Special Repair To Bldg No P 346 Adm Bldg Of Asce Raiwala At Mil Station Raiwala Under Age I Raiwala, raiwala-Uttarakhand

Military Engineer Services-MES has published Special Repair To Bldg No P 346 Adm Bldg Of Asce Raiwala At Mil Station Raiwala Under Age I Raiwala. Submission Date for this Tender is 05-02-2022. Building Work Tenders in raiwala Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

30763449
Corrigendum : Special Repair To Bldg No P 346 Adm Bldg Of Asce Raiwala At Mil Station Raiwala Under Age I Raiwala
Open Tender
Indian
Uttarakhand
raiwala
05-02-2022

Tender Details

Special Repair To Bldg No P 346 Adm Bldg Of Asce Raiwala At Mil Station Raiwala Under Age I Raiwala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 27000.0 /-
Tender Value
INR 13.50 Lakhs /-

BOQ Items

Name of Work: SPECIALREPAIR TOBLDG NO P-346 (ADM BLDG) OF ASCE RAIWALA AT MIL STATION RAIWALA UNDER AGE(I) RAIWALA
Sl. No. Item Description
1Removal ofexisting roof treatment i.e APP membrane, brick tiling incl mud mortar and open up RCC roof slab including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any other loose material complete all as specified and directed. Note :- The work is required to be carried out at non-accessible roof for double storey . The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
2M&L PCC 1:2:4 type B-0 (using 12.5 mm graded stone agg) mixed withliquid water proofing(as per manufacturer direction )over and including one coat of cement slurry admixed with acrylic bonding compound SBR latex liquid primer as to be used for bonding of new concrete /mortar to old surface as per manufacturer instructionand finishing the surface even and smooth using extra cement as in roof padding and sunken floor treatement to receive roof treatment complete all as specified and directed. Note :- (SBR) Latex liquid polymer will be measured and paid seperately.Note :- The work is required to be carried out at non-accessible roof for double storey . (ii) The contractor shall make arrangement of scoffolding,safety & security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items .
3Supply only SBR Latex liquid polymer of approved make. complete all as specified and directed.
4M&L of water proofing treatment to non-accessibleroof slabwith APP based modified polymeric membrane as per manufacturer’s instructionswith following course of description below :- (a)Applying a priming coat of bituminious primer @ 0.30 Kg /Sqm for each coat, till the surface is properly impregnated. (b) Providing APP based 5 layer polymeric membrane minimum weighing 3 .6Kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on primed surface by forced applications as per the manufacturer"s instructions with side over lap of 75 mm and end overlap of 100 mm. All overlap joints shall be sealed thoroughly by thermo fusing both the membrane layer (torching overlap by propane or butane gas torch ) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic layer (c) Apply two coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance Note : 1. The work of water proofing treatment shall be got executed through authorised applicator of the manufacturer only and 10 year company back warranty to be submitted by contractor 2. The work is required to be carried out at non-accessibleroof slab for double storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
5M& L for concrete angle-fillets with a radiaus of 75mm at junction between roofs/chajja/top surface of projected cub boards and vertical faces of wall ( parapet and other walls) to ease up about corners and over chajjas with PCC 1:2:4 type B-0 (Using 12.5mm stone aggregate) mixed withSBR Latex liquid polymer as per manufactur direction incl using form work (straight or curved ) as required complete all as specified and directed . Note - The work is required to be carried out up to double storey . The contractor shall make arrangement of scoffolding,safety & security of workers. The rates quoted shall deemed to be included for these items .
6Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.complete all as specified and directed.
7Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm butnot exceeding 4.0 Sq.m each.complete all as specified and directed.
8Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each .complete all as specified and directed.
9S&F Powder Coated of any colour(minimum thickness of powder coating 50 micron), aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed.
10S&F Powder Coated of any colour (minimum thickness of powder coating 50 micron), aluminium window and ventilator shutters, side / top hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
11S&F Powder Coating of any colour (minimum thickness of powder coating 50 micron), aluminium door shutters, aluminium section weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges,anodised aluminium snap beading, screws etc. complete all as specified and directed.
12S & F for Glazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil puttyor aluminium or PVC beading insquares exceeding 0.5 Sq.m in each pane.complete all as specified and directed.
13M & L 9 mm thick both sides prelaminated Particle board, exterior grade, fixed with screws to frame work in aluminium / timber , partitions, etc.complete all as specified and directed.
14S&F double action floor spring hydraulically regualted made up of aluminium 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty. complete all as specified and directed.
15S&F aluminium (die cast) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repairs. complete all as specified and directed.
16S&F 4 leverMortice lock Brass vertical typesize 100 mm. complete all as specified and directed.
17M&L Second class hard wood plain, solid, straight chowkats (SAL) and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints.Complete all as specified and directed by Engineer-in-charge
18MS Fastner of size 200 to 250mm for fixing wooden door frame and like in postion complete all as specified and directed.
19S & F 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.complete all as specified and directed.
20S&F for 0.9 mm thick decorative laminates surface finish one side, colour and pattern as approved, fixed with approved adhesive as per manufacturer instructions. Complete all as specified and directed
21S&F 100mm X 63mm Single Rebate Factory made 100 % Solid WPC door Frame made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cbm & Manufactured by an ISO: 9001-2015 certified company, all as per specification. The door frame should be Water Proof , Termite Proof , Fire Retardent and having excellent screw holding capacity. complete all as specified and directed. Make ENCHON( Kumar Arch Tech P Ltd/ Floresta/Achidply
22Providing 30mm thick molded WPC factory made 1005 solid door ( conforming aas per IS : 4020) made from 100% lead free single extruded with 2,4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600 kg/cum. manufactured by an ISO: 9001-2015 certified company. The door should be water proof, termite proof, fire retardent and having screw holding capasity complete all as specified and directed.Make ENCHON( Kumar Arch Tech P Ltd/ Floresta/Achidply
23Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated (PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick inDouble rebate windows in which both glazed shutter andflymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutterand wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each,PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm .Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screwsafter drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
24S & F for Aluminium anodized barrel tower bolt of 300 mm lengthofextruded section .
25S & F for Aluminium handles,cast type, anodised 150 mm long, all as specified and directed.
26S&F Stainlessnon megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed by Engineer in Charge
27S & F for stainlees steel sliding door bolt, of size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy.
28S & F for Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm.complete all as specified and directed.
29S&F in repair stainless steel non magnetic curtain rod 25 mm dia& 1.20mm thick with fixing brackets and decorative type brass knobs both side of each rod.complete all as specified and directed. Note: - Measurement will be taken between end point of knobs
30M & L in repair for Aluminiumdoor seal upto 1200 mm long onbottom of door. complete all as specified and directed.
31S&F in repairs to aluminium Hat and coat hooks,solid body, 175mm to 250 mm complete all as specified and directed.
32Preparation of Newwood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint over a coat of pinkprimer. complete all as specified and directed.
33Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality over a one coat of pink primer complete all as specified and directed.
34Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one.complete all as specified and directed.
35S & F for Glazing with plain sheet glass, ordinary quality, 5.5 mm thick and glazing with oil puttyor aluminium or PVC beading insquares n. exceeding 0.5 Sq.m in each pane.complete all as specified and directed.
36S & F for Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil puttyor aluminium or PVC beading insquares notexceeding 0.5 Sq.m in each pane.
37Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets.complete all as specified and directed.
38S&F solid PVC wall panelling consisting of 5 mm thick prelaminted one side PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawingin any position with screws complete and as directed by Engineer-in-Charge
39S&F 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing.complete all as specified and directed.
40Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided forincluding removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
41M&L forRCC 1:2:4 type B1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc.complete all as specified and directed.
42M&L forReinforced Cement Concrete Type B-1 1:2:4 (using 20 mm gradedstone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
43M&L RCC 1:2:4 type B1 (using 20 mm graded aggregate) in Chajjas / fins/ facia for minor repair incl form work incl one coat of SBR latex as bonding of old concrete to new concrete.complete all as specified and directed. Note : 1. The work is required to be carried out at for single storeyed.The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
44M & L for Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar worknot exce 200 mm thick.complete all as specified and directed.
45M&L for mild steel TMT bars10mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
46M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
47Dismantlingfloor hearth or wall tiling including cement mortar bedding (but not backing), removingincluding removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
48M&L forcoloured vitrified tiles of any design and pattern, 600x600x9 to10 mm thick, as in floor etc incl 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B1b with average water absorption between 0.08% to 3%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 4.0% (Max deviation). Centre & Edge curvature and warpage + 0.20% (Max Deviation). Breaking strength 1200 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) Complete all as specified and directed
49M&L for coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (square/rectangular) area of each tile exe 0.11 sqm but not exe 0.18, in floor etcincl 15mm thick screed bed in CM 1:6 , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
50M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mmthick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I) .Complete all as specified and directed
51Dismantling of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelvesetc.Complete all as specified and directed
52M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
53Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specifiedand directed.
54M&L Providing cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and fair complete all as specified and directed.
55Supply only 4mm thick glass dividing strip of figured glass, pin headed type, 73mm wide insereted in position completed all as specified and directed
56Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.complete all as specified and directed.
57M & L for Brick work with sub-class `B" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6. complete all as specified and directed.
58M & L for Brick work with sub-class `B" bricks, straight or curved on plan to any radius in half brick wallbuilt in cement mortar 1:4. complete all as specified and directed.
59Taking down cement plaster, terrazzo dado in any thickness from brick or stonewalls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc including removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
60M&L rendering 10 mm thick in CM 1:3 in ceiling finished even and smooth (without using extra cement) . complete all as specified and directed.
61M&L forpreparation of new plaster surface on ceiling and applying two coats of arclyc Emulsion on ceiling over above one coat of wall putty incl preparation of surfaces.complete all as specified and directed
62M&L forComplete removal of existing treatment on ceiling surface by scrapingwashing and applying two coats of arclyc Emulsion on ceiling over above one coat of wall putty incl preparation of surfaces.complete all as specified and directed
63M&L Rendering 15 mm thick cement plaster on concrete or brick walls in two coatsfirst coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & fair. complete all as specified and directed. Note :- Integral water proofing liquid will be measured and paid seperately.
64Supply only water proofing compound.ISI markedcomplete all as specified and directed.
65M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:-1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v).The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
66M&L for preparation of old decorated surface of exterior wall by removing existing treatment with mechanical sander (rpm 1500-2700)along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v).The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
67M&L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & fair. complete all as specified and directed.
68M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer incl a one coat of wall care putty using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:-(i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemperThe cost of all material T&P and labour required for preparation of surface are deemedto be included in the ratesquoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/AGE (I)before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v).The colour / shade will be all as approved by GE / AGE (I)
69M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700)along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over a one coat of wall care putty using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge. Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v).The colour / shade will be all as approved by GE / AGE (I)
70Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs .complete all as specified and directed.
71S&F Rotational mouldedpolyethylene water storage tank (ISI Marked only)including, plastic lid cover ( ISIMarked) , doublelayered, cylindrical vertical with closed top hoisted and fixed in position of capacity 1000 ltrs including making connections,20 mm dia ball valves( ISI Marked heavy duty )high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe anf fixed (min wt 210 gram) complete all as specified in SSR Part I.complete all as specified and directed.
72Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia .complete all as specified and directed.
73Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia .complete all as specified and directed.
74M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
75M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
76Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed
77S & F 20 mm dia Gun Metal (ISI Marked), globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs.complete all as specified and directed.
78S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions. complete all as specified and directed.“Make: Jaquar Cat No-MQT-526NKN, Hindware cat No-F200005 ,Prayag Cat No-6510 (Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
79S & F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.complete all as specified and directed.“Make: JJaquar Cat No-MQT-512KN, Hindware cat No-F200001 ,Prayag Cat No-6502(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
80S & F in repairs 15mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts, screwed for iron pipe.complete all as specified and directed. “Make: Jaquar Cat No-MQT-508KN, Hindware cat No-F200011 ,Prayag Cat No-6509(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
81S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms)./ complete all as specified and directed. “Make: Jaquar Cat No-AEC 1111N, Hindware cat No-F880005 ,Prayag Cat No-BA-01(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
82S & F , in repair, corner shelf fancy type made of 6 to 7 mm thick sheet glass of size 250mmx250mm fixed with chromium plated brackets complete all as specified and directed.Jaquar Cat No-ACN1173, CERA cat No-F505101 ,Prayag Cat No-BEA-44
83S&F in repair for PVC Connections 15mm size (ISI Marked)with PTMT nuts of length 600 mm. complete all as specified and directed.
84S&F in repairWash basins with pedestal (full) vitreous chinaany size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including brass chromium plate waste fitting Complete all as specified and directed.Jaquar Cat No-ECS-WHT-801 (WHB) & ECS-WHT-301(PEDESTAL), Hindware Cat No-Mario 10087 (WHB) & 11003(PEDESTAL) ,Cera Cat No-S2040120(WHB) & S2090113(PEDESTAL)
85S & F in repairs for Grating ,round 127 mm diachromoum plated or suitable dia as requied at site (ISI Marked). complete all as specified and directed.
86S&F in repair to 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. complete all as specified and directed.
87S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), lowlevel , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed Sleek fresh dual flush of Hindware Model No star white size 47.6x15.5x32,Parryware Cat No 8177*, CeraCat No B1810110
88S&F in repairs Vitreous china Squatting pan , "Orissa pattern, size 580x440 mm white, with integral foot restexcluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor .complete all as specified and directed.
89S & F Vitreous china urinal, bowl type flat back of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipecomplete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws,complete all as specified and directed.
90S&Fin reapir Vitreous China coupled wash down water closet pan (Pedestal pattern) with flushing cistern incl seat and cover (complete set) fixed with brass screw and necessary fittings Complete all as specified and directed..Jaquar Cat No-AIS-WHT-01754S220SPPSMZ, Hindware Cat No-20101(S-22) (EWC) & 21054 (Cistern) ,Cera Cat No-S1013136.(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
91S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered "Hot" or "Cold" ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair.complete all as specified and directed.Jaquar Cat No-MQT-516AKN, Hindware cat No-F200014 ,Prayag Cat No-6550(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
92S&F in repairs Health Faucet with hose & hook (complete set) fixed to angle / stop cock 15 mm dia complete all as specified and directed.. Jaquar Cat No- ALD 573,Hindware CatNo F160068, Parryware Cat No T9961A1 (Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
93S&Fin repairstoilet paper chromium plated fixed to wall with chromium plated (CP) brass screws. complete all as specified and directed. Jaquar Cat No- ACN-1153N ,Hindware model No F 880003, Parryware model No T6514A1,(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
94S&Fin repairs towel ring chromium plated fixed to wall with chromium plated (CP) brass screws complete all as specified and directed.Make - JaquarCat part no AEC-1121N , Hindware cat No-F880007, &Prayag Cat No-BA 02(Note- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site .
95S&F repair 32 mm dia lowdensity polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc.complete all as specified and directed.
96Dismantling of cast iron or reinforced concrete drain pipes up to 100mm dia , jointed in cement mortar and taking out of trenches if required .complete all as specified and directed.
97S & F 75 mm bore PVC (SWR) Soil ( ISIMarked), waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
98S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. ( ISIMarked)complete all as specified and directed.
99S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints ( ISIMarked) fixed to walls.complete all as specified and directed.
100S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed( ISIMarked)in any length with rubber ring joints fixed to walls.complete all as specified and directed.
101S & F 75 mm bore PVC (SWR) bends of any radius ( ISIMarked)complete all as specified and directed.
102S & F PVC (SWR) reducers of size 110 mm x75 mm ( ISIMarked) . complete all as specified and directed.
103S & F 75 mm bore PVC (SWR) Vent Cowl ( ISIMarked) . complete all as specified and directed.
104S & F 75 mm bore PVC (SWR) Multi floor trap( ISIMarked) including jointing with solvent cement. complete all as specified and directed.
105S & F 110 mm bore PVC (SWR) P Trap ( ISIMarked) . complete all as specified and directed.
106S & F 75 mm bore PVC (SWR) floor Trap ( ISIMarked) , plain with grating inclding jointing with solvent cement .complete all as specified and directed.
107S&F in repairstackclamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stamp includingbolts and nuts and securing ends of stays to walls or roof for 110 mm pipe, complete all as specified and directed.
108S&F in repairstackclamps out of 50mmx 5 mm flat iron and 16 mm dia round iron stamp includingbolts and nuts and securing ends of stays to walls or roof for 75 mm pipe, complete all as specified and directed.
109Dismantling and taking down U/Spoint wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
110Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
111Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified and directed.
112Material & Labour for Point Wiring for one light Point/ceilingfan/exhaust fan point/ call bell point controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia medium grade(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii)If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
113One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
114All as per item no 112but forOne 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed .
115All as per item No 112abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point.complete all as specified and directed.
116S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzall as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
117Supply and fix Modular switch 1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 11/ Indoasian Cat No: 800002 or equivalent make of L&T /Havells
118Supply and fix Modular socket1 way 16 Amps, 1 module, 230 volts, 50 hz white/ivory finish all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 12/ Indoasian Cat No: 800020 or equivalent make of L&T /Havells
119Supply and fixModular Socket outlet, 16A - 6 pin combined, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge. Make: Legrand cat No: 6734 55/ Indoasian cat No 800022 or equivalent make of L&T/Havells
120M&L ceiling rose 3 terminal / PVC/ polycarbonate,ISI marked 230 volts,50 Hz isolated body all as specified and directed Make : Anchor Cat part No.14307/ Cona Cat Part No.7091 / or equivalent in Havells.
121S & F bell push Modular single pole,one way 6 Amps , 1 module, ISI marked, 230 volts, 50 hzall as specified and directed by Engr-in-Charge.Make: Legrand cat No: 6734 06 / Indoasian cat no: 800007 or equivalent make of L&T /Havells.
122S&F bell ding dong elelctric 230V ACsingle pole all as speccified and directed Make : Anchor cate part No doorbell-10489-1B or equavalent in Cona / Havells
123Supply and fix Bell multi music type, AC. 230 volts all as specified and directed Make : Anchor / Cona/Havells.
124Supply and fix Bell AC, 230 volts all as specified and directed by Engr-in-charge MMake : Anchor / Cona/Havells.
125Supply and fix surface mounted LED luminiare, 20 watt with all accessories having polycarbonate extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt,Inverter LED batten with square profile, inbuilt Lithium Ion battery with charging time 8-10 hours and back up time up to 4 hours, 6500 K internally pre-wired through flexible wire connecting with ceiling rose all as directed. Make: Havells cat No: LHEXACP7FN1W020 or equivalent model of Crompton Cat No: LCTLN-20-CDL /Shakti Cat No: SZSLBMX020 Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period.
126Supply and fix surface mounted LED luminiare, 10 watt with all accessories having polycarbonate extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt,Inverter LED batten with square profile, inbuilt Lithium Ion battery with charging time 8-10 hours and back up time up to 4 hours, 6500 K internally pre-wired through flexible wire connecting with ceiling rose all as directed. Make: Havells cat No: LHEXACP7FN1W010 or equivalent model of LCTLN-10-CDL /Shakti cat No: SZSLBMX010Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period.
127Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copperonductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed by Eng-in-Charge. Make:-SZPCLPM020 of Shakti /LTESSG20WLED of C&S/Havells Cat No: LHEXAYP7PN6K020/ Crompton Cat No: TRP-400-20-57-SL-LM-NSR (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No(iv) Connection toluminaire shall be done in suitable PVC connector wwithin the bracket/luminaire end and are inclusive in above.
128Supply and fixing round shape 18 watt 230 volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holder, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed Make Shakti Cat Part No. SZSDRM X 018/ Havells Cat Part No. LHEAAHP71L1W018/C&S Corona -RND/18W/W
129Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting ISI markedcomplete all as specified & directed Make : Anchor/ Cona / Havells
130Supply and hanging ceiling fan five star rating with double ball bearing 350 RPM, 1200 mm sweep, working on 140-285 Volts AC 50 Hz, PF 0.99 with super energy efficient BLDC motor & power consumption shall not more than 28 W under standard test condition along with down rod, canopy and all accessories, with smart remote control, all as supplied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 volts grade of suitable size (not less than 1.5 sqmm) and length including and making necessary electric connection etc all as directed. Note: Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 3 years for any defects developed during the period. .Make: Havellls/Crompton/Philips
131Supply and fix Exhaustfan heavy duty size 450 mm sweepsingle phase and 900 RPM with bracket , louvers, opening/core cutting the wall of any type bricks or stone and grouting with MS rag bolts etc making surface good and connecting from ceiling rose/connector to fan with and including provn of PVC insulated and sheathed three core copper conductor flexible cable FRLSH of size not less than 1.5 Sqmm sufficient length complete all as specified and directed by Engr-in-Charge. Make: Havellls/Crompton/Philips
132M & L Sheet metal MCB DB TPN 4 way,415 Volts, vertical double door type powder coated with 200 Amps rated copper bus bar, neutral link, earth rail & din rail, ISI marked for fixing of MCBs complete. Note: MCBs shall be of uniform make and incoming and outgoing cables should be fix with suitable size of cable ferrules copper for out going/lugs for incoming complete all as specified and directed.
133S & F MCB TPN 40-63 Amps "C" curve breaking capacity 10 KA, 415 volts, 50 Hz with ISI marked with cable connection and copper lugs complete all as specified and directed.
134M & L Sheet metal MCB DB SPN 12 way 240 Volts, double door type powder coated with 200 amps rated bus bar, neutral link, earth rail & din rail, ISI marked for fixing of MCBs.complete all as specified and directed.Note: (i) MCBs measured and paid separately under respective items. (ii) MCBs shall be of uniform make.
135Supply and fixing MCB SPN 10-32 Amps rating 240 volts, 10 Ka, "c" curve miniature circuit breaker(MCB), ISI marked, 50 Hz with cable connection and copper lugs complete with connection testing. complete all as specified and directed.
136Supply and fixing 240 v, 10 KA "C" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amps, ISI marked, 50 hz with cable connecting and copper lugs complete with connection testing. complete all as specified and directed.
137Supply and fixing 240 V, 10 KA "C" curve miniature circuit breaker (MCB) of single pole and current carrying capacity 2-4 Amps, ISI marked, 50 hz with cable connecting and copper lugs complete with connection testing. complete all as specified and directed.
138M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area) of single core unsheathed PVC insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metalic rigid PVC Conduit of size 20 mm or higher medium grade including necessary conduit accessories concealed on wall/surface only on roof/colomn above false ceiling) type 4.0 sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed. (Note: Three runs of Phase , Neutral, earth wire and PVC conduit measured as one RM or One unit length)
139Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level connected by 4 mm GI wire as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM and charcoal, dust and common salt all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
140Material and labour for fixing or passing through pipe, laid in trenches, fixed on wall,LT panel board,XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 50 sqmm 4 core with required aluminium cable lugs, lugs should properly crimp with crimpping tools,heat shrink joints, Colour code heat shrink sleeves at both cable ends , cable gland for cable safety when passing through panel holes, including laying cable route indicators of suitable size RCC or steel type as per site requirementall as specified and directed. by Engr-in-charge. Note:(i)GI tubing requiredshall be measured and paid separately under relevant item of sch as supply only,
141Taking down old unserviceable service/UG cable ofany size from building complete all as specified and directed.
142Excavation in trenches for taking out/laying of cable and pipe line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/loose soil. complete all as specified and directed.
143Returning, filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in each layer in any type of soil.complete all as specified and directed.
144Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. complete all as specified and directed.
145Material and Labour for sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed. (Note:- Punned thickness shall be considered for payment purpose.)
146M & L for cable protection bricks common burnt clay sub class "B" designation 75 for protection of UG cable laid in trenches all as specified and directed at site complete all as specified and directed.
147M&L for road cutting and making good with PCC 1:3:6 type C-2(using 40 mm graded stone aggregate) ofminiumsize 150mm X 100mm in respect ofwidth and thickness complete all as specified and directed.
148Supply, laying & joined Galvanised Tubing 50 mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc for cable protection complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail