}

Repair / Maintenance And Cleaning Of Manholes, Septic Tank, Soak Wells, Sewage Line Etc. And Repair To Drain, Path, Culverts, Cattle Traps, Boundary Wall, Fencing, Gate, Garbage Pits At Zone C And D Under Ge ( East ) Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maintenance And Cleaning Of Manholes, Septic Tank, Soak Wells, Sewage Line Etc. And Repair To Drain, Path, Culverts, Cattle Traps, Boundary Wall, Fencing, Gate, Garbage Pits At Zone C And D Under Ge ( East ) Lucknow. Submission Date for this Tender is 04-03-2022. Drainage Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30817395
Corrigendum : Repair / Maintenance And Cleaning Of Manholes, Septic Tank, Soak Wells, Sewage Line Etc. And Repair To Drain, Path, Culverts, Cattle Traps, Boundary Wall, Fencing, Gate, Garbage Pits At Zone C And D Under Ge ( East ) Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
04-03-2022

Tender Details

Repair / Maintenance And Cleaning Of Manholes, Septic Tank, Soak Wells, Sewage Line Etc. And Repair To Drain, Path, Culverts, Cattle Traps, Boundary Wall, Fencing, Gate, Garbage Pits At Zone C And D Under Ge ( East ) Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2022 Date corrigendum Date 25-02-2022
2 25-Feb-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work:REPAIR/ MAINT AND CLEANING OF MANHOLES, SEPTIC TANK, SOAK WELLS, SEWAGE LINE ETC. AND REPAIR TO DRAIN, PATH, CULVERTS, CATTLE TRAPS, BOUNDARY WALL, FENCING, GATE, GARBAGE PITS AT ZONE ‘C’ AND ‘D’ UNDER GE (EAST) LUCKNOW
Sl. No. Item Description
1Dewatering of soak well, septic tanks by using mechanicalpump diesel driven with fuel operator and crew of water etc at site complete all as specified and directed.
2Cleaning of soak well, septic tank by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at thelocation notified by the local Municipal Corporation/Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soiland sprinkling bleaching powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
3Cleaning of blockage of sewer lines of any sizes/ dia of sewer line (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding ofsewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well all as specified and directed . Note :- For item No 1 to 3: 1.The cleaning shall be carried out with mechanized operation by means of diesel / electric operated vehicle mounted hydraulic operated high pressure suction -cum -jetting machines fitted with pump of required capacity and the sludge sucked out with Super Succer Machine of required capacityand sent to storage tanks for further disposal to the authorised disposal site land at any distance and without any additional cost. (2) The sludge deposited in sewage line shall be fully cleaned and disposed off the same outside the MOD land at any distance and without any additional cost , on the same day when it was taken out.The job shall be carried out with safety precaution equipmentand with strict supervision. (3) During the mechaized operation , the service provider /Contractor shall be equiped with Gas monitor , nylon rope ladder , torch light and compressor blower etc along with the sewage cleaning truck mounted suction / jetting machine (4) The unit rate quoted by the contractor shall interalia deemed into the cost of providing skilled driver and operator and supervising engineer including provision of water for jetting & removal of sludge /silt /liquid /mud & sand (in foul position )etc (5) The contractor shall engage the above mentioned T & P and intimate to Enginner - In -Charge in writing with Machine No./ Vehicle No. etc for their record and prior approval . 6. A Register shall be maintained by contractor showing the Machine No /Vehicle No. and their deployment at site mentioning time and date duly sighned by concern JE , Engr -in- charge and contractor.
4Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at thelocation notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soiland sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
5Cleaning of all manholes exc 1.50M but not exc 3.00 M depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at thelocation notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soiland sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
6Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC"s, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning ofdrain pipes of any diaby rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at thelocation notified by the local Municipal Corporation/Cantt board).complete all as specified and directed. Note :-For item No- 4 to 6: 1. To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helperfrom 0900 hours to 1700 hoursatComplaint cell ofAGE B/R area mentioned in the contracton daily basis, with manual/pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health). (2)The Nos of person indicated in above items as assumed by the department, shall remain present at the complaint cell of AGE B/R area mentioned in CA. Contractor may have to deploy more manpower in the particular area anddeploy adequate sewage cleaning machinary/ equipments to clean the line andopen blockages. Rates quoted shall be deemed to have considered in the items all such contingencies. (3)In case of non availability/ absence of any of minimum required man power , the recovery for the same shall be effected @ Rs 500.00 per day for the absence period proportionaly. (4) If necessiated by the Engr-in-charge/GE for work on Sunday/ holidays, the contractor shall provide tradesmen with helpers. (5) Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained by contractor duly signed by concern JE , Engr -in- charge and contractor.
7Taking down cement plaster on brick or concrete surfaces including raking out joints hacking for key and scrubbing down with water etc complete all as specified and directed.
8Demolition of brick work built in cement mortar or cement lime mortar including all of quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
9Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
10S&F chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in near cement slurry with grey cement and pigments in floors including 15mm thick sreed bed in CM 1:6 complete all as specified and directed
11M&L for brick work with Sub class "B" bricks straight or curved on plan exc 6m mean radius in CM 1:6 complete all as specified and directed.
12M&L for brick work with fly ash bricks, straight or curved on plan exc 6 mtr mean radius, old size brick built in cement mortar 1:4 complete all as specified and directed.
13M&L for rendering 15mm thick in CM 1:4 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
14M&L rendering 15mm thick in CM 1:6 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
15M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of primer of approved shade/tint complete all as specified and directed.
16Demolition of reinforced cement concrete as cover slabs for manhole, septic tank and soak well etc (reinforcement cut as reqiured to faciliate demolition) complete all as specified and directed.
17M&L for precast manhole cover slabs in RCC 1:2:4, type B-1, using 20 mm graded stone aggregate and set in CM 1:4 complete all as specified and directed. ( Note: Reinforcement sted will be measured and paid for seperately)
18M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200 mm thick horizontal or sloping for rough finished surface of flat concrete complete all as specified and directed.
19M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 10cm but not exc 20cm wide complete all as specified and directed.
20M&L for RCC 1:1.5:3 (nominal mix using 20 mm graded stone aggregate as in slabs supported on walls, roof beam and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
21M&L for TMT bars 10mm dia and over cut to length, bent to shape required,including cranking and bending spirally for hooping for coloumns, hooking ends and binding with and including M.S wire not less than 0.9mm dia complete all as specified and directed.
22M&L for TMT bars 6mm to 8mm dia cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
23M&Lfor SGSW pipe of 150mm bore jointing with cement joints including necessary excavation and earth work and returning, filling in trenches and removal of soil upto 50m,including taking up broken sewage pipe line complete all as specified and directed.
24S&F UPVC underground drainage pipe (UDS) type"B" 160mm dia with wall thickness 4mm (min) and pressure 4KN/m2 jointed in cement solvent complete including testing and concrete bed to drain pipe including padding under haunching against the sides of pipes after they are laid and tested in PCC 1:3:6 type C-2 complete all as specified and directed. Make : Jain Pipes/Finolex/Ajay Flowguard/Armstrong/Suprime as approved by GE.
25M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and directed.
26Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m complete all as specified and directed.
27Excavation in trenches (soft/loose soil) not exc 1.5 m wide and not exc 1.5 m depth for foundation for mainholes, shafts etc 2. exc 10 sqm on plan area and not exc 1.5 m in depth and getting out etc complete all as specified and directed.
28Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
29Removing excavated material not exc 50 m and depositing, where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
30M&L for PCC 1:4:8 typeD-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete as sub base of floor complete all as specified and directed.
31M&L for 75 mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in sub base of path/pavements etc complete all as specified and directed.
32M&LforPCC 1:3:6 type C2 in Surface channel or drains including necessary form works, stops ,moulds etc complete all as specified and directed.
33Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed.
34Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
35M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc, laid over and including 15mm thick screed bed in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
36M&L for glazed ceramic coloured tiles (joint free) of size450X 350X 7mm/300x600x7mm thick over and including 10mm thick plaster in CM 1:3 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected.
37Taking down GI tubing 15mm bore of any description including cleaning for refixing or removal to store complete all as specified and directed.
38Cutting chases pining in brick, concrete walls built in cement mortar or cement lime mortar making good to facings where required and pointing in CM 1:3to ends or edges of shelves lintels etc and cutting chases for concealed water tubing cuttingnot exc 10 cm girth complete all as specified and directed.
39M&L GI tubing 15mm dia medium grade galvanized, with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
40Taking down GI tubing 20mm bore of any description including cleaning for refixing or removal to store complete all as specified and directed.
41M&L GI tubing 20mm dia medium grade galvanized, with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
42S&F in repair coloured/white viterious china WC (ET) wall mounted withdual flushing cistern incl all necessary fitting such as flush pipe waste pipe fixed as in repair of approvad shade complete all as specified and directed. Make:- Jaquar/Parryware or equivalent as approved by GE.
43S&F in repair vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests including connection to trap, and to flushing pipe, anti syphonage pipe, etc complete making good to floors and complete all as specified and directed.
44S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete all as specified and directed.
45S&F in repair for Plastic water closet seat,white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
46S&F in repair vitreous china half stall urinal white complete all as specified and directed.
47S&F in repair 32 mm bore Low density PVC flexible waste pipe for Wash hand basin/sink etc complete all as specified and directed.
48S&F in repair PVC connections 15 mm size with PTMT nuts of length 600 mm all as specified and directed.
49S&F in repair CP grating with or witout waste hole size 100 mm fixed with white cement in tiles flooring complete all as specified and directed.
50S&F in repair shower health faucet to EWC ,CP brass with minimum 900mm long CP flexible pipe, connection etc complete all as specified and directed.
51S&F in repair CP angle valve 15mm bore fancy type.cast copperalloyscrewed down high pressure,crutch or butterfly handle, screwed both end for pipe or for unions complete chromium plated with suitable type complete all as specified and directed.
52S&F in repair CP stop valves 15mm dia fancy type with long shank and cup(concealed type) screwd down,high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions complete all as specified and directed.
53S&F in repair 600mmx 450mmx 5mm beveled edge looking mirror of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood & fixed to wooden plug with chromium plated screws & cup washer complete all as specified and directed.
54Cutting holes into or through brick walls built in CM and making good in CM 1:3 or cement concrete 1:2:4 type B1, (superficial area exc. 150 Sqcm but not exc. 400 Sqcm),complete all as specified and directed.
55Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
56Dismantling fencing wire mesh, any type complete all as specified and directed.
57Dismantling posts or struts (wood, steel or RCC) any section, including takingout embedded portion and making good disturbed ground complete all as specified and directed.
58S&F chain link MS galvanised fencing, any size or type of standards rails, straining bolts etc including provision of binding wire complete all as specified and directed. Note: Actual weight of chain link fencing shall be measured for payment.
59M&L MS workas in posts or struts infencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riverting etc and similar work confirming to Fe 290Gde E-165 complete all as specified and directed.
60M&L forpreparation of new or previously untreated steei surfaces of any description, over 10 cm in width or girth, not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
61Taking down pipes (any size or pattern) including all fittings shoes, bends, swan neck etc complete all as specified and directed.
62S&F 75mm bore PVC (SWR) pipes, single socked in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed.
63M&L for concrete bed for 150mm bore pipes in PCC 1:3:6 type C-2 using 40mm graded stone aggregate to drain pipes including under and haunching againnst the side oif pipes complete all as specified and directed.
64M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate, in lintels upto 1.5M clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item complete all as specified and directed.
65S&F mild steel workfor framed work as in doors or gates etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening complete all as specified and directed.
66S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
67S&F galvanised 2 strand,steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and strainingand fixing to any type of standard rails,straining bolts,securing and tying at crossings with and provision of galvanised mild steel wire,staple or steel pins etc, complete all as specified and directed.
68S&F exterior tilesof superior qulaity300mmx300mm x 10-12mm thickof approved size/design/shade set & jointed in neat cementslurry & pointed in white orcoloured cementto match as in floor over andincluding20mmthickscreed bedinCM 1:4 complete all as specified and directed.
69S&F of 100mm bore PVC (SWR) pipes, single socked in any length with rubber ring joints fixed to wall including PVC holding clamps complete all as specified and directed.
70S&F energy saving ceiling fan of 1200 mm sweep of 330-370 RPM, 220-240 volts, AC, 50 Hz, ISI marked with five star rating including hanging with the help of fan hook, down rod up to 04 feet and connecting up with provn of 3 core copper flexible cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed.Make : Havells, Model: ES-50 Premium or Usha, Model: Energia Star ISI or Crompton Greaves, Model: Empower 50
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail