}

Construction And 05 Years Maintenance Of Roads Under New Technology Fdr, Full Depth Reclamation / In-Situ Stabilization With Cement And Additive Of Group No-Up-Fdr08 ( Package No- Up06158, Up06142, Up06145 ) In District-Azamgarh. Construction And 05 , azamgarh-Uttar Pradesh

Uttar Pradesh Rural Road Development Agency-UPRRDA has published Construction And 05 Years Maintenance Of Roads Under New Technology Fdr, Full Depth Reclamation / In-Situ Stabilization With Cement And Additive Of Group No-Up-Fdr08 ( Package No- Up06158, Up06142, Up06145 ) In District-Azamgarh. Construction And 05 . Submission Date for this Tender is 18-02-2022. Road Repair Tenders in azamgarh Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30691658
Corrigendum : Construction And 05 Years Maintenance Of Roads Under New Technology Fdr, Full Depth Reclamation / In-Situ Stabilization With Cement And Additive Of Group No-Up-Fdr08 ( Package No- Up06158, Up06142, Up06145 ) In District-Azamgarh. Construction And 05
Open Tender
Indian
Uttar Pradesh
azamgarh
18-02-2022

Tender Details

Construction And 05 Years Maintenance Of Roads Under New Technology Fdr, Full Depth Reclamation / In-Situ Stabilization With Cement And Additive Of Group No-Up-Fdr08 ( Package No- Up06158, Up06142, Up06145 ) In District-Azamgarh. Construction And 05 Years Maintenance Of Roads Under New Technology Fdr, Full Depth Reclamation / In-Situ Stabilization With Cement And Additive Of Group No-Up-Fdr08 ( Package No- Up06158, Up06142, Up06145 ) In District-Azamgarh.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jan-2022 UPFDR08 SBD Corrected as per Pre-Bid Meeting Details Terms and Conditions 18-02-2022

Key Value

Document Fees
INR 5000 /-
EMD
INR 5519000.0 /-
Tender Value
INR 27.59 Crore /-

BOQ Items

Name of Work:- Construction and 5-Year Maintenance of Road Under Full Depth Reclamation/ In-Situ Stabilization with Cement and Additive of Pkg No UPFDR-08 1- T01-Centerwa Bazar to Durbasa (Length 11.500 Km) Distt: - AzamgrahPkg No UP06142 2- MRL07-L.B. ROAD TO NANDAW (Length 08.50 Km) Distt: Azamgarh Pkg No UP 06145 3- T02-Marteenganj to Jaigaha Marg (Length-07.00 Km) Distt AzamgarhPkg No UP 06158
Sl. No. Item Description
1(1)T01-Centerwa Bazar to Durbasa (Length 11.500 Km) Distt: - AzamgrahPkg No UP06142:- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. [RA-1]
2Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 [RA-4]
3Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 305[RA-3]
4Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause[RA- 15]
5Construction of Sub-grade with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead up to 1000m as per Technical Specification Clause 303.1 [RA-5]
6Dismantle of Flexible and Granular pavements and spreading in the proposed width using grader in required camber and compacting to required degree of compaction separately as per technical Specification Clause 202 [RA-29]
7Stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: Providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with IRC-SP-72-2015 , IRC-37-2012 & 2018 and IRC SP 89 (part II) 2018. Cementitious additive @ rate of minimum 5 - 7% and CCS/CS additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. The additive spreader shall have variable working width sufficient to cover whole pavement lane. The in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. The resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per IRC 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. The entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. The tandem roller be followed by Pneumatic Tyre Roller. The minimum unconfined compressive strength (UCS) of stabilized sub base/ base should be4.5 to 7 MPa after 7 / 28 days of curing as per IRC-SP-72-2015 , IRC-37-2012 & 2018 . Also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The gradation mixes and materials should be as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The train of equipments to be used are binder spreader- water Tanker- Additive Truck- Recycler- Padfoot Roller (20 Tonne) + Single Drum Compactor- Grader- Tandom Roller- Pneumatic Tyre Roller (20 Tonne)RA-6]
8Providing and laying Primer coat with Bitumen(SS-1) on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70-1.0 kg/Sqm using mechanical means as per technical Specification Clause-502. [RA-9]
9Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion Distributor at the 0.20-0.25 kg per sqm on the prepared Bituminous/Granular Surface cleaned with hydraulic broom as per Technical Specification -503 [RA-10]
10SAMI/Bitumen impregnated Geotextile layer Providing and laying Stress Absorbing Membrane Interlayer (SAMI)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of clause 703-3, laid over a tack coat of paving grade Bitumen 80-100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement Surface. [As per the Letter no. 2795/T-252/FDR/UPRRDA/2021 dated 23-02-2021] (RA-12)
11Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6per centof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects [RA-11]
12Construction ofPanel concrete plain Cement concrete pavement, Thickness as per design, over a prepared subbasewith 43 grade cement or any other type as per Clause 1501.2.2 M 30 (Grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate no exceeding 25mm, mixed in a concrete mixer of not less that 0.2 cum capacity and appropriate weigh batcher uusing approved mix design , laid in approved fixed side formwork ( Steel Channel, Laying and fixing of 125 micron thiock polythene film , wedges, steel plates including levelling th formwork as per Drawing ), Spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and fininshedin continous operation including provision of contraction and expansion, construction joints , applying debonding strips, primer, sealant , dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days. curing compound ( Where specified ) and water finishing to lines and grade as per drawing and Technical specification Clause 1501. PCc Grade M-30 Each Panesl ( 0.50 X0.50 ) thickness 125mm
13Reinforced cement concrete M15 grade Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 Ordinary K.M. stone (precast) [RA-24]
14Reinforced cement concrete M15 grade 5th Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 [RA-24]
15Reinforced cement concrete M15 grade Hectometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing &Technical specification Clause 1703 (iii) 200 mt stone (precast) [RA-24]
16Providing and erecting direction and place identification retro-refiectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide 1701.2.3, fixed over aluminium composite panel sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 No.. firmly fixed to the ground by meanes of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.Junction Board [RA-25]
17Providing and fixing ofReference Bench Mark / Temporary Bench Mark having section .0.35X.0.35 M and height 0.30 M above ground level in B/W 1:3 as per drawing and technical specifications
18Providing and fixing of precast RCC Level Pillars in M15 ( 1:2:4 ) Nominal Mix having section 10 X 10 cm and Length 1.5 M which will be reused as Boundry/Guard Stones on curves including painting with specified colours after completion of work) as per drawing and technical specifications
19Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Hazard Markers
20Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Delineators
21Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Warning Signs
22Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Stop Sign (900mm Octagonal)
23Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Chevron Signs
24Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Mandatory Signs 600 mm
25Providing and fixing of typical PMGSY Maintenance informatory Retro Reflective sign board with Logo as per MORD specifications and drawing. The board will be a composite unit consisting of three plates of Aluminium composite material (ACM) 4mm thick face to be fully covered with high intensity prismetic sheeting type-4, material specification as per clause 1701.3.7. The top most plate will be a diamond shape of 600mmX600mm size rivited over welded MS iron angle frame of 25X25X5(mm size) on back on edges. The middle plate will be 1200mmX150mm size rivited over welded MS iron 25mmX25mm size on back on edges. The main lower most plate will be 1500mmX600mm size rivited over welded MS angle iron 25mmX25mmX5mm size. Welding of all two sheets over angle iron frame will be done neetly to plain surface on one side. The angle iron frame of the lower most plate and fiat iron frame of middle plate will be welded to 2 No.. 75mm x 75 mm of 12 SWG sheet tubes posts placed at 1125mm a part center to center duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. The lettering and border etc. of middle and bottom plate, PMGSY Logo on top plate shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing. [RA-20]
26Providing & fixing LogoBoard ofPRADHAN MANTRI GRAM SADAK YOGNAas per standarddesign of National Rural Infrastructure development agency, diamond size (600 X 600 mm)3 mm thick ACM plateand board plate size (1100 X 300 mm) 3 mm thick ACM plate and 2.4 m deep length square hollow section (75 X 75 X 6 mm) size including fitting and painting lettering with retroreflective sheeting class B as per drawing incl. fixing in CC M20 (450 X 450 X 600 mm) as per IRC 67 [RA-18]
27Providing & fixingof typical PMGSY Citizen"s information board consisting of two Aluminium Composite Material (ACM), 4mm thick face to be fully covered with high intensity prismetic sheeting type-4 class A/B material specification as per clause 1701.3.7. ACM sheets shall be of size 900mmX750mm each welded over welded MS flat iron frame of 50mm x 6mm size on back on edges. The flat iron frame of the bottom plate will be welded to 1 no. 75mm x 75mm x 6mm Square tube post. The steel tube post will be embedded in cement concrete M15 grade of 600mm x 600mm x 750mm below ground level. The height of lowermost part of the bottom plate will be 650 mm from normal ground level. The lettering and border etc. of ACM sheets on top & bottom shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing [RA-26]
28Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.[RA-21]
29Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.[RA-27]
30Earthworkinexcavationoffoundationofstructuresas per drawing and technical specifications including setting out,construction of shoring and bracing, removal of stumpsandotherdeleteriousmatter,dressingofsides and backfilling with approved material. (ALL EXCAVATION)
31Plain/reinforcedconcreteinopenfoundationscomplete as per drawing and Technical specifications M10.
32Fillling in foundation trenches using Local Sand as per drawing and technical specification Clause 305.3.9
33Laying Cement Concrete 600mm dia Pipe NP3 (burried conduits) on first class bedding of granular material in single row including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapet
34Plain/reinforcedconcreteinopenfoundationscomplete as per drawing and Technical specifications M15.
35Drain covers M25.
36Supplying and fixing reinforced concrete heavy duty non-pressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Class NP3 of following internal diameter. (vi) 1200 mm dia. Class NP3 1000mm dia.
37Providing and fixing of precast RCC Guard Stone in M20( 1:2:4 ) Nominal Mix having section 0.25x0.25 M and Length 1.0 M fixed in M10 concrete of section 0.50x0.50 m in thickness 0.40 M as per drawing and technical specifications
38Providing and laying rubble for stone pitching (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls.(more than 10 ton)
39Providing and laying rubble for appron (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls. (more than 10 ton)
40HYSD Bar in R.C.C. work
41Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 (1:3)
42Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204
43Plastering with cement mortar (1:4), 15mm thick on brickwork in substructure as per technical specification
44White washing of Culvert walls
45(2)- MRL07-L.B. ROAD TO NANDAW (Length 08.50 Km) Distt: Azamgarh Pkg No UP 06145:- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. [RA-1]
46Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 [RA-4]
47Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause[RA- 15]
48Construction of Sub-grade with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead up to 1000m as per Technical Specification Clause 303.1 [RA-5]
49Dismantle of Flexible and Granular pavements and spreading in the proposed width using grader in required camber and compacting to required degree of compaction separately as per technical Specification Clause 202 [RA-29]
50Stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: Providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with IRC-SP-72-2015 , IRC-37-2012 & 2018 and IRC SP 89 (part II) 2018. Cementitious additive @ rate of minimum 5 - 7% and CCS/CS additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. The additive spreader shall have variable working width sufficient to cover whole pavement lane. The in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. The resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per IRC 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. The entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. The tandem roller be followed by Pneumatic Tyre Roller. The minimum unconfined compressive strength (UCS) of stabilized sub base/ base should be4.5 to 7 MPa after 7 / 28 days of curing as per IRC-SP-72-2015 , IRC-37-2012 & 2018 . Also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The gradation mixes and materials should be as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The train of equipments to be used are binder spreader- water Tanker- Additive Truck- Recycler- Padfoot Roller (20 Tonne) + Single Drum Compactor- Grader- Tandom Roller- Pneumatic Tyre Roller (20 Tonne)RA-6]
51Providing and laying Primer coat with Bitumen(SS-1) on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70-1.0 kg/Sqm using mechanical means as per technical Specification Clause-502. [RA-9]
52Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion Distributor at the 0.20-0.25 kg per sqm on the prepared Bituminous/Granular Surface cleaned with hydraulic broom as per Technical Specification -503 [RA-10]
53SAMI/Bitumen impregnated Geotextile layer Providing and laying Stress Absorbing Membrane Interlayer (SAMI)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of clause 703-3, laid over a tack coat of paving grade Bitumen 80-100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement Surface. [As per the Letter no. 2795/T-252/FDR/UPRRDA/2021 dated 23-02-2021] (RA-12)
54Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6per centof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects [RA-11]
55Construction ofPanel concrete plain Cement concrete pavement, Thickness as per design, over a prepared subbasewith 43 grade cement or any other type as per Clause 1501.2.2 M 30 (Grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate no exceeding 25mm, mixed in a concrete mixer of not less that 0.2 cum capacity and appropriate weigh batcher uusing approved mix design , laid in approved fixed side formwork ( Steel Channel, Laying and fixing of 125 micron thiock polythene film , wedges, steel plates including levelling th formwork as per Drawing ), Spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and fininshedin continous operation including provision of contraction and expansion, construction joints , applying debonding strips, primer, sealant , dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days. curing compound ( Where specified ) and water finishing to lines and grade as per drawing and Technical specification Clause 1501. PCc Grade M-30 Each Panesl ( 0.50 X0.50 ) thickness 125mm
56Reinforced cement concrete M15 grade Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 Ordinary K.M. stone (precast) [RA-24]
57Reinforced cement concrete M15 grade 5th Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 [RA-24]
58Reinforced cement concrete M15 grade Hectometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing &Technical specification Clause 1703 (iii) 200 mt stone (precast) [RA-24]
59Providing and erecting direction and place identification retro-refiectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide 1701.2.3, fixed over aluminium composite panel sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 No.. firmly fixed to the ground by meanes of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.Junction Board [RA-25]
60Providing and fixing ofReference Bench Mark / Temporary Bench Mark having section .0.35X.0.35 M and height 0.30 M above ground level in B/W 1:3 as per drawing and technical specifications
61Providing and fixing of precast RCC Level Pillars in M15 ( 1:2:4 ) Nominal Mix having section 10 X 10 cm and Length 1.5 M which will be reused as Boundry/Guard Stones on curves including painting with specified colours after completion of work) as per drawing and technical specifications
62Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Hazard Markers
63Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Delineators
64Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Warning Signs
65Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Stop Sign (900mm Octagonal)
66Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Chevron Signs
67Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Mandatory Signs 600 mm
68Providing and fixing of typical PMGSY Maintenance informatory Retro Reflective sign board with Logo as per MORD specifications and drawing. The board will be a composite unit consisting of three plates of Aluminium composite material (ACM) 4mm thick face to be fully covered with high intensity prismetic sheeting type-4, material specification as per clause 1701.3.7. The top most plate will be a diamond shape of 600mmX600mm size rivited over welded MS iron angle frame of 25X25X5(mm size) on back on edges. The middle plate will be 1200mmX150mm size rivited over welded MS iron 25mmX25mm size on back on edges. The main lower most plate will be 1500mmX600mm size rivited over welded MS angle iron 25mmX25mmX5mm size. Welding of all two sheets over angle iron frame will be done neetly to plain surface on one side. The angle iron frame of the lower most plate and fiat iron frame of middle plate will be welded to 2 No.. 75mm x 75 mm of 12 SWG sheet tubes posts placed at 1125mm a part center to center duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. The lettering and border etc. of middle and bottom plate, PMGSY Logo on top plate shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing. [RA-20]
69Providing & fixing LogoBoard ofPRADHAN MANTRI GRAM SADAK YOGNAas per standarddesign of National Rural Infrastructure development agency, diamond size (600 X 600 mm)3 mm thick ACM plateand board plate size (1100 X 300 mm) 3 mm thick ACM plate and 2.4 m deep length square hollow section (75 X 75 X 6 mm) size including fitting and painting lettering with retroreflective sheeting class B as per drawing incl. fixing in CC M20 (450 X 450 X 600 mm) as per IRC 67 [RA-18]
70Providing & fixingof typical PMGSY Citizen"s information board consisting of two Aluminium Composite Material (ACM), 4mm thick face to be fully covered with high intensity prismetic sheeting type-4 class A/B material specification as per clause 1701.3.7. ACM sheets shall be of size 900mmX750mm each welded over welded MS flat iron frame of 50mm x 6mm size on back on edges. The flat iron frame of the bottom plate will be welded to 1 no. 75mm x 75mm x 6mm Square tube post. The steel tube post will be embedded in cement concrete M15 grade of 600mm x 600mm x 750mm below ground level. The height of lowermost part of the bottom plate will be 650 mm from normal ground level. The lettering and border etc. of ACM sheets on top & bottom shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing [RA-26]
71Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.[RA-21]
72Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.[RA-27]
73Earthworkinexcavationoffoundationofstructuresas per drawing and technical specifications including setting out,construction of shoring and bracing, removal of stumpsandotherdeleteriousmatter,dressingofsides and backfilling with approved material. (ALL EXCAVATION)
74Plain/reinforcedconcreteinopenfoundationscomplete as per drawing and Technical specifications PCC M15.
75Cement Concrete 1:3:6 (M10) in Base
76Supplying and fixing reinforced concrete heavy duty non-pressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Class NP3 of following internal diameter. (vi) 1200 mm dia. Class NP3 1000mm dia.
77Providing and fixing of precast RCC Guard Stone in M20( 1;2:4 ) Nominal Mix having section 0.25x0.25 M and Length 1.0 M fixed in M10 concrete of section 0.50x0.50 m in thickness 0.40 M as per drawing and technical specifications
78Providing and laying rubble for stone pitching (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls.(more than 10 ton)
79Providing and laying rubble for appron (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls. (more than 10 ton)
80Drain covers M25.
81HYSD Bar in R.C.C. work
82Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 (1:3)
83Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204
84Plastering with cement mortar (1:4), 15mm thick on brickwork in substructure as per technical specification
85White washing of Culvert walls
86(3)-T02-Marteenganj to Jaigaha Marg (Length-07.00 Km) Distt AzamgarhPkg No UP 06158:- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. [RA-1]
87Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 [RA-4]
88Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause[RA- 15]
89Construction of Sub-grade with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead up to 1000m as per Technical Specification Clause 303.1 [RA-5]
90Dismantle of Flexible and Granular pavements and spreading in the proposed width using grader in required camber and compacting to required degree of compaction separately as per technical Specification Clause 202 [RA-29]
91Stabilization of in-situ (existing pavement crust) or soil or otherwise sub base/ base course up to the required depth by cold in-situ recycling using cement and chemical additives / otherwise: Providing pulverizing, spreading, milling and mixing of chemical additives at the appropriate rate as per job mix design in accordance with IRC-SP-72-2015 , IRC-37-2012 & 2018 and IRC SP 89 (part II) 2018. Cementitious additive @ rate of minimum 5 - 7% and CCS/CS additive should be spread on the existing pavement using a mobile truck mounted containerized cement/ additive spreader with micro processor controlled weighing and spreading system. The additive spreader shall have variable working width sufficient to cover whole pavement lane. The in-situ stabilization process shall be carried out by a mobile and self propelled stabilizer / reclaimer of working width of 2.4 m and with minimum engine horse power of 440 kw with a variable working depth up to 50 cm. The resultant stabilized mix then would be profiled to the required grade, level and thickness using motor grader and the mix would be compacted using 20 tonne pad foot roller in combination with smooth wheel roller to achieve desired proctor density as per IRC 37-2012 & 2018 and complete in all respect and curing with water as required including all materials, labour and machinery etc. The entire in-situ process would be carried out in single pass with milling and pulverising of damaged asphalt pavement / soil/ aggregates / soil-aggregate mixture to the desired depth and with simultaneous addition of additives and water with machine integrated spray bars fited on the wheeled self-propelled and vibratory pad foot roller to achieve the desired proctor density in all respects. The tandem roller be followed by Pneumatic Tyre Roller. The minimum unconfined compressive strength (UCS) of stabilized sub base/ base should be4.5 to 7 MPa after 7 / 28 days of curing as per IRC-SP-72-2015 , IRC-37-2012 & 2018 . Also durability aspects (wet-dry cycles) of stabilized sub base should be satisfied as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The gradation mixes and materials should be as per IRC 37-2012 & 2018 and IRC SP 89 (part II) 2018. The train of equipments to be used are binder spreader- water Tanker- Additive Truck- Recycler- Padfoot Roller (20 Tonne) + Single Drum Compactor- Grader- Tandom Roller- Pneumatic Tyre Roller (20 Tonne)RA-6]
92Providing and laying Primer coat with Bitumen(SS-1) on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.70-1.0 kg/Sqm using mechanical means as per technical Specification Clause-502. [RA-9]
93Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion Distributor at the 0.20-0.25 kg per sqm on the prepared Bituminous/Granular Surface cleaned with hydraulic broom as per Technical Specification -503 [RA-10]
94SAMI/Bitumen impregnated Geotextile layer Providing and laying Stress Absorbing Membrane Interlayer (SAMI)/bitumen impregnated geotextile layer after clearing of the road surface geotextile conforming to physical requirements of clause 703-3, laid over a tack coat of paving grade Bitumen 80-100 penetration, laid at the rate of 1.05 kg per sqm over thoroughly cleaned and repaired surface to provide a water resistance membrane and crack retarding layer paving fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, brooming and rolling of surface with pneumatic roller to maximise paving fabric contact with pavement Surface. [As per the Letter no. 2795/T-252/FDR/UPRRDA/2021 dated 23-02-2021] (RA-12)
95Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6per centof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects [RA-11]
96Construction ofPanel concrete plain Cement concrete pavement, Thickness as per design, over a prepared subbasewith 43 grade cement or any other type as per Clause 1501.2.2 M 30 (Grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate no exceeding 25mm, mixed in a concrete mixer of not less that 0.2 cum capacity and appropriate weigh batcher uusing approved mix design , laid in approved fixed side formwork ( Steel Channel, Laying and fixing of 125 micron thiock polythene film , wedges, steel plates including levelling th formwork as per Drawing ), Spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and fininshedin continous operation including provision of contraction and expansion, construction joints , applying debonding strips, primer, sealant , dowel bars, near approaches to bridge/culvert and construction joints, admixture as approved, curing of concrete slabs for 14 days. curing compound ( Where specified ) and water finishing to lines and grade as per drawing and Technical specification Clause 1501. PCc Grade M-30 Each Panesl ( 0.50 X0.50 ) thickness 125mm
97Reinforced cement concrete M15 grade Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 Ordinary K.M. stone (precast) [RA-24]
98Reinforced cement concrete M15 grade 5th Kilometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing and Technical specification Clause 1703 [RA-24]
99Reinforced cement concrete M15 grade Hectometre stone /local stone of standard design as per IRC:8 fixing in position including painting and printing etc. as per drawing &Technical specification Clause 1703 (iii) 200 mt stone (precast) [RA-24]
100Providing and erecting direction and place identification retro-refiectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide 1701.2.3, fixed over aluminium composite panel sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 No.. firmly fixed to the ground by meanes of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701.Junction Board [RA-25]
101Providing and fixing ofReference Bench Mark / Temporary Bench Mark having section .0.35X.0.35 M and height 0.30 M above ground level in B/W 1:3 as per drawing and technical specifications
102Providing and fixing of precast RCC Level Pillars in M15 ( 1:2:4 ) Nominal Mix having section 10 X 10 cm and Length 1.5 M which will be reused as Boundry/Guard Stones on curves including painting with specified colours after completion of work) as per drawing and technical specifications
103Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Hazard Markers
104Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Delineators
105Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Warning Signs
106Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Stop Sign (900mm Octagonal)
107Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Chevron Signs
108Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as perdrawings and Technical Specification Clause 801. [RA-17] Mandatory Signs 600 mm
109Providing and fixing of typical PMGSY Maintenance informatory Retro Reflective sign board with Logo as per MORD specifications and drawing. The board will be a composite unit consisting of three plates of Aluminium composite material (ACM) 4mm thick face to be fully covered with high intensity prismetic sheeting type-4, material specification as per clause 1701.3.7. The top most plate will be a diamond shape of 600mmX600mm size rivited over welded MS iron angle frame of 25X25X5(mm size) on back on edges. The middle plate will be 1200mmX150mm size rivited over welded MS iron 25mmX25mm size on back on edges. The main lower most plate will be 1500mmX600mm size rivited over welded MS angle iron 25mmX25mmX5mm size. Welding of all two sheets over angle iron frame will be done neetly to plain surface on one side. The angle iron frame of the lower most plate and fiat iron frame of middle plate will be welded to 2 No.. 75mm x 75 mm of 12 SWG sheet tubes posts placed at 1125mm a part center to center duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. The lettering and border etc. of middle and bottom plate, PMGSY Logo on top plate shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing. [RA-20]
110Providing & fixing LogoBoard ofPRADHAN MANTRI GRAM SADAK YOGNAas per standarddesign of National Rural Infrastructure development agency, diamond size (600 X 600 mm)3 mm thick ACM plateand board plate size (1100 X 300 mm) 3 mm thick ACM plate and 2.4 m deep length square hollow section (75 X 75 X 6 mm) size including fitting and painting lettering with retroreflective sheeting class B as per drawing incl. fixing in CC M20 (450 X 450 X 600 mm) as per IRC 67 [RA-18]
111Providing & fixingof typical PMGSY Citizen"s information board consisting of two Aluminium Composite Material (ACM), 4mm thick face to be fully covered with high intensity prismetic sheeting type-4 class A/B material specification as per clause 1701.3.7. ACM sheets shall be of size 900mmX750mm each welded over welded MS flat iron frame of 50mm x 6mm size on back on edges. The flat iron frame of the bottom plate will be welded to 1 no. 75mm x 75mm x 6mm Square tube post. The steel tube post will be embedded in cement concrete M15 grade of 600mm x 600mm x 750mm below ground level. The height of lowermost part of the bottom plate will be 650 mm from normal ground level. The lettering and border etc. of ACM sheets on top & bottom shall be as per clause 1701.4.6 messages/borders. All the sections of frame and posts will be painted with primer and two coats of epoxy paint. The steel tube below ground level will be painted with three coats of epoxy paints. The design, painting and lettering shall be done as per approved drawing [RA-26]
112Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes.[RA-21]
113Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.[RA-27]
114Earthworkinexcavationoffoundationofstructuresas per drawing and technical specifications including setting out,construction of shoring and bracing, removal of stumpsandotherdeleteriousmatter,dressingofsides and backfilling with approved material. (ALL EXCAVATION)
115Plain/reinforcedconcreteinopenfoundationscomplete as per drawing and Technical specifications PCC M10.
116Fillling in foundation trenches using Local Sand as per drawing and technical specification Clause 305.3.9
117Laying Cement Concrete 600mm dia Pipe NP3 (burried conduits) on first class bedding of granular material in single row including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapet
118Plain/reinforcedconcreteinopenfoundationscomplete as per drawing and Technical specifications PCC M15.
119Drain covers RCC M25.
120HYSD Bar in R.C.C. work
121Supplying and fixing reinforced concrete heavy duty non-pressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Class NP3 of following internal diameter. (vi) 1200 mm dia. Class NP3 1000mm dia.
122Providing and fixing of precast RCC Guard Stone in M20( 1;2:4 ) Nominal Mix having section 0.25x0.25 M and Length 1.0 M fixed in M10 concrete of section 0.50x0.50 m in thickness 0.40 M as per drawing and technical specifications
123Providing and laying rubble for stone pitching (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls.(more than 10 ton)
124Providing and laying rubble for appron (each stone weighting not less than 40Kg.) including and packing and filing in the interestices with quarry-spalls. (more than 10 ton)
125Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604, 1202 & 1204 (1:3)
126Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204
127Plastering with cement mortar (1:4), 15mm thick on brickwork in substructure as per technical specification
128White washing of Culvert walls
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail