}

Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs And Pipe Line Extension At Ward No.3 Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs , Pathanamthitta-Kerala

Kerala Water Authority-KWA has published Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs And Pipe Line Extension At Ward No.3 Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs . Submission Date for this Tender is 11-03-2022. Pipe Laying Tenders in Pathanamthitta Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

31320035
Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs And Pipe Line Extension At Ward No.3 Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs
Open Tender
Indian
Kerala
Pathanamthitta
11-03-2022

Tender Details

Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs And Pipe Line Extension At Ward No.3 Jal Jeevan Mission 2021-22- Anicadu Grama Panchayath - Sc.St Habitations Coverage Under Jjm- Providing Fhtcs And Pipe Line Extension At Ward No.3

Key Value

Document Fees
INR 2800 /-
EMD
INR 50000.0 /-
Tender Value
INR 45.21 Lakhs /-

BOQ Items

Work Name:Jal Jeevan Mission 2021-22:- Anicadu Grama panchayath -SC/ST Habitations coverage under JJM- Providing FHTCs and Pipe line extension at Ward No.3
Sl. No. Item Description
1App-A- Pipe line extension-Part 1- Working charges
2Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
3Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
4Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of so
5Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :" Ordinary Rock
6"Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Medium Rock (blasting prohibited)
7"Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : HardRock(Blasting Prohibited)
8Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals.
9Fencing 1.50m high with two rows ofcasuarina poles (girth 15cm to 24cm) tied with coir yarn on verticalcasuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
10Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 90 mm nominal outer dia pipes."
11Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 80 mm dia nominal bore
12Cutting and Grinding of 80mm (ID) G.I pipes for making bends and other specials by gas cutting including cost of gas,all labour and hire charges of tools etc complete:
13Welding 80 mm (ID) G.I pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc complete
14Fabricating MS flanges of diameter 80 mm using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates.
15Providing flanged joints to double flanged G.I./C.I./ D.I pipes and specials, including testing of joints:up to 80 mm diameter pipe
16Providing interconnection from the existing 50 mmto 110/100 mmPVC./GI/CI/AC pipe line with newly laid 80/90 mm PVC./GI/CI/AC pipe with TEE and suitable specialsby jointing with solvent cement, including cost of materials,necessary earth work excavation , labour charges etc.complete as per directions.(TEE PORTION ONLY)
17Jointing 80/90 mm AC/PVC/DI/GI pipes laid to lines and levels in the trenches using CID/CIR. detachable or any available type of joints after cleaning the ends, centering the pipes inserting the joints and tightening including conveying the materials within initial lead and other sundries etc. complete to make a water tight joint capable to withstand the required pressure (including cost of CID/CIR Joint).
18Supplying, Conveying and fixing 100 mm CI PE sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. including the cost of valve (the tail pieces if required will be paid separately) : Class IIConforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6.
19Supply of 100mm CID joint sets for valve fixing (Joining charge including valve fixing)
20Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
21Supplying and providing good quality 20/15mm CI Air valve in distribution main of 75 mm to 200mm pipe, fixing in suitable place including cost of MS Saddle piece etc. includingcost of 20mm GI/ Schedule 80mm ASTM/UPVC pipe average 3.00m, air valve, earth work excavation, .hire for tools and all other incidental charges , earth work excavation, labour chargesetc.. complete as per directions.
22Providing protection tube to the valve using 160mm PVC pipe 6kg/cm2 including labour charges for earth work excavation, other incidental charges etc. as per direction.
23Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
24Reinstate the existing house/Tap connection of 20mm (3/4 inch)with 15mm (1/2 inch) water meter from existing mains, up to a length of 5m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / Brass specials viz. brass ferrule, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of trench in average cross section 0.3m x 0.75m for laying connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour chargesand excluding charges for cutting the concrete / tarred / bituminous roads and as per the directions of the department officers.
25App-A-Pipe line extension-Part 2- Cost of Pipes
26Supplying 90mm PVC 10 kg/cm2 pipe and specials as relevant IS specification
27Supplying 80mm GI pipe (Medium) and specials as relevant IS specification
28App-B-Providing House connection
29Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
30Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
31Providing 20mm (3/4 inch) house connection with 15mm(1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow,MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, includingthe cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
32Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule,GM full way wheel valve, Elbow,MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, includingthe cost of tested Class B Multijet water meter and weather with ISI mark resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
33Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains from 150mm to 200mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule,GM full way wheel valve, Elbow,MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, includingthe cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
34Providing additional length of house connection pipe using25mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.
35Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
36Providing 15mm PVC Tap in the water meter assembly for 20mm connection, using 25mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
37Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
38Providing Geo Tagging for House connections as per JJM Norms.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail