Rate Contract For Supply Of Consumables For Cardiac Cath Lab Rate Contract For Supply Of Consumables For Cardiac Cath Lab , Group A1 Puncture Needles ( Adults ) , Item No. 1: Puncture Needle For Vascular Access In Adults • 18 G • 6- 7.5 Cm Long • Should Be Compatible With 0.038 Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 2: Puncture Needle Dedicated For Radial Artery Access In Adults • 20- 22 G • 3- 5 Cm Long • Should Be Compatible With 0.021 - 0.025 Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 3: Micropuncture Needle For Vascualar Access In Adults • 20- 22 G • 6- 7.5 Cm Long • Should Be Compatible With 0.018Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Item No. 4: Micropuncture Needle For Radial Artery Access In Adults • 20-22 G • 3-5 Cm Long • Should Be Compatible With 0.021-0.025Inch Guide Wire • Should Be Supplied Individually Packed • Needle Should Have Protective Plastic Tube Covering , Group A2 Introducer Sheaths ( Adults ) , Item No.1: Introducer Sheath For Adults ( Sizes 5 -9Fr. ) - Standard Length • Sizes 5- 9 Fr • 10- 11 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion , Item No. 2: Introducer Sheath With Puncture Needle For Adults ( Size 5- 9 Fr ) - Standard Length • Sizes 5- 9 Fr • 10-11 Cm Long • Packmust Include 18 G, 6- 7.5 Cm Long Puncture Needle • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Item No. 3: Long Introducer Sheath ( Size 5- 9Fr ) – 20-50 Cm Long • Sizes 5- 9 Fr • Sheath Should Be Between 20-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion With Smooth And Resistance Free Insertion , Item No. 4:Introducer Sheath For Radial Access Item No. 4. Introducer Sheath Dedicated For Transradial Access • Sizes 4- 7 Fr • Between 7- 11 Cm Long • 0.021 - 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Item No. 5 : Long Introducer Sheath Dedicated For Transradial Access • Sizes 4- 7 Fr • Between 16- 25 Cm Long • 0.021- 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak Of Blood And Aspiration Of Air • Integrated Side Arm With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Group A3 Guidewires ( Adults ) , Item No. 1: Ptfe Coated Diagnostic Guide Wire - Regular Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Between 145- 180 Cm Long • Should Be Available As Straight & J Shape Tip • Should Be Available In Variable Lengths Of Flexible / Floppy End • Should Be Available In Variable J Tip Sizes • Should Be Available In Fixed As Well As Movable Core , Item No. 2: Ptfe Coated Diagnostic Guide Wire - Exchange Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be 240- 300 Cm Long • Should Be Available As Straight Or J Shape Tip • Should Be Available In Fixed As Well As Movable Core , Item No. 3: Ptfe Coated Diagnostic Guide Wire - Regular Length, Extra-Stiff Shaft Strength - Amplatz Type • Should Be Available In 0.035 Inches Size And Higher • Should Be 145- 180 Cm Long • Should Be Available As Straight & J Shape Tip , Item 4Hydrophilic Coated Diagnostic Guide Wire –Regular Length / Exchange Length, Regular Stiffness • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available As Straight Or J Shape Tip Should Be Available In Fixed As Well As Movable Core , Group A4 Diagnostic Catheters ( Adults ) , Item No. 1: Pigtail Catheter - Fda Approved • Sizes 5- 7 Fr • Must Be Fda Approved • Should Be Available In Various Lengths , Item No. 2: Judkins Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Available As Left And Right Judkins Catheters In Various Standard Curves And Lengths • Must Be Fda Approved Jl-50, Jr-50 , Item No. 3: Multipurpose Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Multipurpose Catheter In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 4: Amplatz Diagnostic Coronary Angiography Catheter- Fda Approved • Sizes 5- 7 Fr • Amplatz Left ( Al ) And Amplatz Right ( Ar ) Catheter In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 5: Internal Mammary Diagnostic Coronary Angiography Catheter - Fda Approved • Sizes 5- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Group A5 Diagnostic Catheters ( Adults ) – Special & Trans-Radial Use Cathaters , Item No. 1: Transradial Diagnostic Coronary Angiography Catheters - Fda Approved • Sizes 4- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 2: Special Transradial Diagnostic Coronary Angiography Catheter - Fda Approved • Single Catheter Designed For Both Right And Left Coronary Artery Angiography Dedicated For ‘Trans-Radial Coronary Angiography’ During One Pass • Should Be Available In 4- 6 Fr Ofvarious Curves And Lengths Must Be Fda Approved , Item No. 3: Nih Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 4: Cournard Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths • Must Be Fda Approved , Item No. 5: Picard Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Item No. 6: Cobra Catheter- Fda Approved • Sizes 6- 7 Fr • Must Be Available In Various Standard Curves And Lengths Must Be Fda Approved , Group B 1 Ptca Accessories , Item No.1: Ptca Inflation Device- Analog Display • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge ( Up To 30 Atm ) • Ergonomic And User Friendly Hand Held Design , Item No. 2: Y Connector For Ptca – Rotation Type • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Large Thumb Wheel For Easy Maneuverability • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand , Item No. 3: Y Connector For Ptca – Push And Pull Type • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi-Open And Closed Position • Should Fit Comfortably In Hand And Can Be Manipulated Using Single Hand , Item No. 4: Y Connector With Extension Tubing ( Haemostatic Y-Connector With Extension Tubing ) For Ptca- Rotating Mechanism • Should Accept Catheters Up To 9 Fr. Size ( 0.014To 0.118 Inch ) • Should Have At Least 12 Inch Long, Large Lumen High Pressure Extension Tubing • Should Have An Attached 3-Way Connector To The Extension Tubing • Large Thumb Wheel For Easy Maneuverability • Luer Connector At The Guiding Catheter End Rotating Adapter At The Guiding Catheter End , Item No. 5: Ptca Guide Wire Torquer • Should Hold Guide Wires From 0.009-0.018 Inches • Ergonomic And User Friendly Design , Item No. 6: Ptca Guide Wire Insertion Needle • 20 G Size • 10 -12 Cm Long Metallic Needle • Should Allowto 0.018 Inch Guide Wire , Group B2 Ptca Accessories , Item No. 1: Ptca Inflation Device With Accessory Kit Containing • One Ptca Inflation Device • One Hemostatic Y Connector • One Ptca Guide Wire Torquer One Ptca Guide Wire Insertion Needle , Item No. 2: Disposable Plastic Sterile Control Syringe For Angiography And Ptca • Clear, Glass-Like Plastic Syringe • Markings Up To 10 - 12 Ml • Single Hand Palm And Finger Assisted Maneuverability • Plunger Should Have Resistance Free Movement • Should Have A Stopper With 0.5 Ml Reserve Should Be Individuallypacked , Item No. 3: Disposable Plastic Sterile Luer Lock Syringe For Angiography And Ptca • Clear, Glass-Like Medical Grade Plastic Syringe Made Up Of Three Parts: Barrel, Plunger And Latex Piston • Markings Up To 10 - 12 Ml • Plunger Should Have Resistance Free Movement • Should Have Luer Lock Mechanism For Attachment • Should Be Individuallypacked , Item No. 4: Manifold With Two Side Ports For Angiography And Ptca • Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast • Smooth Resistance Free Uni-Direction Handle / Knob • Should Have Clear Body For Controlled Debubbling • Should Be Available In Both Block And Half-Body Styles • Should Take Pressures Up To 500 Psi , Item No. 5: Manifold With Three Side Ports For Ptca • Large Bore / I.D ( At Least 0.093 Inch ) For Easy Flow Of Contrast • Smooth Resistance Free Uni-Direction Handle / Knob • Should Have Clear Body For Controlled Debubbling • Should Be Available In Both Block And Half-Body Styles • Should Take Pressures Up To 500 Psi , Item No. 6: Connector Tubing ( Connecting Between Touhy Borst And Manifold ) • Should Be Between 25- 50 Cm • Should Have Large I.D For Easy Flow Of Contrast • Should Take High Pressure • Should Be Flexible • Should Have Male And Female Hubs , Item No. 7: Connector Tubing ( Connecting Between Y Connector And Manifold ) With Attached Three Way Stop Cock • Should Be Between 20-50 Cm Long • Should Have Large I.D For Easy Flow Of Contrast • Should Take High Pressure • Should Be Flexible • Should Have Attached Three Way Stopcock At One End , Item No. 8: Contrast Tubing ( Connecting Between Contrast Bottle And Manifold ) • Should Have Large I.D For Easy Flow Of Contrast • Should Be Flexible • Should Have Flow Regulating Knobs , Item 9:Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side , Item 10 : High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator , Group B3 Guiding Catheters For Ptca , Item No. 1:Large Lumen Ptca Guiding Catheters Of 6 -8 French Sizes - Fda Approved • Must Have 6Fr. - 8Fr. Guiding Catheters With ? 6Fr. Catheter Must Have I.D Of 0.070 Inch Or More ? 7Fr. Catheter Must Have I.D Of 0.080 Inch Or More ? 8Fr. Catheter Must Have I.D Of 0.090 Inch Or More • Failure To Comply With The Specifications In Any Of The Sizes ( 6Fr, 7Fr, 8Fr ) Will Lead To Rejection As A Whole From This Item. • Must Have All Possible Shapes Including Catheters: Judkins / Femoral - Left And Right, Extra Back Up Support, Amplatz-Left And Right, Voda, Multipurpose, Lima Interventions And Others. • Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) • Should Also Have Availability Of Catheters With Side Holes • Should Also Have Soft Short Tip Catheters • Must Be Fda Approved Quantity -92 ( Jl-20, Jr-20.Al-5, Ebu-30, Mp-3, Lima-3, Ik L-3, Ik R-3 ) , Item No. 2: Ptca Guiding Catheter Dedicated For Transradial Interventions- Fda Approved • Sizes Of5fr, 6Fr And 7Fr • Should Have All Possible Shapes And Variation For Transradial Interventions • Should Also Have Availability Of Smaller Length Catheters ( 90 Cm Or Less ) • Should Also Have Availability Of Catheters With Side Holes • Should Also Have Soft Short Tip Catheters • Must Be Fda Approved , Item No. 3: Ptca - Coaxial Flexible Guide Catheter Extension Assembly For Enhancing Guide Support In Complex Coronary Interventions ( Guideliner ) • Sizes Of5.5 Fr, 6Fr And 7Fr For Deep Seating Of Guiding Catheter ( Motherand Child Extension ) • Should Be Compatible With Standard Guide Catheters Regardless Of Tip Shape • Must Have Rapid Exchange Convenience • 145-150 Cm Working Length, • Tip Radiopaque Marker , Group B4 Ptca Guidewires , Item No. 1: Ptca Guide Wire - Regular Shaft Support And Floppy Tip • Should Be Available In Both Routine And Exchange Lengths • High Tensile Steel Core • Spring Coil Length 20 Cm • Tip Diameter 0.041” Tip Load 0.5Gm , Item No. 2: Special Ptca Guide Wire – Having Fused Stainless Steel Nd Nitinol Cores • Should Have Elastic Nitinol ( Distal ) Core And Stainless Steel ( Shaft ) Core • Ptca Guide Wire Diameter 0.014” • Nitino; Distal Super Elastic Core For Kink Resistance & Shape Retention • Wire Cores Fused Using “Dua-Core “ Technology • Should Have A “ M Coat” Distal Hydrophilic Coating • Tip Load Of 0.1Gm • Should Be Available In Both Routine ( 180-190Cm ) And Exchange Lengths ( 280-330Cm ) , Item No. 3: Special Polymer Coated Ptca Guide Wire With Distal Spring Coil Having • Hydrophilic Polymer Coating • Non-Tapering Distal Tip • Polymer Sleeve Length Of 20 Cm • “Slip Coat” Coating Over The Distal Spring Coil • Tip Size Of 0.014 & Tip Radiopacity Of 3 Cm • Tip Load 0.8Gm • 180-190Cm , Item No. 4: Special Polymer Coated Tapering Ptca Guide Wire With Distal Spring Coil Having • Hydrophilic Polymer Coating • Tapering Distal Tip To 0.009 Inch • Polymer Sleeve Length Of 20 Cm • “Slip Coat” Coating Over The Distal Spring Coil • Tip Radiopacity Of 16 Cm & Tip Load Of 0.8 Gm 180-190 Cm , Item No. 5: Special Ptca Guide Wire With Tip Madeeeeeeee Up Of Multipl Stiff And Flexible Components • Hydrophilicpolymer Coating • Compositecore ( Rope Coil ) , Micro –Cone Tip • Coil-15 Cm • Tip Radiopacity Of 15 Cm • Tapering Distal Tipto 0.01 Inch-.012 Inch • “Slip Coat” Coating Length 40 Cm • Tip Load Of 3.5 Gm And 4.5 Gm • 180-190 Cm Long , Item No. 6: Special ‘Tapering-Tip’ Ptca Guidewire Dedicated For Pci Of Complex Chronic Total Occlusion • Ptca Guide Wire For Cto With Prfe Coatingover Shaft, Tip Size Of 0.014” • Should Be Available With Various Tip Loads ( Ranging Between 3, 4, 5, 6, 12 Gm ) • Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm • The Tapered Tip Should Be Available Between 0.010-0.012 Inches • Length Of 180-190 Cm , Group B5 Ptca Balloons , Item No. 1: Ptca Balloon ( Semi-Compliant ) – Fda / Ceapproved • Ptca Pre-Dilatation ( Semi Complaint ) ( Rapid Exchange ) • Hypotube Shaft Design , Low Entry Profile ( =0.017” ) • Should Be Available In All Sizesand Lengths • Diameters ( Mm ) :1.2 / 1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0 • Length :Minimum 6-8 Mm To Maximum 20 Mm Or Moe Usfda / Ce ( European ) / Dcgi Certified / Approved , Item No. 2: Ptca Balloon ( Non-Compliant ) – Fda / Ce / Dcgi Approved • High Pressure Monorail Non-Complaint Balloon • Smooth , Rounded Distal Tip Nd No Edge Over Dilatation At Higher Pressure ; With Least Balloon Over Hang At The Edges • Should Be Available In All Sizes , Variable Lengths • Diameter ( Mm ) : 2.5, 2.75, 3.0, 3.25, 3.5, 4 • Length ( Mm ) : Minimum 6-8 Mm To =20Mm • Should Havevery High Rated Bust Pressure • Special Large Ptca Balloon Of Size More Than 4 Mm Also Be Available • Usfda / Ce ( European ) / Dcgi Certified / Approved , Item No. 3: Special Ptca Balloon ( Non-Compliant ) – Fda / Ce / Dcgi Approved Having • Should Have Very High Rated Rated Burst Pressure ( More Than 30 Mmhg ) • Should Be Available In All Sizes, Variable Lengths , Item No. 4: Special Ptca Balloon Catheter With Very Low Crossing Profile -Fda / Ce Approved • Ptca Pre-Dilatation Semi-Compliant Balloon With Lowest Tip Entry Profile Of =0.017” • Lowest Crossing Profile For Crossing Cto Or Difficult To Cross Lesions • Smallest Balloon Size Of 1.0 / 1.1 Mm Diameter And Length Of 6.8 Mm With Single Marker At The Centr Of The Blloon • Other Diameters Of 1.2 / 1.25Mm, 1.5 Mm.5Mm • Other Lengths Of 10-12 Mm, 15-18 Mm • Usfda / Ce ( European ) / Dcgi Certified / Approved , Group B9 Microcatheter, Aspiration Catheters, Snares , Item No. 1: Coronary Microcatheter – Fda / Ce / Dcgi Approved • Distal Diameter Of 108 Fr Or Less • Proximal Diameter 2.6F.Ptfe Coated Inner Layer • Distal Hydrophilic Coating At The Outer Layer • Flexible Tip With Outer Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions • 130-135 Cm Long • 150-160 Cm Long , Item 2 Manual Thrombus Aspiration Catheter And Device • Size 5F, 6F • Catheter Length 135-150 Cm • Hydrophilic Coated Distal Shaft • Maximum Tip Diameter 1.35-1.75 Mm , Item 3 Foreign Body Retrieval Snares ( Coronary ) , All Sizes A. Amplatz Type, Gooseneck B. Cook-Angled Type C .Wire Loop Type , Item 4 Foreign Body Retrieval Snares ( Non-Coronary ) , All Sizes A. Amplatztype, Gooseneck B. Basket Type C. Cook-Angled Type D. Wire Loop Type , Group B7 Hemostasis Devices Mechanism , Item No. 1: Femoral Compression Devices-Disc / Dome Based Compression , Item No. 2: Femoral Compression Devices- Inflatable Balloon Based Compression , Item No. 3: Radial Artery Compressor – Balloon Based , Item No. 4: Radial Artery Compressor - Strap Based , Group C1 Drug Eluting Coronary Stents , Item No. 1 : Sirolimus Coated, Drug Eluting Coronary Stents Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base • C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , ( 2 ) Everolimus Coated Drug Eluting Coronary Stent Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , 2 ) Zotarolimus Coated Drug Eluting Coronary Stent Diameter :2.25-4.5 Mm Length :8Mm -48Mm Rates To Be Quoted Separately For: • Cobalt Chromium Base • Platinum Chromium Base C ) Stainless Steel Base-Usfda / Ce ( Eueopen ) / Dcgi Certified / Approved , Group C 2 Covered Stent , Item 1 -Covered Stent For Coronary Use ( Balloonexpandable ) All Sizes • All Common Sizes ( 2.8-4.0M And 4.5-4.8 ) , Group C 3 Ptmc Ptmc Balloon & Accessories , Item No. 1: Ptmc Balloon ‘Inoue Type’ With Accessories – Fda / Ce / Dcgi Approved , Item No. 2: Accessories Of Ptmc Balloon ‘Inoue Type’ - Fda Approved A ) Balloon Stretching Tube B ) Guide-Wire ( Left Atrial Coil Wire ) C ) Stylet ( Spring ) D ) Dilator ( Septal ) E ) Ruler F ) Syringe With Attached Tubing G ) Any Other Accessory , Item No. 3: Transseptal Puncture Needle – For Adults • Tapering Tip • Standard Curve • Hub With Angle Indicator , Item No. 4: Introducer Sheath ( Mullins ) For Transseptal Puncture • Should Include A Dilator And Sheath • Dilator Shouldprovide Smooth Transition With Septal Puncture Needle • Should Be Available In Varying Sizes • Radio-Opaque Tip Marker For Precise Visualization Of Sheath • Should Be Kink And Collapse Resistant • Should Be Flexible , Group C4 Miscellaneous , Item 1-Disposable Sterile Patient Drape With Preshaped Circular Access For Both Radial And Femoral Approach During Cardiac Catheterization , Item 2- Sterile Adhesive Transparent Incision Drape; Absorbent And Completely Impervious To Fluids; Sizes 30-40 Cm X 25-40 Cm And 20-25 Cm X 10-15 Cm; Should Be Transparent With A Non-Glare Surface; Should Bebacterial Proof And Water Proof , Item 3- Disposable Sterile Linen / Gauge Swabs Used During Cardiac Catheterization , Item 4-Disposable Pressure Transducer ( Pressure Dome ) , Item 7 Contrast 1 ) Iso Osmolar Non Ionic Contrast Iohexol 350-50, 100 Ml Quantity -100 ( 50 Ml-50, 100Ml-50 ) 2 ) Iso Osmolar Non Ionic Contrast Iodixanol 320-50, 100 ( Visipaque ) Quantity -40 ( 50 Ml-30, 100Ml-10 )