Execution Of Various Works Under Revamped Distribution Sector Scheme ( Rdss ) In 11 Kv Thirukkanurpatty Feeder Of Thanjavur Oandm Division As Per Tender Specification, thanjavur-Tamil Nadu

Tamil Nadu Generation And Distribution Corporation Limited-TANGEDCO has published Execution Of Various Works Under Revamped Distribution Sector Scheme ( Rdss ) In 11 Kv Thirukkanurpatty Feeder Of Thanjavur Oandm Division As Per Tender Specification. Submission Date for this Tender is 30-06-2022. Feeder Pillar Tenders in thanjavur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

32808715
Execution Of Various Works Under Revamped Distribution Sector Scheme ( Rdss ) In 11 Kv Thirukkanurpatty Feeder Of Thanjavur Oandm Division As Per Tender Specification
Open Tender
Indian
Tamil Nadu
thanjavur
30-06-2022

Tender Details

Execution Of Various Works Under Revamped Distribution Sector Scheme ( Rdss ) In 11 Kv Thirukkanurpatty Feeder Of Thanjavur Oandm Division As Per Tender Specification

Key Value

Document Fees
Refer document
EMD
INR 7000.0 /-
Tender Value
Refer document

BOQ Items

E-tender forWork Contract for Implementation of RDSS works in Thirukanurpatti Feeder (Agri Segregation) of Thirukanurpatti 110/33-11 KV SS in Thanjavur O&M Division ( Rate offered for per quantity, Invoice shall be claimed for the actual works up to face value inclusive of GST, EPF & ESI by the Contractors)
Sl. No. Item Description
1Excavation of pole pits for pole upto 8.00m length by using JCB/Manual
2Excavation of pole pits for pole above 8.00m length by using JCB/Manual
3Erection of RCC, REC, PSC poles upto 8.00m length by using Crane / Manual
4Erection of RCC, REC, PSC poles above 8.00m length by using Crane / Manual
5Excavation of stay pit of 4.5" to 5" depth using JCB/Manual
6Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc.
7Fixing ofV cross arm 3.5feet
8Fixing of LT Pin insulator with Pin
9Fixing of shackle with MP
10Fixing Tapping Channel Cross Arm
11Fixing of LT 1 phase cross arm
12Fixing of LT 3 phase cross arm
13Fixing of HT TI fitting
14Fixing of 11 KV Disc with MP
15Fixing of 11 KV Pin with Insulator
16Fixing of Alu- Knob
17Fixing of HT LAS ( 3 Nos)
18Fixing of LT LAS ( 3 Nos)
19Numbering of poles including base painting and with cost of paint
20Paving and stringing of conductors of sizes upto 7/4.09 mm ACSR or other equivalent conductor
21Paving and stringing of conductors ofabove7/2.59 mm ACSR or other equivalent conductor upto 7/3.35mm ACSR or other equivalent conductor
22Paving and stringing of conductors ofup to 7/2.59 mm ACSR or other equivalent conductor
23Painting of Tapping Channel cross arm
24Painting of 1 phase cross arm
25Painting of 3 phase cross arm
26Painting of Back Clamps inclusive of Paint(Red Oxide/Alu. Paint)
27Painting of Stay Clamps inclusive of Paint(Red Oxide/Alu. Paint)
28Painting of V cross arm 3.5feet
29Painting of HT TI fitting
30Transporting of Distribution Transformer / Line materials from stores to office / site upto 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
31Transporting of conductors of all sizes from road side to pit locations upto one KM of Conductor
32Loading or Unloading ofall REC, RCC, PSC pole upto 8.00 m length
33Loading or Unloading ofAll REC, RCC pole above 8.00 m length
34Loading of Conductor
35Unloadingof Conductor
36Loading or unloading of Distribution Transformer Upto 100 KVA
37Erection of Distribution Transformer structure complete as per TNEB standard including painting, feeders arrangrment, colour washing of RCC poles etc.. Fixing of poles type to be unit HT / LT LAS and jumpering 3 Nos Earth pits with earth trough except erection of Distribution Transformer. (Data as per Annexure II)
38Erection of DP structure with stay as per TNEB standard including fixing of top channel, cross bracing, concreting, painting, colour washing etc., (Data as per Annexure I) With 11 KV AB switch using all types of poles of size 9.14 m and above length
39Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa. Upto 25 KVA Distribution transformer
40Erection of Distribution Transformer including loading of Distribution Transformer at stores and erection at structure or vice versa. Above 25 KVA to 100 KVA
41Transportation of all type of poles by bullock cart or other vehicle (for all sizes of poles including loading and unloading) For a lead upto 5 KM
42Labour for the Erection of 11 KV Breaker complete setusing Crane with proper levelling, proving holes cutting, jointing, wherever required, Erection of 3 Nos CTs without crane, Providing conductor jumpers from Isolator/Bus to Breaker, Breaker to CT"s, CTs to Isolators, Supply & Erection of CT Junction Box, Earthing steels Four Risers Breaker Structure from Earthmat/electrode using 50x08 MSF, Providing Flexible Copper Earthing loops to the Breaker earthing points, Supply & painting of first primer coat of redoxide and two coats of Bus green Enamel paint on to the Earth risers inculing cost of reputed make paints, consumable, VAT, frieght, etc, and as directed by the field engineer.