}

Construction Of Picnic Spot In Zonal Park At Tajnagri Phase 2, agra-Uttar Pradesh

Agra Development Authority has published Construction Of Picnic Spot In Zonal Park At Tajnagri Phase 2. Submission Date for this Tender is 28-06-2022. Civil Work Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

32786309
Construction Of Picnic Spot In Zonal Park At Tajnagri Phase 2
Open Tender
Indian
Uttar Pradesh
agra
28-06-2022

Tender Details

Construction Of Picnic Spot In Zonal Park At Tajnagri Phase 2

Key Value

Document Fees
INR 2800 /-
EMD
INR 349300.0 /-
Tender Value
INR 1.74 Crore /-

BOQ Items

dk;Z dk uke %& rktuxjh Qsl&2 fLFkr tksuy ikdZ esa fidfud LiksV dk fuekZ.k dk;ZA
Sl. No. Item Description
1Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer in charge within a distance of 60mtr. ( 200feet) (P.S.)
2Dismantling of girders, trusses and other steel work including stacking of dismantling materials as directed by Engineer in Charge with in a distance of 60 mtr.(P.S.)
3Dismantling Cement Concrete or brick or granolithic floors with stone flagged or tiled floor, including stacking of dismantled materials as directed by Engineer-in-charge within a distance of 60 meters (P.S.)
4Excavation in Foundation in ordinary soil ( Loam, Clay or Sand ) including lift upto 1.5 m and lead of 30 meter and including filling watering & ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation trenches. (Ch-4 S.I. No. 1 SOR 2022-23)
5Providing and laying in cement concrete M10 grade Nominal Mix 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form work in Foundation and Floors.(Ch-5 S.I. No. 3 SOR 2022-23)
6Reinforcementcement concrete work in beams, suspended floors, roofs having balconies, shelves, chajja, bands, staircases and spiral stair cases above plinth level upto fifth floor lavel. including cost of centering, shuttering, finishing and excluding reinforcement 1:1.5:3 ( 1 Cement : 1.5 coarse sand (Zone- III) : 3 Graded stone. (Ch-5 S.I. No. 11 SOR 2022-23)
7Reinforcement of Reinforced concrete or reinforced brick work (When not included in and an over all rates) brought to required shape as necessary including bending for proper completion of the work and including the supply of steel and its waistage Bend, hooks, Binding wire and authorized over lapping shall be measured upto floor two level. (S.I. No. 504 SOR 2020-21) 10mm to 12mm tor (TMT Bars) Fe-415
8Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes (PWD 2022-2023)
9Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face fine dressed with rough backing. (CH-14 Item No. 23 SOR 2022-23)
10Class-150 ( non modular) brick work in 1:4 cement and coarse sand mortar above plinth level upto floor five level including supply of all materials, labour, necessary cutting and moulding of brick work and t & p etc. and also including honey combed brick work in thickness of wall more than 12 cm. Required for proper completion of the work. (Ch-6 S.I. No. 2 SOR 2022-23)
11Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Granite work) Item No. 8.3.2 DSR-2021
12Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. (Wedge expansion type) (DSR-2021) 8.8.1.3 Fastener with threaded dia 12 mm
13Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : (CH-9 Item No. 7 SOR 2022-23) Powder coated aluminium (minimum thickness of powder coating 50 micron)
14Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)(Ch-9 S.I. No. 8.21.3 SOR 2022-23)
15Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(Ch-10 S.I. No. 10.25.2 SOR 2022-23)
16Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work(Ch-15 S.I. No. 13.61.1 SOR 2022-23)
17Chemical treatment of sand stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. (PS)
18Providing and fixing of Cobble stone flooring (150x150x150) of sand stone laid on 100mm PCC 1:4:8 with cement mortar pointing 1:3 Between stone blocks (Rate based on analysis)
19Providing and fixing of Cobble stone flooring (150x150x75) of Granite stone laid on 100mm PCC 1:4:8 with cement mortar pointing 1:3 Between stone blocks (Rate based on UPRRN analysis)
20Provinding and fixing galvinized iron of polyster based powder coating plain sheet of thickness of 0.5mm of size 600 X 600 mm, with following technical details. Sound absorption (NRC) :0.6(with Acoustic pad) sound attenuation Dncw (dB):28(with Perforation), 34(without Perforation) Light Reflectance(%):85 Humiditiy resistance(% RH): Not affected by humidity fire reaction: Class O/Class 1(BS 476)Fire resistance(hour):1 perforation:2mm (PS)
21Providing and fixing Round Shape RemovableS.S. Bollard manufactured in 275mm carbon steel ,overall size 110 mm dia x1250 mm ht. fixing with bolt on M.S. Plate on R.C.C.foundation of 300 x 300 x 450 mm, complete in all respect as per drawing and design & as directed by Engineer Incharge. ( Make Chevron or equivalent made ) (PS)
22Supply of Damper for Kitchen Hood Fabricated out of 20 G Galvanized Steel as per standerd spacifiction and as per Engineer in charge(PS)
23Providing,carving and Fixing of interpretive signages in Bansi paharpur stoneof size 1000x1300x50 mm on inclined plane .Engraving,painting of latters as per drawing and design.The signage stone shall be fixed on the post of same stone of size 300x 300 x 1050 above ground and 1/3 of total heigt of post shall be embedded in ground with neccesary earthwork and concreting etc.complete as per details and drawings and as directed by engineer incharge.(PS)
24Providing 10 mm thick Plaster of Paris ( Gypsum anhydrous) ceiling flat surfaces up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately)(PS)
25Black granite Polished stone flooring with 18mm thick marble stone as per sample of marble shall be approved by Engineer-in-charge over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Black Granite Stone Quality (CH-14 S.I. No. 9 SOR 2022-23)
26Providing and laying integral cement based water proofing treatment BIRCK KOBA including preparation of surface as required for treatment of roofs, consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS. 2645 including adjoining walls upto 300 mm height. (b) Laying brick bats with mortar with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 to required slopeincluding rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. With average thickness of 120 mm and minimum thickness at khurra as 65 mm.(CH-11 S.I. No. 2 SOR 2022-23)
27Supply and hoisting of Sintex or equivalent high density polyethylene seamless of piece moulded tanks and placing the same in proper position including all taxes, labour and T&P etc. for proper completion of work. Tank should be ISI marked, Sintex or equivalent. (CH-19 S.I. No. 2 SOR 2022-23)
28Providing, laying, testing & Commissioning of"C" class heavy duty MS pipe conforming to IS 3589 / 1239 for hydrent and sprinkler applicationsincluding fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps and including painting of two coats of Red Oxide , painting with two or more coats of synthetic enamel paint of Post office redshade complete as required.The installation includes all civil openings ,breakages and making good the same. 150 mm dia MS Heavy duty pipe (PS)
2980 mm dia MS Heavy duty pipe
3050 mm dia MS Heavy duty pipe
3125 mm dia MS Heavy duty pipe
32Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (Item No. 4.6 DSR-2018) 150 mm width X 50 mm depth X 1.6 mm thickness
33300 mm width X 62.5 mm depth X 2 mm thickness
34450 mm width X 62.5 mm depth X 2.0 mm thickness
35Armoured Cable 3.5 core300.0 Sq.mm
36Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core (PS)
3735 sq. mm 3-1/2 core
38120 sq. mm 3-1/2 core
39P & F Ist qualitySENSOR FLUSHING VALVE URINAL 51097 complete in all respect as per direction of Engineer-In-Charge. (PS)
40Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineerin-Charge. External work (CH-23 Item No. 9 SOR 2022-23) 40 mm nominal inner dia pipes
4150 mm nominal inner dia pipes
4275 mm nominal inner dia pipes
43100 mm nominal inner dia pipes
44150 mm nominal inner dia pipes
45Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. (Item No. 14.16 DSR-2018 E&M) 63 mm dia (OD-63 mm & ID-51 mm nominal)
46120 mm dia (OD-120 mm & ID-103 mm nominal)
47Supply and Installation of Ducting under 19 kiosk (Qoutation)
48Supply and installation of exhaust blower of 18000CFM with Electric Panel and starter of L&T, including installation, canas joint and freight. (Qoutaion)
49Supply and installation of exhaust blower of 12000CFM with Electric Panel and starter of L&T, including installation, canas joint and freight. (Qoutaion)
50Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with "code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping. (PS) (250 mm nominal bore)
51Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. (Diameter 900 mm) (PS)
52Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness (Diameter 900 mm) (PS)
53Supply & lowering air line of 25mm dia, G.I. pipe "B" class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. (PS)
54Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge.(PS)
55Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids(Size 9 to 12 mm) (PS)
56Size 3 to 5 mm (PS)
57Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.(PS)
58SupplyofstrainerpipesmadeofERWM.S.blackpipeISImarkoffollowing sizesatthesiteofworkincludingrequiredsizeofslottingasperIS:8110- 1985. 200 mm Nominal Bore. (PS)
59Supply and lowering 25 mm dia GI pipe "B" class having perforation 3 to 5mm sizeallaroundtheGIpipeinzig-zigfashionandmakingairventattop compete as per direction of Engineer inchage. (PS)
60Supplyandloweringventairpipe63mmdiarigidPVCpipe(IS4985)mark classII (4kg per cm2) with reqired all necessary fittings including perfortation of 3to5mm size all around the pipe at including at a distance of 180 to 220mm inzig-zigfashionandmakingairventattopcompleteasperdirectionof Engineer inchage. (PS)
61Drysinkingofwelltrue andverticalinalltypesofsoilsincludingsand ,silt,claymixedupto25% with gravelandriverbedstonesuptosize300mm in any direction complete as per drawing and technical specification for depth up to 5 mtr. (PS)
62Providing andfixing ofFerro cement stepsembeddedinwalls &10 Cm projected out complete (PS)
63ProvidingandlayingplaincementconcreteM15grade(usingmechanical concretemixer)using20mmgradedhardcrusherbrokenstoneaggregate, layinginlayersofnotmorethan15cmthick,forbeddinghavingwidth= outerdiaofpipe(Bc)+200mmor1.25Bc(whicheverishigher),thickness below pipe = 0.25Bc or 100mm (whichever is higher) and haunching = 0.25Bc, forRCCpipesoffollowingsizes,includingcompaction,curing,formwork,etc complete as per drawing and/ or as directed by Engineer. 150 mm internal diameter RCC pipe (PS)
64200 mm internal diameter RCC pipe (PS)
65250 mm internal diameter RCC pipe (PS)
66ProvidingandFixingUnplasticizedPolyVinylChloride(UPVC)SWRPipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make (110 mm dia) (PS)
67Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Coupler (110 mm dia) (PS)
68Providing,laying and jointing of PVC seweragesocketed/RRJ pipeconfirming to IS:15328SN 4 KN/M2 ISI marked pipe in assorted length including PVC/C.I.Special,CID-Jointaftercutting,taperingetc.Thisincludethe excavationoftrenchupto1.5mtr.depthinalltypeofsoilcuttingofroad surfacepavementwhererequiredliftupto1.5mtr.stackingthesoilclear formtheedgeofexcavationandrefillingofsoilafterlayingandjointingof pipelinewithpropercompactionanddisposingofallsurplussoil(min.earth coveroverpipeshouldbe1mtr.)asdirectedwith in leadof 30mtr. Thisalso include getting the pipe linetested and siteclearance etc.complete job (Make of pipe KISAN, FINOLEX, JAIN or equalent). Size 160 mm dia (PS)
69Size 200 mm dia (PS)
70Size 315 mm dia (PS)
71Supply and fixing of Kirloskar make 0.5 HP multi stage hydro Neumatic pump. (Qoutation)
72Supply and fixing of Kirloskar make 1.0 HP multi stage hydro Neumatic pump. (Qoutation)
73Making of 18x18 Ft RCC Gazebo with steel iron including 7x2.5 Ft round pillars of 3Ft depth with base foundation height of 1.5 Ft , also including the inside RCC sitting bench , complete with oxide oil colour , all complete as per direction of Engineer-in-charge. (Qoutation)
74Making of 8x10 Ft RCC Entrance Gate with steel iron including 8x2.5Ft round pillarsof bargad tree design with scissor like decoration, complete with oxide oil colour , all complete as per direction of Engineer-in-charge. (Qoutation)
75Making of 5x1.5 Ft RCC Bench with steel iron including 4x4Ft round pillars in the shape of patta like decoration design , complete with oxide oil colour , all complete as per direction of Engineer-in-charge. (Qoutation)
76Making of 3.0 Ft height RCC Railling on 9 inch foundation wall of RCC complete with oxide oil colour , all complete as per direction of Engineer-in-charge.. (Qoutation)
77Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (CH-9 Item No. 10 SOR 2022-23)
78Supply and installation of Normal Meter Panel:- Design, manufacture, supply, testing and commissioning of Normal Meter panel fabricated out of 16 SWG CRCA sheet steel, IP42, wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. The installation of panel will include receiving, storing, handling, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the Panel manufacturers, civil contractors etc complete with civil work ( PCC , Rcc, Brick work etc.) all respects. The small items such as nut, bolts and other accesories required for erection of panel will be included in the rates. The incoming MCCB shall be thermal-magnetic based with inbuilt O/L & S/C release with E/F protection and all Outgoings MCCB"s shall be thermal-magnetic based with inbuilt O/L & S/C release. All MCCB"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All outgoing MCB"s shall be C type with 10 KA breaking capacity. The above board shall be complete with 3 nos. phase indicating lights, flush mounted Ammeter, Voltmeter, CT"s, PT"s, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm Copper wires. The Meter Panel shall have space suitable for housing of 16 numbers 3 phase electronic type KWHR meters with MCB"s as required for protection. (KWHR meters shall be supplied by the local electric supply authority) INCOMER : 200 AMP FP MCCB (25 KA) BUS BAR : 200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 1.00 sq mm /amp.The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature. OUT GOINGS : 16 nos 32 AMP SP MCB (10 KA) with space for energy meters. (Qoutation)
79Supply and installation of Main L.T. Panel:- Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 42, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires,ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. The instalation of panel will include receiving, storing, handling, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the Panel manufacturers, civil contractors etc complete with civil work ( PCC , Rcc, Brick work etc.) all respects. The small items such as nut, bolts and other accesories required for erection of panel will be included in the rates. MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Easypact CVS / Compact, Siemens - 3VL / 3VT, Legrand-DPX, Havells INCOMERS from 2 Nos. 400 KVA Transformers 1 nos 400 AMP FP MCCB of 25 KA with nos.1 400 AMP FP Contactor (AC3) Metering for incomers 1 nos. 0-500 volt range digital type voltmeter with selector switch 1 set - 415 / v3 / 110 / v3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse. Class 1.0 accuracy 15 VA burden C.T. operated ammeter with selector switch 1 set of 3 CT"s of ratio 600/5A, Class 1.0 accuracy 15 VA burden for APFCR. Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. Power factor meter, Frequency meter. Indications for incomers3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB. BUS BARS:- 2 sections of 600 AMP, 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports at every 450 mm distance, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of Main bus bar & drooping bus bar shall be minimum 1.00 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. OUTGOINGS - All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT"s of accuracy class 1.0 MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL, Legrand-DPX, Havells The varoius combinations of LT Panel shall be as per details below:- LT Panel - 01 (For Substation -01) OUTGOINGS - 3 nos. 200 AMPS TP MCCB. (25 KA) 1 no. 100 AMPS TP MCCB. (25 KA) 4 nos. 63 AMPS TP MCCB. (25 KA) (Qoutation)
80Supply and installation of Distribution L.T. Panel:- Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 42, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required. Set 1 495900.00 495900.00 The instalation of panel will include receiving, storing, handling, installation, testing and commissioning, affecting proper connections with the power and control cables, coordination with the Panel manufacturers, civil contractors etc complete with civil work ( PCC , Rcc, Brick work etc.) all respects. The small items such as nut, bolts and other accesories required for erection of panel will be included in the rates. All incoming MCCB"s shall be microprocessor based with O/L & S/C and E/F protection & All outgoings MCCB"s shall be thermomagnetic type O/L, S/C & E/F release.All MCCB"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified for all MCCB"s breakers is Ics value (service rating). The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT"s & PT"s, etc. Separate CT"s shall be provided for protective and measuring system and for APFCR of capacitor bank with suitable VA. Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose. All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication. MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Easypact CVS / Compact, Siemens - 3VL / 3VT, Legrand-DPX, Havells INCOMING:- 1 nos 200 AMP FP MCCB of 25 KA with nos.1 200 AMP FP Contactor (AC3) Metering for incomers nos. 0-500 volt range digital type voltmeter with selector switch 1 set - 415 / v3 / 110 / v3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse. Class 1.0 accuracy 15 VA burden C.T. operated ammeter with selector switch , 1 set of 3 CT"s of ratio 600/5A, Class 1.0 accuracy 15 VA burden for APFCR. Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. Power factor meter, Frequency meter. Indications for incomers:- 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB. BUS BARS:- 2 sections of 200 AMP, 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports at every 450 mm distance, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of Main bus bar & drooping bus bar shall be minimum 1.00 sq mm / amp. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. OUTGOINGS - All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT"s of accuracy class 1.0 MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL, Legrand-DPX, Havells The varoius combinations of LT Panel shall be as per details below:- LT Panel - 01 (For Substation -01) OUTGOINGS - 9 nos. 63 AMPS TP MCCB. (25 KA) 3 nos. 63 AMPS TP MCCB. (25 KA) with astomacanical Timer etc The Meter Panel shall have space suitable for housing of 4 numbers 3 phase electronic type KWHR meters with MCB"s as required for protection. (KWHR meters shall be supplied by the local electric supply authority) nos. 63 AMPS TP MCCB. (25 KA) with astomacanical Timer etc The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. OUTGOINGS - All outgoing feeders shall be provided with one set of phase indication lamps and trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT"s of accuracy class 1.0 MCCB Make and model :- ABB - T-max, L&T - D sine, Schneider - Compact NS / NSX, Siemens - 3VL, Legrand-DPX, Havells The varoius combinations of LT Panel shall be as per details below:- LT Panel - 01 (For Substation -01) OUTGOINGS - 9 nos. 63 AMPS TP MCCB. (25 KA) 3 nos. 63 AMPS TP MCCB. (25 KA) with astomacanical Timer etc The Meter Panel shall have space suitable for housing of 4numbers 3 phase electronic type KWHR meters with MCB"s as required for protection. (KWHR meters shall be supplied by the local electric supply authority) nos. 63 AMPS TP MCCB. (25 KA) with astomacanical Timer etc(Qoutation)
81Supply and laying of RCC hume pipe NP-3 & Collor (350mm) including Four labour (Beldar). (CH-1 S.I. No. 31 SOR 2022-23)
82Constructing masonry Chamber brick work with common burnt clay F.P.S.(non modular) bricks of class designation 150in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar :3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design(CH-23 S.I. No. 4 SOR 2022-23)90x90x100 cm Inside
83120x120x100 cm Inside
84Supply and fixing of Stainless steel Grease Chamber. (Qoutation)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail