Rate Contract For Supply Of Consumables For Cardiac Cath Lab Rate Contract For Supply Of Consumables For Cardiac Cath Lab , Group A1 Puncture Needles ( Adults ) , Item No. 1: Puncture Needle For Vascular Access In Adults • 18 G • 6- 7.5 Cm Long • Shou, blair-Andaman And Nicobar Islands

Department Of Health Services-DHS has published Rate Contract For Supply Of Consumables For Cardiac Cath Lab Rate Contract For Supply Of Consumables For Cardiac Cath Lab , Group A1 Puncture Needles ( Adults ) , Item No. 1: Puncture Needle For Vascular Access In Adults • 18 G • 6- 7.5 Cm Long • Shou. Submission Date for this Tender is 10-02-2022. Coats and Jackets Tenders in blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

30782327
Rate Contract For Supply Of Consumables For Cardiac Cath Lab Rate Contract For Supply Of Consumables For Cardiac Cath Lab , Group A1 Puncture Needles ( Adults ) , Item No. 1: Puncture Needle For Vascular Access In Adults • 18 G • 6- 7.5 Cm Long • Shou
Open Tender
Indian
Andaman And Nicobar Islands
blair
10-02-2022

Tender Details

Rate Contract For Supply Of Consumables For Cardiac Cath Lab Rate Contract For Supply Of Consumables For Cardiac Cath Lab , Group A1 Puncture Needles ( Adults ) , Item No. 1: Puncture Needle For Vascular Access In Adults • 18 G • 6- 7.5 Cm Long • Should Be Compatible With 0.038 Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 2: Puncture Needle Dedicated For Radial Artery Access In Adults • 20- 22 G • 3- 5 Cm Long • Should Be Compatible With 0.021 - 0.025 Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 3: Micropuncture Needle For Vascualar Access In Adults • 20- 22 G • 6- 7.5 Cm Long • Should Be Compatible With 0.018Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 4: Micropuncture Needle For Radial Artery Access In Adults • 20-22 G • 3-5 Cm Long • Should Be Compatible With 0.021-0.025Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Group A2 Introducer Sheaths ( Adults ) , Item No.1: Introducer Sheath For Adults ( Sizes 5 -9Fr. ) - Standard Length • Sizes 5- 9 Fr • 10- 11 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion , Item No. 2: Introducer Sheath With Puncture Needle For Adults ( Size 5- 9 Fr ) - Standard Length • Sizes 5- 9 Fr • 10-11 Cm Long • Packmust Include 18 G, 6- 7.5 Cm Long Puncture Needle • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Item No. 3: Long Introducer Sheath ( Size 5- 9Fr ) – 20-50 Cm Long • Sizes 5- 9 Fr • Sheath Should Be Between 20-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion , Item No. 4:Introducer Sheath For Radial Access Item No. 4. Introducer Sheath Dedicated For Transradial Access • Sizes 4- 7 Fr • Between 7- 11 Cm Long • 0.021 - 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Item No. 5 : Long Introducer Sheath Dedicated For Transradial Access • Sizes 4- 7 Fr • Between 16- 25 Cm Long • 0.021- 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Group A3 Guidewires ( Adults ) , Item No. 1: Ptfe Coated Diagnostic Guide Wire - Regular Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Between 145- 180 Cm Long • Should Be Available As Straight & J Shape Tip • Should Be Available In Variable Lengths Of Flexible / Floppy End • Should Be Available In Variable J Tip Sizes • Should Be Available In Fixed As Well As Movable Core , Item No. 2: Ptfe Coated Diagnostic Guide Wire - Exchange Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be 240- 300 Cm Long • Should Be Available As Straight Or J Shape Tip • Should Be Available In Fixed As Well As Movable Core , Item No. 3: Ptfe Coated Diagnostic Guide Wire - Regular Length, Extra-Stiff Shaft Strength - Amplatz Type • Should Be Available In 0.035 Inches Size And Higher • Should Be 145- 180 Cm Long • Should Be Available As Straight & J Shape Tip , Item 4Hydrophilic Coated Diagnostic Guide Wire –Regular Length / Exchange Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available As Straight Or J Shape Tip Should Be Available In Fixed As Well As Movable Core , Group A4 Diagnostic Catheters ( Adults ) , Item No. 1: Pigtail Catheter - Fda Approved • Sizes 5- 7 Fr • Must Be Fda Approved • Should Be Available In Various Lengths , Item No. 2: Judkins Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Available As Left And Right Judkins Catheters In Various Standard Curves And Lengths • Must Be Fda Approved Jl-50, Jr-50 , Item No. 3: Multipurpose Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Multipurpose Catheter In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 4: Amplatz Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Amplatz Left ( Al ) And Amplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 5: Internal Mammary Diagnostic Coronary Angiography Catheter - Fda Approved • Sizes 5- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Group A5 Diagnostic Catheters ( Adults ) – Special & Trans-Radial Use Cathaters , Item No. 1: Transradial Diagnostic Coronary Angiography Catheters - Fda Approved • Sizes 4- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 2: Special Transradial Diagnostic Coronary Angiography Catheter - Fda Approved • Single Catheter Designed For Both Right And Left Coronary Artery Angiography Dedicated For ‘Trans-Radial Coronary Angiography’ During One Pass • Should Be Available In 4- 6 Fr Ofvarious Curves And Lengths Must Be Fda Approved , Item No. 3: Nih Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 4: Cournard Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 5: Picard Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 6: Cobra Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Group B 1 Ptca Accessories , Item No.1: Ptca Inflation Device- Analog Display • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergonomic And User Friendly Hand Held Design , Item No. 2: Y Connector For Ptca – Rotation Type • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Large Thumb Wheel For Easy Maneuverability • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand , Item No. 3: Y Connector For Ptca – Push And Pull Type • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi-Open And Closed Position • Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand , Item No. 4: Y Connector With Extension Tubing ( Haemostatic Y-Connector With Extension Tubing ) For Ptca- Rotating Mechanism • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Should Have At Least 12 Inch Long, Large Lumen High Pressure Extension Tubing • Should Have An Attached 3-Way Connector To The Extension Tubing • Large Thumb Wheel For Easy Maneuverability • Luer Connector At The Guiding Catheter End Rotating Adapter At The Guiding Catheter End , Item No. 5: Ptca Guide Wire Torquer • Should Hold Guide Wires From 0.009-0.018 Inches • Ergonomic And User Friendly Design , Item No. 6: Ptca Guide Wire Insertion Needle • 20 G Size • 10 -12 Cm Long Metallic Needle • Should Allowto 0.018 Inch Guide Wire , Group B2 Ptca Accessories , Item No. 1: Ptca Inflation Device With Accessory Kit Containing • One Ptca Inflation Device • One Hemostatic Y Connector • One Ptca Guide Wire Torquer One Ptca Guide Wire Insertion Needle , Item No. 2: Disposable Plastic Sterile Control Syringe For Angiography And Ptca • Clear, Glass-Like Plastic Syringe • Markings Up To 10 - 12 Ml • Single Hand Palm And Finger Assisted Maneuverability • Plunger Should Have Resistance Free Movement • Should Have A Stopper With 0.5 Ml Reserve Should Be Individuallypacked , Item No. 3: Disposable Plastic Sterile Luer Lock Syringe For Angiography And Ptca • Clear, Glass-Like Medical Grade Plastic Syringe Made Up Of Three Parts: Barrel, Plunger And Latex Piston • Markings Up To 10 - 12 Ml • Plunger Should Have Resistance Free Movement • Should Have Luer Lock Mechanism For Attachment • Should Be Individuallypacked , Item No. 4: Manifold With Two Side Ports For Angiography And Ptca • Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast • Smooth Resistance Free Uni-Direction Handle / Knob • Should Have Clear Body For Controlled Debubbling • Should Be Available In Both Block And Half-Body Styles • Should Take Pressures Up To 500 Psi , Item No. 5: Manifold With Three Side Ports For Ptca • Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast • Smooth Resistance Free Uni-Direction Handle / Knob • Should Have Clear Body For Controlled Debubbling • Should Be Available In Both Block And Half-Body Styles • Should Take Pressures Up To 500 Psi , Item No. 6: Connector Tubing ( Connecting Between Touhy Borst And Manifold ) • Should Be Between 25- 50 Cm • Should Have Large I.D For Easy Flow Of Contrast • Should Take High Pressure • Should Be Flexible • Should Have Male And Female Hubs , Item No. 7: Connector Tubing ( Connecting Between Y Connector And Manifold ) With Attached Three Way Stop Cock • Should Be Between 20-50 Cm Long • Should Have Large I.D For Easy Flow Of Contrast • Should Take High Pressure • Should Be Flexible • Should Have Attached Three Way Stopcock At One End , Item No. 8: Contrast Tubing ( Connecting Between Contrast Bottle And Manifold ) • Should Have Large I.D For Easy Flow Of Contrast • Should Be Flexible • Should Have Flow Regulating Knobs , Item 9:Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side , Item 10 : High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator , Group B3 Guiding Catheters For Ptca , Item No. 1:Large Lumen Ptca Guiding Catheters Of 6 -8 French Sizes - Fda Approved • Must Have 6Fr. - 8Fr. Guiding Catheters With ? 6Fr. Catheter Must Have I.D Of 0.070 Inch Or More ? 7Fr. Catheter Must Have I.D Of 0.080 Inch Or More ? 8Fr. Catheter Must Have I.D Of 0.090 Inch Or More • Failure To Comply With The Specifications In Any Of The Sizes ( 6Fr, 7Fr, 8Fr ) Will Lead To Rejection As A Whole From This Item. • Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Lima Interventions And Others. • Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) • Should Also Have Availability Of Catheters With Side Holes • Should Also Have Soft Short Tip Catheters • Must Be Fda Approved Quantity -92 ( Jl-20, Jr-20.Al-5, Ebu-30, Mp-3, Lima-3, Ik L-3, Ik R-3 ) , Item No. 2: Ptca Guiding Catheter Dedicated For Transradial Interventions- Fda Approved • Sizes Of5fr, 6Fr And 7Fr • Should Have All Possible Shapes And Variation For Transradial Interventions • Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) • Should Also Have Availability Of Catheters With Side Holes • Should Also Have Soft Short Tip Catheters • Must Be Fda Approved , Item No. 3: Ptca - Coaxial Flexible Guide Catheter Extension Assembly For Enhancing Guide Support In Complex Coronary Interventions ( Guideliner ) • Sizes Of5.5 Fr, 6Fr And 7Fr For Deep Seating Of Guiding Catheter ( Motherand Child Extension ) • Should Be Compatible With Standard Guide Catheters Regardless Of Tip Shape • Must Have Rapid Exchange Convenience • 145-150 Cm Working Length, • Tip Radiopaque Marker , Group B4 Ptca Guidewires , Item No. 1: Ptca Guide Wire - Regular Shaft Support And Floppy Tip • Should Be Available In Both Routine And Exchange Lengths • High Tensile Steel Core • Spring Coil Length 20 Cm • Tip Diameter 0.041” Tip Load 0.5Gm , Item No. 2: Special Ptca Guide Wire – Having Fused Stainless Steel Nd Nitinol Cores • Should Have Elastic Nitinol ( Distal ) Core And Stainless Steel ( Shaft ) Core • Ptca Guide Wire Diameter 0.014” • Nitino; Distal Super Elastic Core For Kink Resistance & Shape Retention • Wire Cores Fused Using “Dua-Core “ Technology • Should Have A “ M Coat” Distal Hydrophilic Coating • Tip Load Of 0.1Gm • Should Be Available In Both Routine ( 180-190Cm ) And Exchange Lengths ( 280-330Cm ) , Item No. 3: Special Polymer Coated Ptca Guide Wire With Distal Spring Coil Having • Hydrophilic Polymer Coating • Non-Tapering Distal Tip • Polymer Sleeve Length Of 20 Cm • “Slip Coat” Coating Over The Distal Spring Coil • Tip Size Of 0.014 & Tip Radiopacity Of 3 Cm • Tip Load 0.8Gm • 180-190Cm , Item No. 4: Special Polymer Coated Tapering Ptca Guide Wire With Distal Spring Coil Having • Hydrophilic Polymer Coating • Tapering Distal Tip To 0.009 Inch • Polymer Sleeve Length Of 20 Cm • “Slip Coat” Coating Over The Distal Spring Coil • Tip Radiopacity Of 16 Cm & Tip Load Of 0.8 Gm 180-190 Cm , Item No. 5: Special Ptca Guide Wire With Tip Madeeeeeeee Up Of Multipl Stiff And Flexible Components • Hydrophilicpolymer Coating • Compositecore ( Rope Coil ) , Micro –Cone Tip • Coil-15 Cm • Tip Radiopacity Of 15 Cm • Tapering Distal Tipto 0.01 Inch-.012 Inch • “Slip Coat” Coating Length 40 Cm • Tip Load Of 3.5 Gm And 4.5 Gm • 180-190 Cm Long , Item No. 6: Special ‘Tapering-Tip’ Ptca Guidewire Dedicated For Pci Of Complex Chronic Total Occlusion • Ptca Guide Wire For Cto With Prfe Coatingover Shaft, Tip Size Of 0.014” • Should Be Available With Various Tip Loads ( Ranging Between 3, 4, 5, 6, 12 Gm ) • Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm • The Tapered Tip Should Be Available Between 0.010-0.012 Inches • Length Of 180-190 Cm , Group B5 Ptca Balloons , Item No. 1: Ptca Balloon ( Semi-Compliant ) – Fda / Ceapproved • Ptca Pre-Dilatation ( Semi Complaint ) ( Rapid Exchange ) • Hypotube Shaft Design , Low Entry Profile ( =0.017” ) • Should Be Available In All Sizesand Lengths • Diameters ( Mm ) :1.2 / 1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0 • Length :Minimum 6-8 Mm To Maximum 20 Mm Or Moe Usfda / Ce ( European ) / Dcgi Certified / Approved , Item No. 2: Ptca Balloon ( Non-Compliant ) – Fda / Ce / Dcgi Approved • High Pressure Monorail Non-Complaint Balloon • Smooth , Rounded Distal Tip Nd No Edge Over Dilatation At Higher Pressure ; With Least Balloon Over Hang At The Edges • Should Be Available In All Sizes , Variable Lengths • Diameter ( Mm ) : 2.5, 2.75, 3.0, 3.25, 3.5, 4 • Length ( Mm ) : Minimum 6-8 Mm To =20Mm • Should Havevery High Rated Bust Pressure • Special Large Ptca Balloon Of Size More Than 4 Mm Also Be Available • Usfda / Ce ( European ) / Dcgi Certified / Approved , Item No. 3: Special Ptca Balloon ( Non-Compliant ) – Fda / Ce / Dcgi Approved Having • Should Have Very High Rated Rated Burst Pressure ( More Than 30 Mmhg ) • Should Be Available In All Sizes, Variable Lengths , Item No. 4: Special Ptca Balloon Catheter With Very Low Crossing Profile -Fda / Ce Approved • Ptca Pre-Dilatation Semi-Compliant Balloon With Lowest Tip Entry Profile Of =0.017” • Lowest Crossing Profile For Crossing Cto Or Difficult To Cross Lesions • Smallest Balloon Size Of 1.0 / 1.1 Mm Diameter And Length Of 6.8 Mm With Single Marker At The Centr Of The Blloon • Other Diameters Of 1.2 / 1.25Mm, 1.5 Mm.5Mm • Other Lengths Of 10-12 Mm, 15-18 Mm • Usfda / Ce ( European ) / Dcgi Certified / Approved , Group B9 Microcatheter, Aspiration Catheters, Snares , Item No. 1: Coronary Microcatheter – Fda / Ce / Dcgi Approved • Distal Diameter Of 108 Fr Or Less • Proximal Diameter 2.6F.Ptfe Coated Inner Layer • Distal Hydrophilic Coating At The Outer Layer • Flexible Tip With Outer Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions • 130-135 Cm Long • 150-160 Cm Long , Item 2 Manual Thrombus Aspiration Catheter And Device • Size 5F, 6F • Catheter Length 135-150 Cm • Hydrophilic Coated Distal Shaft • Maximum Tip Diameter 1.35-1.75 Mm , Item 3 Foreign Body Retrieval Snares ( Coronary ) , All Sizes A. Amplatz Type, Gooseneck B. Cook-Angled Type C .Wire Loop Type , Item 4 Foreign Body Retrieval Snares ( Non-Coronary ) , All Sizes A. Amplatztype, Gooseneck B. Basket Type C. Cook-Angled Type D. Wire Loop Type , Group B7 Hemostasis Devices Mechanism , Item No. 1: Femoral Compression Devices-Disc / Dome Based Compression , Item No. 2: Femoral Compression Devices- Inflatable Balloon Based Compression , Item No. 3: Radial Artery Compressor – Balloon Based , Item No. 4: Radial Artery Compressor - Strap Based , Group C1 Drug Eluting Coronary Stents , Item No. 1 : Sirolimus Coated, Drug Eluting Coronary Stents Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base • C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , ( 2 ) Everolimus Coated Drug Eluting Coronary Stent Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , 2 ) Zotarolimus Coated Drug Eluting Coronary Stent Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , Group C 2 Covered Stent , Item 1 -Covered Stent For Coronary Use ( Balloonexpandable ) All Sizes • All Common Sizes ( 2.8-4.0M And 4.5-4.8 ) , Group C 3 Ptmc Ptmc Balloon & Accessories , Item No. 1: Ptmc Balloon ‘Inoue Type’ With Accessories – Fda / Ce / Dcgi Approved , Item No. 2: Accessories Of Ptmc Balloon ‘Inoue Type’ - Fda Approved A ) Balloon Stretching Tube B ) Guide-Wire ( Left Atrial Coil Wire ) C ) Stylet ( Spring ) D ) Dilator ( Septal ) E ) Ruler F ) Syringe With Attached Tubing G ) Any Other Accessory , Item No. 3: Transseptal Puncture Needle – For Adults • Tapering Tip • Standard Curve • Hub With Angle Indicator , Item No. 4: Introducer Sheath ( Mullins ) For Transseptal Puncture • Should Include A Dilator And Sheath • Dilator Shouldprovide Smooth Transition With Septal Puncture Needle • Should Be Available In Varying Sizes • Radio-Opaque Tip Marker For Precise Visualization Of Sheath • Should Be Kink And Collapse Resistant • Should Be Flexible , Group C4 Miscellaneous , Item 1-Disposable Sterile Patient Drape With Preshaped Circular Access For Both Radial And Femoral Approach During Cardiac Catheterization , Item 2- Sterile Adhesive Transparent Incision Drape; Absorbent And Completely Impervious To Fluids; Sizes 30-40 Cm X 25-40 Cm And 20-25 Cm X 10-15 Cm; Should Be Transparent With A Non-Glare Surface; Should Bebacterial Proof And Water Proof , Item 3- Disposable Sterile Linen / Gauge Swabs Used During Cardiac Catheterization , Item 4-Disposable Pressure Transducer ( Pressure Dome ) , Item 7 Contrast 1 ) Iso Osmolar Non Ionic Contrast Iohexol 350-50, 100 Ml Quantity -100 ( 50 Ml-50, 100Ml-50 ) 2 ) Iso Osmolar Non Ionic Contrast Iodixanol 320-50, 100 ( Visipaque ) Quantity -40 ( 50 Ml-30, 100Ml-10 )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 47 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail