Repair Maintenance Of Centrifugal And Monoblock Pump Sets Submersible Pump Sets And Electric Control Panels Of Submersible Development Of Borewell Lt Panels And Internal Wiring Including Connected Items Of Water Suply Installations Of Cod Area 505 Ab, delhi-Delhi

Military Engineer Services-MES has published Repair Maintenance Of Centrifugal And Monoblock Pump Sets Submersible Pump Sets And Electric Control Panels Of Submersible Development Of Borewell Lt Panels And Internal Wiring Including Connected Items Of Water Suply Installations Of Cod Area 505 Ab. Submission Date for this Tender is 14-06-2022. Electrification Work Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

32302183
Corrigendum : Repair Maintenance Of Centrifugal And Monoblock Pump Sets Submersible Pump Sets And Electric Control Panels Of Submersible Development Of Borewell Lt Panels And Internal Wiring Including Connected Items Of Water Suply Installations Of Cod Area 505 Ab
Open Tender
Indian
Delhi
delhi
14-06-2022

Tender Details

Repair Maintenance Of Centrifugal And Monoblock Pump Sets Submersible Pump Sets And Electric Control Panels Of Submersible Development Of Borewell Lt Panels And Internal Wiring Including Connected Items Of Water Suply Installations Of Cod Area 505 Ab

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Jun-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-06-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
INR 44 Lakhs /-

BOQ Items

Name of Work:REPAIR MAINTENANCE OF CENTRIFUGAL AND MONOBLOCK PUMP SETSSUBMERSIBLEPUMP SETS AND ELECTRIC CONTROL PANELS OF SUBMERSIBLE , DEVELOPMENT OF BOREWELL, LT PANELS & INTERNAL WIRING INCLUDING CONNECTED ITEMS OF WATER SUPLY INSTALLATIONS OF COD AREA, 505 ABW, ME LINE, 17 SIKHLY, NARINA, NP-II 1811 PNR, ESD DEPOT AREA OF AGE W/S NO - I UNDER GE (U) WATER SUPPLY DELHI CANTT-10.
Sl. No. Item Description
1Disconnectingof electric connections from LT control panel and starter of submersible pump set of size 2 to 15 HP ,removing the pipe line connections from discharge side and taking down/out submersible pump set along with column pipe from bore well with the help of chain pully block including transportation to workshop for repairs and back , lowering the pump in bore well after repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing complete all as specified and as directed .
2Labour for Opening the submersible pump set for repairing, rewinding and assembling the pump set including insulating material of any size ofcapacity 2 to 15 HP complete all as specified and as directed by Engg-in-charge.(different make and size of copper winding and other spare parts will be measured under relevant items of this shedule as supply only.) Note :- Copper winding wire of appropriate gauge shall be measured and paid separetely
3Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable upto 2 to 15 HP capacity submersible pump set complete all as specified and as directed.
4Supply Only following spare parts for submersible pump set of capacity 2 HP to 15 HP.
5GM Bush.
6Rotor Sleeve.
7Water seal and cable seal
8Thrust bearing
9Revolving Disc
10CI Connection piece
11GM Sand Guard
12Sealing Ring
13CI upper Housing
14CI lower Housing
15Flange upper with stud and nut
16Flange lower with stud and nut
17Seal bush
18CI Motor Base
19Thrust plate
20Stainless steel coupling
21Coupling key
22Stud and nuts for connection piece
23T Bolt with Nut
24LNK Bolt SS
25Submersible cable joint
26CI Suction Chamber
27CI Stage bowl
28GM Impeller
29EPV Impeller
30EPV Stage Bowl
31GuideBush
32GM DOWL Bush
33SS DOWL Sleeve
34Inter ring
35CI DOWL Piece
36CI NRV body
37Impeller key
38SS pump shaft per stage
39pump sand guard
40SS Distance Sleeve
41EPV Defuser
42Hook bolt with nut
43GM NeckRing
44Mild steel stud with nut
45Wire mesh
46Drain plug
47Labour only for Rotor Sleeve turning and grinding
48Labour only for Remetling of Rotor, turning and balancing
49Labour only for Repairing of stator stamping
50Labour only for balancing of rotor
51Labour only for Remetling of GM impeller & turning
52M & L for Preperation to existing submersible pump set of capacity 2 to 15 HP and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed .
53Supply and fixing in replacement GI Nipple with flange welded, heavy duty 50 x 300 mm size complete all as specified and as directed.
54All as per serial item No 6.00 here-in-before but of size80 x 300 mm
55Supply Only GI column pipe, heavy grade, class "C", 50 mm bore of 3 metre length, heavy duty, flange welded on both ends complete all as specified and as directed .
56All as per serial item No 8.00 here-in-before but80 mm bore Note for 8.00 to 9 :- rate quoted for labour required is deemed to be included in item no. 1.
57Disconnectingof electric connections from LT control panel and starter of monoblock submersible pump set of size 2 to 10 HPvertical/ Horizontal ,removing the connections from discharge side and taking down/out mono block submersible pump setfrom well/sump/sewage well/Sewage treated tank with the help of chain pully block including transportation to workshop for repairs and back , lowering the pump in same placeafter repairs after replacement of rusted nuts, bolts, washers, rubber gasket etc including testing complete all as specified and as directed .
58Labour for Opening the mono block submersible pump set for repairing, rewinding and assembling the pump set including insulating material of any size ofcapacity 2 to 15 HP vertical/ Horizontalcomplete all as specified and as directed by Engg-in-charge.(different make and size of copper winding and other spare parts will be measured under relevant items of this shedule as supply only.) Note :- Copper winding wire of appropriate gauge shall be measured and paid separetely
59Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable for mono block submersible upto 2 to 10 HP complete all as specified and as directed.
60Supply Only following spare parts for mono block submersible pump set of capacity 2 HP to 10 HP.
61Bearing Bush
62Thrust Plate
63CI Impeller
64Thrust bearing
65Impeller key
66Impeller Nut
67Rubber Gasket
68O ring
69M Seal
70Oil Seal
71Oil
72Cable Kit Jointing
73Float Switch
74Labour only for Rotor Sleeve turning and grinding
75Labour only for balancing of rotor
76Supply and fixing in replacement submersible copper cable of size 2.5 Sq mm 3 core, 1100 Volts complete all as specified and as directed .
77All as per serial item No 14.00 here-in-before but cable of size 4 Sq mm 3 core , 1100 Volts .
78Supply and fixing in replacement Mild steel clamps in Mild steel flat of size 50mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 50mm bore column pipe complete all as specified and as directed.
79Supply and fixing in replacement Mild steel clamps in Mild steel flat of size 80 mm x 6 mm with including two Nos Mild steel nut and bolts suitable for 80mm bore column pipe complete all as specified and as directed.
80Supply and fixing in replacement M.S. Casing Cover, heavy duty, made out of Mild steel sheet not less than 6mm thick suitable for 200-300 mm bore pipe complete all as specified and as directed .
81Supply and fixing in replacement single phase preventor, type VSP-IIcomplete all as specified and as directed.
82Supply and fixing in replacement Amp Meter 0 to 100 Amp of size 96 mm x 96 mm, digital type complete all as specified and as directed.
83Supply and fixing in replacement Volt meter 0 to 500 Volts of size 96 x 96 mm digital type
84Supply and fixing in replacement analog type time switch FM 1/Quartz daily 240 volts, AC, 50 Hz code AUTS01ANA00complete all as specified and as directed
85S&F Star Delta electronic ST 100 Timer 3-30 Second duration, 160 V to 500 V
86Supply and fixing in replacement Indicating light RYG LED type(03 Nos each Set)complete all as specified and as directed .
87Supply & fixing , install testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
88Al bus bar with PVC sleeve suitable for 200 amps for phase & 200 Amp for neutral- 01Set.
89Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
90Ammeter Digital type 0-100Amps, with selector switch and CT"-1set
91Phase indicating lamps LED type ( red , yellow, blue) 01 set
92Incoming MCCB125 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No
93outgoing MCCB63 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No
94FASD Stater with ms sheet encloser ML 1.5 FASD-01 Nos
95Analog time switch -01 No
96Single phase preventer-01 No
97Extension/ development of borewell for drilling not less than 250 mm bore hole by DTHmethod to any depth below the ground level in any kind of rock/soil upto 100 mtr deep including disposal of surplus soil to a distance not exc 50 mtr away complete all as specified and as directed. Note : 1) In case of incountering rock prior to 30 mtr depth from ground level the decission of the Garrison Engineer for reboring shall be final and binding.Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shal vary accordingly.2) cost of transportation of DTH plant is included in the unit rate.
98Supplying, lowering & fixing into bore 200 mm dia MS casing pipe, heavy duty as per IS-4270, minimum 5.4 mm thick ERW having Duly welded both sides socketed ends ciomplete all as specified and as directed.
99Supplying, lowering & fixing into bore hole 200 mm dia MS casing pipe, heavy duty as per IS -4270 minimum 5.40 mm thick ERW slottedtube having 1.5 mm to 3mm slot having socketed ends at complete all as specified and as directed
100M&L for development of bore well of any capacity and size at the pressure 10 kg/sqcm to 15 kg/sqcm by diesel engine driven air compressor of capacity 620 cfm includiing air pipe and connected items to improve the yield of tube well complete all as specified and as directed.
101Supplying and packing pea gravel of size 3.00 mm to 6.00 mm around casing pipe complete all as specified and as directed.
102Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and Opening the electric induction motor of following capacity including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc taking down/out from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .Note:- Copper winding wire of approprioate guage will be measured in supply only
1035-15 HP
10420-30 HP
10540-50 HP
10660-75 HP
10790-105 HP
108Disconnecting and De-coupling the Centrifugal pump of following capacity from foundation after opening /cutting the rustednuts, bolts & Opening the centrifugal pump of following capacity, repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete etc including transporting the pump to workshop for repairand back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed. Note:- Spare Parts required shall be measured & paid spaerately.
1095-15 HP
11020-30 HP
11140-50 HP
11260-75 HP
11390-105 HP
114Supply and fixingin replacement of spare parts for Centrifugal pump of 5-15 HP Capacity.
115CI Impeller
116pump shaft
117CI Casing wear ring
118CI interstage ring
119CI stuffing box bush
120CI Gland Plate
121lentern ring
122eye bolt with nut
123CI Shaft sleeve
124Gasket Packing Sheet
125Gland packing champion (Both side)
126impeller key
127coupling key
128water liquid deflector
129CI bearing cartridge
130CI bearing plate
131MS Stud with nut
132Supply and fixingin replacement of spare parts for Centrifugal pump of 20-30 HP Capacity.
133CI Impeller
134pump shaft SS (AISI-410)
135Remetling of pump shaft,turning and balancing
136CI Shaft sleeve
137CI Casing wear ring
138CI interstage ring
139CI stuffing box bush
140CI Gland Plate
141lentern ring
142eye bolt with nut
143Gasket Packing Sheet
144Gland packing champion (Both side)
145impeller key
146coupling key
147water liquid deflector
148CI bearing cartridge
149CI bearing plate
150MS Stud with nut
151Supply and fixingin replacement of spare parts for Centrifugal pump of 40-50 HP Capacity.
152CI Impeller
153pump shaft SS (AISI-410)
154Remetling of pump shaft,turning and balancing
155CI Shaft sleeve
156CI Casing wear ring
157CI interstage ring
158CI stuffing box bush
159CI Gland Plate
160lentern ring
161eye bolt with nut
162Gasket Packing Sheet
163Gland packing champion (Both side)
164impeller key
165coupling key
166water liquid deflector
167CI bearing cartridge
168CI bearing plate
169MS Stud with nut
170Supply and fixingin replacement of spare parts for Centrifugal pump of 60-75 HP Capacity.
171CI Impeller
172pump shaft SS (AISI-410)
173Remetling of pump shaft,turning and balancing
174CI Shaft sleeve
175CI Casing wear ring
176CI interstage ring
177CI stuffing box bush
178CI Gland Plate
179lentern ring
180eye bolt with nut
181Gasket Packing Sheet
182Gland packing champion (Both side)
183impeller key
184coupling key
185water liquid deflector
186CI bearing cartridge
187CI bearing plate
188MS Stud with nut
189Supply and fixingin replacement of spare parts for Centrifugal pump of 90-105 HP Capacity.
190CI Impeller
191pump shaft SS (AISI-410)
192CI Shaft sleeve
193CI Casing wear ring
194CI interstage ring
195CI stuffing box bush
196CI Gland Plate
197lentern ring
198eye bolt with nut
199Gasket Packing Sheet
200Gland packing champion(Both side)
201impeller key
202coupling key
203water liquid deflector
204CI bearing cartridge
205CI bearing plate
206MS Stud with nut
207Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable upto 105 HP.
208Supplying and Fixing in replacement of Terminal Connection Plate of following capacity
20910-40 HP
21050-105 HP
211Supply and fixingspare tyre for couplingtype TC/P/011 after taking down/outas existing at site complete all as specified and as directed.
212Supply and fixingspare tyre for couplingtype TC/P/013 after taking down/outas existing at site complete all as specified and as directed.
213Supply and fixingspare tyre for couplingtype TC/P/014 after taking down/outas existing at site complete all as specified and as directed
214Supply and fixingspare tyre for couplingtype TC/P/015 after taking down/outas existing at site complete all as specified and as directed
215Supply and fixingspare tyre for couplingtype TC/P/019 after taking down/outas existing at site complete all as specified and as directed.
216Supply and Fixing in replacement of Ball Bearing 6305
217Supply and Fixing in replacement of Ball Bearing 6306
218Supply and Fixing in replacement of Ball Bearing 6307
219Supply and Fixing in replacement of Ball Bearing 6308
220Supply and Fixing in replacement of Ball Bearing 6309
221Supply and Fixing in replacement of Ball Bearing 6310
222Supply and Fixing in replacement of Ball Bearing 6312
223Supply and Fixing in replacement of Ball Bearing 6314
224Supply and fixingin replacement 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed
225Supply and fixingin replacement 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
226Supply and fixingin replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed
227Supply and fixingin replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed
228Supply and fixingin replacement 3 pole power contactor type ML-6,110 Amps,415 Volts, 50 HZ complete all as specified and as directed
229Supply and fixingin replacement 3 pole power contactor type ML-12, 200 Amps 415 Volts, 50 HZ complete all as specified and as directed.
230S & F in replacement of over load replay type ML 1.5, starter , relay range 10-16 Amp complete all as specified and as directed.
231S & F in replacement of over load relay typeML 2, starter , relay range 20-32 Amps complete all as specified and as directed.
232S & F in replacement of over load relay typeML 3, starter , relay range 28-42 Amps complete all as specified and as directed.
233S & F in replacement of over load relay typeMN 5 ,MNX relay range 45-75 Amps complete all as specified and as directed.
234S & F in replacement of over load relay typeMN 5 ,MNX relay range 66-110 Amps
235Material and labour for paintingTwo coat of synthetic enamelpaint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 10-105 HP upto NRV or sluice valve,andMS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed.
236Supply and Fixing in replacement MS base channel& angle of size as exists including cutting, welding andmaking hole including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
237Supplying , laying , jointing, welding and testing MS Pipe (Heavy class"C") IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position orlaying on floors for connectionsfor suction, to header andconnected to out going water main CI/DI/GI pipe line, forfollowing size including taking out the old unserviceable pipes :- Note:- MS Flangesincl fabrication work will be measured and paid separately.
23880mm dia
239100 mm dia
240150 mm dia
241supply and fixing in replacement of MS flange 80 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasketjoint of size80mm size
242supply and fixing in replacement of MS flange 100 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasketjoint of size100mm size
243Supply and fixing in replacement of MS flange 150 mm bore ,16mm thick duly welded with flange joint including nuts bolts ,washer ,Rubber or fiber board gasketjoint of size150mm size
244Supply and fixing jointing and testing of cast iron Non return valve without by pass arrangment swing type confirming to IS 5312 flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRVall as specified and as directed by Engineer-in-Charge.Note - Flanged joints complete withrubber jointing materail shall deemed to be included in the unit rate of this item
24580mm bore
246100mm bore
247150mmbore
248Supply and Fixing in replacement of CI Foot valve offollowing size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and as directed Note:- Flanged joints comlete with jointing material shall deemed to be included in the unit rate of this items.
24980mm bore
250100mm bore
251150mmbore
252Material and labour for PCC (1:2:4) type B-I(with 20 mm graded aggregate) as in coping, grouting, MS nut for motor base , finished even and smooth without using extra cement as on brick work/flooring complete including demilition of PCC complete all as specified and as directed
253Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia , 450 mm long complete all as specified and as directed.(including breaking of hard standing foundation)
254Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 7.5-30 HP complete all as specified and as directed
255Supply and Fixing in replacement of Vibration Pad with nuts, bolts and washers, for existing capacity of 40-75 HP complete all as specified and as directed.
256Supply and fixing in replacement PVC insulated multistranded copper conductor wire of 10 Sqmm size, single core, 1100 volts complete all as specified and as directed.
257All as per item no 76 here in before but of size 16 Sqmm
258All as per item no 76 here in before but of size 25 Sqmm
259All as per item no 76 here in before but of size 35 Sqmm
260Excavation in trenches not exc 1.5 metres wide and not exc 1.5 metres deep for pipe lines in soft/loose soil, getting out and levellling of bottom surface to required level complete all as specified and as directed
261Returning fillling in including spreding, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed
262Removing execavated material from site to a distance not exc 50 metres away and depositing where directed not exc 1.5 metres from the starting point complete all as specified and as directed
263Supplying and laying well burnt bricks sub class B for protection of cable complete all as specified and as directed
264M&L Jamuna Sand filling under and above the electrical cable for cable cushioning complete all as specified and as directed.
265S & F in replacement of LT XLPE cable from trenches/wall/ceilings and Supply ,laying jointing and testing LT XLPE under ground cable PVC insulated armoured heavy duty 1100 volts grade sheated25 sq mm 3.5 core, aluminium conductor including connection to panel at incoming and out going using aluminium lugs complete all as specified and as directed
266All as per item No 85 Here in before but 35 Sqmm
267M&L Galavanised iron strip 25x4 mm as earthing lead including connecting to earthing test point to the equipment to be earthed by means of nuts ,bult and washers complete all as specified and as directed
268M & L for heat shrinkable LT 1100V straight through joint suitabel for aluminium conductor cable of size 25 to 50 sqmm complete all as specified and as directed
269S & F Fully automatic stat delta motor starter of maximum motor output17.5 Hp of motor rating AC 3 duty 415V 50 Hz 3 phase, MN-16, relay range 9-15 Ampsincluding taking down old starter complte complete all as specified and as directed
270All as per item no 89 Here in before but 30 HP MN-25, relay range 14-23 Amps
271All as per item no 89 Here in before but 50 HP ML-3, relay range 28-42 Amps
272All as per item no 89 Here in before but 75 HP ML-4, relay range 45-75 Amps.
273S & F in replacement MCCB 600 to 630 Amps, 4 pole 415V,Adjustable type of breaking capacity 50 KA inlcuding linkand connecting to bus bars and cable endtermination with suitable lugs complete all as specified and as directed.
274All as per item No 93 here in before but MCCB 400Amps, 4 pole, 415 V, breaking capacity 36 KA
275All as per item No 93 here in before but MCCB 250Amps, 4 pole, 415 V, breaking capacity 36 KA
276All as per item No 93 here in before but MCCB 200Amps, 4 pole, 415 V, breaking capacity 36 KA
277All as per item No 93 here in before but MCCB 160, 4 pole, 415 V, breaking capacity 36 KA
278All as per item No 93 here in before but 3 pole MCCB125Amps,415V, breaking capacity 16 KA
279All as per item No 93 here in before but 3 pole MCCB 63Amps,415 V, breaking capacity 16 KA
280Taking down old unserviceable point wiring from existing conduit ( light fan , socket or powder) complete such as switches, ceiling rose, pendent holder and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc complete all as specified and as directed.
281Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches/sockets/fan regulator etc complete all as specified and as directed for the following :- (Note : The cost of modular type Metal boxes and modular accessories like cover plates will be included in quoted rate.)
282one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push.
283one socket outet point 5 amps on the same board.
284one socket outet point 5 amps on the independent board.
285All as per item no. 101 here in before but with 2.5 sqmm copper FRLS wire with 1.5 Sqmm FRLS copper earth wire
286Supply & fixing in replacement of switch piano, flush type single pole 1 way, 5 Amps complete all as specified and as directed.
287Supply & fixing in replacement of switch piano, flush type single pole 1 way, 15 Amps complete all as specified and as directed.
288Supply & fixing in replacement of socket outlet 6 Amp, 2 in 1,3 pin 5 Amps
289Supply & fixing in replacement of socket outlet 15 Amp, 2 in 1,3 pin 5 and 15 Amps
290Supply & fixing in replacement ofFan regulator step type, 120 watts,
291Supply and fixing in replacement of Ceiling rose, surfacebakelite 3 terminal, 240 volts, 5 Amps with back plate of 3 mm thickbakelite, laminated hylem sheet of appropriate size& MS box of suitable size complete all as specified and as directed.
292Supply and Fixing lamp holder,PVC/ Polycarbonate type with back plate suitable for batten fitting (angle /plain) complete all as specified and as directed
293Supply and fixing in replacement ofDistribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and as directed.
294Supply and fixing in replacement ofDistribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and as directed.
295Supply and fixing in replacement of MCB SP 16 to 32 Amps " C "Curve , 240 volts AC supply, capacity not less than 10 KA connection complete all as specified and as directed.
296Supply and fixing in replacement of MCBSPN 32 Amps " C "Curve , 240 volts AC supply, capacity not less than 10 KA connection complete all as specified and as directed.
297Supply and fixing ofLED tube fittings 20 Watt LUMILINE Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver connection completeall as specified and as directed
298Supply and fixing in replacement of Recessed Mountedwith PLUTO Neo PANEL 2X2 LED 42 Watt Environmental friendly, new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete all as specified and as directed
299Supply and fixingceilling fan 1200 mm sweep Single pole230V , 50Hz complete with fan regulator and down rodconnection completeall as specified and as directed
300S & F in replacement of 25 Watt LED post top New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source connection complete all as specified and as directed
301Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS14846 flanged ends drilled having stainless steelspindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluicevalve and removal from siteforthe follwing sizes complete all as specifiedand as directed
30280mm bore
303100mm bore
304150mmbore
305Supply and fixing in replacement 60 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07including making connections with GI pipe 0.6mtrangle braket fixing on wall and connectng to ceiling rose with apropriate wirecomplete all as specified and as directed .
306Supply and fixing in replacement 35 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07including making connections with GI pipe 0.6mtrangle braket fixing on wall and connectng to ceiling rose with apropriate wirecomplete all as specifiedand as directed .
307Supply & Fixing in replacement of PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade connection complete all as specified and as directed
308Supply only LED bulb of 9 watt
309S&F in replacement rotational moulded polythylene water storage tanks of capacity 500 ltr triple layercylindrical vertical with closed top hoisted and fixed in positionfor primingof centrifugalpump set complete all as specified and as directed in SSR part I
310M&L for fabrication(welding work ) of MS Header/ any size upto 300mmMS pipeat various pump house site for connection of pipe , arresting leakges on header complete all as specified and as directed
311Material and labourfor painting two coat of synthetic enamel paint as per existing pattern on pipe surface/header connectionincluding preparation of surfaces by scratching and removing the rust, red primer coat complete all as specified and as directed
312Supply & fixing in install testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 2.0 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
313Albus bar with PVC sleev suitable for 600 amps for phase & 400 Amp for neutral- 01Set.
314Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
315(c) Ammeter Digital type 0-600Amps, with selector switch and CT"-1set (set of three)
316Phase indicating lamps LED type ( red , yellow, blue) 01 set
317Incoming MCCB400 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
318outgoing MCCB250 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -02 No
319outgoing MCCB100 Amp 3 pole 16 KA with adjustable thermal and fixed magnetic release -04 No
320ML-1.5 Star Delta starter fully automatic suitable for 415V AC upto motor 10 HP with ON/OFF & Trip indication including sheet enclosure-01 No.
321Analog time switch 1 module-01 No
322Single phase preventer-01 No
323Supply & fixing in install testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 2.0 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
324Albus bar with PVC sleeve suitable for 400 amps for phase & 300 Amp for neutral- 01Set.
325Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
326Ammeter Digital type 0-400Amps, with selector switch and CT"-1set ( set of three)
327Phase indicating lamps LED type ( red , yellow, blue) 01 set
328Incoming MCCB250 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
329outgoing MCCB160 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -02 No
330outgoing MCCB63 Amp 3 pole 16 KA with adjustable thermal and fixed magnetic release -02 No
331ML-3 Star Delta starter fully automatic suitable for 415V AC upto motor 50 HP with ON/OFF & Trip indicationincluding sheet enclosure.-02 Nos
332ML-1.5 Star Delta starter fully automatic suitable for 415V AC upto motor 10 HP with ON/OFF & Trip indication including sheet enclosure. -01 Nos
333Single phase preventer-01 Nos
334Analog time switch 1 module-01 No
335Supply & fixing in install testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 2.0 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
336Albus bar with PVC sleeve suitable for 400 amps for phase & 300 Amp for neutral- 01Set.
337Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
338Ammeter Digital type 0-400Amps, with selector switch and CT"-1set ( set of three)
339Phase indicating lamps LED type ( red , yellow, blue) 01 set
340Incoming MCCB160 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
341outgoing MCCB63 Amp 4 pole 16 KA with adjustable thermal and fixed magnetic release -03 No
342ML-1.5 Star Delta starter fully automatic suitable for 415V AC upto motor 10 HP with ON/OFF & Trip indication including sheet enclosure.-03 Nos
343Analog time switch 1 module-03 Nos
344Single phase preventer-03 Nos
345Supply & fixing in install testing and commissioning of feeder pillar box ,indoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 2.0 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frameand four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned belowand having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc .
346Albus bar with PVC sleeve suitable for 400 amps for phase & 300 Amp for neutral- 01Set.
347Voltmeter,digital type 0- 500 volt,with selector switch - 01 set
348Ammeter Digital type 0-400Amps, with selector switch and CT"-1set ( set of three)
349Phase indicating lamps LED type ( red , yellow, blue) 01 set
350Incoming MCCB250 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -01 No
351outgoing MCCB160 Amp 4 pole 36 KA with adjustable thermal and fixed magnetic release -02 No
352outgoing MCCB100 Amp 3 pole 16 KA with adjustable thermal and fixed magnetic release -02 No
353ML-3 Star Delta starter fully automatic suitable for 415V AC upto motor 50 HP with ON/OFF & Trip indicationincluding sheet enclosure.-02 Nos
354Single phase preventer-02 Nos
355Supply and fixing &installation in replacement ofperforated MS cable tray of size 350x50x2mm including horizontal and vertical bends, prepared hanging systemand other accessories including painting of cable tray ofcomplete all as specified and as directed.
356M&L for DI flange fittingsof A/F Tee, D/FBendand DI flange SocketPiece of size 80 to 100mmdia bore Equal incluidng required cutting existing pipeconnection complete all as specified and as directed.
357Material and labour for Brick workwith sub class "B" bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) for pillar in Borewell complete all as specified and as directed
358An amount of Rs 133022.00 shall be deducted from BOQ on account of schedule of credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail