Special Repair To Bldg No P-145 To P-150 Including Roof Treatment , Replacement Of Internal Pipes And Sanitary Fittings, Special Repair To Bldg No T-09 T-10 Uunder Ge ( South ) Akhnoor, akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Special Repair To Bldg No P-145 To P-150 Including Roof Treatment , Replacement Of Internal Pipes And Sanitary Fittings, Special Repair To Bldg No T-09 T-10 Uunder Ge ( South ) Akhnoor. Submission Date for this Tender is 07-02-2022. Building Work Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30685205
Corrigendum : Special Repair To Bldg No P-145 To P-150 Including Roof Treatment , Replacement Of Internal Pipes And Sanitary Fittings, Special Repair To Bldg No T-09 T-10 Uunder Ge ( South ) Akhnoor
Open Tender
Indian
Jammu And Kashmir
akhnoor
07-02-2022

Tender Details

Special Repair To Bldg No P-145 To P-150 Including Roof Treatment , Replacement Of Internal Pipes And Sanitary Fittings, Special Repair To Bldg No T-09 T-10 Uunder Ge ( South ) Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jan-2022 FBIDCORRIGENDUMONE59 Financial Bid 31-01-2022
2 31-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

BOQ Items

Name of Work:SPECIAL REPAIR TO BLDG NO P-145 TO P-150 INCLUDING ROOF TREATMENT , REPLACEMENT OF INTERNAL PIPES AND SANITARY FITTINGS, SPECIAL REPAIR TO BLDG NO T-09 & T-10, PROVN OF HARD STANDING FOR REPAIR OF ‘A’ VEHICLE TANK T-55, TANK T-72 & BMP-II AND OTHER SANCTIONED WORKS AT AOR OF AGE B/R-II UNDER GE ( SOUTH) AKHNOOR
Sl. No. Item Description
1Dismantling of brickwork or stone/ boulder masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-In-Charge.
2Dismantling timber scantlings 40 Sqcm and over in section, in any position, complete all as specified and as directed by Engineer-In-Charge.
3Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engineer-In-Charge.
4Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-In-Charge.
5Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
6Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-In-Charge.
7Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed by Engineer-In-Charge.
8Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed by Engineer-In-Charge.
9Dismantlingof wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed by Engineer-In-Charge.
10Anodised aluminium snap grid frame work for false ceiling, powder coated, comprising of aluminium Tee (weight of section not less than 280 gms/mtr) and aluminium angle (weight of section not less than 280 gms/mtr), grid size 605x605mm, includingHangers 6.0mm dia, galvanised iron (upto1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of galvanised iron flat 40x3 mm size 60mm long and expansion hold fasteners 12.50mm dia, 40mm long including Perforated particle board/ tiles for insulation and accoustic purposes, 600x600 mm in size and 12mm thick, fixed with frame work (any type) or on snap grid, complete all as specified and as directed by Engineer-In-Charge.
11Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixedwithangle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed by Engineer-In-Charge.
12Rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, conforming to Fe 410-W (Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-In-Charge.
13Surface excavation not exceeding (not exceeding) 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
14Excavation in trenches n exc 1.5 metre wide & n. exc 1.5metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n. exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
15Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
16Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
17Filling of earth under floor including spreading and levelling in layers n exc. 25cm thick & well ramming including watering as required, complete all as specified and as directed by Engineer-In-Charge.
18Plain cement concrete M-5.0(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), as in sunken slab or as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
19Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
20All as per srl item No 19.00 above but except bricks.
21Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engineer-In-Charge.
22Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-In-Charge.
23Formwork for rough finish flat surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed by Engineer-In-Charge.
24Formwork for rough finish flat surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping), complete all as specified and as directed by Engineer-In-Charge.
25M&L RCC M-25 design mix using 20 mm graded stone aggregate as in slab supported on walls, beams and columns in floors, roofs landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
26Plain Cement concreteM-15, type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, all as specified.
27Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingexc 10 cm girth not exc 20 cm, complete all as specified and as directed by Engineer-In-Charge.
28Cutting openings, through brick walls in cement mortar for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hardcore to store and rubbish not exc. 50m etc,complete all as specified and as directed by Engineer-In-Charge.
29Forming jambs, etc. to openings (to foregoing item) built in cement mortar 1:6, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed by Engineer-In-Charge.
30Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only) and new work in CM 1:4, complete all as specified and as directed by Engineer-In-Charge.
31Plain cement concrete M-5(1:5:10), type E-2 (using 40mm graded crushed stone aggregate), 75mm thick, as in sub base of floors, finish even to recive floor finishes, complete all as specified and as directed by Engineer-In-Charge.
32Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by Engineer-In-Charge.
33Rendering 15mm thick, on other than fair faces of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
34Rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
35Rendering 15mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement), complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing compound shall deemed included in quoted rates.
36Precast reinforced cement concrete M-20(1:1.5:3), type A-1, (using 20mm graded crushed stone aggregate), nominal mix, as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs and similar articles with plain faces as specified in clause No- 4.11.16 of SSR Part-I (2009), set in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
37Rendering 10mm thick on any type of surfaces, on ceiling, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-In-Charge.
38Hardcore of broken stone, gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified. Note: thickness of hard core shall not exceed from 100mm.
39Butt hinges, size 100mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and as directed by Engineer-In-Charge.
40Aluminium handles, cast type, anodised, size 150mm, complete all as specified and as directed by Engineer-In-Charge.
41Aluminium anodised, barrel tower bolts of extruded Section, size 150mm long and fixed, complete all as specified and as directed by Engineer-In-Charge.
42Floor door stopper of cover plate 140mm, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engineer-In-Charge.
43Aluminium alloy, anodised, sliding door bolt, size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy,complete all as specified and as directed by Engineer-In-Charge.
44Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of chalk whitening, preparatory to distempering, after making surface smooth with 3mm thick birla white wall care putty, complete all as specified and as directed by Engineer-In-Charge.
45M&L for applying two coats of cement base paint on newly plastered surfaces of walls including preparation ofnew surfaces complete all as specified and directed.
46Preparation of old plastered or unplastered surfaces of walls and applying one coat of oil emulsion after preparing of surfaces, complete all as specified and as directed by Engineer-In-Charge.
47Preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of cement paint, complete all as specified and as directed by Engineer-In-Charge.
48Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-In-Charge.
49Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
50Non-skid, joint free, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, set and fixing in skirting/ dado or any other vertical surfaces and pointed in white or coloured cement to match and including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed.
51Glazed ceramic tiles in vertical surface/ dado, size 300x450x7mm thick, 400x400x6/7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, the shade/ colour of tiles including 10mm thick rendering in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
52Non-skid, coloured, ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including laid over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
53Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), ncluding cleaning,removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed by Engineer-In-Charge.
54Plain cement concrete M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregate), nominal mix, 40mm thick, as in floors, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
55Glass dividing strips, 3.0mm thick and 38mm wide, as in flooring, complete all as specified and as directed by Engineer-In-Charge.
56Plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate), 50mm thick, as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight, complete all as specified and as directed by Engineer-In-Charge.
57Machine cut kota stone slab, (minimum size shall be 550x550mm), flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6, complete all as specified and as directed by Engineer-In-Charge.
58Machine cut kota stone slab, (size shall in one length), 12mm thick, as in riser of steps, skirting, dado and pillar, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, and including laid over screed bed or back plastering layer of mortar 15mm thick in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
59Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 100mm thick of plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
60Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, laid over and including 30mm thick well rammed sand cushion laid over and including sub base of 150mm thick of plain cement concrete M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), with grey cement and no pigment, complete all as specified and as directed by Engineer-In-Charge.
61Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed by Engineer-In-Charge.
62Factory made, 35mm thick, second class hardwood, plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and as directed by Engineer-In-Charge.
63Factory made steel window, box type, using ERW hollow "P" section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and plain sheet glass3.0mm thick, 4mm thick frosted glass, jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed by Engineer-In-Charge. Note :- Cost of window shall include all members and spare parts as elaborated in the Drwaing and in the specifications and nothing shall be paid extra seperately.
64Dismantling of old/ damaged existing roof treatment with concrete and cleaning all waste and dirt by wire mesh, picking, sweeping and washing down with water to remove dust, etc, and removal of all material out side the Cantt area, complete all as specified and as directed by Engineer-In-Charge.
65Applying one coat of neat cement slurry with 3.0 Kg of cement per Sqm on cleaned surfaces of roof, evenly, and screed bed/rendering 10mm thick on fair faces of brick work or concrete surfaces, in cement mortar 1:4, including mixing water proofing compound @ 3% by weight in cement, rendering is to be finished even and smooth (without using extra lime or cement) including Water proofing treatment on roof top with APP (Ataxic Poly Propylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density polyethylene film, minimum weight not less than 3.0 Kg/ Sqm, 2.0mm thick, centre core is sandwiched on both sides by high quality polymeric mix with properties of high softening point, high heat resistance and cold resistivity to make it ideal for all water proofing treatment, with polymeric mix protection on both sides with 20 micron HMHDPE film, laid over one coat of bituminous primer conforming to IS: 3384, applied @0.40 Kg/ Sqm and one coat of hot blown bitumen of 85/25 grade, conforming to IS:702, applied @1.20Kg/ Sqm on prepared surfaces of roof, overlap should be not less than 150mm at ends and 75mm at sides, joints and overlaps uniformly bounded with LPG torch flame including applying of one coat of semi hot blown bitumen of 85/25 grade, @1.20 Kg Sqm and fine screened sand in dry condition @0.50 Kg/ Sqm after laying the membrane and applying two coats of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. Note: Cost of water proofing chemical shall be included in quote rate.
66Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each, complete all as specified.
67Taking down of chowkhats or frame with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.0 Sqm each, complete all as specified.
68Solid PVC Door Frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplyingand fixing in opening as per specification and drawing, including making good to disturbed surface of walls, complete all as specified and as directed by Engineer-In-Charge.
69Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing in SSR, complete all as specified and as directed by Engineer-In-Charge.
70M & L for preparation of newly plasteredsurfaces of ceilings and applying three coats of white wash complete all as specified and directed.
71Vitreous China wash basin (full pedestal type), size 605x500 mm, white, design and accessories as per cat part and making good to dismantled/ damaged wall in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Design- Camber (Cat part No- S2040154 for wash basin and S2090125 for full pedestal) of Cera or equivalent in Johnson/ Hindware/ Jaquar.
72Vitreous China wash down water closet pan (pedestal pattern), size 660x350x710mm, white, in one peice, design and accessories as per cat part and making good to dismantled/ damaged wall in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No- S1013109 (S Trap 220 mm) of Cera or equivalent in Johnson/ Hindware/ Jaquar.
73PVC (SWR) floor trap of 75mm dia outlet, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-In-Charge.
74PVC (SWR) vent cowl, of 75mm bore, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
75PVC (SWR) junction single, (Single T) equal or unequal, of 110mm bore, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
76Taking up or down steel tubing of 15mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
77Tubes, "medium grade" galvanised, 15mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
78Refixing old steel tubing galvanised, 15mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
79Taking up or down steel tubing of 20mm bore pipe and connections, including cleaning for re-fixing or removal to store, complete all as specified and as directed by Engineer-In-Charge.
80Tubes, "medium grade" galvanised, 20mm bore, ISI markedwith all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts, etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-In-Charge.
81Refixing old steel tubing galvanised, 20mm bore, with all fitting such as bends, tees, elbows, unions, short pieces, connectors, back nuts and connections in new or old position (walls, ceiling, floors, etc.), complete all as specified and as directed by Engineer-In-Charge.
82Angle valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for 15mm bore pipe, fixed in repairs, complete all as specified and as directed.
83Stop valve, cast copper alloy, chromium plated, fancy type, concealed type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
84Stop valve, cast copper alloy, chromium plated, fancy type, concealed type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
85Swivel over head shower with arms of PTMT any colour for fixing with 15mm pipe, (Minimum weight 40gms), fixing in repairs, complete all as specified and directed by Engineer-In-Charge.
86PVC connections 15mm size with brass nuts of length 450mm, complete all as specified and as directed by Engineer-In-Charge.
87Bib taps, long body, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
88Centre hole basin mixture for hot and cold water, chromium plated, with round sport without pop up waste system for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1013451 of Cera/ Jaquar/ Parko/ Hindware.
89Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve 20mm dia with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes.
90Low density polyethylene (LDPE) pipes of 32mm bore, pressure rating 6.0 Kgf/Sqcm), 900mm long, complete all as specified and directed by Engineer-In-Charge.
91Tubular towel rail, 20mm dia, D-type, 60cm long between flanges, brass chromium plated, fancy type, including end brackets, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
92Wall mixer with bend pipe for overhead shower with built-in non return valve, for hot and cold water, chromium plated, for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge. Make: Cat Part No-F1014402 of Cera/ Jaquar/ Parko/ Hindware.
93Sinks with drainage board made of stainless steel 1.0mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
94Glass corner shelf, made with 6 to 8mm thick transparent glass, three teirs including anti rust screws,complete all as specified and as directed by Engineer-In-Charge.
95Hand shower (Health faucet), ABS body with 8mm dia and 1.0mtrs long SS braided flexible tube with wall hook, complete all as specified and as directed by Engineer-In-Charge. Make: Cera cat part No- F8030101 or equivalent in Orient/ Jaquar/ Riviera.
96Sheet glass shelf assembly, consisting 5.50mm thick sheet glass, 120mm wide including anti rust screws, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
97Soap dish, fancy type, fixed to plugs with chromium plated brass screws, complete all as specified and as directed by Engineer-In-Charge.
98Toilet paper holder, fancy type and chromium plated, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
99Stainlees steel grating, chromium plated, size 125mm, heavy duty, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
100Replacement of old unserviceable/ damaged600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
101PVC (SWR) bends of 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
102PVC (SWR) bends of 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, any radius, fixing with adhesive, complete all as specified and as directed by Engineer-In-Charge.
103PVC (SWR) pipes, 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
104PVC (SWR) pipes, 75mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, fixed on wall with mild steel/ PVC clamps, complete all as specified and as directed by Engineer-In-Charge.
105PVC (SWR) pipes, 110mm bore, pressure capacity not less than 4.50 Kgf/Sqcm, single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and as directed by Engineer-In-Charge.
106PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, capacity 10.0 litres and making good to dismantled/ damaged surfaces, fixing in repair, complete all as specified and as directed by Engineer-In-Charge.
107Rotational moulded polyethylene water storage tanks of 1000 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed.
108Rotational moulded polyethylene water storage tanks of 500 liters capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20mm bore pipe, fixing in repairs, complete all as specified and as directed.
109Septic tank for 25 users LLDPE (Linear Low Density Polyethylene) with upflow filter including media type with vent pipe, cowl etc. designed to carry sewage and sullage water, including excavation in any type of soil as per size of tank , PCC 1:4:8 Type D-2(using 40mm graded crushed stone aggregates)as bed concrete, lowering the septic tank and filling with water and return/filling with mix of coarse sand and Bajri around the septic tank and do inlet and outlet pipe connection etccomplete all as specified and as directed. Make: Sintex /Comfort polymers/ Polycon.
110Plain cement concrete Nominal Mix M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
111Plain cement concrete M-10(1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge.
112Salt-glazed stoneware drain pipes, internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge.
113Brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:4, complete all as specified and as directed by Engineer-In-Charge.
114Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and as directed by Engineer-In-Charge.
115Point wiring (concealed to surfaces) for one light/ fan/ bell point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit,fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheathed 1.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
116Description all as per serial item No- 115.00 here in before but for one 3-pin socket outlet 5-Amps on the independent board.
117Description all as serial item No- 115.00 here-in-before but for one 3- pin, 5-Amps, socket outlet on same board.
118Point wiring for 3-pin, 15 Amps, switch socket combination on independent board with 2.50 Sqmm, PVC insulated, unsheathed, single core, multi-stranded, copper conductor cable, FRLS, 1100 Volts, using colour coding, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 20mm dia including all accessories concealed by chasing/ cutting in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, with and including sunken type pressed steel/ welded mild steel terminal box 1.20mm thick coated with anti corrosive paint and with bakelite laminated sheet top cover 3.0mm thick and including FRLS PVC green insulated unsheeathed 2.50 Sqmm copper earth continuity wire connected to earth dolly, complete all as specified and as directed by Engineer-In-Charge.
119S&F LED tube light fitting, 20 watt, indoor decorative aluminium extruded T5 LED battens, including LED lamp of 20 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-In-Charge. Make: Havells cat part No- ENDURALINEARNEOBS 20WLED830SPCWH or equivalent in Bajaj/ Philips/ Wipro.
120Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt, complete all as specified. Make: Havells ordering cat part No- HEXAFT10WLED857SSYMBOPC or equivalent in Bajaj/ Philips/ Wipro.
121Supply and fixing, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 metre apart Including 4.0mm suspension wire, one twin core cable flat or circular, complete all as specified and as directed by Engineer-In-Charge.
122Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
123Ceiling rose, three phase/ PVC/ polycarbonate, isolated body, complete all as specified and as directed by Engineer-In-Charge.
124Switch socket combination, 2-in-1, 3-pin, 5-Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
125Socket socket combination , 2-in-1, 3-pin, 5 and 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
126Lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-In-Charge.
127T bulb curve, 12 Watt LED base B22 cool day light, complete all as specified and as directed by Engineer-In-Charge.
128S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
129S&FMCB, Single Pole and Neutral, 40 Amps, 240 volts, 50 Hz, "C" curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
130S&F MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
131S&F in replacement of LED security/ street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection, including LED lamps of 30 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified. Make: Havells cat part No- Endura Citylite Platinum Plus SL30WLED757SASYBOPC/ Bajaj ordering code No- 169907 (Product Code- BRLEP 30W LED WH)/ Philips ordering code No- 910925452299 (Product Code- 871869632003700).
132Replacement of old unserviceable/ damagedSub main wiring (concealed conduits to surfaces) for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 2.50 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications, complete all as specified and as directed by Engineer-In-Charge.
133Description all as per serial item No- 132.00 here-in-before but for sub main wiring (in new conduits concealed to surfaces) alongwith earth wire with two run of 6.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts.
134S&F in replacement ofCeiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, complete all as specified and as directed. Make: Havells / Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
135Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 4-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
136Exhaust fan, mettalic, sweep 250/ 230mm, superior rating for energy saving,mettalic blades, copper wounded motor complete with electronic fan regulator including hanging accessories i.e. U-clamp,canopy and nut bolts, washers, complete all as specified. Make: Havells cat part No- FHVDBMTGRY09 (Ventilair DB Neo)/ Crompton Greaves/ Usha/ Bajaj/ Orient.
137S&FEarthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt fillingwith fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i)Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
138Replacement of old unserviceable/ damaged Cable and Supply, laying commissioning, testing ofthe XLPELT cable 1100 volts grade of size 10 Sqmm 2 core armoured, PVC sheathed with aluminium conductor heavy duty laid in trenches/fixing on wall in PVC conduit pipe with the help of clamp/shadels, under road crossing through protection pipe etcafter taking out existing under ground cablecomplete all as specified and directed.
139Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/drains etc, complete all as specified.
140Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
141Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
142Amount of Schedule of credit of for Rs 53,405.00.00 shall be deducted from quoted amount.