Rural Development Department has published Special Repair To Phc Building At Angansinji Tq.Dhamangaon Railway Special Repair To Phc Building At Angansinji Tq.Dhamangaon Railway. Submission Date for this Tender is 28-01-2022. Building Work Tenders in Amravati Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Jan-2022 | DATE EXTEND SECOND CALL | Date | 25-01-2022 |
2 | 26-Jan-2022 | DATE EXTEND | Date | 28-01-2022 |
Sl. No. | Item Description |
1 | Dismantlingbrickmasonryinlimeorcementmortarandstackingthematerilsasdirected with all leads, lifts etc. |
2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
3 | Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
4 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. |
5 | Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. |
6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade) |
7 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
8 | ProvidingandlayingCastinsitu / ReadyMixcementconcreteM-20oftrap/granite / quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
9 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite / quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
10 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
11 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting,rougheningthemifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered bygunnybag,plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
12 | Providing and laying cement concrete flooring 40mm thick with M20 cement concrete laid to proper level and slope in alternate bays, including compaction, filling joints, marking lines to give appearance oftilesof30cm x30cm or othersize laiddiagonally/square etc.finishing smooth (with extra cement) in any colour as directed and Curing etc. complete. With Crushed sand VSI Grade |
13 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ Quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate (Crushed sand VSI Grade) |
14 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. |
15 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc.complete. |
16 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
17 | Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) |
18 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
19 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placedat every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. |
20 | Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/candfixing inwallwith6Nosofholdfastof12mm diabars500mm longincluding primer and oil painting etc, complete) frame size 60 mm x 100 mm . |
21 | Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coatofmetelprimerof approvedmake andmanufacture. M.Sframe shallbe coveredwith heat mouled PVC "C" channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ; and5 mm thick ,95mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the " c " channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3nos M.S.powdercoatedbuthingesofsize100mmx25MMx2mmusing32mmlongsteel screwsdrilledsuitabletopassthroughboththewallsoftheM.Stube.Otherhardwares |
22 | Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window framebottomtrack section 92 x 31.75 x 1.30 mmat weight1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeofbearingbottom40x18x1.25mmat weight 0.417Kilogram/Running metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight o.417Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassandaluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With colour Anodising without box |
23 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. |
24 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc.complete. |
25 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,toconcrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
26 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. |
27 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. |
28 | Solid Core Flush door Single leaf Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineerbeforeuse) Commercial Hard Wood shutter |
29 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfacesintwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete. |
30 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete. |
31 | Finishing the terrace slab integrally mixed with water proofing compound in C.M. 1:3 with 12mm thick layer including curing, finishing using waterproofing compound as approved by Engineer-in-charge at the rate of 1kg perbag of cement etc. complete (Note: Item not to be usedas waterfroofing treatment over terreces) |
32 | Providing and laying cement concrete flooring 40 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction, filling joints, marking lines to givetheappearanceoftilesof30cmx30cmorothersizelaiddiagonally/squareetc finishing smooth (with extra cement) in any colour as directed and curing etc.complete.with Crushed sand VSI Grade |
33 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing etc. complete. |
34 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingetc. complete |
35 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS15622-2006 (Group-BIIA) for antiskid flooring inrequired position laid on a bed of 1:4 cement mortar includingcementfloat,fillingjointwith cement slurry cleaning curing etc. complete. |
36 | Providingandlayingceramictilesof havingsize30cm.x30cm.andconfirmingto corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
37 | Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One side polish |
38 | Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, moulding edges, cleaning complete. a) Marble other than white makra |
39 | Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend,15mm.thick10litrePVCflushingcisternwithallnecessarypipeconnectionetc. complete. |
40 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. |
41 | Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete. |
42 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
43 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
44 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
45 | Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
46 | Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete |
47 | Providing,layingandfixingP.V.C.pipeof75mmdia.withfittingssuchasbends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
48 | Providing, laying andfixing P.V.C. pipe of 110mm. dia. withfittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed etc. complete. |
49 | Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting andfixingofaccessoriessuchasinlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters |
50 | Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8C.Cfoundation,1:2:4C.C.channels/halfroundglazedstonewarepipechannel,salt glazedstone-wareinterceptingtrapwithroddingpipesetin1:4:8cementconcreteblock, brickmasonryplasteringinsideandOutside,fixedincementconcretewithR.C.C.Cover medium duty 140 Kilogram. etc complete |
51 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gussetplatesetc.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting,erectingfixinginposition,Makingriveted/bolted/welded connectionandone coat of anticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
52 | Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) |
53 | Providingandfixingblackkadappastoneasshelves25mm.thickmachinepolished, extendingthepolishupto20cmwidthonlowerside,roundingcorners,layinginposition jointing with bedding cement mortar 1:4 proportion curing etc etc. complete. |
54 | Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. |
55 | Providing and fixing board displaying information, such as "Name of work, Tender cost, Name of Contractor, Work completion and liability period etc", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge |
56 | Basic Test of Steel Tensile Strength Elongation , Yield Stress,Weight Per Meter , Proof Stress |
57 | 80 mm /40 mm metal Hb/crusher Water Absorption |
58 | Impact value |
59 | Gradation /Sieve Analysis. |
60 | Flakiness Index & Elongation Index |
61 | TEST FOR CONCRETE Compressive Strength of C.C. Cube (set of 3 cubes) 1 Test ONE TEST FOR R.C.C. Footing |
62 | ONE TEST FOR R.C.C. COLUMN |
63 | ONE TEST FOR R.C.C. BEAM |
64 | ONE TEST FOR R.C.C. SLAB |
65 | TEST FOR CEMENT Standard Consistancy, Fineness, Specific ,Gravity, Setting Time ( Initial & Final ) |
66 | BASIC TEST OF BRICKS Water Absorption (set of 5 Bricks) Compressive strength |
67 | TEST FOR SAND Finess Modulus (Sieve Analysis) Silt & Claya content |
68 | Test For Tiles |
69 | tiles |
70 | Royalti Charges Murrum |
71 | Royalti Charges H.B.metal |
72 | Royalti Charges Sand |