of fans :
1621200 mm sweep.
1631400 mm sweep.
164Dismantling of worn out/burnt out windings of exhaust fan/fresh air fan any type/make and re-winding the motor with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish and testing complete for following sizes fans :
165150 mm sweep.
166200/230/250 mm sweep.
167300 mm sweep.
168375 mm sweep.
169450 mm sweep.
170Supply only capacitors 2.5 MFD suitable for all types of fans complete all as specified and as directed. Make: - Usha/Universal/ Epcos.
171Supply only capacitors 4.0 MFD suitable for all types of exhaust fans complete all as specified and as directed. Make: - Usha/ Universal/ Epcos.
172Supply only ball bearing suitable for ceiling fan/exhaust fan/fresh air fan of any type as per existing required including proper alignment of shaft and testing complete all as specified and as directed.
173Supply only bush made out of Gun metal suitable for ceiling fan/exhaust fan/fresh air fan as required at site complete all as specified and as directed.
174Supply only shaft of approved quality as per existing for ceiling fan/ exhaust fan/fresh air fan any make as required at site complete all as specified and as directed.
175Supply only canopy (set of two) suitable for ceiling fans of any make, type and size complete all as directed.
176Supply only down rod MS grade 15 mm bore of length upto 90 cm suitable for ceiling fans of any type and size including cutting, drilling holes, making thread and painting complete all as directed.
177Supply only exhaust fan blade of type and make as existing or as directed at site complete all as specified and as directed.
178Supply only ceiling fan blade of type and make as existing or as directed at following sweep fan complete all as directed
1791200 mm sweep.
1801400 mm sweep.
181Supply only MS louvers with nuts, bolts and washers suitable for exhaust fan upto 350 mm sweep of any description/make/model complete all as specified and as directed by Engr-in-Charge.
182All as per Srl Item No 96 here-in-before above but for 450 mm Sweep exhaust fan.
183Supply only suitable frames of 300/375/450 mm sweep exhaust fan of any description/make/model complete all as specified and as directed at site.
184Supply only exhaust fan motor 18"" copper winding, 1450 rpm, 230V , 50 Hz ,with fixing accessories to mount on frame complete all as specified and as directed.
185Supply only exhaust fan motor 12"" copper winding,230V , 50 Hz ,with fixing accessories to mount on frame complete all as specified and as directed.
186Supply only exhaust fan motor suitable for 8"" to 10"" PVC ventilator/ fresh air fan, copper winding, 230V, 50 Hz , with fixing accessories to mount on frame complete all as specified and as directed.
187Supply and fix in repair wall mounted fan motor, copper winding, 230V, 50 Hz , with fixing accessories to mount on frame complete all as directed icluding taking down old unserviceable fan motor from exitsting fan complete all as specified and as directed.
188Supply and fix in repair wall mounted fan blade of any type and make as existing or as directed at site icluding taking down old unserviceable fan blade from exitsting fan complete all as specified and as directed.
189Supply and fixing in replacement of fresh air/ventilator fan made of sturdy engineering plastic with built in louvers, AC, 230Volt single phase, 50 Hz, incl depositing the old one in MES store yard complete all as specified and directed of following sizes :-
190150mm Sweep
191200mm Sweep
192250mm Sweep
193Taking down carefully Submain wiring of any type/size complete and making good disturbed sufaces to match with the existing surfaces complete all as specified and directed.
194M & L for Sub Main Wiring with two runs single core 10 Sqmm PVC insulated unsheathed(FRLS) cable with multistranded, 1100 volts grade copper conductor drawn in suitable size of rigid non-metallic PVC conduit (not less then 25mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) with and including 10 Sqmm copper green colour earth wire complete all as specified and directed. Note: Two runs 10 Sq mm (P&N),one run of 10 Sq mmearth wire & One run ofPVC conduitwill measured as one RM.
195M & L for 3 core copper conductor 0.75 sqmm conductor area, PVC insulated, PVC round sheathed multicore, 1100 volt,including with use of PVC conduit pipe / Casing -Caping as per site requirement including taking down old u/s wire complete all as specified and as directed.
196M & L for 3 core copper conductor 2.5 sqmm conductor area, PVC insulated, PVC round sheathed multicore, 1100 volt,including with use of PVC conduit pipe / Casing -Caping as per site requirement including taking down old u/s wire complete all as specified and as directed.
197Supply and fixing in replacement of ceiling fan AC 230 Volt single phase five star rating and fixing accessories complete of 1200 mm sweep incl depositing the old one in MES store yard complete all as specified and as directed.
198Supply and fix in repair fan Regulator electronic step type, piano flush type as per existing type (switch or socket type) on the existing phenolic laminated sheet including taking down the old unserviceablecomplete all as specified and as directed.
199Supply and fix in repair step type electronic modular type fan regulator 1M on theexisting plate including taking down the old unserviceable complete all as specified and as directed.
200Supply and fix in repair step type electronic modular type fan regulator 2M on theexisting plate including taking down the old unserviceable complete all as specified and as directed.
201M & L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, 1100 volts grade copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall/roof incl cutting & chases( making good all to the disturbed surfaces as per existing) including with flush metal boxes with cover plates & frame for mounting switches, sockets, regulators etc or including sunk cast iron /pressed steel/terminal boxed for mounting flush typeswitches/sockets etc with 3 mm thick phenolic laminated sheet covers and including earth wire ofPVC insulated (FRLS) copper conductor multistrandedof 1.5Sqmmsize in green colourcompletefor one light point/ bell point/ completed by one way switch/push button all as specified and as directed.
202All as per item 113 above but for one three / five pin switch-socket outlet, 5 Amps on same board all as specifiedand as directed
203All as per item No. 113 butfor 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent Point wiring complete all as specified and as directed .
204Supply and Fixing in repair Modular switch 6 Amps single pole one-way, 1 Module complete as per existing, as specified and directed by Engr- in- Charge.
205Supply and Fixing in repair Modularsocket2-in-1, 5 pins 6 Amps , combined 2 Modulecomplete as per existing, as specified and directed by Engr- in- Charge.
206Supply and Fixing in repair Modular switch16 Amp single pole one way,1 Module all as specified. Make: Cat part No AHFSXXW161 of havells or equivalent.
207Supply and Fixingin repair Modular socket 2-in-1,3 and5 pins 6 /16 Amps, combined 2 Module complete all as specified.
208Supply and fix in repair step type electronic fan regulator modular type 1M complete all as specified and as directed.
209Supply and Fix Modular bell Push switch 6 Amps with indicator single pole one-way, 1 Module complete as per existing complete all as specified and as directed.
210Supply and Fixing ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
211Supply and fixing switch piano fiush button, single pole one way 5 amps complete all as specified and as directed.
212S&F in repair switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
213S&F in repair socket out let 2 in 1 flush type 3 pin 5 & 15 Amp complete all as specified and as directed.
214S&F in repair socket out let 2 in 1 flush type 5 pin 5 Amp complete all as specified and as directed.
215S&F in replacement MCB distribution board, SPN 2 Way, single door, sheet steel, phosphatised, powder painted, 240 V, complete all as specified and as directed.
216Supply and fix in replacement SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Voltswith all connection complete all as specified and as directed. Make : Havells/Legrand /L&T/ C&S
217Supply and fix in repairs Bell Ding dong type,230 Volts and connection complete all as specified and as directed.
218S&F in repairs LED post top lantern with spun aluminium canopy,light fitting 30W IP-65 rated, symettric light distribution with clear acrylic diffuser including driver complete with all fixing accessories complete all as specified and as directed.
219Supply & fixing in replacement indoor decorative ultra slim surface/wall mounted T5 LED batten tube light with 1x20 watt tube light fitting complete fitting with polycarbonate channel housing & integrated electronic driver, energy efficient, 14V-270 volts complete with all accessories internally/pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete.
220Supply & fix in replacement surface mounted bulk head LED light fitting including 10 watt LED lamp B22 base complete with all accessories and connection complete all as specified and as directed.
221Supply & fix in repair recess type, 36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- relatedcolour temperature (CCT) of 6500K, warm white/ cool white/natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge.
222Supply & fixing in repair indoor wall mounted fitting, brushed nickel finish fixture, mild steel with glass finish with opal glass diffuser, with LED retrofit bulb of capacity 09 watts all as directed at site. Make:-Havells Cat Part No. FLORETINE WL 1LS B22 SS or equivalent make in Crompton/ Philips C&S.
223Supply and fixing in replacement of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainablewith heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of = 70 and co- relatedcolour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF= 0.9 and total harmonic distortion of THD = 10%, voltage range of 140-280Vincluding all connections complete all as specified.
224S&F in repairs LED extruded aluminium decorative & cylindrical shape bollard light 10 W with integrated driver, IP 65, with uniform light distribution complete all as specified and as directed.
225S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted withbus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified.
226Supply and lay GI tubing, light grade, 50 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete including dismantling corroded GI pipe complete all as specified and as directed.
227Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 4 core, laid in trenches/duct/fixing on walls/poles including connecting with suitable lugs, glands, nuts and bolts in existing Panelfrom pole/Main Panel Box and testing complete all as specified and as directed.
Disclaimer :