Horizontal Extension For 24 Bedded Hybrid Ccu With Temporary Shed At Uluberia Sub-Divn. Hospital., howrah-West Bengal

Public Works Department-PWD has published Horizontal Extension For 24 Bedded Hybrid Ccu With Temporary Shed At Uluberia Sub-Divn. Hospital.. Submission Date for this Tender is 09-02-2022. Building Work Tenders in howrah West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

30762623
Horizontal Extension For 24 Bedded Hybrid Ccu With Temporary Shed At Uluberia Sub-Divn. Hospital.
Open Tender
Indian
West Bengal
howrah
09-02-2022

Tender Details

Horizontal Extension For 24 Bedded Hybrid Ccu With Temporary Shed At Uluberia Sub-Divn. Hospital.

Key Value

Document Fees
Refer document
EMD
INR 23990.0 /-
Tender Value
INR 11.99 Lakhs /-

BOQ Items

Name of Work:- Horizontal Extension for 24 beddedHybrid CCU with temporary shed at Uluberia Sub-Divn. Hospita.
Sl. No. Item Description
1Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
2(a) Depth of excavation not exceeding 1,500 mm.
3Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
4(a) With earth obtained from excavation of foundation.
5Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
6(b) Do - by Fine sand
7Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints withlocal sand.
8Cement concrete with graded stone ballast (40 mm. size) excluding shuttering.
9(A) In Ground floor. (A) [Pakur Variety]
10(a) 1:3:6 proportion
11Ordinary Cement concrete (mix 1:1.5:3)with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.Pakur Variety.
12A) In ground floor
13a) Pakur Variety
14Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
15(f) 25 mm to 30 mm shuttering without staging in foundation
16(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
17Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
18(a)For works in foundation and upto roof of ground floor/upto 4 m
19Tor steel/Mild steel:-
20II. Other than SAIL/ TATA/RINL
21(JSW/JSPL/SHYAM…etc.)
22Brick work with 1st class bricks in cement mortar (1:6)
23(a) In foundation and plinth
24(b) In superstructure, ground floor
25Labour for Chipping of concrete surface before taking up Plastering work.
26Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]
27(i) With 1:6 cement mortar(b) 20 mm thick plaster
28(c) 15 mm thick plaster
29Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.
3025mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).
31Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brandconforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) = 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer)
32ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
33Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc
34(B) Wall
35With Sand Cement Mortar (1:3)15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.
36(a) Area of each tile above 0.09 Sq.m
37(ii) Other than Coloured decorative including white
38(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.
39(ii) Grill weighing above 16 Kg./sq.mtr and above
40M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.
41i) For roof truss works
42a) Span up to 12 Mtr
43M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)
44Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.
45(i) 16 mm dia bolt
46(a) 300 mm long
47Supplying, fitting and fixing PUF insulated sandwich roof panels of total thickness not less than 30 mm having pre-coated Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5 mm for top & 0.4mm for bottom with minimum yield stress 550 MPa and Zinc coating of minimum 120 gsm as per IS: 277-1992 as skin on both side of PUR core (density 40 ± 2 kg/cum & self extinguishing) affixed to generate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 and external face is made corrugated in shape for GI and PUR both material. The crest height of the panel shall be of 28 mm to 35 mm minimum with 200 to 250mm c/c pitch. The Pre-coated sheet shall contain 5-7 microns epoxy primer over zinc coating on both side of the sheet and polyester top coat 15-18 microns. The PPGL/ PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches while transportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm & above self drilling self tapping (SDST) screw with rubber washer including all types of fasteners, ridges and end capping as per structural design & direction of Engineer-in Charge complete in all respect.
4830 mm thickness panel for roofs
49A) Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size 595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor.
50A) False Ceiling (with 6mm thick Fibre Cement Designer Board and E-Grid T- 2430).
51Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
52(b) Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand ( 1.5 mm.thick )
53Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor)
54(a) Two Coat
55i) Water based interior grade Acrylic Primer
56Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)
57(a) Two Coat
58ii) Luxury Quality
59Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In ground floor :-
60(b) Twocoat.
61Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
62In Ground floor [ 2 coats.]
63b) Premium 100% Acrylic Emulsion/G.F
64Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
65Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:
66(b) On steel or other metal surface/ With super gloss (hi-gloss)
67(i) Two coats (with any shade except white)
68Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.
69A) UPVC Pipes :-
70(b)100 mm. Dia.
71B) UPVC Fittings :-
72a) Plain Tee.
73(b)100 mm. Dia.
74Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work).
75(A)In 10-12 Micron thickness Annodizing film
761) Natural white
77a) 2- track sliding window
78i) Bottom frame
79ii) Top and side frame.
80d)Shutter for all track sliding window.
81i) Bottom & Top member.
82ii)Style side member.
83iii) Interlock member.
84I)Fixed partitions.
85Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)
86i) Top , bottom & side member.
87ii)Intermediate member.
88iii)Glazing clip.
89k)Movable door shutter.
90i) Door frame. (Top & sides).
91ii)Shutter : Top rail.
92Bottom rail.
93Lock rail
94Door vertical.
95Glazing cleap.
96Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-
97(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.
98i ) 2 track sliding window.
99(B)Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections,etc.
100(d)Partly glazed and partly panelled partition or fixed glazing made of extruded and anodisedalloy aluminium sections, fabrications after cutting to proper shape and size, drilling and aliningfitted etc.
101I)For partitions using section of size:
102a) 63.50 mm x 38.10 mm
103Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
104Supplying maruti lock (100mm)
105Supplying EPDM gusket of approve make and brandas per direction of Engineer in charge.
106i)For sliding windows
107b) " U" shaped EPDM gasket for frames.
108iii)weather gaskett / wool pile for door vertical.
109Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987.
110ii) 4mm thick coloured / tinted / smoke glass.
111Wall panelling / partition with Melamine faced 3 layered flat pressed wood particle board of approved make and brand as per direction of Engineer - in - Charge of requisite grade bonded with phenol formaldehyde synthetic resin conforming to IS: 848 - 1974 (excluding the cost of supporting frame work and teak wood battens / lipping)
112(B) Prelaminated particle board onforming to IS: 3087 - 1985 and IS 12823 -
113(ii) Both side decorative laminate
114a) Exterior grade
1159mm thick
116Supplying 4 lever mortice lock or anyapproved make and brand as per direction of the EIC
117ii) 100 mm.
118[B] Supplying 125 mm dia acrylic handle for aluminium door as per approved make and brand :-
119a] Natural colour :-
120Supplying heavy duty hydraulic double action floor spring along with toppin/set of pivots conforming to IS: 6315 or any approved make as perdirection of Engineer in charge.
121Dismantling all types of masonry excepting cement concrete plain or reinforced,tacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
122a) In ground floor including roof.
123Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
124(a) upto 150 mm. thick
125a) In ground floor including roof.
126Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
127(a) In ground floor including roof.
128Cutting chase upto 125 x 150 mm. and subsequent mending of damages..
129(a) in brick wall [Cement-3.6 Kg/Mtr]
130Cutting holes and subsequent mending good damages.
131(c) Diameter exceeding 300 mm. but not exceeding 450 mm.
132(ii) In concrete work (plain or R.C.) [Cement-7.5 Kg/Mtr]
133Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
134(A) For Exposed Work
135(a)(i)15 mm dia. light quality
136Supply & labour for F/F of Highy Density Polythine Pipe conforming to IS 4984 - 1985
137A) 6 KG / Sq.Cm.(Dia) (Working Pressure)
138Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.
139(ii)550 mm X 400 mm size
140Supplying, fitting and fixingbib cock or stop cock.
141(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).