Water Supply And Sanitation Department-WSSD has published Providing Operational Improvement For Improved Water Supply Service Level Of Water Supply Scheme Alampur, Block Samana, District Patiala Under Sub Component 2A ( I ) Of Punjab Rural Water And Sanitation Sector Improvement Project And Jjm. Submission Date for this Tender is 11-07-2022. Water Supply Project Tenders in alampur Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Jul-2022 | Date Extension | Date | 11-07-2022 |
Sl. No. | Item Description |
1 | Pumping Machinery |
2 | Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of(Reputed make) capable of delivering 273LPM against a head of 92mtrof Suitable Sizeincluding G.I. Column pipe of suitable size 60 mtr (in 3 mtr length each flanged screwed and welded on both sides, rubber gaskets nuts, bolts submersible cable (reputed make) complete in all respects as per specifications. |
3 | Credit of Column Pipe & Machinery |
4 | Credit of Submersible Cable |
5 | Providing & fixing electric panel board consisting of electric appliances such as automatic STAR Delta Push Button or oil immersed Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, Kit-Kat etc. complete in all respects. |
6 | Credit of old Control Panel |
7 | Repair of Pump Chamber |
8 | Dismantling cement conglomerate floors (25mm to 50mm) thickincluding concrete base. Floor 18.03 sqm. Apron 22.92 sqm |
9 | Conglomerate floor 50mm thick cement concrete topping 1:2:4. |
10 | 12.5mm thick plaster in 1:4 under side of ceiling complete in all respects. |
11 | Repair of Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. |
12 | Panelled, glazed or glazed and panelled (Double leaf) 40mm thick |
13 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. |
14 | Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
15 | Providing & fixing electrical fitting complete in all respects. |
16 | Providing & fixing ceiling fan and Tubeset of ISI marked complete in all respects |
17 | White washing 3 coats complete in all respects. |
18 | Distempering with dry distemper of approved manufacture two or more coats on old distempetered surface when shade is changed |
19 | Finishing walls with exterior decorative cement based such as snowecem, robbiacem etc. on old work one coat to give an even shade |
20 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
21 | With special quality paint |
22 | Painting two coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
23 | With special quality paint |
24 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
25 | Construction of new toilet complete in all respects. |
26 | Repair of Staff Quarter |
27 | Dismantling cement conglomerate floors (25mm to 50mm) thickincluding concrete base. Floor 18.03 sqm. Apron 22.92 sqm |
28 | Conglomerate floor 50mm thick cement concrete topping 1:2:4. |
29 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
30 | White washing 3 coats inside of Staff Quarter complete in all respects. |
31 | Distempering with dry distemper of approved manufacture two or more coats on old distempetered surface when shade is changed |
32 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
33 | Repair of Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. |
34 | Panelled, glazed or glazed and panelled (Double leaf) 40mm thick |
35 | Repair of RCC OHSR |
36 | One No. RCC OHSR 75000 ltrs capacity having height 25.00 mtr up to FSL and 22.00 m upto bottom slab has been already exists at site. The Repair of OHSR has been taken in this estimate. |
37 | Repair of leakage of Tank Wall and making it water tite |
38 | Painting of C.I Pipes and Specials complete in all respects |
39 | Repair of expansion joint |
40 | 100mm i/d |
41 | Repair of Plinth Protection of OHSR Complete in all respects. |
42 | Cleaning of OHSR with Bleaching Power complete in all respects |
43 | Repair of Gallary & bottom dome, complete in all respects. |
44 | Providing & fixing G.I. Railing with painting etc. complete in all respects. |
45 | Providing & fixing MS Jali on the top of water tank complete in all respects. |
46 | Providing & Fixing manhole cover for OHSR complete in all respects. |
47 | Repair of Water Works |
48 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respect including cost of winding wire & aluminum painting complete in all respects. |
49 | Providing & fixing angle iron pickets with angle 40mm x 40mm x 6mm including cost of concrete & painting complete in all respects as per standard Drawing. |
50 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing. |
51 | Repair of masonry gate pillar complete in all respects |
52 | Repair of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects. |
53 | Repair & Painting of existing Main MS Steel Gate complete in all respects. |
54 | Repair of footpath complete in all respects. |
55 | Repair of toewall in footpath complete in all respects. |
56 | Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressure upto 7 ka.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications. |
57 | Making Connection with Existing Pipe Line complete in all respects. |
58 | Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.. |
59 | Providing proposed water connection to house hold up to wall with Providing MDPE pipe PN 16, 20 mm 2m and G.I Pipe ( as per IS 1239) B- Class, Premium make such as Jindal Hissar as approved by Engineer Incharge 15mm i/d=2.5 mtr, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete (On existing line) |
60 | Providing, Stringing out PVC pipes 6kg/cm2 ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications for street (with manual earth work) |
61 | PVC pipe63mm o/d |
62 | Providing, Stringing out PVC pipes 6kg/cm2 ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing complete as per specifications for street (with mechanical earth work) |
63 | PVC pipe63mm o/d |
64 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge) |
65 | 150mm i/d Sluice Valves flanged |
66 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. |
67 | Haudi (0.60 x 0.60 mtr) (per unit) |
68 | Dismantling Brick or flanged stone flooring without concrete based Streets as per CSR item no. 8.19 and dry brick edge on paving with the dismantled bricks including sand grounting, complete in all respects. |
69 | 63mm o/d |
70 | Providing proposed water connection to house hold up to wall with Providing MDPE pipe PN 16, 20 mm 2m and G.I Pipe ( as per IS 1239) B- Class, Premium make such as Jindal Hissar as approved by Engineer Incharge 15mm i/d=2.5 mtr, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete(On Proposed line) |
71 | Painting of exising Sign Board at water works site complete in all respects |
72 | Provision for bleaching powder or sodium chlorite for disinfection of water |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy