Municipal Adminitration And Water Supply Department-MAAWSD has published Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone. Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone.. Submission Date for this Tender is 10-02-2022. Building Work Tenders in Coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

30843088
Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone. Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone.
Open Tender
Indian
Tamil Nadu
Coimbatore
10-02-2022

Tender Details

Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone. Construction Of Urban Health Wellness Centre Uhwc At Iyyer Layout In Ward No. 62 East Zone.

Key Value

Document Fees
Refer document
EMD
INR 25000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work : Constructionof Urban Health Wellness Centre (UHWC)at Iyyer Layoutin Ward No.62 East Zone.Roc. No. 9680 / 2021 / MD3
Sl. No. Item Description
1Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
2Footing
3Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
4Refilling with excavated earth in layers of 30 cm watered well rammed and consolidatred conforming to standard specification including labour charges as directed by Engineer incharge
5Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
6Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
7Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
8For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc
9For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
10M-20 CONCRETE - Providing and laying in position, standarised design mix M-20 Grade using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350Kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.70 cu.m.) 940.50Kg of 20mm machine crushed stone jelly and with about (2.80 cu.m.) 462.00Kg of 10-12mm machine crushed jelly and with about (4.25 cu.m.) 701.25Kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever neccessary without clambing extra, etc. complete complying with standard specification and as directed by the departmental officers. the coarse and fine aggregates to be used should comply with the requierments of IS 383- 2016. (No separate payment will be made by the department for the exces usage of materials as per design mix.) (SI No 81)
11Foundation
12Ground Floor
13Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
14Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"x43/8"x 2 3/4" including finishing, curing, etc., complete complying with standard specification.
15Ground Floor
16Brick Partition Walls using II class ground moulded chamber bricks of size 9"x43/8"x 23/4" in C.M 1:3 using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm
17Ground Floor
18Plastering with cement mortar 1:3:10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
19Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
20Dadooing Supplying and laying in flooring with fully polished Sinthetic Grey colour Granite stone of 10mm thick (average) of 2" X 1" in size laid in cement mortar 1:2 - 20 mm thick & pointed with same colour of cement etc., complete as per standard specification
21Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
22Laying the Flooring with Anti skid coloured ceramic tiles of sizes 305mm x305mm x 6mm size of approved make and quality and colour l Set in cement mortar 1:3 (one cement ,three sand) over 20 mm base layer plastering and pointing with white cement neatly as directed.
23Dadooing walls with Glazed tiles of sizes 305mm x 200mm x 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
24Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
25Supplying & fixing door shutters for Mediun Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of threee coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
26Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification.
27UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
28UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work(PWD SOR Pg. No. 65)
29Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere
30Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
31Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete PWD SOR Pg. No. 63 Sl.No. 239
32Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being "32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
33Plumbing Works
34Providing & fixing PVC RAIN WATER DOWN FALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes, Bemds, other clamps, screws nails etc., complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm](D)
35Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.(D)
36110mm dia pipe
37Supplying and fixing of 1000 litters capacity PVC tank of approved quality including cost of all materials like tank fittings, lead .lift, errection etc complete.
38Supplying and fixing in position first quality and approved variety of Gun Metal Gate Valve (Heavy type ) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of G.I.Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements. (D)
3925mm Gun Metal Valve
4032mm Gun Metal Valve
41Suppling and fixing in position 15mm.diameter brass / C.P screw down tap / pillar tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac, thread etc.complying with standard specifications and including cutting and threading wherever necessary (D)
42SD Tap
43Pillar Tap
44P.V.C. Pipes (10Kg/SqCm) Supplying laying and jointing P.V.C pipes (10Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges.(D)
4525mm dia Pipe
4632mm dia Pipe
47Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
48COUPLER
4925mm dia Pipe
5032mm dia Pipe
51ELBOW
5225mm dia Pipe
5332mm dia Pipe
54BEND
5525mm dia Pipe
5632mm dia Pipe
57TEE
5825mm dia Pipe
5932mm dia Pipe
60End Cap
6125mm dia Pipe
6232mm dia Pipe
63REDUCER
6425 mm x 20 mm
6532 mm x 25 mm
66REDUCER TEE
6725 mm x 20 mm
6832 mm x 25 mm
69REDUCER ELBOW
7025 mm x 20 mm
7132 mm x 25 mm
72JET NIPPLE
7325mm dia Pipe
7432mm dia Pipe
75Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).(D)
76PVC Elbow
77110mm dia
78PVC Elbow with Door
79110mm dia
80PVC Tee
81110mm dia
82PVC Tee with Single Door
83110mm dia
84Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications (D)
85Supplying and fixing in position 15mm dia C.P.Shower rose & stop cock of approved make confirming to IS specifications and qulity including cost of Shellac thread etc. complying with standard specification.
86Stop Cock
87Supplying and fixing in position Indian make bewelled edge mirror of size 600 x 450mm quality including cost of Rawal plugs, brass screws. etc. complying with standard specification.(D)
88Supplying and fixing best approved quality Brass C.P / Al anodised Towel rail 600mm. long and 20mm Diameter with brackets of same material including cost of Teak-Wood plugs and C.P.Screws etc., complete complying with standard specifications(D)
89Providing rain water harvesting using 3 nos.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 nos. of 6mm dia MS rod vertically and 3 nos. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm
90Supplying and fixing in position C.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.(D)
91Supplying and fixing in position european water closet of size 580 X 440mm, white glazed earthen ware of approved quality with "P" trap or "S" trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brickjelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. . (D)
92White EWC
93Supply and fixing of PVC. Nahini / Floor Trap with stainless Steel Gratings- 100 mm x 75 mm including all charges etc, complete as per standard specification.(D)
94Borewell
95Investigation charges for Geophysical survey finding of yield to the point drilling of Borewell for all etc., complete
96Drilling of 125mm (4 1/2”) nominal Dia vertical borewells anywhere in Tamilnadu in all formations, suitable for down the hole hammer drilling such as medium hard rock to hard rock formation, consolidated formation etc. and drilling over burden to a Dia not less than 200mm including insertion of 165 mm PVC casing pipe, couplings caps and other relevant materials required up to the depth as directed by the Engineer or his representative including grouting of cement 25kg (minimum) up to the depth of over burden are including borewell development flushing of borewell at a pressure 7kg/cm2 (100 lb. per square inch) including yield test, crew charges, cost of consumables, transportation charges of casing pipes and all other materials including assembling complete to the satisfaction of the Engineer and as stipulated in the technical specification. The entire works should be carried out as per IS 2800 Part I & II / 1979. Finished Dia of borewells shall not be less than 145mm
97Upto 60m depth
98Supply and delivery of clear water vertical wet type submersible pump suitable for 150mm Dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continues rated two pole suitable wet type vertical squirrel cage induction motor as per IS 9283/1995 and as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % ( PAGE 98) (50 Lpm X 125 m )
99Labour Charges for the erection of Submersible pump set in borewell including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, and erection of panel board consisting of TPICN switches starter voltmeter, Ammeter, three point (indicating) lamps capacitor single phasing preventor and laying and jointing the cable and twin earthing for etc., Complete and testing the pump set and trail run for 10 days.(pg287)
100Supply and Delivery of 150mmdia PVC casing Pipes including cost and conveyance of materials and Labour charges etc. complete as per standard. specifications
101150mm Dia PVC Casing Pipe(pg22)
102Supply and delivery of 3 phase panel board star delta with two level guard and auto start to suitable for 5 HP submersible pump set etc. Complete(pg110)
103Supplying delivery of G.I and PVC Pipes and specials of approved quality and best verity of B Class pipe including cost conveyance of materials to work site etc., complete.
10450mm Dia G.I Pipe
10550mm Dia G.I Coupling
10650mm Dia G.I Elbow
10750mm Dia G.I Union
10850mm Dia Non Return valve
109Borewell Clamp set
110Borewell Cover Plate
11140mm Dia PVC pipe
11240 mm Dia PVC Coupling
11340 mm Dia PVC Elbow
11440 mm Dia PVC Bend
11540 mm Dia PVC Reducer 50 x 40 mm
116Supply and delivery of PVC includes and sheeted 3 core flat type 4.00sq.mm castle conformists
117Electrical Works - Panels - Light Fixtures
118Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete SD 131
119Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete (SD 142)
120Supply an fixing o 6way SPDB of 16A /way with 16ADP switch with metal clad of 500V with fuse and neutral (side handle) on suitable angle iron frame work with trunking box MS cableen try box with PWD earthing (SD 153)
121Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 57)
122Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed fan point (for electronic regulator) SD 24
123Panels - MCB Distribution Board
1244 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4No. of outgoings ways - 12 PWD SOR 2021-22 Pg.no. 136 Sl.No. 16.1.a
125Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with doubledoor (metal) 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall andmaking good of the concealed portion with earth connection only. The MCB DB and MCB"s should be with ISImark (like standard make) (SD167)
126Supply and fixing of 32A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only (SD164)
127Air Conditioner(AC) - Supply and Installation of Air Contioner with Copper Coil
1281.5 TR Split Type AC Unit
129Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
130Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit)
131Supply and fixing of MS stand for fixing outdoor unit
132Wiring
133Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point. (SD 24)
134Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.)(SD 26)
135Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch (two way) with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC straircase light point (SD 27)
136Supply and run off 2 of 2.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 55)
137Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable MS Box in flush with wall and covered with 3 mm thick hylem sheet(SD 138)
138Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 57)
139EARTHING
140Earthing as per the ISI specification with an earth electrode of 2.10 metre Class "B" GI pipe of dia not less than40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements withnecessary masonry work and with 38mm RCC cover slab for the brick masonry (SD233)
141Supply and run of 1 of No.8 SWG GI wire for earth connection (SD74)
142Supply and fixing of 18W LED 3000K Square type resessed fiiitng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling (SI NO : 16) ELECTRICAL SOR
143LIGHT FIXTURES
144Supply and fixing of single box type 4"36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tubewith PVC unsheathed Copper leads from terminals to the fitting (SD - 87)
145Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K-Lite) suitable for 11W CFL (SD83)
146Supply and fixing of 1200mm (48")sweep AC ceiling fan complete with stepped electronic 300W regulator with the existing down rod on the existing clamps. (SD 110)
147Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW Box (SD 136)
148Add :- GST @ 12%