Delhi Development Authority-DDA has published Maintenance Of M / O Pump Sets And E.I. At Various Places In Dwarka. I.E.I. Of Store / Office / Selling Counter / Toilet In Various Parks / Greens As Per Inventory Attached Under Hd- Dwarka.. Submission Date for this Tender is 07-07-2022. Electrical Maintenance Tenders in dwarka Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C (DSR - 1.1.3) |
2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (DSR-1.15.3) |
3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required. a) 2 X 2.5 sq.mm +1 X 2.5 sq.mm earth wire (DSR- 1.7.2) |
4 | a) 2 X 4 sq.mm +1 X 4 sq.mm earth wire (DSR- 1.7.3) |
5 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way , Double door (DSR - 2.3.2) |
6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole |
7 | b) Single Pole & Neutral |
8 | Supplying of following sizes of XLPE insulated PVC sheathed Al. cond. Armoured power cable of 1.1 KV grade including connection, testing etc. as required. (a) 2 X 16 sq. mm |
9 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. a)Upto 35 sq. mm (DSR - 7.5.1) |
10 | Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Upto 35 sq. mm |
11 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (DSR -5.18) |
12 | Supplying, Installation, testing and commissioning of 20 watt LED tube light on wall /ceiling made out of Al. extrusion housing with high efficient LED"s & opal diffuser IP - 20, wiring with all accessories including connections etc. as reqd. |
13 | Supplying and fixing of following sizes of steel conduit along with accessories in surface /recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required. (a) 40 mm. (DSR- 1.20.4) |
14 | Supplying, Installation, testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) motor, class of insulation : B, 3nos. blades, 30cm long down rod, 2nos. canopies, shackle kit,safety rope, copper winding, power factor not less then 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remoteor electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistancemore than 2 Mega ohm, suitable for 230 V, 50 HZ, single phase AC supply, earthing etc. complete as reqd. |
15 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR - 1.26) |
16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR -1.32) |
17 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR-1.5) |
18 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (DSR - 1.50) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy