Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 11 Kv Sub Station In Judicial Archive Building Plot No. 841, Industrial Area, Phase Ii, Ut, Chandigarh. Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 1, chandigarh-Chandigarh

Chandigarh Administration Engineering Department has published Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 11 Kv Sub Station In Judicial Archive Building Plot No. 841, Industrial Area, Phase Ii, Ut, Chandigarh. Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 1. Submission Date for this Tender is 24-05-2022. Control Panel Tenders in chandigarh Chandigarh. Bidders can get complete Tender details and download the document.




Tender Notice

32262490
Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 11 Kv Sub Station In Judicial Archive Building Plot No. 841, Industrial Area, Phase Ii, Ut, Chandigarh. Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 1
Open Tender
Indian
Chandigarh
chandigarh
24-05-2022

Tender Details

Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 11 Kv Sub Station In Judicial Archive Building Plot No. 841, Industrial Area, Phase Ii, Ut, Chandigarh. Providing 120 Kvar 80 Kvar Apfc Automatic Power Factor Control Panel For 11 Kv Sub Station In Judicial Archive Building Plot No. 841, Industrial Area, Phase Ii, Ut, Chandigarh.

Key Value

Document Fees
Refer document
EMD
INR 8200.0 /-
Tender Value
INR 4.06 Lakhs /-

BOQ Items

Name of Work:- PROVIDING 120 KVAR/ 80 KVAR APFC (AUTOMATIC POWER FACTOR CONTROL) PANEL FOR 11 KV SUB STATION IN JUDICIAL ARCHIVE BUILDING PLOT NO. 841, INDUSTRIAL AREA, PHASE-II, UT, CHANDIGARH.
Sl. No. Item Description
1DSR Item No.5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2DSR Item No. 5.8 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
3DSR Item No. 4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
4200 mm width X 50 mm depth X 1.6 mm thickness
5Supply, fixing, connecting and testing of OEM Manufactured/ Manufactured by Channel Partner APFC Panel with 7% copper reactor of capacity 120 KVAR (Output) @ 440Vac. The stage ratings shall be 1 x 5 KVAR + 1 x 10 KVAR + 2 x 15 KVAR + 1 x 25 KVAR + 1 x 50 KVAR (525 VAC). The APFC Panel shall be (Indoor) type floor mounted, weather, (As per Complete Item No. 4 of the DNIT).
6Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors breakers etc. The exhaust fan shall be ON & OFF through Temperature Thermostat and backed by suitable rating MCB etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted alongwith the offer
7Supply, fixing, connecting and testing of OEM Manufactured/ Manufactured by Channel Partner APFC Panel with 7% copper reactor of capacity 80 KVAR (Output) @ 440Vac. The stage ratings shall be 1 x 5 KVAR + 1 x 10 KVAR + 1 x 15 KVAR + 2 x 25 KVAR (525 VAC). (As per Complete Item No. 5 of the DNIT).
8Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors breakers etc. The exhaust fan shall be ON & OFF through Temperature Thermostat and backed by suitable rating MCB etc. The capacitor banks should be of type tested design and temperature rise test report of the capacitor bank performed at an independent laboratory should be submitted alongwith the offer
9Supplying and laying of imperative commercial PVC flooring sheet highly durable (Brown woody color) of 2 mm thick made out of polyvinyl chloride PVC based material with suitable arrangement to be laid on existing floor including cost of smooth the surface with cement sand mixture for laying the same as per site requirement. The job includes the cost of labour and other petty material etc. as required to complete the job to the entire satisfaction of EIC.
10Supply and Laying of PVC Armored Aluminum conductor cable in existing pipe/trench. This also includes making connections, testing, commissioning, all labour and petty material required to complete the job. The cable should be ISI marked of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables/ Grandlay/ Certina make only. The job includes all labour and petty material required to complete the job to the entire satisfaction of the E.I.C of the work.
11150 mm sq. 3.5 core
12120 mm sq. 3.5 core
13Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.
14Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells / Crompton / Bajaj/ Orient Make
15Supply and erection of 14 GMS sheet frame of suitable size for erection of exhaust fan.The hole should be suitable required size for exhaust fan shall be cut from the centre of the sheet duly fixed on existing M.S. glazing/ ventilator.The Exhaust fan frame shall be painted on both sides with superior quality paint after one coat of primer.The job includes the cost of 2 Nos. M.S. strips of 25 x 6mm for proper holding the Exhaust fan and other petty material required to complete the job to the entire satisfaction of Engineer In Charge.
16Suitable for 15” Exhaust Fan.
17S/E of rubber mat of size 6’x 3’ x 12’mm thick (ISI mark) wide superior quality and of approved make as approved by the Engineer in charge to be laid on floor in HT room in front of panels and transformers.