Repair And Maintenance To Windows/Split Acs, Water Coolers,Refrigerators, Deep Freezers And Misc Connected Works At 20 Wing Afs Bagdogra Under Ge (Af) Bagdogra, bagdogra-West Bengal

Military Engineer Services-MES has published Repair And Maintenance To Windows/Split Acs, Water Coolers,Refrigerators, Deep Freezers And Misc Connected Works At 20 Wing Afs Bagdogra Under Ge (Af) Bagdogra. Submission Date for this Tender is 10-08-2022. Freezer Tenders in bagdogra West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

33166666
Repair And Maintenance To Windows/Split Acs, Water Coolers,Refrigerators, Deep Freezers And Misc Connected Works At 20 Wing Afs Bagdogra Under Ge (Af) Bagdogra
Open Tender
Indian
West Bengal
bagdogra
10-08-2022

Tender Details

Repair And Maintenance To Windows/Split Acs, Water Coolers,Refrigerators, Deep Freezers And Misc Connected Works At 20 Wing Afs Bagdogra Under Ge (Af) Bagdogra

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work : Repair and maintenance to windows/split ACs, water coolers,refrigerators, deep freezers & Misc connected works at 20 Wing AFS Bagdogra under GE (AF) Bagdogra.
Sl. No. Item Description
1Disconnecting the electric connection and taking out window type AC 1.5TR/2TR capacity from wall, overhauling and servicing the window type AC by help of Blower gun, Soap water etc, oiling greasing as required and painting the AC including outer cover after work refixng in original position and reconnecting the electric connection and making serviceable and recharging the refrigerant gas, if required. Note:- Extra refrigerant gas if required will be measured & paid separately as supply only.
2All as item No 01 above, but split type AC of 1.5/2TR capacity.
3Attending the complaints as directed by the Engineer-in Charge for carrying any nature defects complete of Window type AC , Split, Mega split, Ductable Split AC, Water cooler, Refrigerator and Deep freeze , all as directed. Note:- (i) Supplying of new accessories/components required for the system shall be measured & paid separately as supply only. (ii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge if serviceable. (iii) Completion of job will be considered only after complete rectification of defect upto satisfaction ofEngineer -in - Charge. (iv) Complaint shall be attended on the same day of obtaining complaints & intimate to JE incharge by evening. (v) Rate for necessary stationary for complaint register & complaint slips shall be deemed to include in quoted rate.
4Dismantling of defective Window type AC/ Split typeAir conditioner indoor/outdoor unit of any make of 1.5TR capacity for thorough checking / repair of all accessories and components and reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed by Engineer – In – Charge including transportation to workshop and back. Note : (i) Supplying of new accessories/components required for the system shall be measured & paid separately here-in-after as supply only. (ii) Replacement of sealed compressor unit, painting etc shall be measured and paid separately as supply only. (iii) Old serviceable accessories / components obtained from dismantling shall be refixed as directed by Engineer -in - Charge and labour charges for refixing shall be deemed to be included in the unit of item rate.
5All as per item No 5 above, but for AC of 2.0 TR capacity.
6S&F compressor rotary energy efficient/ reciprocal in replacement of old compressor having any No of cuts of same size , capacity and connecting with existing system testing to leakage including recharging of refrigerant gas after installation sealed unit with the split type AC of 1.5 TRcapacity commissioning complete all as specified and directed. (Make- Hitachi/ Bluestar/Carrier/ LG). (Note:- unserviceable compressor shall be the property of contractor)
7All as per item No 6 above, but for 2.0 TR capacity.
8Supply only aluminium fan blade each suitable for outdoor unit of 1.5 TR (Split) capacity forsplit /megaductable split type AC.
9All as per item No 8 above, but for 2 TR capacity.
10Supply only capacitor of 2.5 MFD capacity. (Make- Sarda/ Universal/Usha)
11Supply only capacitor of 4 MFD capacity.
12Supply only capacitor of 8 MFD capacity.
13Supply only capacitor of 10 MFD capacity.
14Supply only refrigerant gas R-32 Afor charging of 1.5 TR to 11.6 TR capacity split, mega split and ductable split type AC.
15Supply only running dual capacitor of 36+6 MFD capacity. (Make- Sarda/ Universal/Usha)
16Supply only running dual capacitor of 40+6 MFD capacity.
17Supply only running dual capacitor of 45+6 MFD capacity.
18Supply only running dual capacitor of 50+6 MFD capacity.
19Supply only running dual capacitor of 60+6 MFD capacity.
20Supply only three Pole power contactor of 9 Amps capacity. (Make- Havells/ Legrand/ Seimens/ L&T)
21Supply only three Pole power contactor of 25 Amps capacity.
22Supply only three Pole power contactor of 32 Amps capacity.
23Supply only three Pole power contactor of 40 Amps capacity.
24Taking out unserviceable blower motor from existing location of 1.5 TR capacityof Split AC, Window AC,mega split/ductable outdoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement ofunserviceable 2 nos. bearing of existingsize and reassembling the blower motor and fixed complete all as directed by Engr -in - Charge. (Note:- Unserviceable winding wire shall be handedover to store and necessary RV shall be obtained.)
25All as per item No 24 above, but 2.0 TR capacity.
26Taking out unserviceable blower motor from existing location of 1.5 TR capacity of Split AC, Window AC, Mega Split AC, Ductable AC Indoor unit & dismantling the blower motor, cutting/removing burnt copper wire and rewinding the same of existing gauge by super enamelled copper wire, varnishing heating and testing including replacement ofunserviceable 2 nos. bearing and reassembling the blower motor and fixed complete all as directed by Engr -in - Charge. (Note:- Unserviceable winding wire shall be handedover to store and necessary RV shall be obtained.)
27All as per item No 26 above, but 2.0 TR capacity.
28Dismantling unserviceable remote control assembly and replacing unserviceable items such as IC, PCB, Transformer and magnetic coil suitable for indoor 1.5 TR capcity split/ window type AC and reassembling the same after testing complete.
29All as per item No 28 above, but 2.0 TR capacity.
30Dismantling the condensing coil and supply and fix the new condensing coil made of copper pipe for 1.5 TR Capacity Split AC/ Window type AC.
31All as per item No 30 above, butfor 2.0 TR capacity Split AC/ Window type AC.
32M&L for detecting leakage of Air conditioning system rectifying the leakage and testing complete all as specified and directed by Engr -in Charge of 1.5 TR capacity split/window type AC.
33All as per item No 32 above, butfor 2.0 TR capacity.
34S&F suction/Discharge valve including taking down unserviceable one. (Make B/M/KEM/ Castle) (a)1 1/8"
35All as per item No 34 above, butfor 5/8" each.
36All as per item No 34 above, butfor 1/2" each.
37All as per item No 34 above, but for 3/8" each
38All as per item No 34 above, butfor 1/4" each.
39Supply only refrigerant gas R-22for charging of 1.5 TR to 11.6 TR capacity split, mega split and ductable split type AC.
40Supply only refrigerant gas R-410a for charging of 1.5 TR to 11.6 TR capacity mega and ductable split type and VRF typr Air Conditioner
41Supply only refrigerant gas R-134Afor charging of water cooler and refrigerators.
42Dismantling of window type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including brick work, plaster and making good by painting with existing color at old and new location complete all as specified and as directed.
43Dismantling of Split type Air conditioner of any make 1.5/2 TR capacity and refixing in new location including necessary civil work complete all as specified and as directed.
44S&F single core PVC insulated cable with stranded copper conductor 1100 Volt grade of following size (nominal area) for sub main wiring and drawing in to and including PVC casing capping 20mm wide with all fittings including of following size PVC insulated stranded copper conductor cable earth continuity conductor complete including taking down unserviceable cable. (a) 2x 4sqmmsubmain wiringwith 1x4 sqmm.
45All as per item No 44 above, butfor 2x 6sqmmsubmain wiringwith 1x 6 sqmm.
46All as per item No 44 above, butfor 4 x 10 sqmm submain wiringwith 2x 10 sqmm.
47S&F Copper rifrigerant pipe of size 3/8”.
48S&F Copper rifrigerant pipe of size 1/4”
49S&F Copper rifrigerant pipe of size 1/2”
50S&F Copper rifrigerant pipe of size 5/8 “
51S &FInsulation for cooling line all as directed by Engr-in-Charge.
52Supply only starting relay for 1.5 TR/ 2 TR capacity of window / split type AC. (Make- Sriram/Annapurna/ Hi-teck)
53S&FSheet metal enclosure for SP, with two pin earth plug and socket complete with one SP,MCB 20Amps including taking down.
54Dismantling the unserviceable 15mm drain PVC water pipe and supplying and fixing including provision of saddles/ clamps upto 100 mm above the ground level all as directed.
55Supply only Air filter of suitable size for Split AC 1.5 TR.
56All as per item No 55 above, but for Split AC 2.0 TR.
57Supply only Air filter for WindowAC 1.5/2.0 TR.
58WATER COOLER Servicing towater cooler capacity 40/80, 60/120 & 150 ltrs for thorough checking including all accessories and components replacement of defective accessories/ components & testing complete all as specified and as directed. Note: (a) New accessories/ components required shall be measured and paid separately as supply only. Labour charges for fixing are deemed to be included in the unit quoted rate. (b) Repair, overhauling, rewinding motor, replacement of sealed compressor unit re- charging of compressor oil and refrigerant gas etc shall be measured and paid separately. (c) old serviceable accessories / components removed shall be refixed as directed by Engr - in charge rate for fixing shall be deemed to be included in the unit rate of item above.
59Supply onlywater cooler aluminium fan blade for capacity 40/80 Ltrs.
60Supply only aluminium fan blade for capacity 120 & 150 Ltrs water coolers.
61Supply only wiring set complete of PVC insulated cable stranded copper conductor connecting clip etc suitable for any capacity of water cooler.
62Supply only thermostate with plastic regulator knob for water coolers.
63Supply only relay switch for water cooler suitable for (As per sample) any capacity of water cooler. MODEL – 412/ 412Y.
64Supply only over load protector type 1022 for any capacity of water cooler.
65Supply only self closing chromium plated brass bib tap/ push tap 15mm dia suitable for any type / capacity of water cooler.
66Supply only 15 mm dia Float valve synthetic metal alongwith PVC ball and AI connecting rod complete with all accessories.
67Supply only running capacitor 25 Mfd 415 Volts AC, 50 Hz..
68Supply only starting capacitor 80-100 Mfd 415 Volts AC, 50 Hz.
69Cutting out rusted / perforated portion of body from water cooler of any size including fixing 18 SWG thick MS sheet in cut out portion by gas welding, screwing etc where necessary complete all as directed including two coats of synthetic enamel painting over one coat of red oxide primer to the welded portion of approved brand complete all as directed.
70S&F compressor rotary energy efficient /reciprocal for water cooler and connecting with existing system testing for leakage includingre – charging of refrigerant gas after installation sealed unit with the water cooler of 40/80 litres capacity commissioning including dismantling unserviceable one complete all as specified and directed Note:- Refilling ofR-134a gas shall be measured & paid separately as supply only.
71All as per item No 70 above, but 60/120 litres.
72All as per item No 70 above, but150 litres.
73Recharging of refrigerant gas R-134aafter vacuuming dehydration leak testing for the system as per standard practice and rectifying / arresting the same by brazing to copper tubing for proper cooling and satisfactory performance complete all as specified and as directed for water cooler of 40/80 ltr/hrs capacity. Note:- Supply only for Gas R-134a shall be measursd & paid separately.
74All as per item No 73 above, but 60/120 Ltr/hrs.
75All as per item No 73 above, but 150 Ltr/hrs
76Opening blower motor of any type / make cutting removing of the worn out copper wire cleaning the armature, rewinding the same with existing size of super enamel, copper wire including necessary insulating tubes and replacement of bush and testing complete for 40/80 litres. Note:- Unserviceable cooper winding wire shall be returned to store and necessary RV obtained.
77All as per item No 76 above, but 60/120 Ltr/hrs.
78All as per item No 76 above, but 150 litres.
79Scrapping out old damaged paints rusts etc form Water coolerbody cleaning the body with soap water providing putty where necessary & applying two coats of ASPA, high glossy paint of approved colour over a coat of metal primer complete all as specified and as directed for 40/80 litres.
80All as per item No 79 above, but 120/150 litres.
81REFRIGERATOR Dismantling of defective refrigerator of any make and any type capacity for through checking of all accessories and components, repair & reassembling the same after repair/ replacement of defective accessories / components and testing complete all as directed. Note : (a) New accessories / components required shall be measured and paid separately as supply only labour charges for fixing shall be included in the unit rate. (b) Replacement of sealed compressor unit Gas charging painting etc. shall be measured and paid separately. (c) Old serviceable accessories / components obtained after dismantlingshall be refixed as directed and labour charges for refixing shall be deemed to be included in the unit rate.
82Supply only Cooling coil chamber including cooling coil of refrigerator 175/210Ltrs.
83All as per item No 81 above, but for 280/335 Ltr.
84Supply only thermostat defrost type including plastic regulating knob.
85Supply only relay switch.
86Supply only lamp screwed / pin type including 15 Watts lamp 220 Volts.
87Supply only timer.
88Supply only bimetal relay.
89Supply only condenser coil.
90S&F compressor rotary energy efficient/reciprocal for Refrigerator of 175-210 litres capacity of original manufacturer and connecting with existing system testing to leakage including recharging of refrigerant Gas after installing sealed unit to refrigerator of 175-210 litres capacitycommissioning including dismantling unserviceable one complete all as specified and directed.
91All as per item No 90 above, but 280-335 Ltr.
92DEEP FREEZER Dismantling of defective deep-freezer capacity 205 to 500 ltrs for through checking including all accessories and components reassembling the same after repair/ replacement of defective accessories/ components & testing complete all as directed. Note: (a) New accessories / components required shall be measured and paid separately, as supply only labour charges for fixing are deemed to be included in the unit rate. (b) Repair of over hauling rewinding compressor motor, repair/ replacement of sealed compressor unit recharging of compressor oil and refrigerant gas etc shall be measured and paid separately. (c) oldserviceable accessories / components removed shall be fixed as directed for fixing shall be deemed to be included in the unit rate.
93Supply onlyBlower motor fan bladefor deep-freezer205 to 320 litres.
94Supply only Wiring set complete of PVC insulated cable stranded copper conductor connecting clip.
95Supply only thermostat which including plastic regulator knob. Make – INDFOSS/WHIRPOOL/ ANNAPURNA.
96Supply only relay switch. Make : SHRIRAM/ ANNAPURANA.
97Supply only overload protector. Make SHRIRAM/ RANUTROL/HI – TECK.
98Supply only blower motorfan blade for deep-freezer 500 litres.
99Supply only relay switch for deep freezer 500 ltr. Make : SHRIRAM/ ANNAPURANA.
100S&F compressor rotary energy efficient/reciprocal and capacity of original manufacturer and connecting with existing system testing to leakage including recharging of refrigerant Gas after installing sealed unit to refrigerator of 500 Ltrs Capacity capacitycommissioning including dismantling unserviceable one complete all as specified and directed.
101All as per item No 100 above, but 205-320 ltrs capacity.
102Supply and fix Voltmeter of range 0 – 300 Volts AC of size 2 1/2" Square / Circular for 1 to 5KVA volt stabilizer.
103S&F cable connector 3 way suitable for connection of stabilizer with brush, screws of different size for 1 to 5KVA volt stabilizer.
104S&F flexible AC cord consisting of one 3 core flexible cable of size 40/0076 mm of length 1.5 meter including 3 pin plug top 15 Amps for 1 to 5KVA volt stabilizer.
105S&F main transformer suitable for automatic line voltage corrector 5 KVA 230 Volts 50Hz for 1 to 5KVA volt stabilizer.
106S&F relay (time limit) suitable for automatic line voltage corrector of capacity 5 KVA for 1 to 5KVA volt stabilizer.
107S&F voltage regulating printed circuit board (PCB) of suitable size / type including all necessary electrical component & connectionfor operating the voltage stabilizer for out put voltage 220 to 230 Volts (2% tolerance) complete for 1 to 5KVA volt stabilizer.
108S&F voltage regulating transformer of voltage rating 220/12 Volts to 6 Volts bridge type for central type transformer of current carrying capacity 600 MA per second any size to separate the regulating circuit boardfor 1 to 5KVA volt stabilizer.
109NOTES :- 1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.