}

Construction Of State Level Water Testing Laboratory At Sidhpur In Tehsil Dharampur District Mandi Hp Supplying And Installation Of Various Furniture Items For State Level Lab , Laboratory Module 750 With C-Frame Complete In All Aspects :- Providing And, sidhpur-Himachal Pradesh

Irrigation And Public Health Department has published Construction Of State Level Water Testing Laboratory At Sidhpur In Tehsil Dharampur District Mandi Hp Supplying And Installation Of Various Furniture Items For State Level Lab , Laboratory Module 750 With C-Frame Complete In All Aspects :- Providing And. Submission Date for this Tender is 10-02-2022. Coats and Jackets Tenders in sidhpur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30824948
Corrigendum : Construction Of State Level Water Testing Laboratory At Sidhpur In Tehsil Dharampur District Mandi Hp Supplying And Installation Of Various Furniture Items For State Level Lab , Laboratory Module 750 With C-Frame Complete In All Aspects :- Providing And
Open Tender
Indian
Himachal Pradesh
sidhpur
10-02-2022

Tender Details

Construction Of State Level Water Testing Laboratory At Sidhpur In Tehsil Dharampur District Mandi Hp Supplying And Installation Of Various Furniture Items For State Level Lab , Laboratory Module 750 With C-Frame Complete In All Aspects :- Providing And Fixing Complete Set C-Frame Based Modular Under Benchs Suspended Storage Unit Of Double Door And Single Drawer With Cam Lock Size Should Be Width 750Mm X Depth 530Mm X Height 635Mm, The Whole Unit Must Be Fabricated In 0.9Mm 120 Gsm Gpsp / Gi Sheet Metal With Adjustable Shelf. The Whole Unit Must Pure Epoxy Powder Coated With 70-800Micron Thickness. The Must Consist Of Ss / Pp Hinges, Drawer Should Be Fitted With Hettich / Hafele / Godrej Sliding Channels And Ss Door Handles. C Frames Should Have D-700 X W-30 Mm H-780 ( Sitting ) & H-890Mm ( Standing ) Vertical Legs Depending On As Actual Site Requirements. Connecting Sets Member Arms Should Be Made Gpsp / Gi 120Gsm In 1.2Mm Thickness And 5Mm End Profile Conectin To C Frames. Worktop Should Be Z Black Granite 17 ( ±1 ) Mm Thick With Pre Moulded And Polished Edges. The Overhang Of Granite Should Be 30 Mm – 50Mm. At Front Side Of Under Storage Cabinets, Neoprene Strip ( 2.5 Wide & 6 Mm Thick ) Backing Material For Granite Should Be Neoprene Fixing With Sr-998 Glue, As Required The Cover Panel End Side Panel For Main Unit, 600Mm D, 900Mm Ht. The Whole Unit Must Be Complying To Sefa 8M Standards. Test Report Must Be Submitted. Bidder Should Have Iso 18001:2007, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015, Ohsas, Bifma. The Bidder Must Submit Work Order Copy Of Similar Work In Any Govt. Institute / Establishment. , Laboratory 600Mm Pp Sink Module With Acessories Complete : Providing And Fixing Of 600Mm Under Bench Suspended Sink Storage Unit Of Width 600Mm, Depth 530 Mm, Ht Of Unit 635 Mm With Two Shutters. The Whole Unit Must Be Pure Epoxy Powder Coated 70-80Micron Coated 0.9Mm Metal Sheet Gpsp, Cabinet Shutter Must Be Fitted With Ss / Pp Hinges, Ss Door Handles Of Approved Make. The Polypropylene Sinks ( Drop-In ) Of Overall Size 500L X 398W X 235D ( Mm ) Or As Per Site Black Color Classic Timeless Appearance In Matt Finish, Non Rusting And Easy To Maintain With Bottle Trap. Waste Coupling For Pp / Ceramic. Anti-Siphon Bottle Trap, Size : 38Mm Dia. ( Black Color ) Serated Flexible Connector To Connect Sink To The Waste Line, Length 1Mt. And 38Mm Dia. Brass Epoxy Coatedwater Faucets For Sink Unit Shall Have 3 Way ( 2 Straight+1 Swan Neck ) Turn Type Water Faucets. It Should Be Ph And Rust Resistant With Pp Regulators, Has Detachable Hose Nozzles, Allay Pressure, Changeable High-Pressure Outlet Constructed Or Normal Clean Outlet Control Of Water Flow Faucet Immediately. Worktop Should Be Be Et Black Granite ( Acid / Chemical Resistance ) 17 ( ±1 ) Mm Thick With High Quality Granite In Jet Black Colour With Pre Moulded, Pre Polished Edges Abd Shamphering. The Overhang Of Granite Should Be 30 Mm – 50Mm. At Front Side Of Under Storage Cabinets, Neoprene Strip ( 2.5 Wide & 6 Mm Thick ) Backing Material For Granite Should Be Neoprene Fixing With Sr-998 Glue. Complete In All Respect As Directed And Upto The Entire Satisfaction Of Engineer In Charge.The Whole Unit Must Be Complying To Sefa 8M Standards. Test Report Must Be Submitted. Bidder Should Have Iso 18001:2007, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015, Ohsas, Bifma. The Bidder Must Submit Work Order Copy Of Similar Work In Any Govt. Institute / Establishment. , Laboratory 600Mm Pp Sink Module With Acessories Complete :Laboratory 6750Mm Pp Sink Module With Acessories Complete : Providing And Fixing Of 750Mm Under Bench Suspended Sink Storage Unit Of Width 700Mm, Depth 530 Mm, Ht Of Unit 635 Mm With Two Shutters. The Whole Unit Must Be Pure Epoxy Powder Coated 70-80Micron Coated 0.9Mm Metal Sheet Gpsp, Cabinet Shutter Must Be Fitted With Ss / Pp Hinges, Ss Door Handles Of Approved Make. The Polypropylene Sinks ( Drop-In ) Of Overall Size 500L X 398W X 235D ( Mm ) Or As Per Site Black Color Classic Timeless Appearance In Matt Finish, Non Rusting And Easy To Maintain With Bottle Trap. Waste Coupling For Pp / Ceramic. Anti-Siphon Bottle Trap, Size : 38Mm Dia. ( Black Color ) Serated Flexible Connector To Connect Sink To The Waste Line, Length 1Mt. And 38Mm Dia. Brass Epoxy Coatedwater Faucets For Sink Unit Shall Have 3 Way ( 2 Straight+1 Swan Neck ) Turn Type Water Faucets. It Should Be Ph And Rust Resistant With Pp Regulators, Has Detachable Hose Nozzles, Allay Pressure, Changeable High-Pressure Outlet Constructed Or Normal Clean Outlet Control Of Water Flow Faucet Immediately. Worktop Should Be Be Et Black Granite ( Acid / Chemical Resistance ) 17 ( ±1 ) Mm Thick With High Quality Granite In Jet Black Colour With Pre Moulded, Pre Polished Edges Abd Shamphering. The Overhang Of Granite Should Be 30 Mm – 50Mm. At Front Side Of Under Storage Cabinets, Neoprene Strip ( 2.5 Wide & 6 Mm Thick ) Backing Material For Granite Should Be Neoprene Fixing With Sr-998 Glue. Complete In All Respect As Directed And Upto The Entire Satisfaction Of Engineer In Charge.The Whole Unit Must Be Complying To Sefa 8M Standards. Test Report Must Be Submitted. Bidder Should Have Iso 18001:2007, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015, Ohsas, Bifma. The Bidder Must Submit Work Order Copy Of Similar Work In Any Govt. Institute / Establishment. , Laboratory Module 600 With C-Frame Complete In All Aspects :- Providing And Fixing Complete Set C-Frame Based Modular Under Benchs Suspended Storage Unit Of Double Door And Single Drawer With Cam Lock Size Should Be Width 600Mm X Depth 530Mm X Height 635Mm, The Whole Unit Must Be Fabricated In 0.9Mm 120 Gsm Gpsp / Gi Sheet Metal With Adjustable Shelf. The Whole Unit Must Pure Epoxy Powder Coated With 70-800Micron Thickness. The Must Consist Of Ss / Pp Hinges, Drawer Should Be Fitted With Hettich / Hafele / Godrej Sliding Channels And Ss Door Handles. C Frames Should Have D-700 X W-30 Mm H-780 ( Sitting ) & H-890Mm ( Standing ) Vertical Legs Depending On As Actual Site Requirements. Connecting Sets Member Arms Should Be Made Gpsp / Gi 120Gsm In 1.2Mm Thickness And 5Mm End Profile Conectin To C Frames. Worktop Should Be Z Black Granite 17 ( ±1 ) Mm Thick With Pre Moulded And Polished Edges. The Overhang Of Granite Should Be 30 Mm – 50Mm. At Front Side Of Under Storage Cabinets, Neoprene Strip ( 2.5 Wide & 6 Mm Thick ) Backing Material For Granite Should Be Neoprene Fixing With Sr-998 Glue, As Required The Cover Panel End Side Panel For Main Unit, 600Mm D, 900Mm Ht. The Whole Unit Must Be Complying To Sefa 8M Standards. Test Report Must Be Submitted. Bidder Should Have Iso 18001:2007, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015, Ohsas, Bifma. The Bidder Must Submit Work Order Copy Of Similar Work In Any Govt. Institute / Establishment. , Providing And Fixinglaboratory Corner Unit With Accessories Complete Unit : Corner Modular Floor Unitcorner Module Main Unit, 850Mm X Depth 530Mm X Height 635Mm Epoxy Powerder Coated 0.9Mm Metal Sheet / 1.2Mm Verticle Leg Support In Virgin Steel Gpsp / Gi 120Gsm. Worktop Should Be Z Black Granite 17 ( ±1 ) Mm Thick With Pre Moulded And Polished Edges. The Overhang Of Granite Should Be 30 Mm – 50Mm. At Front Side Of Under Storage Cabinets, Neoprene Strip ( 2.5 Wide & 6 Mm Thick ) Backing Material For Granite Should Be Neoprene Fixing With Sr-998 Glue, As Required The Cover Panel End Side Panel For Main Unit, 600Mm D, 900Mm Ht. The Whole Unit Must Be Complying To Sefa 8M Standards. Test Report Must Be Submitted. Bidder Should Have Iso 18001:2007, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015, Ohsas, Bifma. The Bidder Must Submit Work Order Copy Of Similar Work In Any Govt. Institute / Establishment. . , Laboratory Single Reagent Shelf For Acids & Chemicals Single Sided Reagent Shelf 2-Tier Size 150Mm Wide Shelf Size Should Be Complete Modular Design With Adjustable Shelves. Each Reagent Rack Pillar Should Be Of 700Mm ( H ) X 120Mm ( D ) X 50Mm ( W ) Size Made From 100 X 50 Rectangular Sheet Metal Slotted Section Of 1.2Mm Thickness On Both Sides Of The Pillar. Shelves Of The Reagent Shelf Should Habe Brackets Fitted In The Pillar Slots For Adjustments. It Should Have Provision For Removable Cover For Easy Access During Repair Of Hidden Parts. Shelves Frame Should Be Made From 1Mm Thick Sheet Metal Fitted On Angle Profile To Rest The Granite / Prl / Glass Sheet / 1Mm Gpsp Sheet. Electrical Trunking Should Made From 0.8Mm Thick Gpsp Sheet With Cutouts For Switch / Sockets And Other Accessories And Provision For Gas Line To Pass Through. Each Component Should Have 70-80 Micron Epoxy Powder Coating Resistant To Corrosion.Provision For Gas Distribution Should Be Made In The Reagent Trunking. , Sitc, Providing And Fixing 1500 Fume Hood Apparatus General Description The Fume Hood System Should Complete In All Aspects With Modern And Dynamic And Ergonomic Design Including The Polypropylene Frp Ducting, Pp Blower System, Pp+Frp Chemical Resistant Wet Scrubbing System For Fume Treatment Before Exhaust. The Fume Hood Ducting Should Be Strictly As Per The Approved Drawing And Layout By The Committee. Vendor Must Submit The Layout For Approval Before The Start Of The Supply And Commissioning. Fume Hood Should Be A Single Body Design For Full Height Upto 2350Mm Constructed In Heavy Structure Made Of 1.2Mm Sheet Gpsp / Gi Sheet Metal Frame. The Whole Unit Should Be Supported With Internal Frame Structures In 1.6Mm Sheet Metal Supports.Overall Dimensions Of The Fume Hood System Should Be 1500Mm ( W ) X 900Mm ( D ) 2350Mm ( H ) . One Anemometer Must Also Be Supplied With Equipment. , Fume Hood Body: System Should Be Single Body Type Design Constructed From Gi Sheet Metal Only. The Main Body Of The System Should Not In Two Piece Design I.E Upper Structure And Lower Structure. Both Lateral Sides Of The System Should Have Provision For Two Open Able Panels For Easy Maintenance Of Gas And Water Utilities. The Back Panel Should Also Be Possible To Remove And Open. Reaction Monitoring Interface Device- The Fume Hood Must Include An In Built Interface With Devices Which Are Capable Of Controlling The Heating Process Of At Least Four Reactions Simultaneously Within A Specified Time Frame. The Temperature Range Should Be ( Ambient To 250°C ) And The Time Should Be From 0 To 999 Minutes With A Precision Of±1 Oc. The Heating Process Will Stop Automatically Upon Process Completion. Sash System: Fume Hood Should Have An Electronically Controlled Sash System Which Should Work In Synchronization With The Air Flow Monitoring Of The System. Sash Should Have Sliding Mechanism On Front Pillars.Lubrication Free Sash System Should Be Vertically Sliding On The Front Pillars Pulley System With Linear Dry Bearings On Anodized Aluminum Profile Having 30-40Mm Width And 700 N Static Load Rating Along With Belts / Wire Driven With Counter Weight Balance. The Counter Weight Must Not Be Visible At The Back Side Of The System. The Back Panel Should Be Open Able For Maintenance. The Frame Of Sash Should Be 1Mm Gpsp / Gi Sheet Metal With 50Mm Wide Frame Rim Size Fitted With 5-6 Mm Thick Toughened Glass. Sash Should Not Be Visible On The Top Of The Fume Hood System When Open. Sash Moving Mechanism Should Have Provision To Upgrade To Automatic Sensor Based Opening And Closing At Site By The Manufacturer / Supplier. Sash Handles Must Be Rust Resistant.Minimum Inside Chamber Dimension And Design: Free-Standing Rigid Frame Structure Of Steel ( Gpsp / Gi Only ) 1.2Mm And 1.6Mm Respectively Shall Be Provided To Support Exterior Panels And Interior Liners & Baffle Panels. The Inner Chamber Should Be Having Off White Color Backalite / Hpl 12Mm Sheet Duly Sealed With Epoxy At The Joints. Inner Liner: Interior Liner Panels Must Have Minimum 12 Thick Phenolic Resin High Pressure Laminate Or 12Mm Backalite Fixed On Gpsp / Gi Sheet Metal Frame From Outer Side Panels Using Stainless Steel Screws With Plastic Covered Heads. Front Utilities Pillars & Facia: Fume Hood System Should Have Continuous Front Facia Pillars With 4 Cut-Out With Removable Cover On Each Side For Hosing The Gas, Water And Electrical And Other Utilities. Baffle: A Stable, Non-Adjustable Baffle Shall Be Provided To Aid In Distributing The Flow Of Air Into And Through The Hood. The Design Of The Baffle Should Be Ergonomic. The Baffle Shall Be Spaced Out 3-4 Inches From The Back Wall Of Hood. The Baffle Shall Be Removable For Cleaning. Air Foil: A Streamlined Airfoil Shall Be Integral At The Bottom Of The Hood Opening On Bench And Distillation Hoods. This Foil Shall Provide A Nominal 1” Open Space Between The Foil And The Top Front Edge Of The Work Surface To Direct An Air Stream Across The Work Surface To Prevent Back Flow Of Air. The Air Foil Mist Have Slotted Cutouts For Smooth Flow Of Air When Sash Is Closed. Air Volume: System Should Be Having Constant Air Volume At 100 Fpm ( Feet Per Min. ) Is 630 Cfm ( Cubic Feet Per Minute ) Or Better. Air Velocity Monitoring System: System Should Be Having Tel / Siemens Or Equivalent Air Flow Monitoring System, Make Tel / Siemens. , Utilities: System Should Have Remotely Controlled Gas And Water Fittings & Utility Services Includes Nitrogen, Vacuum, Water Remote Control Valves Controlled By Extension Rods Projecting Through The Control Panels Of The Hood, With Colour Coded Plastic Handles. Interior Fitting For Gases And Water Shall Ss 304 Grade Seamless Tubing. All Utilities Valves Can Be Controlled Independently And Gas Fitting -7 Bar And Water Fitting-10 Bar Make: Water Saver / Broen / Tof Italy / Kl Lab / Rw Utilities Maintenance: For Easy Maintenance And Replacements Of Gas And Water Utilities, The Interior Liner Panels Shall Be Removable Without Disassembly Of The Frame Structure And Outer Steel Panels. Worktop: 18Mm ( ±1Mm ) Z Black Granite. Electrical Fittings: A. 5 / 15 Amps Single Phase Socket With 16 Amps Mcb-2 No, B. Internal Wiring Complete C. Led Light With On-Off Switch D. Blower On-Off Switch E. Elcb For Safety Purpose, F. Emergency On-Off Switch For Entire Unit, G. Top Panel Light Indicators If The System Is On Or Off. Note: The Electrical Fittings Should Be Such That The Sockets Are Fitted In Side The Fume Hood Chamber And Switch For On Off And Mcb Should Be Mounted On The Outside Panel Of The Fume Hood Below Air Foil Plate. , Apparatus Grid: Should Have Adjustable Ss 316 Grade Solid 12Mm Thick Powder Coatedgrid In The Fume Hood System. • Drip Sink: System Should Be Having A Cup Sink With Panel Mounted Water Tap And Controller. • Base Cabinet: The Base Cabinets Must Be Plinth Design. The Whole Unit Should Be Constructed From Virgin Gpsp / Gi Sheet Metal Of 0.9Mm Thickness ( Thickness Of Sheet Metal Should Be Calculated Without Powder Coating And Powder Coating Must Be 70-80 Microns 100% Pure Epoxy Powder Coated Meeting The Sefa 8M Standards Of Test And Procedures. The Cabinets Should Be Available In Double Shutter And Single Shutter Configurations Fitted With Ss304 Matt Finish ( Stainless Steel ) 75 X 10, Stainless Steel L – Type Butt Hinges Along With Along With Rolling Catcher. Shutter Should Be Able To Withstand Minimum 25Kg Load. It Should Be Fitted With High Quality Hafele / Hettich Or Equivalent Sliding Channels With 40, 000 Life Cycle Test Operation Complying Din En 15706:2009-08 Din En 14749: 2005-11, Dinen 14074 / Dinen 14071 / 2 / 3 Supported With A Test Certificate. Sefa Load Bearing Standards Must Be Followed For Cabinets. The Shutter Should Have Sandwiched Construction With Sound Damper Strips. Damper: Fume Hood Should Have A Damper For Fume Exhaust And Connecting To The Pp Frp Ducting With Provision To Open And Close As And When Required. , Compliance & Certifications: The Manufacturer Should Be Having Iso 45001:2018, Iso 13485:2016, Iso 14001:2015, Iso 9001:2015. The Fume Hood System Should Be Fabricated As Per Ashrae / En Test Procedure And Protocols. , Centrifugal Blower Unit • Casing Moc: Pp+Frp • Impeller Moc: Pp ( Fabricated ) • Motor: 2Hp, 440 Volts, 50 Hz , 1 Or 3 Phase Supply Make Cg / Kirlosler • Stand: Pp+Frp Or Epoxy Powder Coated • Volume Flow=1400-2000 Cfm • Motor Rpm=1440 Or More. Wet Scrubbing Unit • Scrubber Details: • Moc: Pp+Frp • Height:2200-2400 Mm, Diameter Should Be:600 Mm • Packing Media : Pp Pall Ring • Mist Eliminator : Pp Demister Pad • Circulation Tank Capacity: 200 Litre Approx • Circulation Pump: Mp60 Chemical Grade Pump • Operating Temperature: Ambient • Water Jet Shower: Should Have Water Shower System. • Motor On Off Switch. • Should Comply The Iso For Environment Safety Norms. Installation Of Fume Hoods As The Item Is Turnkey Basis, Any Civil Works Required For Drilling Of Brick Wall, Demolishing Brick Work For Ducting Etc Shall Be In The Scope Selected Of Bidder. Warranty- 3 Years Comprehensive Warranty On The Complete System. Installations: Suppliers Should Supplied Minimum 35 Fume Hood System And 8 Nos Of Scrubbing System To Any Government Institution Or University. Civil Work: Supplier Will Do The Required Civil Work For The Commissioning Of The Fume Hood System If Any Required At The Site. , Ducted Chemical Storage Unit Complete With All Accessories Providing And Fixingchemical Storage Cabinetsas Per Following Specifications:- Ms Chemical Storage Cabinet 1000 X 486 X 1800Mm : 1.2Mm Thick Made Of Gpsp With Epoxy Coating ( 60-70 Micron ) . Four Door Cabinet With Glass Moc : Ms Gpsp 1000Mm W X 486Mm D X 1800Mm Ht. Inside Must Be Polyprylene + Fiber Reinforced Plastic Coatong 3Mm Quoting Complete In All Respect As Directed And Upto The Entire Satisfaction Of Engineer In Charge. , Duct Pp+Frp ( Polypropylene+ Fiber Reinforced Plastic ) Complete Ppfrp 10-12 Inch” Rigid Duct With Acessories For Fume Hoods: Pp+Fpr Ducting With 2.75-3Mm Pp Inner Side And 3Mm Frp Outer Side. Ducts Should Be 25 Mm X 25 Mm Stitch Welding Is Done On Inner Surface And Continuous Weldingon Outer Surface. While Making The Lining, There Should Not Be Any Air Pockets Or Any Sort Of Uneven Finish. The Flange Thickness Should Be 8Mm. All Flanges Are To Be Matched With M8, Gi Fasteners And Flat Washers On Both The Sides. 90 Degrees Bend Of 10-12 Inches, U-Clamps For Rigid Duct 10-12 Inches, Flange 10Mm Thick Round With Fasteners Pp+Frp For 10-12” Duct, Hanging Ms Support For Rigid Duct 10-12, Flexible Bellow For The Blower, Raincowl For Blower System, Inlet Transition For Blower System, Per Running Meter Cost Should Be Mentioned. Complete In All Respect As Directed And Upto The Entire Satisfaction Of Engineer In Charge. , Providing And Fixing Of Gpsp Epoxy Powder Coated Electrical Raceways For With The Provision For Face Plate Housing For One 5Amp And One 16 Amp Socket And Two 5Amo Ad 15Amp Switches Each. Raceways Should Be Made Of 0.8 Mm Thick Gpsp. It Should Be 2Meter With 3 Cut Outs , Providing And Fixing Of Gpsp Epoxy Powder Coated Electrical Raceways For With The Provision For Face Plate Housing For One 5Amp And One 16 Amp Socket And Two 5Amo Ad 15Amp Switches Each. Raceways Should Be Made Of 0.8 Mm Thick Gpsp. It Should Be 1.5Meter With 2 Cut Outs , Ss 316 1 / 8 Or 1 / 4 Gasfittings Complete As Per Design Reuirements Providing And Fixing Of Ss 316 Seamless Gas Tubing Including The T Joints, Reducers, Needle Valves For Argon, Helium, Nitrogen, Zero Air, O2, H2 Or Any Other Gases As Per The Site Requirementwith Hanging Clamp Support Complete As Directed And Up To The Satisfaction Of Engineer Incharge , Sitc Of 3 Stage Purification Panel Gas Fittings Complete For Pesticide Lab Providing & Fixing Purification Panel With Control Valves With Pressure Gauge ( For N2, Argon, Helium, Hydrogen Gas ) Complete As Directed And Up To The Entire Satisfaction Of Engineer In Charge , Control Valve Box With Pressure Gauge Meter Gas Fittings For Heavy Metal Testing Lab. Providing & Fixing Control Valve Box With Pressure Gauge Meter Complete As Directed And Up To The Satisfaction Of Engineer In Charge. , Control Valve Box With Pressure Gauge Meter Gas Fittings For Pesticide Lab. Providing & Fixing Control Valve Box With Pressure Gauge Meter Complete As Directed And Up To The Satisfaction Of Engineer In Charge. , Ss 304 Cylinder Manofold Gas Fittings Providing And Fixing Of Ss 304 Cylinder Manifold With Pigtail, Ms Cylinder Mounting Bracket Complete As Directed And Up Tothe Satisfactin Of Engineer In Charge. , Ss 316 T-Joint Connectors Gas Fittings Extra Providing & Fixing Ss 316 T-Joint Connectors Complete As Directed And Up To The Satisfaction Of Engineer In Charge , Ss 316 Needle Valves For 1 / 2” With Ss Connector And Fitting Gas Fittings Providing & Fixing Ss 316 Needle Valves For 1 / 2” With Ss Connector And Fitting Complete As Directed And Up To The Satisfaction Of Engineer In Charge , Gas Cylinder Hydrgen Filled Gas Cylinder 47Lt Capacity Ea With Valve Of Analytical Grade Purity 99.999 & Pure For H2 , Gas Cylinder Nitrogen Filled Gas Cylinder 47Lt Capacity Ea With Valve Of Analytical Grade Purity 99.999 & Pure , Gas Cylinder Argon Filled Gas Cylinder 47Lt Capacity Ea With Valve Of Analytical Grade Purity 99.999 & Pure , Gas Cylinder Zero Air Filled Gas Cylinder 47Lt Capacity Ea With Valve Of Analytical Grade Purity 99.999 & Pure , Gas Cylinder Helium Filled Gas Cylinder 47Lt Capacity Ea With Valve Of Analytical Grade Purity 99.999& Pure. , Gas Cylinder Bank- Ms Cylinder Bank With Priming Coat And Water Proof Paint Dual Coat. Firesaftey Certificate, Purity Certificate Must Be Attached. Complete In All Respect As Directed And Upto The Entire Satisfaction Of Engineer In Charge. , Providing And Fixing Of ( L ) 450Mm And W 450Mm Ss304 Exhaust Hood With Tube And Connector For The Chemical And Fume Exhaust Alongwith Pp / Gi Blower, 1 Hp Motor With 1000Cfm Capacity. , Provoding And Fixing Of Spot Extractor , Providing And Fixing Of Antivibration Table For Analytical Balance With 0.001 And 0.01Mg , Providing And Fixing Of Doubla Head Eye Wash , Providing And Fixing Of Ss 304 Body Wash With Foot / Hand Control Switch With Fittings And Acessories. Unit Must Be Chemical Resistant , Providing And Fixing Of Class Ii Type A2 Biosafety Cabinet 1200Mm As Per Ansi / En Norms , Z Black Granite 18Mm For The Laboratory Workshop , Installation Charges , Freight & Insurance Cost , Loading & Unloading Charges , Granite, Mason, Plumber, Electrical, Fitter Labour Charges.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Feb-2022 Corrigendum Date 10-02-2022

Key Value

Document Fees
INR 2500 /-
EMD
INR 272405.0 /-
Tender Value
INR 2.39 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail