Military Engineer Services-MES has published Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath Area Drainage Etc At Ratnuchak Mil Stn Under Ge Kaluchak Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath . Submission Date for this Tender is 19-02-2022. Footpath Work Tenders in kaluchak Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30817470
Corrigendum : Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath Area Drainage Etc At Ratnuchak Mil Stn Under Ge Kaluchak Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath
Open Tender
Indian
Jammu And Kashmir
kaluchak
19-02-2022

Tender Details

Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath Area Drainage Etc At Ratnuchak Mil Stn Under Ge Kaluchak Repair To Sunken Floor, Plumbing Rain Water Pipe Boundary Wall Fencing Hume Pipe Culvert Footpath Area Drainage Etc At Ratnuchak Mil Stn Under Ge Kaluchak

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jan-2022 Other Amendment Other 12-02-2022
2 31-Jan-2022 Revision of BOQ BOQ 12-02-2022
3 12-Feb-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR TO SUNKEN FLOOR, PLUMBING, RAIN WATER PIPE, BOUNDARY WALL, FENCING, HUME PIPE CULVERT, FOOTPATH, AREA DRAINAGE ETC AT RATNUCHAK MIL STN UNDER GE KALUCHAK
Sl. No. Item Description
1Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
2Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
3Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each and refixing in the same opening after carrying out necessary repair, complete all as specified & directed.
4Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
5Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
6Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
7Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
8Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
9Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
10Pressed steel frames of size 105mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, necessary welding for fixing ofbutt hinges of any size/any number,complete all as specified & directed. Note : PCC for filling of hollow portion shall be measured and paid for separately.
11PCC 1:3:6 nominal mix, type C-0 using 12.5mm graded crushed stone aggregate as in filling of pressed steel door frames/chowkats and similar items, complete all as specified & directed.
1235mm thick 2ndclass hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
1335mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
14Mild steel sliding door bolt, bolt type, stove enamelled black, with bright bolt not less 12mm dia, with and including a minimum of 6 bolts and nuts, 4 on bolt plateand 2 on stappleplate, 300mm long, complete all as specified & directed.
15300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel and fixed to pressed steel frame / MS frame/ wooden chowkhats including necessary welding work etc where-ever required, complete all as specified & directed.
16Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm, complete all as specifed & directed.
17Mild steel galvanised wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified & directed.
18Preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified & directed.
19PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
20Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan to any radius, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
21Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified & directed.
22Factory made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified & directed.
23Aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long, complete all as specified & directed.
24Extruded aluminium alloy handle, fabricated type, anodised, 150mm long, complete all as specified & directed.
25Butt hinges, medium weight, cold rolled, mild steel 100mm long, complete all as specified & directed.
26Non skid ceramic coloured tiles,7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed.
27Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
28Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting not exc. 10cm girth in brick/stone walls, complete all as specified & directed.
29Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed.
30Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed.
31Angle valves, 15mm bore, fancy type, chromium plated, cast copper alloy with capstan head,screweddown, high pressure, both ends screwed for iron pipe orfor union etc., fixed in repairs, complete all as specifed & directed.
32Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy with capstan head,screweddown, high pressure, both ends screwed for iron pipe orfor union etc., fixed in repairs, complete all as specifed & directed.
33Bib tap, 15mm bore, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
34Vitreous chinaware squatting pan, "Orissa Pattern" size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs,complete all as specified & directed.
35Vitreous china, wash hand basin, white, corner type of size 450mmx300mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts,chain and plug, porcelain stopper, 32mm dia PVC waste pipe, cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed.
36High density polyethylene pipes (HDPE) 40mm dia of pressure rating 6 kgf/cm2 laid including necessary fittings, fixed in repairs, complete all as specified & directed.
37PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed.
38PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified & directed.
39Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered `Hot’ or `Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe of 15mm bore,fixed in repairs, complete all as specified & directed.
40Brass chromium plated shower rose of 125mm size with or without swivel joints, fixed in repairs, complete all as specified & directed.
41PVC (SWR) floor trap, plainwith grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
42PVC (SWR) multi floor trapwith grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified & directed.
43PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls with clamps including dismantling of old unserviceable pipe, complete all as specified & directed.
44PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls with clamps including dismantling of old unserviceable pipe, complete all as specified & directed.
45110mm bore PVC (SWR) bends any radius with oval access door, fixed in repairs, complete all as specified & directed.
4675mm bore PVC (SWR) bends any radius with oval access door, fixed in repairs, complete all as specified & directed.
47PVC (SWR) vent cowl of size 110mm bore, fixed in repairs, complete all as specified & directed.
48PVC (SWR)junction single(Single T) equal or unequal, 110mm bore with oval access door, fixed in repairs,complete all as specified & directed.
49PVC (SWR)junction single(Single T) equal or unequal, 75mm bore with oval access door, fixed in repairs,complete all as specified & directed.
50600x450x6mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws & cup washers, fixed in repairs, complete all as specified & directed.
51Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast,PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
5220mm thick granite stone work (table rubbed and polished) machine cut in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting polishing, half rounding of exposed edges of stone slabs over& including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
53Complete removal of the existing sunken treatment including roughening and preparation old surfaces of concrete floor by picking, scurubbing down with steel brushes, sweeping clean and washing down with water to remove dust etc and applying the followingtreatment :- (a) 15 thickrendering on fair faces of brick work or cement surfaces in cement mortar 1:4 with using integral water proofing compound as per manufacturer instructions byweight of cementtosunkenportion including wall of sunken portion with proper slope towardsoutsideand finishing cement concrete or brick work surface even and smooth using extra cement, finishing concrete including walls of sunken portion with proper slope. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
54(d)Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3mm thick weight not less than 3.6 Kilogram/Square Metre with 160 Grams/Square Metre non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e)Applying 5th course of a coat of bonding materialwithblown type bitumen of grade 85/25 heating to aworking temperature of 180° C and applied @ 1.2 Kilogram/Square Metre. Note : Ponding shall be done in sunken portion area by filling water which shall be kept there for 48 Hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shallbe repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
55PCC 1:7:14, nominal mix, type F-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified & directed.
56Galvanized iron tube as in spout pipe, medium grade, 40mm bore in short length of 45cm, cut to shape required including Cutting/ drilling holes through RCC beam/brick wall by mechanical mean exc 300mm deep and making goodin cement mortar 1:3, completeall as specified & directed.
57Steel windows with bottom hung or top hung shutters with glazing bars, including hinges, steel side arms or peg stays and locking arrangements, one shop coat of red oxide zinc crome primercomplete all as specified & directed.
5825mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in sunken floor using water proofing admixtures as per manufacturer"s instructions, complete all as specified and as directed.
59Soap dish, brass chromium plated, of size 100x60mm, fixed to walls with chromium plated screws, fixed in repairs, complete all as specified & directed.
60Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs with chromium plated brass screws & wooden/plastic cleats, complete all as specified & directed.
61Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b)Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
62(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding materialwithblown type bitumen of grade 85/25 heating to aworking temperature of 180° C and applied @ 1.2 Kg/Sqm.
63PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in padding on roof, for levelling of roof slab,finished even and fair, complete all as specified & directed.
64Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted & fixed in position of capacity 500 ltrs including making connections, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight20 mm - 210 gms) and dismantling of old unserviceable water tank of any description, complete all as specified & directed.
65Gun-metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed,fixed in repairs, complete all as specified & directed.
66Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
6710mm thick plastering in cement mortar1:4 on concrete surfaces of chajjaa, upward fascias, and similar items including necessary formwork and scaffolding after making good decayed concrete portion in cement mortar 1:3, height upto 11m, applying two coats of acrylic cementious water proofing coating with dry film total thickness approx 1mm as per manufactureres instructions in patches including taking down old cement plaster, complete all as specified & directed.
68Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
6915mm thick rendering in cement mortar1:6 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
705mm thick rendering in cement mortar1:3 on concrete surfaces ofceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
715mm thick rendering in cement mortar1:4 over 10mm thick rendering in cement mortar 1:6 onbrick or concrete surfaces using integral water proofing compound,surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Integral water proofing compound shall be measured & paid for seperately under respective items.
72Supply only integral water proofing compound, complete all as specifed & directed.
7375mm thick PCC 1:3:6, nominal mix, type C2, using 40mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including forming and filling of joints 12mm wide with bituminous filler, complete all as specified & directed.
74Preparation of new plastered surfaces of wallsand applying three coats of white wash, complete all as specified & directed.
75Preparation of old decorated plastered or unplastered surface of walls including cornices, pilasters etc by brooming down or by steel wire brushes, scrapingdown smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
76Preparation of new plastered surfaces of ceilingand applying three coats of white wash, complete all as specified & directed.
77Preparation of old decorated plastered or unplastered surface of ceilingby brooming down or by steel wire brushes, scrapingdown smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying two coats of white wash, complete all as specified & directed.
78Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats ofsynthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
79Preparation of new plastered or concrete surfaces of wallsand applying two coats of cement base paint of any tint over a coat of cement primer, complete all as specified & directed.
803mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
81Stainless steel sink with drainage board made of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting unionetc. and overall size 915x460mm with bowl size 410x330x160mm, fixed in repairs, complete all as specified & directed.
82Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
83Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for(Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
84TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
85Screed bed or bedding layer of cement mortar1:6, 15mm thick for laying floor finishes, complete all as specified & directed.
86Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match, complete all as specified & directed.
8775mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of floor, complete all as specified & directed.
88Preparation of old painted wooden or wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
89Preparation of old decorated steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified & directed.
90Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified & directed.
91Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified & directed.
92Dismantling of fencing wire of any type & description, complete all as specifed & directed.
93RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
94Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
95TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
96TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
97Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified & directed.
98Mild steel framed work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified & directed.
99Mild steel framed work as in grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified & directed.
100Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified & directed.
10115mm thick rendering in cement mortar1:4 onfair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
10215mm thick rendering in cement mortar1:4 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified & directed.
103100mm thick PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in pavement, hard standing, path etc, surface finished even and fair, laid in alternate bays including form work, complete all as specified & directed.
10415mm thick rendering in cement mortar1:6 onfair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
105Machine Pressed precast concrete interlocking paver block any shape and size M-35 Grade,60mm thick confirming to IS-15658-2006 with grey cement and pigments laid over and including 50mm thick sand cushioning,complete all as specified & directed.
106PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in surface channel and drains including necessary form work, complete all as specified & directed.
10750mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in floor, surface finished even and smooth without using extra cement, laid in alternate bays, complete all as specified & directed.
108PVC floor dividing strips, 1.5mm thick and 38mm wide, complete all as specified & directed.