Construction Of Acadmics Block ( Laboratory ) At Govt. Degree College Drass, drass-Jammu And Kashmir

Public Works Department-PWD has published Construction Of Acadmics Block ( Laboratory ) At Govt. Degree College Drass. Submission Date for this Tender is 22-07-2022. Building Work Tenders in drass Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

32920438
Construction Of Acadmics Block ( Laboratory ) At Govt. Degree College Drass
Open Tender
Indian
Jammu And Kashmir
drass
22-07-2022

Tender Details

Construction Of Acadmics Block ( Laboratory ) At Govt. Degree College Drass

Key Value

Document Fees
INR 5400 /-
EMD
Refer document
Tender Value
INR 5.45 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF ACADMICS BLOCK (LABORATORY) AT GOVT. DEGREE COLLEGE DRASS(Under SDP)
Sl. No. Item Description
1Earth work in excavation by manual means over areas (Exceeding 30 em and upto 1.5 mtr in depth, 1.5 mtr in width as well as 10 sqm. on plan) including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth to be levelled and neatly dressed in :
2ORDINARY ROCK 40%
3ALL KINDS OF SOIL 60%
4Disposal of Mulba/Excavated Earth Beyond 50m (Lead upto 6Km) Outside Campus Area (CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking) as per the direction of engineer in charge
5Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: as directed by Engineer-in-charge. Note :Stockpile the top layer of soil of 200 mm and cover it for reuse in landscape (If soild is fertile or capable to make it fertile), soil test to be performed from ICAR Lab
6ORDINARY ROCK 20%
7ALL KINDS OF SOIL 80%
8Filling available excavated earth (excluding rock) in trenches plinth, sides of foundation etc in layer not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50cm and lead up to 50 m and lift upto 1.5 mtr.
9STONE SOLLING Dumping of stone Excluding cost of stone (inhorizontal on level)
10Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) (crushed) Incld. all sort of Carriage complete
11Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (crushed) Incld. all sort of Carriage complete
12Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete.50 mm thick with 20mm nominal size stone aggregate.Incld. all sort of Carriage complete
13Reinforced cement concrete work in Footing , Pedestal ,Columns , beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement withM25 (1:1:2) (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size)Incld. all sort of Carriage complete
14Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. Incld. all sort of Carriage complete
15Centering and shuttering including strutting, propping etc. and removal of form for: Foundation, footing bases of column
16Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts.
17Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers.
18Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
19Providing and laying autoclaved aerated cement blocks masonry with 100/150/225 mm thick AAC blocks in superstructure above plinth level upto floor V level in cement mortar 1:4 (1 Cement : 4 coarse sand ) and curing complete. The rate includes providing and placing in position 2 nos. 6 mm dia M.S bars at every third course of masonry work.Incld. all sort of Carriage complete
20Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20 mm nominal size)Incld. all sort of Carriage complete
21Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or dash fastener shall be paid for seperately) First class teak wood
22Providing and fixing panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for seperately,all complete as per direction of Engineer-in-charge.(second class teak wood35 mm thick shutter)
23Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick.Second Class teak wood
24Providing and fixing factory made uPVC AIS or FENISTA or KOEMMERLING make white/wood Finish colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sashshall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (Double Glazed Unit or SHGC with <0.25 and >0.35 VLT may be introduced.)
25Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm).
26Providing and fixing factory made uPVC ofAIS or FENISTA or KOEMMERLING make white/Wood Finish colour fixed glazed windows/ventilators comprising ofuPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. Variation inprofile dimension in higher side shall be accepted but no extra payment on this account shall be made. (Double Glazed Unit or SHGC with <0.25 and >0.35 VLT Should be introduced.
27Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
28Providing and fixing casement handle made of zinc alloyed (white powder coated) for UPVC casement window with necessary screws etc. complete.
29Providing and fixing DGU ( with <0.25 SHGC and >0.35 VLT glazing in uPVCwindow, ventilator shutters and partitions etc. with proper sealing as per norms etc. complete as per the architectural drawings and the directions of engineerin- charge. ( Note : DGU with <0.25 SHGC and >0.35 VLT)
30TOUGHENED DGU glass panes of 5.0 mm thickness SAINT GOBAIN / ASAHI INDIA GLASS /HNGIL make asapproved by engineer in charge Qty vide window openings @80%
31Pebble dash plaster upto 10m height above ground level with a mixture of washed pebble or crushed stone 6mm to 12.5mm nominal size dashed over and including fresh plaster in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 Coarse sand) and top layer 10mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.
32CEMENT PLASTER (IN COARSE SAND) 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand) (PPC or cement with >25% flyash is recommended.)
33Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
34Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer (Note: It Should have Low or No VOC as per Green Building guidelines)
35Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (Note: It Should have Low or No VOC as per Green Building guidelines)
36New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (Note: It Should have Low or No VOC as per Green Building guidelines)
37Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)(Note: It Should have Low or No VOC as per Green Building guidelines)
38Preparing newly primed wooden surface for painting by way of filling of putty sand papering rubbing complete.
39Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.(Note: It Should have Low or No VOC as per Green Building guidelines)
40Providing & Fixing finished brass hanging type floor door stopper with necessary screws etc complete.
41Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete i.e Size of tile 600x600 mm ( Kajaria/Somany/Cera or Any approved Brand as per Engineer In charge)
42Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
43Extra for pre finished nosing to treads of steps of kota stone
44P/F 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in colours, shades except burgundy bottle green, black of any size asapproved by engineer-in-charge in Skirting, risers of steps, and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 course sand) and jointing with grey cement slurry @3.3kg/sqm including pointing the joint with white cement and matching pigments etc., complete.
45Providing and fixing water closet squatting pan ( Indian type W.C. pan) with 100 mm sand cast Iron P or Strap, 4/2 litre low level P.V. C. flushing cistern including flush pipe (of approved make) "manually controled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. (Note : It should have flush rate of with Flush rate of 4/2 Litre per Flush or less ) (Dual flush 4/2L WC cistern with bottom inlet for compact back to wall Rimless toilet)
46Orissa pattern white vitreous china W.C. pan of size 580x440 mm with integral type foot rests. JAGUAR/CERA Make
47Providing and fixing white vitreous china pedestal type water closet EWC (European type W.C . .pan) with seat and lid, 4/2 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever requied: (Note : It should have flush rate of with Flush rate of 4/2 Litre per Flush or less )
48W.C. pan with lSI marked white solid plastic seat and lid. JAGUAR/CERA Make
49Providing and fixing wash basin with C.I./M.S. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
50White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps JAGUAR / CERA/HINDWARE Make
51P/F of mirrors of superior glass with plastic moulded frame(of approved quality) and of required size and shape. With 6mm thick hard board backing. Rectangular Shape 1500 x 450 mm
52Providing and fixing soil waste & vent pipe of Prince or equalant
53PVC Pipe. 110mm dia (10 feet unit Length)
54PVC Pipe. 75mm dia (10 feet unit Length)
55PVC Bend 110mm dia
56PVC Bend 75mm dia
57PVC Tee 110mm dia
58PVC Tee 75mm dia
59PVC Collar 110mm dia
60PVC Collar 75mm dia
61PVC trap 110mm dia
62PVC trap 75mm dia
63PVC Socket 110mm dia
64PVC Socket 75mm dia
65PVC door junction 110mm dia
66PVC door junction 75mm dia
67CPVC PIPES AND FITTINGSProviding and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having Chemical resistance property thermal stability for hot and cold water supply, incliding all CPVC plain and brass threaded fittings. This includes joining of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer Incharge
68Internal work-exposed on wall, including fixing theg pipe with clamps at 1.00 meter spacing 50mm nominal outer dia pipe
69Providing and fixing 3 layer Thermex Pipe PP-R (Poly propylene Random copolymer)pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge.Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
70PN-16 pipe , 25mm OD(SDR-7.4)
71PN-16 pipe , 32mm OD(SDR-7.4)
72P/F CP brass toilet paper holder including cost of wodden,PVC,play etc.
73Providing and fixing Wall mount Liquid Soap Dispenser of approved brand
74Providing and fixing accessories of standard and quality make of approved manufacturer including all necessary fixtures required.
75L-Drops for room door
76T-Bolt for Windows
77T-Bolt for doors
78Handles for door
7915 mm C.P. brass tap with elbow operation lever
8015 mm C.P. brass 2 in 1 tap
8115 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
8215 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
83C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-incharge.
8415 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
8515 mm C.P. brass ABS Health FaucetJet Spray with Hose and Holder of approved quality conforming to IS standards (KOHLER/JAGUAR/CERA)
86Providing and fixing Stainless steel SS-304 Grade L Shaped 90° Wall Mounted Grab barsNear EWC (European Water Closet) of approved brand for Disable-friendly Bathroom/Toilets as per standard and specification.
87Providing and fixing Stainless steel SS-304 Grade Foldable Grab bar For Disable-friendly Bathroom/toilets Make: Jaquar/ Equivalent per standard and specification.
88SOLAR WATER HEATER (Cost includes Cold Water Tank, Hot Water Tank, support structures, heat exchanger, electrical backup and installation and commissioning at site. Additional piping will be charged as per actual. These are only indicative costs.)
89Supply installation testing and commissioning of Geyser 50ltr Capacity horizontally mounted of approved brand (Havells/Bajaj/Crompton or any othet approved brand as per engineer in charge including all fixtures , bolts all complete
90Providing and Fixing Handles with lock system of main doors LAPO Premium Rose Mortise Door Lock Handle Set/ Mortise Lock with Brass Lock Body and 70mm Brass Cylinder Set with 3 Brass Computer Keys / Zinc Alloy Weather Proof (Matt Finish) or Godrej Locking Solutions and Systems Gloria Antique Brass Door Handle with Lock Set 2C for Home and Office Entrance Door (200 mm, Gold) or any other approved brand as per engineer incharge
91Providing and installation ofPUF (Puf Insulated Tanks) water tank capacity 1000 ltrs of approved brand (SYNTEX OR ANY OTHER APPROVED BRAND) as per direction engineer incharge
92Design Supply and installation/Fixing staircase railling ofstainless steel (Grade 304) railing(Top Handrail Dia> 50mm , two number intermediate Horizontal tubes Dia>25mm and Rectangular Two Pair Balusters Dia >38mm @1000mm C/C) made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) including fixing the railing with necessary accessories , newal post , balusters and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, necessary screws/fixtures complete jobas approved by engineer incharge (Note : No additional payment shall be made to master pillar/Newal Post )
93THERMAL INSULATION
94Providing wood work in frames ofwalls,false ceiling, partitions etc. sawn and fixed in position :Budloo / Fir wood (Note : False Celling Design should be as perengineer in charge which may be of different level celling)
95Providing and fixing 12 mm thick tongued and grooved Pine wood(Soft Wood ) 4-5 inch in width panelling or wall panels in walls and celingincludining all necessary fixtures including cornice with necessary screws, priming coat on exposed surface etc., complete. Brand - Rait Wood
96Preparing newly prepared panneled surface for polishing by way of filling of putty , sealer andsand papering rubbing and applying hard polish,glossy polish in sequance over the prepared surface complete job
97Providing and fixing thermal insulation with specified wool and density conforming to IS: 8183, 50 mm thick, wrapped in 200G Virgin Polythene bags fixed to walls with screws, rawl plugs and washers and held in position by criss-crossing GI wire etc. complete as per directions of Engineer-in-charge.With resin bonded rock wool with density 48 kg/cum
98Wooden planking, tongued and grooved in flooring including fixing with iron screws complete:25 mm thick Second class teak wood
99Supply and installation of High Quality self regulating heat tracerfor Specialized Heating Solutions for Winterisation of water pipeline including all accessoriescompleteincluding Supply and installation ofCircuit Control Panel with RCBO MCB ,THERMOSTAT (0-120) DEG C, power connector-two way-6 sq.mm, w.p. splice connector,w.p. tee connector,end seal,mounting kit-w.p. jb,g.i. pipe strap 4",al. adhesive tape roll( 50 mm w x 20 m l),f.g. adhesive tape roll (DANFOSS Make OR CHROMALOXany other approved brand as per the direction of Engineer-In-Charge)
100Supplying and fixing High Quality32mm ThickNitrile Insulation Tube for water pipelineof approved brand2 InchSize (Armaflex Class-o Armacell), rockwool ofapparent density 128 Kg/m3 on outer side of nitrile tube of 50mm thicknessincluding alumunium duct clading (Alumunium Sheet Guage Thickness = 0.46MM TO 0.71MM )of approved quality and finish as per the direction of engineer in charge (Nitrile Tube 32mm > Rock Wool 50mm > Alumunium Duct Clading 0.46mm to 0.71mm)
101Supply and installation of Reflective Bubble Aluminum Foil Insulation / Aluminium Silver Bubble Sheet 210 GSM (7 mm) ThickLight Weight Reflective Insulation , Max Withstanding Temperature -40 degree To +110 Degree Waterproof insulation all complete
102Supply and installation ofelectrical Underfloor heating mats for floor heating systemsnon-corrosive, flexible heating elements including cables, pre formed cable matsincluding smart thermostatand digital electrical control panel all complete (STIEBEL ELTRON / DANFOSSOr any other approved brand
103Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg./sqm. and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured.
104Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
105Providing of fabricated steel roofing truss, purlins, rafters, posts, plates ISA.65x65x6mm ,ISA.50x50x6mm, 40x40x6mm, ISMC 75mm ,65mm,50mm,Plates 8mm,10mm thick, including cutting hoisting fixing in position and applying a primingtwo ormore coat of approved steel priming/paintingall work complete job. including launching of trussesSteel truss @ 3.5kg/sft
106COST OFPVC WHEELED DUSTBINS 120L OF DIFFERENT COLOURS FOR SEGREGATED WASTE COLLECTION WITH FOOT PEDAL (3 NUMBERS DUSTBIN SET)
107Supply and installation of ABC Fire Extinguisher, 6 Kg 4Sets (Note : It should be Halon free)
108Hi-Flow MP1-2 HP Centrifugal Pump Havells/Crompton/kirloskar (Note :Pump should be minimum BEE 3 star labelled or above)
109Provision for providing and fixing ornamental Shingstak (Ladakhi wood carving over exterior Windows and main entrance door) (Design as per the direction of Engineer-In-charge.) including polishing all complete
110Providing and fixing 19 mm thick plywood of appoved brand (Century Ply Or Greenply Industries Limited (GIL) Or any approved Brand ) and manufacture including fixing of decorative laminate sheet over 19mm ply using synthetic resin adhesive , nail,screws,hinges ,Handels , Ball Bearing Telescopic Channel (Godrej or any other approved brand) and carriage all complete.
111Providing and fixing wooden colour aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 2.5 Kg/m10 Gauge Thickness
112Powder coated aluminum (minimum thickness of powder coated 50 microns)
113Providing and fixing wooden colour aluminum work For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM (2.3 Kg/m10 Gauge Thickness)
114Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
115With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
116Supply, installation, testing and commissioning of 10 passenger (680 Kg.) Machine Room Less (MRL) elevators havingspeed 0.5 MPS serving differentfloors in the existing hoist way as per details below , conforming to latest lift act and modern lift design in the existing lift well. and as perCPWD general specifications electrical works (Lift & Escalators) Part-III 2003 as required. ((Make: OTIS,Johnson,KONE, Thyssenkrupp , Schindler,Mitsubishi Or any other approved brand as per Engineer In Charge) (i) Speed :- 1.5 mps (ii)Floors : 2 ( G + 1 Floor) (iii) Travel : 7 Meters (approx) (iv) Stops andOpening : 2 ( Stops and 2 Openings, All opening on the same side, (v) Controller : FULLY AUTOMATIC MICROPROCESSOR-BASED CONTROL PANEL & INVT MAKE V3F DRIVE AS PER EN-81 LIFT STANDARD DULY HARMONIZED & INTERFACED WITH THE MACHINE & DRIVE. (vi) Machine :GEARLESS MACHINE WITH AC THREE PHASE SYNCHRONIZE MOTOR AND CE CERTIFIED MAGNETIC BREAK SUITABLE FOR 13 PERSONS (vii) Automatic rescuedevice complete with dry. maintenance free batteries of suitable capacity as required. (viii) Operation : Micro processor based SIMPLEX OPERATION system with / without attendant. (ix) Power supply : 4 wire AC 400/440 Volts, 3 Phase, 50 Cycles (x) Type of Doors : AUTOMATIC WITH MULTI RAY (minimum-94) ELECTRONIC DOOR SAFETY SENSOR CURTAIN
117(a) Car :- Power operated, STAINLESS STEEL FINISH SIDE SLIDE OPENING GLASS DOOR WITH SS FINISH DOOR FRAME with LED light and cross flow fan in top false ceiliing.STAINLESS STEEL MIRROR FINISHE BACK PANEL IN CABIN WITH SS HAIRLINE FINISH SIDE CABIN WALL & TOP FALSE CEILING.[The car inside shall be of minimum dimensions 1600 mm (wide) x 1600 mm (deep)x 2200 mm (height) ]
118(b)Landing door :- Power operated STAINLESS STEEL FINISH SIDE SLIDE OPENING GLASS DOOR WITH SS FINISH DOOR FRAME
119(xi) Hand Rail : A hand rail not less than600 mm long at 900 mm above floor level to be fixed adjacent to control panel in the lift car in three sides.
120(xii)Voice announcement system in the car, to announce the position of elevator in the hoist way or the car passes or stops at floor served by the elevator.
121(xiii) Fireman switch at Ground floor
122(xiv) The control panel to be equipped with braille/raised numbers for accessibility.
123(xv) INTERCOM SYSTEM AT GROUND FLOOR LIFT ENTRANCE AND CONTROL PANEL in CAR CABIN
124SEPTIC TANK Excavation work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains(not exceeding 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.(SIZE 20" X 10" )
125ORDINARY ROCK=80%
126ALL KIND OF SOIL=20%
127Disposal of Mulba/Excavated Earth Beyond 50m (Lead upto 6Km) Outside Town Area (CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking)
128Providing and laying position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1:3:6 (1 cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) (crushed)MUD MATE Incld. all sort of Carriage complete
129Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 course sand : 12 graded stone aggregate 20 mm nominal size)upto plinth level with cement mortar 1:6 ( 1 cement : 6 course sand)and curing complete (Quarry Stone)
130Dry random rubble masonary with hard stone in foundation & plinth using quarry stone with bond stoneIncld. all sort of Carriage complete
131Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)Incld. all sort of Carriage complete
132Providing & fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position in cement mortar 1:3 (1cement:3 coarse sand), cost of required centring, shuttering and curing complete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20 mm nominal size)Incld. all sort of Carriage complete
133Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.Incld. all sort of Carriage complete
134Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms. SEPTIC TANK/SOKAGE PIT
135Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. SEPTIC TANK 50 mm thick with 20mm nominal size stone aggregate.Incld. all sort of Carriage complete
136Supplying and fixing C.I. cover without frame for manholes: 560 mm diameter C.I. cover ( heavy duty) the weight of the cover to be not less than 108 kg
137CEMENT PLASTER (IN COARSE SAND) 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 coarse sand)Incld. all sort of Carriage complete