Aurangabad Municipal Corporation has published Maintenance And Repairing Water Supply Pipe Line In Zone No. 5 Ward No. 62, 63, 64 And 40. Submission Date for this Tender is 25-01-2022. Water Pipe Line Tenders in aurangabad Maharashtra. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc comp. Lift 0 to 1.50 MMJP/DSR/2019-20/Page no.33 I.No.1 |
2 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. roadincluding removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc comp. Lift 0 to 1.50 MMJP/DSR/2019-2020/ Page No.33 I.No.3 |
3 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road by all means including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc comp. Lift 0 to 1.50 MMJP/DSR/2019-2020/ Page No.33 I.No.5 |
4 | Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc comp. Lift 0 to 1.50 MMJP/DSR/2019-2020/ Page No.34 I.No.7 |
5 | Excavation for foundation /pipe trenches in slush muddy / marshy / slushy / soil including use of poclain labour for dewatering during execution including removing the excavtion material upto a distance of 50 meters and lifts as below, stacking and spreading directed preparing the bed by cleancing the mud labour item but shuttering shall bepaid separately. etc. cmplete. |
6 | Dewatering the excavated trenches and pools of water in the pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.MJP/DSR/2019-2020/Page no.35 I.no.14 |
7 | Providing and Supplying Asbestos Cement Pressure Pipes manufactured and tested as per ISO-160 standards of following class and diameter in standard lengths including cost of all taxes (Central and local), insurance,railway freight, inspection charges,unloading from railway wagon, loading into truck, transporting to departmental store/site, unloading, stacking etc. completeMJP/DSR/2012-2013/Page no.57. I.no. 1 |
8 | A) Class 15 ( Test Pressure 1.5 Mpa) |
9 | 80mm |
10 | 100mm |
11 | 150mm |
12 | 200mm |
13 | 250mm |
14 | 300mm |
15 | Lowering, laying and jointingwith CID joints, A.C. pressure pipes and CI or MS specials of following class and diameters including conveyance from stores to site of works, cost of labour and material, giving satisfactory hydraulic testing, etc. as per ISI code, etc. complete but excluding cost of C.I.D. joints, nut bolts, rubber rings. MJP/DSR/2012-2013/P.No.59I.no. 4 (A) |
16 | A) Class 15 ( Test Pressure 1.5 Mpa) |
17 | 80mm |
18 | 100mm |
19 | 150mm |
20 | 200mm |
21 | 250mm |
22 | 300mm |
23 | ProvidingD.I.Pipes ( push on joints pressure pipes of DIof following class and diameters confirming to the IS specification inclusive cost of jointing materials (rubber gasket of EPDM quality)excludingGST levied by GoI & GoM in all respect includingThird Party Inspection charges of TPI agency approved by MJP including transit insurance, Railway freight, unloading from railway wagon, loading into truck, transportation to departmental store/site of work, unloading, stacking etc. complete as directed by engineer incharge. (IS-8329:2000 for Pipes & IS-158:1969 & IS-12820:1989 or latest edition/revision with amendments for rubber gasket.) DI K-7 grade MJP/DSR/2019-2020/Page no.59 I.No.3 |
24 | 100 mm |
25 | 150 mm |
26 | 200 mm |
27 | Lowering, laying and jointing with SBR rubber gaskets C.I.& D.I. pipes of various classes with CI / MS specials of following diameters in proper position, grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, excluding cost of jointing materials and rubber rings, including labour, etc complete. Note: Only SBR rubber gaskets to be used as per IS- 5382 / 12820MJP/DSR/2019-2020/Page no.58 I.No.2 (a) |
28 | 100 mm |
29 | 150 mm |
30 | 200 mm |
31 | Cutting and champhering of pipes of following diameters including cost of all materials and labour involved, etc. complete as directed by Engineer-in-charge. (for all class of pipes)MJP/DSR/2019-2020/Page no.136 I.No.20 |
32 | 100 mm |
33 | 150 mm |
34 | 200 mm |
35 | 250 mm |
36 | 300 mm |
37 | 350 mm |
38 | Providing and supplying C.I.detachable joints suitable for A.C. pressure pipes manufactured as per IS- 1538 / 1993 standards of following class and dimeter including cost ofinsurance, railway freight, inspection charges, unloading from railway wagon, loading into truck, transporting to departmental store, unloading, stacking and cost of rubber rings, nut bolts, excluding GST levied by GOI & GOM in all respect etc. complete. MJP/DSR/2019-2020/Page no. 64I.no.13 |
39 | Class 10 /15 |
40 | 80 mm |
41 | 100 mm |
42 | 150 mm |
43 | 200 mm |
44 | 250 mm |
45 | 300 mm |
46 | Providing and supplyingI.S.I. mark rubber gasket suitable for C.I. or D.I. pipe of all class for tyton joints including inspection charges, transportation upto departmental stores excluding GST levied by GOI & GOM in all respect etc. complete. MJP/DSR/2019-2020/Page no.137 I.No.21 (A) |
47 | 80 mm |
48 | 100 mm |
49 | 150 mm |
50 | 200mm |
51 | 250 mm |
52 | 300 mm |
53 | 350 mm |
54 | Supply of C.I. Mechanical Compression Collar Coupling suitable for C.I Spun Pipes ( as per IS-1536 /2001) and complete with sealing rubber gasket of SBR, C.I. follower Glands and M.S. nut bolts. The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS: 1538 / 1993MJP/DSR/2018-2019/Page no.140 I.No.2 |
55 | 150 mm |
56 | 200 mm |
57 | 250 mm |
58 | 300 mm |
59 | Checking & Repairing Private Water connection and reconnecting the same etc complete |
60 | Deisconnection of unauthorised private water connection etc. complete. |
61 | Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in-charge for following diameters of existing pipeline, irrespective of diameter of branch line. ( The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores) MJP/DSR/2019-2020/Page no.47 I.No.10 |
62 | 100 mm |
63 | 150 mm |
64 | 200 mm |
65 | 250 mm |
66 | 300 mm |
67 | Removing existing CIDF sluice valve including breking joints etc. complete. |
68 | 100 mm |
69 | 150 mm |
70 | 200 mm |
71 | 250 mm |
72 | Providing double flanged Sluice Valves confirming to IS- 2906 / 14846 including worm gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.PN-1.0 ( without bypass arrangement)MJP/DSR/2019-2020/Page no.127 I.No.2 (A) |
73 | 100 mm |
74 | 150 mm |
75 | 200 mm |
76 | Lowering laying and jointing in position following C.I. D/F Reflux Valves, Butterfly Valves and Sluice Valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc complete.Sluice Valves MJP/DSR/2019-2020/Page no.130 I.No.4 |
77 | 100 mm |
78 | 150 mm |
79 | 200 mm |
80 | Removing existing cross connection and remaking the same etc complete (70% Rate of making cross connection.) MJP/DSR/2019-2020/Page no.47. I.No.10 |
81 | 80 mm |
82 | 100 mm |
83 | 150 mm |
84 | 200 mm |
85 | 250 mm |
86 | 300 mm |
87 | Removing and refixing the half body of Sluice Valvesincluding excavation, refilling, cost of rubber packing, nut bolts, with gate, gland rope, repair by welding etc complete (70 % Rate of laying Sluice Valves ) MJP/DSR/2019-2020/ Page no.130 I.No.4 |
88 | 80 mm |
89 | 100 mm |
90 | 150 mm |
91 | 200 mm |
92 | 250 mm |
93 | 300 mm |
94 | 350 mm |
95 | 400 mm |
96 | 450 mm |
97 | 500 mm |
98 | Providing and supplying S.S. spindle rod as per standard specifications and suitable for Sluice Valves etc complete. (As Per Market rate ) |
99 | 80 mm |
100 | 100 mm |
101 | 150 mm |
102 | 200 mm |
103 | 250 mm |
104 | 300 mm |
105 | 350 mm |
106 | 400 mm |
107 | 450 mm |
108 | 500 mm |
109 | Providing and supplying Gun metal check nut of following diameter of Sluice Valves as per standard specifications, etc. complete |
110 | 80 mm |
111 | 100 mm |
112 | 150 mm |
113 | 200 mm |
114 | 250 mm |
115 | 300 mm |
116 | 350 mm |
117 | 400 mm |
118 | Repair the gate by welding to make it in original position etc. complete. |
119 | 100 mm |
120 | 150 mm |
121 | 200 mm |
122 | 250 mm |
123 | 300 mm |
124 | 400 mm |
125 | Providing and fixing M.S extension rod as per site requirement to fix above existing sluice valve etc. complete. |
126 | 100 mm |
127 | 150 mm |
128 | 200 mm |
129 | Providing and Supplying M.S. clamp for pipes of following diameters etc comp.(As Per Market rate ) |
130 | 80 mm |
131 | 100 mm |
132 | 150 mm |
133 | 200 mm |
134 | 250 mm |
135 | 300 mm |
136 | Providing and supplying ISI standard CI flanged / S & S specials excludingGST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truk, transport to departmental stores,unloading, stacking, etc. complete.C) Plain ended/plain ended branch flanged specials- i) 80 mm dia to 300 mm diaMJP/DSR/2019-2020/ Page no.60, I.No.6 (C) |
137 | Providing and supplying ISI standard MS specials of required thickness with 3 coats of approved make epoxy paint ( Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excludingGST levied by GOI & GOM in all respect includinginspection charges, transportation to stores and stacking, etc. complete.e) Plain ended specials or plain ended branch flanged specials of all diameters. MJP/DSR/2019-2020/Page no.61 I.no.7(e) |
138 | Providing & laying in situ cement concrete M-15/1:2:4 of trap/granite/ quartzite/ gnessmetal for foundation and bedding including dewatering, compacting and curing etc. complete. PWD/DSR/2015-16/P.NO 287 I no 29 |
139 | Providing and making lead caulked joint with molten lead to Cast Iron pipes and / or specials of all classes and fitting of following dia including cost of lead and all jointing material, labour, hydraulic testing etc. complete.MJP/DSR/2019-2020/Page no 60 I.no.4 |
140 | 150 mm |
141 | 250 mm |
142 | 300 mm |
143 | Providing and fixing water level indicator upt to 5 M heightincluding M.S. enamelled gauge plate 399 mm wide and 3 mm thick, copper float providing and fixing required accessories such as pointer, pulleys, mylon thread including cost of all material, abour etc. complete. |
144 | Removing and refixing C.I. gland plate including ncecssary excavtion etc. complete. |
145 | 100 mm |
146 | 150 mm |
147 | 200 mm |
148 | 250 mm |
149 | 300 mm |
150 | 350 mm |
151 | 400 mm |
152 | 450 mm |
153 | 500 mm |
154 | Supplying and fabricating valve key & hollow pipe matching to exiting valve spindle rod etc. complete. |
155 | a) 80mm dia to 200mm dia sluice valve |
156 | b) 250mm dia to 500mm dia sluice valve |
157 | Repairing of vlave key matching to existing valve spindle rod inclduing welding and finishingetc complete |
158 | a) 80mm dia to 200mm dia sluice valve |
159 | b) 250mm dia to 500mm dia sluice valve |
160 | Removing and refixing of level indicator with required painting wire rope and pully fixing placing in proper etc. complete. |
161 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc.complete.MJP/DSR/2019-2020/Page no.36 I.No.15 |