Providing Pre Painted Galvanized Iron Sheet Covering For Prevention Of Roof Leakage Of Agril. Engineering Department Building At Aau, Jorhat , jorhat-Assam

Assam Agricultural University has published Providing Pre Painted Galvanized Iron Sheet Covering For Prevention Of Roof Leakage Of Agril. Engineering Department Building At Aau, Jorhat . Submission Date for this Tender is 09-08-2022. Sheet Tenders in jorhat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

33146193
Providing Pre Painted Galvanized Iron Sheet Covering For Prevention Of Roof Leakage Of Agril. Engineering Department Building At Aau, Jorhat
Open Tender
Indian
Assam
jorhat
09-08-2022

Tender Details

Providing Pre Painted Galvanized Iron Sheet Covering For Prevention Of Roof Leakage Of Agril. Engineering Department Building At Aau, Jorhat

Key Value

Document Fees
INR 1000 /-
EMD
INR 85400.0 /-
Tender Value
INR 42.70 Lakhs /-

BOQ Items

Name of Work: PROVIDING PRE PAINTED GALVANIZED IRON SHEET COVERING FOR PREVENTION OF ROOF LEAKAGE OF AGRIL. ENGINEERING DEPARTMENT BUILDING AT AAU, JORHAT
Sl. No. Item Description
1Civil works: Dismantling RCC work without causing damage to original slabs, beams etc. and welding steel bars of columns and beams as directed by the department.
2Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B)In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser a) M15 grade concrete or Prop. 1:2:4
3Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (ii) Using 25mm thick plank
4Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (ii) Using 25mm thick plank
515 mm thick Cement plaster in single coat on single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
6Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar
7Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
8Providing colour coated DURASHINE/TATA BLUESCOPEzinc-aluminium profile sheet(total coated thickness=0.45mm) of nominal 1015mm effective cover width and nominal 28mm deep ribs with subtle square fluting in the five pan at nominal 203mm centre-to-centre including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) (A) DURASHINE/TATA BLUESCOPE ROOF PROFILE (0.45mm(TCT) x 1072mm)
9Providing colour coated DURASHINE/TATA BLUESCOPE zinc-aluminium roof , wall and tile profile sheetaccessories(total coating thickness=0.45mm) including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) (i) Plain Ridge
10Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
11Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
12Extra over item Nos. 2.2.1 (I) (B),above for each subsequent floor or part thereof above the 1st floor level.
13Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
14Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. a) On Single coat plaster
15Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
16Water supply works Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
17Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. (v) 63 mm dia.
18Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 1000 litre capacity (a)Sintex make
19Supplyingfitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)