Repair Maint Of Ceiling Exhaust Ventiln Fans Lighteng Protecton Sys Bldg Earthing Storage Water Heater Desert Cooler And Allied Works At Dhangu Military Comp Area Under Ge S Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Repair Maint Of Ceiling Exhaust Ventiln Fans Lighteng Protecton Sys Bldg Earthing Storage Water Heater Desert Cooler And Allied Works At Dhangu Military Comp Area Under Ge S Pathankot. Submission Date for this Tender is 23-08-2022. Electrification Work Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

33237414
Corrigendum : Repair Maint Of Ceiling Exhaust Ventiln Fans Lighteng Protecton Sys Bldg Earthing Storage Water Heater Desert Cooler And Allied Works At Dhangu Military Comp Area Under Ge S Pathankot
Open Tender
Indian
Punjab
pathankot
23-08-2022

Tender Details

Repair Maint Of Ceiling Exhaust Ventiln Fans Lighteng Protecton Sys Bldg Earthing Storage Water Heater Desert Cooler And Allied Works At Dhangu Military Comp Area Under Ge S Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Aug-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-08-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 62000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN REPAIR/ MAINT OF CEILING FANS/ EXHAUST FANS/ VENTILATION FANS, LIGHTENING PROTECTION SYSTEM, BLDG EARTHING STORAGE WATER HEATER, DESERT COOLER AND ALLIED WORKS AT DHANGU MILITARY COMPLEX AREA UNDER GE(SOUTH) PATHANKOT.
Sl. No. Item Description
1Dismantling and taking out burnt winding by cutting, cleaningslots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii)Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
2Dismantling and taking out burnt winding by cutting, cleaningslots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii)Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
3Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
4Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfdISI marked complete all as spd.
5All as per Srl item No. 4 above but 3.15mfd complete all as spd.
6Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
7Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
8Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
9Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
10S & F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
11S & F PVC Two way connector for ceiling fan complete all as specified and directed.
12Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/ site requirement/ Make of fan complete all as spd.
13Servicing of ceiling fans of capacity 1200/ 1400mm including taking down from site, dismantling, cleaning, greasing/ oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
14Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
15Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii)Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
16All as per Srl item 15 above but 350mm-450mm sweep complete all as spd and directed..
17Dismantling of wall/pedestal fan of any sweep, repair the same by cleaning, overhauling, necessary lathe work (grinding & polishing) etc and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desiredRPM including necessary insulating materials, insulating varnishing, cleaning and reassembling the wall/pedestal fanafter replacement of unserviceable minor parts such as frame nut, knob, regulator switch clamp of cendenser etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etcand testing complete on completion and re-fixing the fan in existing positionincluding provn of twin twisted flexible copper stranded conductor wire of size 23/ 0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop form MES store yard)
18S & F louver, suitable for exhaust fan of any make and size upto 300-350 mm, fixed in repair complete all as specified and as directed.
19All as per item 18 above but of size 400 mm-450 mm
20Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
21Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/ wall mounting fan/ Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
22S&F in repair ceiling fans 1200 mm Sweep Ceiling Fan, Energy Saving, BLDC Motor without romote complete with canopy, blades, down rod, split pin etc complete of approx wattage 30 to 32 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
23S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 200 to 250 mm sweep PVC body with louvreincluding connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
24S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvreincluding connecting to ceiling roseand dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
25S&F Exhaust fan AC sinlge phase 230/240 volts of size 450 mm sweep steel body with louvreincluding connecting to ceiling roseand dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
26S&F in repair wall mounted fan 400 mm Sweep Energy Saving, copper wounded Motor, three speed control completesuitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
27M & L for attending routine complaints for fan including retificaiton of minor defects by taking down the existing ceiling/wall mounted/exhaust fan of any size repairing and refixing after changing of defects/unserviceable parts such as changing of capacitors, changing of fan regulators, bypin holdets, shakle assy,fixing of loose connection ect complete all as specifed and directed by Engr-in-Charge. (Note replacement of defect parts such as fan regulator, bipin holder, capacitors, shakel assy atc shall be measured and paid separately under relevant item. Electrician should collect compalint slip on daily basis at 9"O clock fromcomplaint section and resubmit it after rectification at the complaint cell. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch "A" . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Dhangu complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi)Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
28M & L for attending routine complaints for geyser including retificaiton of minor defects by taking down the existing geyser of any size repairing and refixing after changing of defects/unserviceable parts such as changing of syphon assembly, element, thermostat, indicators, PVC connection, fixing of loose connection etc complete all as specifed and directed by Engr-in-Charge. (Note replacement of defect parts such as syphon assembly, element, thermostat, indicators, PVC connection, etc shall be measured and paid separately under relevant item. Electrician should collect compalint slip on daily basis at 9"O clock fromcomplaint section and resubmit it after rectification at the complaint cell. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch "A" . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Dhangu complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi)Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
29Disconnecting the inlet/ outlet water connections and electric connections of Storagestorage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
30Supply only internal SS tank of storage type electric water heater of 25 ltr capacity complete with syphon assembly, 1.5 KW/2.0 KW element, rubber gasket , thermostat switch, all as specified and directedfor carrying out repairs under relevant item No.29 . Note :- The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor .Tank with stud type roundelement shall only be used . (Triangular element shall not be allowed .)
31Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directedfor carrying out repairs under relevant item No.29.
32Supply only thermostat switch ISI marked forstorage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius)for carrying out repairs under relevant item No.29
33Supply only cup/triangulartypestorage type electric water heater element AC 230 volt, of rating 1500/2000 wattfor carrying out repairs under relevant item No.29.
34Supply only outer body suitable for 25ltrstorage type electric water heater made out of MS sheet factory made complete with fixing bracket matching with existingcomplete all as specified and directedfor carrying out repairs under relevant item No.29.
35Supply only glass woolof 25ltrs capacitystorage type electric water heatercomplete all as specified anddirected for carrying out repairs under relevant item No.29.
36Supply only indicator lamp square/roundtype suitable forstorage type electric water heater 25 ltr all as per sample AC 230 Voltfor carrying out repairs under relevant item No.29.
37Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
38S&F sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
39De-scaling ofstorage type electric water heater of capacity 25 ltr after taking down thestorage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation ofstorage type electric water heater complete all as directed by Engineer-in –Charge.
40S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
41Replacement of spring loaded air release valve ISI marked suitable for 25ltrs capacitystorage type electric water heaters.
42Replacement of safety valve/ dead wt. valve ISI marked suitable for 25 Ltrs capacity storage type electric water heaters.
43Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
44Supply and fix gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
45S&F anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
46Preparing the old surface by rubbing/scratching the old paint and providing the one coats of synthetic enameled paint through spray paining of 25 ltrstorage type electric water heater.
47Supply and replace brass non return valve suitable for 25 ltrstorage type electric water heater of size 15 mm.
48Supply and replace bottom cover plate ofstorage type electric water heater of capacity 25 ltr complete with MS screw all as per sample.
49Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
50Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
51S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upup 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
52Replacement of heating element2/3 KW suitable for stand by back up supply to solar water heater.
53M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
54Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning ofstorage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.(Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
55Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning ofstorage type electric water heater of 50 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed. (Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
56Disconnecting the water connections and electric connections of Desert coolers of capacity 3000 CFM to 5000CFM, taking down carefully from stand/ CC supports ,checking the outer body for any damage and strip opening the same carefully for thorough inspection of serviceablity/ functionality of parts such as fan assembly with motor (blower assly),water pump, khas khas pad , control wiring , selector switch etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after.(b) Any other minor spares such as nut bolts, screws,piano switch, indication lamp replacement required is deemed to beincluded in quoted rate.
57Supply only wiring for desert cooler including all accessories all complete diected for carrying out repairs under relevant item.
58Supply only blower motor ofsingle way shaft 240 Volts 50 c/s of suitable capacityfor desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item.
59Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item.
60Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item.
61Removing the old paintfromthe body ofdesert cooler making the body dust proof and preparing the surface and painting the desert cooler with one coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
62Removing the old rusted base tub of desert cooler of 3000 to 5000 cfm capacityand fabrication of base tray and top cover made of PGI sheet of minimum0.8 mm thick sheetand fixing in position using necessary nuts, bolts and washers all as specified and directed.
63S&F in replacement of existing UNSV galvanized iron top coverofminimum0.8 mm thick sheetper and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
64S&F in replacement of existing UNSV galvanized iron side pillar of minimum 0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge
65S&F in replacement of existing UNSV galvanized iron side shutter of minimum0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed by Engr-in-Charge.
66M&L in replacement of existing UNSVPVC front show grill complete with selector switch piano type switch and indicator etc as per requirement for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed.
67M&L in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/Forged steel suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
68M&L in replacement of Leg set complete for fixing blower motor for desert cooler complete with all necessary fixing/Fastening arrangements(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
69M&L in replacement ofwater distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece)(As per sample) suitable for 3000 to 5000 cfm capacityDesert Cooler complete all as specified and directed
70M&L in replacement of Capacitor of capacity 4mfd suitable for desert coolercomplete all as specified and directed
71Dismantling old defective desert cooler and depositing to MES store yard. Supply, install, test and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimumair Delivery- ?4000 Cum/hr,approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPMrated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch withfan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including standof minimum height 900 mm made out 25mmx25mmx3mm MS angle iron , duly coated with weather proof paint of black colour
72Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level) with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with galvanizediron GI earth wire 4mm dia by means ofbolt nut check nuts and washersof galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
73Material and labour earthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
74Material and labour earthing with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to20×3mm copper strip as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified orindicatedincludingtesting on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe,Copper earth strip upto 7.5 m long for connecting totest point etc. all as required at site for complete earthing) and dismantling old defective earthpit.
75M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mmincluding dismantling old one.
76M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wireincluding dismantling old one.
77M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with 20x3mm copper strip including dismantling old one.
78Supply and lay 40 mm dia bore GI tubes light grade galvanised with all fittings laid in trenches etc for protection of cable.
79Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
80S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/ down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
81S&F in repair Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
82M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with GI strip 32x6mm including dismantling old one.
83M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated location for loop earthing etc. with 20x3mm copper strip including dismantling old one.
84S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipemedium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
85S&F in repair air termination single pointed copper rod 12mm dia 12mm dia and 300 mm long for fixing on GI pipemedium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
86M&L for plain Cement concrete 1:2:4 typeB-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified.
87Supply & Fixingin repair GI pipe medium grade 40 mm dia for fixing Aluminium strip 25x3.15 mm on roof for lightening protection duly drilling 2 Nos holes on Aluminum strip and GI pipe on one end and fixing with screws/suitable size of bolts & nuts complete all as specified. Note: GI Strip required will measured and paid separately.
88Supply and fixing in repair Test point terminal block made aluminum strip 25 x 3.15 mm of size 75x75 drilled and screwed on insulators compleete all as specified and directed.
89supply and fixing in repairPorcelain insulators fixied with two number of nuts and fixing of down/roof conductors including taking down of old ones complete all as specified and directed by Engr-In-Charge
90Supply and fixing plug top polycarbonate 3 pin, 5Amp all as specified and directed by Engr-in-Charge
91Suppy and fixing PVC insulated and PVC sheathed 3 Core copper conductor flexible round cable of 02 Sq mm all as specified and directed by Engr-in-charge
92Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB"S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
93M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduitheavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portionsurface conduit wiringshall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
94All as per srl item 93 above but for one light point controlled by 2 nos two way switches.
95All as per srl item93 above but for one 3 pin 5A socket outlet independent board.
96All as per srl item 93 above but for one 5A socket outlet on the same board
97All as per srl item 93 above but for one 5A socket outlet below the board.
98All as per srl item No 93 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
99M & L for replacement of existing un-serviceable switch with switch piano polycarbonate bodyflush button single pole two way 5 amps, 230 volts.
100M & L for replacement of existing un-serviceable switch with switch piano polycarbonate bodyflush button single pole two way 15 amps, 230 volts.
101M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts.
102M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type all as specified and directed.
103M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type all as specified and directed.
104M & L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
105M & L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
106M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
107M and L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed
108M & L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
109S & F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed.
110M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduitheavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portionsurface conduit wiringshall be carried out.) Note: The quoted rate inclusive for the following :- (a) Modular inner and outer frame plate shall be included in quoted rates (b) Proper colour coding is to be followed as per IS Specification. (c) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(d) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(e) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
111All as per srl item 110 above but for one 3 pin module socket out let 5/6 Amps on same board.
112All as per srl item 110 above but for one module socket out let 5/6 Amps on Independent board.
113All as per srl item 110 above but for one module socket out let 5/6 Amps on below the board.
114All as per srl item 110 above but for 15/16 Amps socket out let independent with 4 sqmm copper conductor and.
115M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
116M & L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
117M & L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
118M & L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
119M & L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
120M & L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
121M & L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed complete all as spd and directed.
122M & L for replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
123M & L for replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
124Supply and fix in replacement existing UNSV Recess/ suspended slim LED panel light with powder coated rim 36 watt of size 2x2 feet high efficiency designer recessed mirror optic luminary with ceiling cut out size 36 watt including LED lamps completeincluding connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required and specified by Engr-in-Charge.
125M & L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18/20 watt energy efficient tube light fittings LEDcomplete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
126Supply and fixing LED Bulk head light fitting 1 X 13.5watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
127M & L for replacement of existing old u/s mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
128S&F LED Lamp 230 volts,50 Hz,inverter LED 10 watt ,lumen 900 lm,Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius, back time 04 Hours, complete all as specififed and direccted.
129M & L for replacement LED lamp 7 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
130M & L for replacementLED lamp 15 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
131M & L for replacementLED lamp 12 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
132Supply & Fix in replacement sheet metal enclosure 4 way , with SPN DB"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
133Supply & Fix in replacement sheet metal enclosure 8 way, with SPN DB"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
134Supply & Fix in replacement sheet metal enclosure 12 way, with SPN DB"s ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
135Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
136S & F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection, cemet spill prptector suitablefor MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
137M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three polecomplete all as specified and directed.including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
138Supply and fix in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
139Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 25 watt, complete using bracket of suitable size fixed on wall with clamps, including making connection with 03 core copper cable of size 1.5 Sq mm all as specifed and directed by Engr-in-Charge.
140Supply and fix in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
141Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge.(Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch "A" . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Dhangu complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi)Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
142Supply and fixing socket outlet Polycarbonate body 2 in 1, 3 pin 15 Amp flush type all as specified and directed.
143Supply and fixingsocket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
144Supply & fixing in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge
145Supply & fixing in repair ofpressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed by Engr-in-charge
146Supply and fixing in repair ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
147Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm , cut to size all as required at site.
148Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm , cut to size all as required at site.
149Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 4.0 sqmm , cut to size all as required at site.
150Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 6.0 sqmm , cut to size all as required at site.
151Supplying and fixingin replacement of old u/s service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wirecomplete all as spd and directed.
152All as per srl item No.151 above but for service cable of size 10 sqmm,complete all as spd and directed.
153All as per srl item No.151above but for service cable of size 16 sqmm,complete all as spd and directed.
154Supply and fixing AC single phase 10-60A Net Meter DLMS compiance of accuracy class 1.0, 240V 50 Hz, with backlit LCD, Optical port (measures Import KWh, Export kWh, net kWh, V,I,kW, 6 month history of Energy), with Rs232 Port including dismatling of existing meter and deposting it yto MES store Yard, making all necessary input and output connection of the new energy meter. Complete ass as specified by Engr-in-charge.
155Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.