87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam, ARAKKONAM-Tamil Nadu

Military Engineer Services-MES has published 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam. Submission Date for this Tender is 03-01-2022. Infrastructure Work Tenders in ARAKKONAM Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

30391519
Corrigendum : 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam
Open Tender
Indian
Tamil Nadu
ARAKKONAM
03-01-2022

Tender Details

87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam 87652 Provision Of Infrastructure For Asr And Mssr At Rajali, Arakkonam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-01-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 192000.0 /-
Tender Value
INR 1.17 Crore /-

BOQ Items

Name of Work: PROVISION OF INFRASTRUCTURE FOR ASR AND MSSR AT RAJALI, ARAKKONAM (TENDER ID: 2021_MES_477874_3)
Sl. No. Item Description
1GENERAL SUMMARY
2BUILDINGS/ STRUCTURES Note: This schedule is not prepriced by MES and prepriced rate indicated as "Rs.0.00" under Col.5 indicates this fact only.
3Construction of RCC framed structure Radar tower of 22.50 M staging height with staircase and construction of Cabin room over the staging and provision of RCC antenna base over the roof of the cabin room all as per drawing and particular specifications and as directed.
4Construction of RCC framed structure Antennatower of 10 M staging height with staircase complete all as per drawing and particular specifications and as directed.
5Construction of RCC framed structure UPS room all as per drawing and particular specifications and as directed.
6Construction of RCC framed structure Antenna Cabin Room all as per drawing and particular specification and as directed
7NOTE: Schedule ‘A’ Part - II to X are prepriced by MES under Ser No. 8.00to 16.00 Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
8Lumpsum price worked out by the contractor for “DEMOLITION / DISMANTLING ” as listed in Schedule ‘A’ Part - II , on Serial Page No.22
9Lumpsum price worked out by the tenderer for"INTERNAL ELECTRIFICATION" as listed in Schedule "A" Part-III on Serial Page No.24
10Lumpsum price worked out by the tenderer for "FIRE ALARM" as listed in Schedule ‘A’ Part-IV on Serial Page No.25
11Lumpsum price worked out by the tenderer for "CIVIL WORKS" as listed in Schedule ‘A’ Part-V on Serial Page No.30
12Lumpsum price worked out by the tenderer for "LIGHTENING PROTECTION" as listed in Schedule ‘A’ Part-VI on Serial Page No.31
13Lumpsum price worked out by the tenderer for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-VII on Serial Page No.32
14Lumpsum price worked out by the tenderer for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VIII on Serial Page No.34
15Lumpsum price worked out by the tenderer for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-IX on Serial Page No.35
16Lumpsum price worked out by the tenderer for "RAIN WATER HARVESTING" as listed in Schedule ‘A’ Part-X on Serial Page No.37
17Subtotal
18NOTE:Schedule ‘A’ Part - XI is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
19SCHEDULE "A" PART - XI (MISCELLANEOUS ITEMS) (To be quoted by Bidder)
20Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor wire drawn intoexistingconcealedconduit including provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel terminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following point wiring :-
21One light point controlled by one switch.
22One fan point controlled by one switch.
23One Exhaust fan point controlled by one switch.
24One 3 pin socket outlet 5 Amps, same boardwith cables 1.5 Sqmm size.
25One 3 pin socket outlet 5 Amps, independentboardwith cables 1.5 Sqmm size.
26All as per item ser no-20 above here in before but one 3 pin socket outlet 5/15 Amps, independentboardwith cables 4.0 Sqmm size.
27Material and labour point wiring with 1.5 Sqmm single core PVC insulated FRLS unsheathed multi stranded copperconductor drawn into and includingPVC concealed (fixed on wall/roof/ceiling etc),conduit of size not less than 20 mm diaand including provision of 1.5Sqmm single core PVC insulated FRLS unsheathed multi stranded copper conductor as earth wire and cast iron / pressed steel terminal boxes for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover complete for the following :-
28One light point controlled by one switch.
29One fan point controlled by one switch.
30One Exhaust fan point controlled by one switch.
31One 3 pin socket outlet 5 Amps, independentboardwith cables 1.5 Sqmm size.
32All as per item ser no-22 above here in before but one 3 pin socket outlet 5/15 Amps, independentboardwith cables 4.0 Sqmm size.
33Taking down old aluminium unserviceable sub main wiringof any size including connected accessories etc.,complete all as specified and as directed.
34Supply and fix high efficiency wall mounted LED batten type not less than18W 4 ft LED light fitting and including taking down old unserviceable fittings all as specified and as directed . Make: C & S Cat Part No. LCTL-18-CDL or equivalent in any of the makes given in PS
35Supply and fix high efficiency wall mounted LED batten type not less than 9W 2 ft LED light fitting and including taking down old unserviceable fittings all as specified and as directed. Make: C & S Cat Part No. LCTL-9-CDLor equivalent in any of the makes given in PS
36Supply and fix Energy savingnot less than 25 Watts LED light fitting ,IP65 powder coated pressure die cast aluminium high power street light with heat resistant toughened glass with lens by providingGI pipe medium grade 25 mm dia 1.5 Mtrin length with suitable size MS Clamp two nos made out of 25x3 mm FI incl two coat of synthetic enamel paint over a coat of red oxide primer, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm from ceiling rose to fitting and including taking down old u/s damagedall as specified. Make: C & S Cat Part No. LSTS-25-CDLor equivalent in any of the makes given in PS
37Supply and fixing sheet metal enclosurevertical TPN MCCB DB 4 way double door with spreader terminals, insulating phase barrier and hardware with necessary arrangements all as specified and directed Note :-(i) Including taking down old u/s DB, MCCB and MCB"s (ii) MCCB and MCBs shall be measured and paid separately under the respective item of schedule.
38Supply and fix for MCCB 4 Pole, 415 V, adjustable Thermal & Fixed Magnetic setting type 125 Amps with breaking capacity 25 KA complete all as specified and as directed
39Supply and fix for MCB SPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed
40Supply and fix for MCB SP 230 V, 6-32 Amps with breaking capacity 10KA C curve complete all as specified and as directed.
41Material and labour for Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level , with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected with and incl GI earth wire 4mm dia including alternate 5 layersof charcoal, salt crystal and including 15 mm dia GI pipe light grade by means of nuts, bolts, washers and necessary earth work upto 7.5 mtr and connecting to test point, LT Switchgear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC Cover with 6 mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No 3 of SSR Pt- I including testing on completion complete all as specified and as directed. Note:(i) Quoted rate deemed to include necessary earth work PCC chamber, RCC cover, reinforcement, removal of surplus soil , site clearance etc.
42Supply and erect cable tray size 300 mm (W) X 80 mm (H) X 3 mm (T)made up of perforated hot dip galvanized iron sheet of gauge 14 SWG duly powder coated with coupler plates tee horizontal bend etc with coupler plates, tee, horizontal bend,vertical,etc with necessary arrangements to fix on wall complete all as specified andas directed.
43Supply and fix heavy duty exhaust fan with louvers ,300 mm sweep, AC, single phase, 230/240 volts all as specified and as directed by the Engineer-in-Charge
44Supply and fix in repairs high efficiency24 watts2 x 2 sqft LED light with panel for recessed/surface mounting dust free installation with high brightness LEDsfor glare free homogenous illumination and suitable for ceiling cut out 600 x 600mm all as specified and as directed by the Engineer-in-Charge. Make: C & S Cat Part No.LCTLSN-24-CDLor equivalent in any of the makes given in PS
45Supply and fix for MCB TPN 230 V, 40-63 Amps with breaking capacity 10KA C curve complete all as specified and as directed .
46Supply and fix copper cable armoured electric cable,1100 volts grade strandedcopper conductor of size 1.5 sqmm , 2 core all as specified and as directed
47Material & Labour for ESRG Low flange width steel cement cavity flooring system of size 600mm X600mm Floor Panels of (max 4 mm thick ) over a height of 0.3 m from floor level of approved color complete all as specified and as directed
48Material and labour for Applying a coat of bituminous aluminium paint @0.10kg/Sqm as weather proof coat all as specified and as directed by the Engineer-in-Charge.
49Taking down steel rolling shutters of size (2mX2.8m) with all accessories complete.
50Taking down steel rolling shutters of size (2mX2.65m)with all complete all as specified and as directed .
51Material and labour for motorized rolling Shutter of size 2.0mwide and 2.80 m height (clear size) as per IS 6248 made of 19 gauge steel laths interlocked together at the end by end locks mounted on MS pipe shaft with necessary brackets 75 mm wide guides and bottom plate with Powder coated finish as per approved colour consisting of single phase compact type gear system with push button control & emergency manual chain set including top cover & motor cover complete all as specified and as directed .
52Material and labour of motorizedrolling Shutter of size 2.0mwide and 2.65 m height (clear size) as per IS 6248 made of 19 gauge steel laths interlocked together at the end by end locks mounted on MS pipe shaft with necessary brackets 75 mm wide guides and bottom plate with Powder coated finish as per your approved colour including Single phase compact type gear system with push button control & emergency manual chain set including top cover & motor cover complete all as specified and as directed .
53Supply and fixing 100 mm size Stainless steelhinges medium weight cold rolled mild steel and fixed with screws complete all as specified.
54Supply and fixing in repairs32mm dia bore PVC waste pipe for wash basin complete all as specified and as directed by Engr-in-charge.
55Supply and install air cooled split Air Conditioner electric driven single phase of capacity 1.5TR with copper condenser coil, green gas, mounting stand with all accessories, 100% copper (for indoor units and mounting kits) as per BEE "Ministry of Power" Goverment body ISEER table valid from 2018 to Dec 2020 equivalent to 5 star rating of EER for Jan 2016 to Dec 2017, complete all as specified and as directed. Note: Extra length of copper tubing with insulation, as per site requirement is deemed to be included in the rate quoted.
56Supply and install Air cooled split Air Conditioner electric single phase of capacity of 1TR with copper condenser coil, green gas, mounting stand with all accessories, 100% copper (for indoor, outdoor units and mounting kits) Note: Extra length of copper tubing with insulation, as per site requirement is deemed to be included in the rate quoted.
57Supply and fixing forsheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete withoneSP MCB 20 to 32 Amps complete all as specified and as directed by the Engineer-in-Charge.
58Supply and install Voltage stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and capacity 3KVAcomplete all as specified and as directed.
59Supply and install Voltage stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and capacity 2KVAcomplete all as specified and as directed.
60Fixing onlyAluminium strip with saddles (ebonite insulator) and fixing screws etc. for roof conductors and down conductors above ground upto 20m height Including necessary fixing arrangement like scaffolding, ladder etc complete all as specified and as directed.
61Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4)type B-1cover and watering pipe 20 mm dia medium grade with funnel complete with mesh , refilling with black cotton soil all as specified. Note:(i) Quoted rate deemed to include necessary earth work PCC chamber, RCC cover, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separately under the respective item of the schedule (iv) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtainedthe earthing will be re done by the contractor at no extra cost.
62Supply and fix energy saving ,street light fittings LED 40 watts luminaries with high power LEDs and unique flood optics to ensure uniform distribution and saving upto 50% w.r.t conventional systemand maintenance free system ,ideal for area lighting , high mast and bill board including fixing arrangement on pole by providingGI pipe medium grade 25 mm dia 1.5 Mtrin length with suitable size MS Clamp two Nos made out of 25x3 mm FI, prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to fitting all as specified andas directed by Engr-in-Charge. Make: C & S Cat Part No. LSTS-40-CDL or equivalent in any of the makes given in PS
63Supply,Install,Testing and commissioning of self supporting totally enclosed mounted on Base channel of size 75 mm x 75 mm x5mm Indoor type LT Panel from CPRI certified Panel builder factory fabricated made out of not less than 2 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (32 x 6 mm) connecting provision - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etcpanel board suitable for3 phase 4 wire ,415 volts 50 Hz,panel size shall besuitable for mounting and including the following itemscomplete all as specified and directed as per IS/IEC/61439,182 internal arc conforming65 KA/sec and factory fabricated
64(i) MCCB with adjustable type 250 Amps 4P, 50 Hz, 415 Volts with rupturing capacity 35 KA -01 No (as incomer). (ii) MCCB with adjustable type 200 Amps 4P, 50 Hz, 415 Volts with rupturing capacity 25 KA -02 Nos (as out goings). (iii) Aluminium Bus Bar of 400 Amp rating main bus @ 50 KA supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with colour coded PVC sleaving for three phase and neutral -01 Set. (iv) Resin cast current Transformer-3Nos (v) Digital voltmeter - 1 No(vi) Digital Ammeter - 1 No(vii) LED Phase Indication Lamps for R,Y,B -3 Nos. (viii) Earth bus of size 32 x 6 mm in the panel - 2 Nos
65Supply,Installing,Testing and commissioning of self supporting totally enclosed mounted on Base channel of size 75 mm x 75 mm x5mm Indoor type LT Panel from CPRI certified Panel builder factory fabricated made out of not less than 2 mm thick CRCA sheet ,dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip (32 x 6 mm) connecting provision - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etcpanel board suitable for3 phase 4 wire ,415 volts 50 Hz,panel size shall besuitable for mounting and including the following itemscomplete all as specified and directed.
66(i) MCCB with adjustable type 200 Amps 4P, 50 Hz, 415 Volts with rupturing capacity 25 KA-01 Nos(as incomer). (ii)Aluminium Bus Bar of 300 Amp rating main bus @ 50 KA supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with colour coded PVC sleeving for three phase and neutral -01 Set. (iii) MCCB 100 A 4P, 50 Hz, 415 Volts with rupturing capacity 16 KA-02 Nos (out going). (iv) MCB ,63 A 4P,50 Hz, 415 Volts with "C" curve- 4 Nos(out going) (v) Resin cast current Transformer-3Nos (vi) Digital voltmeter - 1 Nos (vii) Digital Ammeter - 1 Nos (vii) Ammeter selector switch 6A,4 P - 2 Nos. (ix) LED Phase Indication Lamps for R,Y,B -3 Nos. (x) Earth bus of size 32 x 6 mm in the panel - 2 Nos
67Taking down the existing cable tray any size and any description and taken as schedule of credit
68Material and labour for erecting and placing in position hume pipe septic tank for 5 users, 600 mm dia with two chambers, including excavation in any type of soil, foundation in PCC 1:4:8 , vent pipes etc., complete all as specified in drawing and as directed by Engr-in-charge. Note: Refer drawing No. TD-120 of CWE(Navy) Chennai and PS for detailed specification.
69Material and labour for construction of soakage well of internal size of1.2 m dia and 3 m depth,including excavation in any type of soil, foundation in PCC 1:3:6,brick work in CM 1:4 for solid/honeycombed walls and including intercepting chamber, RCC cover slab in M-25/SFRC cover, filling with brick bats etc, complete all as specified in drawing and as directed by Engr-in-charge. Note: Refer drawing No. TD-100 of CWE(Navy) Chennai and PS for detailed specification.