Electric Works Division has published A / A / R To E.I In I.T.I Work Shop And S.I.T.C Of 1 Nos 16 Mtr Long High Mast Light In The Campus Of I.T.I College At Patamda, Purbi Sinbhbum. A / A / R To E.I In I.T.I Work Shop And S.I.T.C Of 1 Nos 16 Mtr Long High Mast Light In The Campus Of. Submission Date for this Tender is 25-01-2022. Street Lighting Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Par-"A"A/A/R to E.I. in I.T.I workshop at I.T.I Patmada. |
2 | Wiring for light point/fan point/exhaust fan point/call bell point, with1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, piano type switch,phenolic laminated sheet with suitable size PVC/MS box etc as required |
3 | Group C |
4 | Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVCinsulated copper conductor single core cable for loop earthing etc as required. |
5 | Wiring forcircuit/ submain wiring along with earh wire with the following sizes ofFR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required |
6 | a)2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire (for highway light wiring) |
7 | b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (for light circuit ) |
8 | c) 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire (for light submain) |
9 | d) 2 x 10 sq.mm + 1 x 6 sq.mm earth wire (for power submain) |
10 | e) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (for computer board wiring) |
11 | Supplying and fixing suitable size GI/PVC box of75 mm x 75 mm x 50 mm deepon surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch. connection, painting etc. as required (For light plugs to be used in non residential buildings ) |
12 | Supplying and fixing suitable size GI/PVC box of121 mm x 173mm x 48mm/(6" x 8") (nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch. connection, painting etc. as required |
13 | S/F a compact unit made of 8"x10"PVC/G.I box with phenolic laminated sheet cover in front fixed with 2 nos of 5 amps piano type switch and 2 nos. socket and 1 nos of 15 amp switch and socket well connected with suitable wire earthing etc as reqd name as computer board ((administrative Building) |
14 | a)) 8"x10" PVC box with sheet cover 1 nos @@2 195.00 |
15 | B) 5 amp swithc - 2 nos @@2 29.00 = 58.00 |
16 | C) 5 amp socket - 2 nos @ 39.00 = 78.00 |
17 | d) 15/16 amps, 6 pin S.S Combined - 1 nos @ 99.00 |
18 | Total = 448.00 |
19 | Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box/ wooen block including connection etc. as required . |
20 | Supplying and fixing Batten / Angle holder including connection etc as required . |
21 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc. as required. |
22 | a) 5/6 amps, one way switch (controling for highway ight) |
23 | b) Electronic step fan regulator, deluxe |
24 | Supplying and fixing of following sizes ofPVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
25 | a) 210 mm x 206mm x 48mm deep/ (10" x 12") |
26 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper cable direct on the wall with PVC clips etc. as required. |
27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
28 | a) 2 way, Single door (for Campus light) |
29 | b) 6 way, Single door |
30 | c) 8 way, Single door |
31 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. |
32 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
33 | a) 40 amps |
34 | b) 63 amps |
35 | Supplying and fixing 20 amps, 415 volts,TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, TPN, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
36 | S.I.T.C of floowing rating surface mounted LED tube light fittingsuitable for 230V 50Hz, single phase supply etc. complete as required. |
37 | 20/22W LED Tube light |
38 | 9/10Watt LED Bulb |
39 | SupplyInstallation, testing and commissioning of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required. |
40 | 1200mm (48") Ceiling Fan |
41 | 12"" (300mm) metal exaust fan . Make Polar, Havells, Bajaj,Polycab or equivelant. |
42 | S.I.T.C of floowing rating LED Flood lighting luminariewith pressure die cast housing and toughenedglass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-5 and shall be complete with all neccssary accessories as required |
43 | 90/100W LED Flood light |
44 | 80/90W suspended type industrial COB LED highbay light withaluminium die cast heat sink. |
45 | Supplying and laying of XLPE insulated PVC sheathed aluminium armouredcable working voltage upto 1100 volts as per IS:7098(PartI) of following sizes ((((Make Havells/Polycab/finolex/capital or equivalent))) |
46 | a) 2 core 6 sq, mm. (For campus light) |
47 | b) 10 sq. mm, 4 core From sub panel to maching) |
48 | c) 50 sq. mm, 3.5 core ((From workshop panel to different workshop sub manel |
49 | d) 150 sq. mm, 3.5 core ((From transformer to workshop main panel)) |
50 | e) 70 sq. mm, 3.5 core ( From generator room to workshop main panel) |
51 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mmdirect in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
52 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 95 sq mm but not exceeding 185 sq mmdirect in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
53 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
54 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm to 95 sq mm (clamped with 20mmx3mm GI Tape) |
55 | Cable Junction Box Make :- sintex/Heansel |
56 | 6sq mm aluminium lugs |
57 | 10 sq mm aluminium lugs |
58 | 25 sq mm aluminium lugs |
59 | 35 sq mm aluminium lugs |
60 | 50 sq mm, aluminium lugs |
61 | 70 sq mm alumimioum lugs |
62 | 120 sq mm aluminium lugs |
63 | 150 sq mm aluminium lugs |
64 | 50 mm dia, medium class G.I pipe laying for cable in road cressing |
65 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
66 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldingetc. as required. |
67 | making 250 mm. clear wide brick drain with cement morter 1:6 with 250 mm, depth 125 mm apron with one brick flat soling plaster CM 1:3 with punning sand filling but excluding earth wirk in brick drain all complete etc as reqd |
68 | Earth work PCC cutting Dismantaling of cement concrete grae of 15 m & 20 by menual meams with all lift and load. |
69 | Supplying and fixing 1.5 mtr long G.I angle fixing for TPN MCB enclosure, industrial type socket, angle grouting on earth making good same all complete with nut, bolt & waser etc as reqd |
70 | Fabrication and installation fo cubical panel with following accessories made of 16 SWG M.S sheet painted wigh one coat steel primer and two coat power spray painting with approved shade making PCC plingh and foundation including fitting/ fixing/connection & transportation up to work site, labour charge ertc all complete. (for Electrician workshop welder, fitter & deisel mechinic workshop machinist room) |
71 | 200 amp 4 pole MCCB fixed thermal setting = 1 nos 63 amps TP&N MCB = 15 nos |
72 | Digital volt mtr (0-500AMP) - 3 Phase class 0.5 = 1 nos. |
73 | Digital AMP Mtr (0-500 AMP) 3 Phase Class 0.5 = 1 nos |
74 | LED indecator lam R/Y/B/G = 3 nos |
75 | 25 mm x 5mm x copper strip (1.15 Kg/Mtr) = 4 Kg |
76 | 16 sq mm PVC in sulated ISI marked single core copper conductor cable = 64 mtr |
77 | 16 sq mm copper lugs =120 Pc |
78 | Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S Sheet painted with one coar steel primer and two coar power spray painting with approved shade making PCC plinth and foundation including fitting / fixing/ connection & transportation up to work site labour charge etc all complete (for small different workshop) |
79 | 160 amp MCCB 35 KA Fixed thermal setting = 1 nos |
80 | LED indecator lam R/Y/B/G = 3 nos |
81 | 25 mm x 5mm x copper strip (1.15 Kg/Mtr) = 4 Kg |
82 | 16 Sq mm copper lugs =8 Pc |
83 | Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S Sheet painted with one coar steel primer and two coar power spray painting with approved shade making PCC plinth and foundation including fitting / fixing/ connection & transportation up to work site labour charge etc all complete (for workshop main panel) |
84 | 63 amp MCCB 10 KA Fixed thermal setting = 1 nos |
85 | 150/160 amp, MCCB 35 KA Fixed thermal setting = 6 nos |
86 | 200 amps, MCCB 35 KA fixed hermal setting = 6 nos |
87 | 400 amps, MCCB 35 KA, fixed thermal setting = 1 nos |
88 | 400 amps, 4 pole panel mounted changeover = 1 nos |
89 | Digital volt mtr (0-500AMP) - 3 Phase class 0.5 = 1 nos. |
90 | Digital AMP Mtr (0-500 AMP) 3 Phase Class 0.5 = 1 nos |
91 | LED indecator lam R/Y/B/G = 3 nos |
92 | C.T. Coil of C.T Ration 300/5 = 3 nos |
93 | 25 mm x 5mm x copper strip (1.15 Kg/Mtr) = 85 Kg |
94 | Part "B" S.I.T.C of 1 no 16 mtr long high mast light in the campus of I.T.I college at patamda. Jamshedpur, |
95 | Supply of 16mtr. High mast in two section Construction S355 grade as per BS-EN 10 025 Top Dia 150mm, bottom dia 360mm, plate thickness 3mm, 20side polygon, galvanisation as per BS EN ISO 1461, base plate dia 520mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/s with 6 nos foundation bolts of PCD 445mm TS 600/ 24mm dia/850 mm long. Luminaries carriage : Material for 40 NB ERW Class B – M.S. Pipe, dia of carriage ring 450mm (ID) with 8/12 arm, welded, 2 sections having carrying capacity upto 8/12 luminaries.Trailing Cable : 5 core 2.5sq.mm. PVC flexible copper conductor Winch/Power Tool : Double drum, SWL 350 kg with1HP 6 pole single speed integral motor Rope : Grade AISI 304, 7/19 construction, dia 5mm, BLC 1450 x 2 having 2 nos of continues rope. Aviation obstruction light : twin dome aviation obstruction lights LED type as required. Feeder Pillar : control panel housing 63A TPN MCB incomer, single dial timer, 45A contactor circuit for the automatic control of luminaries power tool control with 2 no 9A contactors and raise lower push button, incoming 35sq.mm. and outgoing 16 & 2.5 sq.mm. terminals. |
96 | For 16 mtr. High mast : ITC of the high mast and light fixture with the help of suitable tools and plants, wiring of luminaries with all wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T/ mtrs sq. for 16 M High mast. |
97 | S.I.T.C of 200w LED flood lighting luminarie with pressure die cast houseing and toughened glass cover IP 66 Protecrtion and shall be complete with alll necessary accessories as reqd. |
98 | Supplying and laying of XLPE insulated PVC sheathed aluminium armouredcable working voltage upto 1100 volts as per IS:7098(PartI) of following sizes ((((Make Havells/Polycab/finolex/capital or equivalent))) |
99 | a 4 core 16 sq mm From administrative building mian panel to highmast light |
100 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. |
101 | 16sq.mm. aluminium lugs |
102 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
103 | a- 4 way, Double door |
104 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
105 | a- 63 amps |
106 | Earthing with G.I. earth pipe 4.5 mtr long . 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. |
107 | Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldingetc. as required. |
108 | GST @ 12% |
109 | Labour Cess @ 1% |