Installation Of Jawahar Lal Nehru Sculpture At Nehru Park In Municipal Area Tonk, Tonk-Rajasthan

Department Of Local Bodies has published Installation Of Jawahar Lal Nehru Sculpture At Nehru Park In Municipal Area Tonk. Submission Date for this Tender is 04-07-2022. Statue Tenders in Tonk Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

32816629
Installation Of Jawahar Lal Nehru Sculpture At Nehru Park In Municipal Area Tonk
Open Tender
Indian
Rajasthan
Tonk
04-07-2022

Tender Details

Installation Of Jawahar Lal Nehru Sculpture At Nehru Park In Municipal Area Tonk

Key Value

Document Fees
INR 500 /-
EMD
INR 31560.0 /-
Tender Value
INR 15.78 Lakhs /-

BOQ Items

Name of Work : NIT 14/05 Installation of Jawahar lal Nehru Sculpture at Nehru Park in Municipal Area Tonk
Sl. No. Item Description
1Pipe Earthing as per PWD specification for electrical Works as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe IS:1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple,wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
2Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured/ Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-(a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P – I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures.(c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR.Armoured Cable 4.0 Sq. mm 2 core
3Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Single pole MCB 6 A to 32 A rating
4Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .8 SWG G.I. ( Hot Dipped ) Wire
5P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time.Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purposeSuitable for 15 kw load (three phase) including contactor, MCB, cable glands, terminal block and locking arrangement
6P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required 2.5 Sq.mm 3 core flat
7Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round/ Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of = 120 lm / watt, THD <10 % ,p.f.=0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) ,maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.Recessed Mounting LED Downlight 18/20W
8Providing & Fixing of ISO certified company made IK10 IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy = 90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT:3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice.driver current <1000mA shown in LM79 report. Fixture must be in compliance with BIS Standards and T.C . Certificate complete in allrespect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .40W LED Post Top Fixture
9Providing & Fixing of Street light bracket made out from following size of " B " class , Medium class G.I. Pipe confirming to IS : 1239 P -1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .40 mm Dia.
10Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .2 x 1.5 sq.mm
11Supply , installation and commissioning of IP68 , IK08 Floor/ground-mounted recessed High efficiency LED underwater luminaire for illumination. Front cover & housing made of high thermal nylon.Silicone gasket. Toughened glass diffuser T=8mm. IP-68 PG-11 copper with nickel coated cable gland.Having atleast 12W.Complete with power supply , water proof connectors , IP rated mounting boxes with glands and terminalwhere ever required as per specification, architectural design requirement, entire instruction and satisfaction of engineer incharge . Make:- K-lite/Philips/Abby.
12Supplying and fixing at site, Bronze Metal Alloy (88% Copper, 8% Tin and 4% Zinc) sculpture including Planning, developing, casting, all loading-unloading, transportation, scaffolding, hoisting, installation with all required T&P, fixing over/on base/surface as per shape -size & placement at all heights as per approved drawing, finishing, surface treatment etc. coveringproperly till the date of opening/inauguration of site etc. Modelling, 3D scanning of model Robotic machining (enlargement of model to desired height), assembling and final detailing, Piece moulding, Wax casting (Lost wax process), Wax chasing, sprung Investing, metal casting, Divesting, metal chasing, Brazing/Welding Finishing and Patina/Colour etc. Complete job in all respect as per approved design & drawing under approval of project consultant, appointed for the project & as per directions of Engineer-In-Charge complete in all (Theme, concept plan, schematic arrangement, other relevant details and drawings of element/statue/sculpture are enclosed. The final drawing shall be provided after award of the work.)respect..Note: Payment shall be made per kg of the finished sculpture (final payment shall be paid after test result of composition-If variation in composition of alloy metal observed the rate shall be paid accordingly). Other masonry, concreting, steel reinforcement plastering etc. required shall be paid extra but additional support if required for bronze metal alloy sculpture, shall be of Stainless steel/ zinc coated iron steel etc. for which nothing shall be paid extra.)
13Providing and Fixing of Stone Chattris of size (3X3X5 ) M in Bansipaharpur stone on 4 pillars of size 0.45M Dia. as per drawing including carving, cladding etc all including required DASA copings and all attached and fixing with SS clamps and fasterners with tenax chemical ,including Planning, developing, making base, carving work, polishing, all loading-unloading, transportation, scaffolding, hoisting, installation with all required T&P (including white cement, pigment, Chemical, SS clamps and fasteners of approved brand etc.), fixing over/on base/surface as per shape-size & placement of approved drawing , finishing, surface treatment etc. coveringproperly till the date of opening/inauguration of site etc. under the direction of engineer incharge and as per approval from Architect
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail