}

Supply, Installation, Testing And Commissioning Of Fire Detection System At Sari Hospital, Sports Complex At Jalpaiguri.- 1 Supply, Installation, Testing & Commisioning Of Main Fire Alarm Control Panel: Microprocessor Based Intelligent Addres, jalpaiguri-West Bengal

Public Works Department-PWD has published Supply, Installation, Testing And Commissioning Of Fire Detection System At Sari Hospital, Sports Complex At Jalpaiguri.- 1 Supply, Installation, Testing & Commisioning Of Main Fire Alarm Control Panel: Microprocessor Based Intelligent Addres. Submission Date for this Tender is 21-02-2022. Storage Chests and Cabinets and Trunks Tenders in jalpaiguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

30846611
Corrigendum : Supply, Installation, Testing And Commissioning Of Fire Detection System At Sari Hospital, Sports Complex At Jalpaiguri.- 1 Supply, Installation, Testing & Commisioning Of Main Fire Alarm Control Panel: Microprocessor Based Intelligent Addres
Open Tender
Indian
West Bengal
jalpaiguri
21-02-2022

Tender Details

Supply, Installation, Testing And Commissioning Of Fire Detection System At Sari Hospital, Sports Complex At Jalpaiguri.- 1 Supply, Installation, Testing & Commisioning Of Main Fire Alarm Control Panel: Microprocessor Based Intelligent Addressable Fire Alarm Panel. Capacity Of The Loops Should Be Minimum 125 Detectors And Device. Addressability Of The Intelligent Panel Shall Be Analog Addresable So As To Consume Minimum Time Of Addressing The System With Detectors And Devices . The Intelligent Panel Shall Be Able To Give Pin Point Location Of All Fire / Fault Conditions. All The Multicriteria Detectors As Applicable For Various Areas Based On Application And Design Considerations Shall Be Fitted On Loop Along With Loop Powered Alarm Devices; Mcps And Input / Output Modules . The Panel Shall Have In Built Rectifier, Loop Cards, Provision For External, Lcd Unit To Indicate Fire / Fault Signal With Address. 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts Sealed Lead Acid Batteries Sufficient For 24 Hours Normal Working And Then Be Capable Of Operating The System For 2 Hours During An Emergency Conditions As Required. The Panel Should Be Capable Of Taking Minimum 1000 Addressable Detector And Devices. ( Approval Standards:En54 / Vds / Ul Certification ) ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) . 2 Supply, Installation, Testing & Commisioning Of Analog Addressable Intelligent Multisensor Detector Complete With All Accessories Like Base Plate Etc. ( Vds / Ul / Ertl / Lpcb / Fm Approved ) Withinbuilt Optical Smoke Sensors As Well As Additional Heat Detector Sensor With Decentralise Intelligence, Soft Addressable Photothermal Type With Inbuilt Fault Isolatoras Per Nfpa Style 7 Wiring Complete With Base Havingip As Per Recommended Standard. ( Note : Detectors Without Built-In Fault Isolator Is Also Acceptable But In Such Case The Contractor Shall Provide One Independent Fault Isolator Module For Every Group Ofaddressable Devices ( Numbers Of Addressable Devices In A Group Will Be As Per Latest Recommended Standards ) Without Any Additional Cost ) . ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) 3 Supply, Installation, Testing & Commisioning Of Addressable Manual Call Point Complete With All Accessories Like Base Plate Etc. ( Vds / Ul / Ertl / Lpcb / Fm Approved ) Soft Addressable Type With In Built Fault Isolatoras Per Nfpa Style 7 Wiring Complete Asrequired. ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) 4 Supply, Installation, Testing & Commissioning Of Addressable Loop Powered Hooter Complete With All Accessories Like Base Plate Etc. ( Sound Output Of Minimum 90 Db ) Cum Strobe ( Strength Of Light 10 Cd ) Complete With Inbuilt Isolator & Ip65 Base And ( Vds / Ul / Ertl / Lpcb / Fm Approved ) Approved. ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) Note : Hooter Must Be Addressable By Itself Or By Using Control Module.If Loop Power Hooter Is Not Used, Separate Wiring From Control Panel Upto The The Hooter Will Be In Contractor Scope Without Any Extra Cost. 5 Supply, Installation, Testing & Commissioning Of Addressable Transponder / Monitor Modules Complete With All Accessories Like Base Plate Etc. ( Vds / Ul / Ertl / Lpcb / Fm Approved ) For Monitoring Flow Switches / Fire Exit Doors / Ahu / Liftetc Complete As Required. ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) 6 Supply, Installation, Testing & Commissioning Of Addressable Relay ( 24V Dc / Ac, 220V Dc / Ac ) Modules Complete With All Accessories Like Base Plate Etc. ( Vds / Ul / Ertl / Lpcb / Fm Approved ) For Switching / Integration Of Lift / Ahu Etc Complete As Required. ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) 7 Supplying, Installation, Testing And Commissioning Of Led Type Response Indicator ( Vds / Ul / Ertl / Lpcb / Fm Approved ) Having 2 Nos. Red Coloured Led Lamps Including Connections Etc. ( Approved Make: Esser / Honeywell / Johnson Controls / Notifer / Securiton / Cease Fire / Siemens ) 8 Supply, Installation, Testing & Commissioning Of 240 Watt Power Amplifier With And S / F Gooseneck Microphone ( Make:Honeywell / Bose / Bosch / Ahuja ) 9 Supply, Installation, Testing & Commissioning 6 Watt Celing Mounted Speaker Along With Necessary Accessories ( Make: Honeywell / Bose / Bosch / Ahuja ) 10 Supply And Laying Of Speaker Cable In Pvc Rigid Conduit ( Make: Precision / Akg / Polycab ) On Wall Or Ceiling, Incl. S / F Pvc Rigid Conduit, Necy. Fittings Etc. And Mending Good Damages To Building Works ( Make:- Krammer / Finolex / Extron / Similar ) As Per Direction Of Eic. 11 Supply & Laying Of 2 Core 1.5 Sq.Mm Frls Shielded Copper Cable ( For Loop ) ( Make. Kei / Havells / Rr Kabel / Polycab ) With 20 Mm Nb Pvc Rigid Conduit Pipe ( Make: Precision / Akg / Polycab ) On The Surface Of The Wall As Per Direction Of Eic. 12 Supplying And Fixing Of 19 Mm Dia & 3 Mm Thick Pvc Rigid Conduit ( Precision / Similar Type ) Complete With Fittings As Necy. Under Ceiling / Beam, Bound With 22 Swg Gi Binding Wire Incl. Supplying And Drawing 1X18 Swg Gi Wire As Fish Wire Inside The Pipes As Per Gs. 13 Sitc Of 40Mm Widthdanger Radium Self Glowing Self Adhesive Tape Bopp. Red / Greenzebra Colouring. ( 1Coil=10 Mtr ) ( Make: Supreme / Creation / Polite Or Equivalent ) As Per Eic. 14 Supply.Installation, Testing& Comissioning Of 1Kva Offline Ups, Pure Sine Wavw Output On Ups ( Inverter ) Mode With 15 Mins Battery Backup At Rated Load ( Make-Apc / Microtek / Numeric ) 15 S& Delivery Of Infrared Type Thermal Scanner ( Make:Fluke 59 Max Digital Infrared Thermometer -30°C To 350°C ) 16 S&F240 Vone Number 5A Flush Type Plug Socket And One Number 15A Flush Type Plug Socketwith Separete Onenumber5a Piano Key Type Switch And One Number 15A Piano Key Type Switch On Sheet Metal Box With Bakelite Top Cover. ( Anchor Make ) As Per Gs. 17 Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire ( Brand Approved By Eic ) In 20Mm Size Pvc Rigid Conduit Fr ( Precision Make ) Incl. Necy. Fittings As Required [ Equivalet To Pwd / Gs Page: E-14 Item: E / 1 / A ] 18 2X36 / 0.3 ( 2.5 Sqmm ) + 1X22 / 0.3 ( 1.5 Sqmm ) As Ecc. 19 Tests:1. The System Shall Be Tested And Commissioned By A Qualified Competent, Trained Engineer Or Technician Authorized By The Manufacturer Of The Fire Alarm Equipment To Technically Supervise And Participate During All Of The Adjustments And Tests For The System. 2. Before Energizing The Cables And Wires, Check For Correct Connections And Test For Short Circuits, Ground Faults, Continuity, And Insulation And Other Tests As Per Above Standardsmust Be Done. 3. All The Test Should Be Done With CompanyS Own Cost. 20 Terms And Conditionthe Agency Must Procure The Materials From The Manufacturer / Oem Or From Their Authorised Sales Channel So That The Standard Warranty / Support Of The Manufacturer / Oem Becomes Applicable To The Products To Be Delivered And Installed By Them.Documents That Authenticates Such Procurement From The Manufacturer / Oem Or From Their Authorized Sales Channel And Standard Warranty / Support Should Be Sent From The E-Mail Of The Manufacturer / Oem / Authorized Sales Channel To The E-Mail Of Engineer-In-Charge And Hard Copy Of It To Be Submitted During Execution, Of Work / Submission Of Bill.If Any Refurbished Material Is Supplied And Installed, Penal Action Will Be Taken As Per Existing Rules.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2022 NIQ No. WBPWD/EE/JED/NIQ 40e/Q of 2021-22. Date 14-02-2022
2 15-Feb-2022 NIQ No. WBPWD/EE/JED/NIQ 40e/Q of 2021-22 and Tender Id No. 2022_WBPWD_362349_1. Date 21-02-2022

Key Value

Document Fees
Refer document
EMD
INR 36286.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail