Electrification Work From Nawab Yusuf Road To Tharnhil Road To Patrika Marg Prayagraj , prayagraj-Uttar Pradesh

Allahabad Development Authority-ADA has published Electrification Work From Nawab Yusuf Road To Tharnhil Road To Patrika Marg Prayagraj . Submission Date for this Tender is 22-07-2022. Electrification Work Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32866058
Electrification Work From Nawab Yusuf Road To Tharnhil Road To Patrika Marg Prayagraj
Open Tender
Indian
Uttar Pradesh
prayagraj
22-07-2022

Tender Details

Electrification Work From Nawab Yusuf Road To Tharnhil Road To Patrika Marg Prayagraj

Key Value

Document Fees
INR 5900 /-
EMD
INR 1163000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Electrification Work from Nawa Yusuf Road to Tharnhil Road to Patrika marg Prayagraj
Sl. No. Item Description
1Supply, installation, testing and commissioning of 3 Way, 11 KV, 630, Amp outdoor type Ring main unit ( RMU) including wiring RCC foundation, earthing etc. complete in all respects Make Schneider or as UPPCS Reqd. Rate MR
2Supply, installation, testing and commissioning of 4-way, 11kV, 630 Am outdoor type Ring main unit ( RMU) including wiring RCC foundation, earthing etc, complete in all respects Make Schneider or as UPPCL Reqd 250 KVA 11/433KV On Double pole Structure.
3MS Channel ( Dropper) 100 x 50x2028
4Stone Pad 300x 300x 75 M
5Clamps for LT, T-off with bolts & nuts.
6Holding Clamps for top channel TPMO & fuse set etc, with bolts & nuts.
7MS Top Channel ( 125x65x224mm)
811 KV Disc insulator T&C type 4500 Kg.
911 KV Disc Fitting.
10MS Channel 125x65x1300 ( T-off)
1111 KV Pin insulator
1211 KV pin with nut.
1311/0.4 KV T/F 250 KVA
1411 KV TPMO
15Lt incoming Panel with metering equipment & fixing arrangement.
16Copper L piece 50x225x10mm ( LS)
17Copper L piece 50 x 225x12mm ( LS)
18Al leg long barrel.
194 core LT MCB with Box ( LS)
20Danger Board barbdd wire including jumping
21Stay complete ( Stay rod 16x 1800mm, stay wire 5Kg stay lamp, bolt&nut with grouting.
22Concreting of poles ( 0.880 Cu.m.each)
23Earthing of pole by MS earthing rod of 20x2500mm and 6 SWG earting wire etc complete.
24Red oxide paint.
25Aluminium paint. Plinth for size 2x2x1.5
261) Cement
272) Sand
283) Coarse sand.
294) Brick Ballast.
305) Brick First Class
316) Stone ballast
327) MS Channel 125x65
338) MS Twisted bar of size 20 mm
34S/F of factory fabricate and wired metal Gland dust & vermin proof floor mounting distribution TPN feeder pillar with incoming 400 Am. 1 Nos MCCB and outgoing 200 Amp. 2 Nos. = 100 Amp 1 Nos=63 Amp 1 Nos cubical type with required sleeking and mooting on non Hygroscopic support as CMC/BMC. With 3 No indicator, The Pillar should be fabricated with CRCA sheet 2 mm locking arrangement complete with cable Gland complete.
35S/F of TPN/Telex Fedder4 Pillar Cubical Bix made of 45mm x 45mm x45mm Angle iron frame and 14 SWG MS Sbheet with Both side Lockignarrangement. Dust and Vermin Proof consisting with copper bus Bar on Henry type Fuse unit on 2 No. 500 Amp and 3 No. 300 Amp. Tailless unit Completethe Box shall be Painted with approvedaluminium Paint over Red Oxide Primer in 1:3:6 CC foundation as directed by E/I.
36S/F of 200 Amp Busbar Box made of 16 SWG CrCa Sheet including TPN Aluminium Busbar Complete with locking arrangement with required Clamps nuts& bolts and grouting/ Fixed on Wall ( if required on Angle stand angle will be measured in MS Items)
37S/L of Aluminiuum conductor PVC Insulated armoured served sheathed 400Sq mm x 3.5 Core LT cable 1100 volts grade at a deopth of 750 mm below groundlevel over a cushion of 756 mm. Thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable sie or as directed by the E/I, complete in all respect.
38Same as Above but size 240 Sq mm x 3.5 Core.
39Same as aAbove but size 120 Sq mm x 3.5 Core.
40Same as Above but size 50 Sq mm x 3.5 Core.
41Same as Above but size 16 Sq mm x 4 Core.
42Same as Above but size 10 Sq mm x 2 Core.
43S/L of 3 Core standard aluminium conductor XLPE ( Cross linked Polyethylne) insualted PVC bedded, Galvanied flat steel strip armored 185 Sqmm 3 Core 11 KV grde cable confirming to I.S. 7098 ( Part-II with lates amendement) at a depoth of 900 mm below ground level ovdr a cushion of 100 mmthick fine rriver. sand al around and protected with well burnt bricks in sides and on top purt across. The armoring of cable shall be properly connected with eaerth conductorby clamps etc.
44Same as Above but size 70 Sq mm x 3 Core
45S/F of 185 Sq mm 11 KV joint Kit complete. Rate PSR
46S/F of 70 Sqmm to 120 Sqmm 11 KV joint Kit complete.
47S/F of 400 Sq mm cable Lugs ( Item as UPPWD SOR 180
48S/F of 240 Sq mm cable Lugs ( Item as UPPWD SOR 18)
49S/F of 120 Sq mm cablle Lugs ( Item as UPPWD SOR 18)
50S/f of 50 Sq mm cable Lugs ( Item as UPPWD SOR 18)
51S/F of 16 Sq mm cable Lugs ( Item as UPPWD SOR 18)
52S/F of 10 Sq mm cable Lugs 9 Item as UPPWD SOR 18)Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.
53S/F of 3.5 CX400 Sq mm cable Gland ( Item as UPPWD SOR 18)
54S/F of 3.5 CX 240 Sq mm cable Gland 9 Item as UPPWD SOR 18)
55S/F of 3.5 CX 120 Sq mm cable Gland 9 Item as UPPWD SOR 18)
56S/F of 3.5CX 50 Sq mm cable Gland ( Item as UPPWD SOR 18)
57S/F of 4CX 16 Sq mm cable Gland( Item as UPPWD SOR 18)
58S/F of 4CX 10 Sq mm cable Gland ( Item as UPPWD SOR 18)
59Dismantling & Store/Stret light PolePCC/Rail as per direction of UPPCS with Loading unloading cartage of Pole embedded in brick ballast & CC foundation etc. as required.
60Dismantling of over head lines Wires comprising of copper/aluminium overhead conductor, G.I., wire, cross arms, insulators etc, as Required & Deposite as per direction of UPPCL with Loading unloading cartage of all material with proper listing.
61Dismantiling & Removal of 11 KV S/S Transformer with Loading Unloding with Proper shifting includign connections Structure Complete. Rate PSR.
62S/F Steel tubulr Pole 9 M. Long designated 410 SP-32 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect.
63S/F Steel tubulr Pole 9 M. Long designated 410 SP-32 in 1:3:6 cement concrete foundation including excavation back fillingetc. Complete in allrespect. Rate based on S.I. No. 613/2018 on Weight basis.
64Earthing of pole by MS earthing rod of 20x2500 mm and 6 SWG earthing wire etc complet.
65S/F of 100 mm dia GI Pipe Clas B Make jindal Complete with required clamping.
66Supplying and fixing cable route marker with 10 Cm x 120x5 mm thick G.I. plate with inscription there on, bolteed/welded to 35 mm x 35x 6 mm angle iron, 60 long and fixing the same in ground as required.
67Suply and burying of 40mm dia x 4.5 metres long.G.I. Pipe vertically for earthing haing 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron 9 and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer/in-charge complete in all respects as per drawing.
68Deducation of Cable Rate during erection in Pipe/Duct ( Duct will be made by civil work Estimate)
69Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 9 1cemtn: 2 fine sand) including testing of joints etc. complete:150mm dia R.C.C. pipe Supply & laying of following DWC HDPE pipe 6 Kg ISI marked alongwith all accessories like socket, bend couplers etc. conforming to IS 14930, Part Ii complete with fitting and cutting. Jointing etc, direct in groudn ( 75 cm below ground level) including excavation and refilling the trench but excluding sand cushionng and protective covernign etc. copete as required.
70Same as above 90 mm dia ( OD-90 mm & ID-76mm nominal) 6 KG ISI marked along with all accessories.
71Supply & fixing of 10 mtr GI Octagonal Pole of approved make ( top dia 100 mm, Bottom dia 200 mm and base plate 16mm thik) having 3 mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation & back filling and Required T&P completee in all respect.
72Supply and fixing of LED Street light Fitting With mandantry driver set having die cast aluminium body and lencer suitable for 110 to 130 Watt. Confirming to IP 600 Protection having companry logo complete in all respects CatAAA 15400-16500 system lumens High Power LED with lenses,>110 Im/W,PF>0.95,THD<10% at full load, CRI>70. Potted driver Set ( Not Circuitory) Phase Protection at 440 V & > 300 V auto cut and restart feature, with 5 year warrantee.
73Incomin 100 Amp MCCB-1No Outgoings. 63 Amp. MCCB-2Nos Cat. B Pannel Cubicle Type.
74S/F of following capacity of Automatic street light cubicle control Panel painted with anti corrosive alkeli and acie proof paint considting of the switch TSO 100 serve/Digital type with Contactors, HRC fuses, 40 Amp TPN MCCB, isolating switch metering instrument& instrument box with CTs etc. in case of TPN, complete in all respect.
75Supply and laygn of aluminium coductor PVC insulated armoure d eerved sheathed 25 Sq mm 3.5 core cable 1100 Volts grade at adepth of 750 mm below ground level over a cushion of 75 mm. thicks snad all around and protected with burnt, bricks of sides and on top. On surface the cable run shall be fixedon M.S. clamps etc.5 of suitable sie or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.
76Same as Above but 16 Sq. mm 4 core
77Same as Above but 6 Sq. mm 2 cove
78supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for erthing having 12mm dia Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8SWG GI wire in G.I. Pipe up to appron ( and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
79S/L of 6 Sq mm Twin Flate unarmoured cable complete with proper connections Rate PSR in PDA
80Earthing of pole by MS earthing rod of 20x2500 mm and 6 SwG earting wire etc complete.
81S/F of 25 Sqmm Lugs complete with proper connections.
82Supply and fixing of plain or pin type copper tin plated cable socket ( lug0 to the cable leads, insulating with tape and making connection etc. compelte in all respect as per direction of the Engineer-Incharge (d) 16 sqmm
83Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Inchage. 25 sq. mm 3-1/2 core
84Supplylaying of follwing 50 mm dia ( OD-50mm nominal) DWC HDPE pipe 6 Kg ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Ii complete with fitting and cutting. Jointing etc. direct in groudn ( 75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. copete as required.
85Same as above 90 mm dia ( OD-90 mm & ID-76mm nominal) 6 KG ISI marked along with all accessories
86S/P of Reflecting Red colour 230 mm x 230 mm wide strip 3 m aroudn the pole above 1.5 Mt from GL Logo of PDA Complete in all respect as per direction E/I.
87Deduction fo Cable Rate during errection in Pipe/Duct ( Duct will be made by civil work Estimate)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail