Indian Oil Corporation Limited-IOCL has published Pwrjt21069 / Repair, Renovation, Foundation And Display Panel Jobs In Centre Of Xpertise At Wrpl, Gauridad. Submission Date for this Tender is 28-02-2022. Foundation Work Tenders in gauridad Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Feb-2022 | Date Corrigendum-I | Date | 21-02-2022 |
2 | 22-Feb-2022 | Date Corrigendum-II | Date | 28-02-2022 |
Sl. No. | Item Description |
1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] : |
2 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge] |
4 | Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] |
5 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
6 | Of area 3.0 SQM & below Of area 3.0 sq. metres and below |
7 | Of area beyond 3.0 SQM Of area beyond 3.0 sq. metres |
8 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in : |
9 | Rolled Steel Joists Rolled Steel Joists |
10 | Channels, angles, tees and flats Channels, angles, tees and flats |
11 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead : |
12 | For thickness of tile 10-25 mm For thickness of tiles 10 mm to 25 mm |
13 | EARTHWORK : |
14 | Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge. |
15 | Pipe/Cable Trench-In all kinds of soil: Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge : |
16 | Trench depth upto 1.5m: Trench depth upto 1.5m : |
17 | Pipe/Cable dia = 80mm Pipes, cables etc. not exceeding 80 mm dia. |
18 | Pipe/Cable dia > 80mm & = 300mm Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
19 | CONCRETE WORK : |
20 | PCC-Up to Plinth Level: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
21 | 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources] |
22 | PCC-Up to V Floor Level: Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
23 | 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources] |
24 | Centering & Shuttering: Centering and shuttering including strutting, propping etc. and removal of formwork for : |
25 | Foundations, footings, bases for columns Foundations, footings, bases for columns |
26 | REINFORCED CEMENT CONCRETE : |
27 | RCC-Upto Plinth Level: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
28 | 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources] |
29 | RCC in Superstructure-Walls & Columns: Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement, with : |
30 | 1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources] |
31 | MASONRY WORK : |
32 | Brickwork (Non Modular)-In foundation & plinth: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : |
33 | In CM 1:4 Cement mortar 1:4 (1 cement : 4 coarse sand) |
34 | Brickwork (Modular)-In foundation & plinth: Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in : |
35 | In CM 1:4 Cement mortar 1:4 (1 cement : 4 coarse sand) |
36 | Random rubble masonry in foundation & plinth: Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : |
37 | In CM 1:6 Cement mortar 1:6 (1 cement : 6 coarse sand) |
38 | SS butt hinges: Providing and fixing IS:12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
39 | 125x64x1.90 mm |
40 | 75x47x1.80 mm |
41 | Magnetic catcher: Providing and fixing magnetic catcher of approved quality in cupboard/ wardrobe shutters, including fixing with necessary screws etc. complete : |
42 | Double strip (horizontal type) |
43 | Pre-laminated fibre board in shelves: Providing and fixing Pre-laminated medium density fibre board IS 14587:1998 marked, with one side decorative lamination and other side balancing lamination Grade-I (exterior grade), in shelves with screws and fittings wherever required, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand. [Note: Fittings to be paid separately] : |
44 | 18mm thick |
45 | Bright/matt finished SS handles: Providing and fixing bright/ matt finished Stainless Steel handles of approved quality & make with necessary SS screws etc. all complete as per direction of the Engineer-in-Charge : |
46 | 200 mm (Fancy Handle) |
47 | 75 mm |
48 | Soft closing spring hinges (SS) :Providing and fixing stainless steel soft closing spring hinges at zero degree hinges (hydraulic type) of approved make/ brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of the Engineer-in-Charge. |
49 | Wooden framework for full/low height partition, etc.: Providing and fixing in position approved first class seasoned Mirindi/ Kail Wood framework for full height/ low height partition, wall cladding, suspended ceiling etc. placed at center-to-center spacing specified below, fixed to floor/ walls and slab/ ceiling with approved dash fasteners/ anchor bolts (mild steel, zinc plated) including necessary hardware and making provision for housing electrical, Telephone & LAN conduits etc. and painting the framework with 2 coats of approved fire retardant paint (Conforming to BS-476, Part-70), anti-termite, wood borer treatment (as per manufacturer"s recommendation) complete as per drawings, specification and as directed by the Engineer-in-Charge. [Note : Net area after deduction of area of door shutter including wooden frame and glass including wooden beading shall be considered for payment]. |
50 | Frame of size 50 mm x 25 mm placed at 450 mm centre to centre or part thereof bothways. |
51 | SS finished tower bolts :Providing and fixing approved stainless steel finished tower bolts (barrel type) 10 mm diameter & 200 mm long with screws etc. complete as per drawings, specification and directions of the Engineer-in-Charge. |
52 | Cylindrical lock :Providing and fixing approved cylindrical lock of "ACME KASA" or equivalent with required colour or shade with nuts and screws etc. complete as per drawings, specifications and directions of the Engineer-in-Charge. |
53 | STEEL WORK : |
54 | Structural steel work (single section):Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
55 | Panelling/Glazing in Shutter: Providing and fixing panelling or panelling & glazing for panelled or panelled & glazed shutters (25 mm to 40 mm thick shutters) for doors, windows and clerestory windows [Note: Area of opening for Panel inserts/ Glass panes excluding portion inside grooves or rebates shall be measured for payment] : |
56 | Float Glass Panes - 5.5 mm thick (weigth not less than 12.5 Kg/SQM) |
57 | ACP Cladding Work :Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: (A) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (B) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based fluoropolymer resin coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (C) The fastening brackets of Aluminium alloy 6005 T5/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in square metre up to two decimal places. |
58 | Reinforcement for RCC-Upto plinth Level: SSteel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level : |
59 | TMT Bars (Fe-500D grade or more) Thermo-Mechanically Treated bars of grade Fe-500D or more |
60 | FINISHING : |
61 | 12mm plaster (in fine sand): 12 mm cement plaster of mix : |
62 | 1:4 (1 cement : 4 fine sand) |
63 | Premium acrylic emulsion paint (Interior Grade): Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : |
64 | Two coats |
65 | White cement based putty on wall:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
66 | Varnishing with: Varnishing with varnish of approved brand and manufacture : |
67 | Melamine polishing on wood work (one or more coat). |
68 | False Ceiling-G.I. Tiles: Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sq.m., both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using G.I. slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia. and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along main "T", bottom exposed width of 24 mm of all "T"-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by the Engineer-in-Charge : |
69 | Gypsum Tile (PVC Laminated & Square Edge) :12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS:2095 (Part-1) and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
70 | PANELING WITH LAMINATE FINISH Providing and Fixing laminate Panellingon RCC column, Brick wall or any other surface as per instruction of Architect/EIC, made out of 12mm thick BWR ply having 1mm thick approved / make laminate finished on all exposd surface as per detail drawing and instructions of the Architect / EIC etc complete inclusive of tools tackles, labour, hardware etc. ( Mode of Measurement : legnth & width as per drawing ) |
71 | Providing & fixingapproved make & design wall paper fixed with adhesive including all tools, tackles, labour etc complete as per the instruction of Architect/EIC. Wall paper will be selected by EIC. |
72 | Providing & fixing 12 mm thick toughened glass partition of make: ashai /saint gobin or equivalent including top & bottom side patch fitting of enox/ ozone or equivalent and filling between two glass dowcorning silicon selant etc as per detail drawing and instruction of Architect/EIC. |
73 | Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on cement board as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately 26.43.2 Cement Bonded particle board 8 mm (Termite, Fire & Moisture Resistance), as per IS:14276 : 1995 |
74 | Expoxy Boanding Coat:-Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC/KotaStone as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
75 | Epoxy Primer-Providing and laying priming coat of Foscroc Nitoprime 25 or approved equivalent as per manufacturer"s specification and direction of Engineer-in-charge |
76 | Epoxyflooring screed-Providing and laying thick free flow epoxy screed material of Fosroc EU5 or approved equivalent complete as per manufacturer"s specification and directionof Engineer-in-charge. The rate is of per 2mm avaerage thickness per sqm. |
77 | Epoxy Final-Providing and laying 2mm thick top finish coat of Fosroc Nitoflor SL2000 or approved equivalent complete as per manufacturer"s specification and direction of Engineer-in-charge. |
78 | Removing of old wooden door frame with hold fast, repairing it as per new size as per direction of Architect/EIC and refixing it at new location in wall with new hold fastner using required 1:4 cement mortar etc complete including cost of all material, labour, tools, tackles etc. |
79 | Providing & fixing 12 mm thick plywood of diamond or its equivalent of approved quality fixing horizontally, vertically or in any direction with nails, screws cutting to required size, necessary teak wood batten support, teakwood beading etc with all labour,materials etc. complete |
80 | Providing and fixing the 19 mm thick ASSO PF plywood waterproof |
81 | Supply and fixing plain/ground glass panes 6 mm thick in doors,windows,partition etc fixed with necessary pins,putty/rubber lining,T.W.battens as the case may be all labour materials etc complete, hinges, screws, bolts,clamps all included. |
82 | providing & fixing 12mm thicktoughened glass door of make: ashai/ saint gobin or equivalent including"H" handle size of 1"0" long with approved make floor spring with patch fitting of enox/ ozone or equivalent etc complete as per detail drawing and instruction of Architect/EIC. |
83 | Auto Blinds for crane:- Horizontal roller Blinds with vertical opening closing complete withIP31 tubular motor of appropriate rating, noise level 40dB, make:- somfy or equivalent, with wireless remote operation complete with track /rollers/ blinds with PVC Coated Fabric , complete in all respects. Fitting cost included. Detailed specs as per SCC. Motorised Window Blind: Made of soft and warm fabric applied with RF remote control. Simply operate and there is no wall power outlet needed. In-built tubular motor , slient and durable. Blackout Roller Shades , block up strong light means absolute privacy and a complete avoidance of the effects of light, ensure indoor rest and activities and help to protect . Easy to operate--Built-in high quality motor, easy to install and use. High quality materials--Adopt thickened eco-friendly fabric,oil and water proof,. Easy to clean, it can use duster or vacuum to whisk away dirt. |
84 | Interior approval, drawing and other architecture related chrages with approval for architect:-Consultancy services for interior designing Scope of work include the following: 1. Interior designing of Centre of Xpertise 2. Facelift of entrance 3. Supervision of execution whenever required. 4. Approval of materials and drawings. 5. Cost includes five visit from interior designer. |
85 | InteriorVisitation charges after 5 visits |
86 | Wiring for circuit (any light point/ fan point/ exhaust fan point/ call bell point)/ submain wiring alongwith earth wire with following size FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit with 20/25mm or required size PVC conduit (along with bends, couplers, saddles & screws) . Required recessing, and massonary etc shall also be done, no seperate line item for that. |
87 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
88 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
89 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
90 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
91 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
92 | 5/6 A switch |
93 | 3 pin 5/6 A socket |
94 | 15/16 A switch |
95 | 6 pin 15/16 A socket |
96 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
97 | 1 or 2 Module (75mmX75mm) |
98 | 3 Module (100mmX75mm) |
99 | 4 Module (125mmX75mm) |
100 | 6 Module (200mmX75mm) |
101 | 12 Module (200mmX150mm) |
102 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
103 | 1 or 2 Module |
104 | 3 Module |
105 | 4 Module |
106 | 6 Module |
107 | 12 Module |
108 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
109 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required Two pair |
110 | Supply and Fixing of modular type Telephone socket |
111 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
112 | Supplying and fixing 8 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), Double door |
113 | Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
114 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63A |
115 | Supplying and fixing of 9-15WLED Spot Light/focus Light fixture stand mounted, Warm White. Make Havells or equivalent. Color and style as per EIC> |
116 | Supply and fitting of Led Aluminum Profile Concealed-60x12mm of required length, make havels or equivalent. Color and style as per approved by EIC> |
117 | Supply and Fixing of RJ 45 CAT 6 computer data socket |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy