}

Construction Of Kgbv Building With Academic And Hostel, SSA Assam Kahilipara Guwahati-Assam

Axom Sarba Siksha Abhijan Mission has published Construction Of Kgbv Building With Academic And Hostel. Submission Date for this Tender is 04-01-2022. Building Work Tenders in SSA Assam Kahilipara Guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

30376179
Construction Of Kgbv Building With Academic And Hostel
Open Tender
Indian
Assam
SSA Assam Kahilipara Guwahati
04-01-2022

Tender Details

Construction Of Kgbv Building With Academic And Hostel

Key Value

Document Fees
INR 5000 /-
EMD
INR 382578.0 /-
Tender Value
INR 1.91 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF KASTURBA GANDHI BALIKA VIDYALAYA (CLASS VI TO X) ( ACADEMIC BLOCK ASSAM TYPE WITH RCC HOSTEL BUILDING (G+2)) (KGBV-TYPE-II), LUMDING, HOJAI
Sl. No. Item Description
1CIVILWORKS:Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Upto a depth of 2.00 m below the existing G.L. (a) In ordinary soil
2Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. © With silt (predominantly non plastic) by truck carriage including loading and unloading.
3Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b). In prop. 1:4: 8(1 cement:4 coarse sand : 8 coarse agg. by volume (using mixture machine)
4Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine(A) In sub - structure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N (b) M20 or Prop. 1:11/2:3
5Providing and laying plain/reinforced cement croncrete works..(B) Super-structure from plinth level upto 1st floor level. (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N (b) M20 or Prop. 1:1.5:3
6Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
7Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (I) Using 38mm thick plank
8Providing form work..Sides of tie beams, grade beams etc. at or below ground level. (i) Using 38mm thick plank
9Providing form work...Columns, Pillars, Posts & Strut. (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. (i) Using 38mm thick plank
10Providing form work...Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (i) Using 38mm thick plank
11Providing form work...Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (i) Using 38mm thick plank
12Providing form work...Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
13Reinforcement :Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). (a) TMT-ISI approved super ductile.(i) TATA/SAIL
14Providing brick soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. (a).Brick on flat soling.
15Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (c). In proportion 1:5.
161st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately) A) 112 mm thick brick wall. (b). In cement mortar in proportion 1:5.(1 cement:5 sand)
1725 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finishto be laid in panelsincluding curing complete as directed.
18Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
19Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. i) 15mm
20ProvidingCeramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). a) Normal range (sizes 300mmx300mm and above). i) Orient made
21Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).a) Normal range( Somany/ Orient/ Nitco/….)i) Of Sizes 200 mm x 200mm and above
22Pre cast cement concrete tiles 20mm thick with aggregate of sizes upto 6 mm laid in floors,treads of steps and landing with 20mm thick bed of cement mortar in prop. 1:6 (1 cement : 6 coarse sand ) joined with neat cement slurry with pigment to match the shade of the tiles complete with pre-cast tiles of: c ) Any shade or combination of shades using grey cement .
23Pre cast cement concrete tiles 20mm thick with aggregate of sizes upto 6 mm laid in floors,treads of steps and landing with ….Extra over item no.5.2.1 for rubbing and polishing the cement concrete tiles in flooring, skirting, dado etc.
2410 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d). In cement mortar 1:6
2515 mm thick Cement plaster in single coat on rough side of single or half brickwall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.(d). In cement mortar 1:6
26Providing ,fitting and fixing powder coated pressed steel door frame made of 1.25 mm / 1.6 mm thick sheet of various sizes with necessary hinge jamb , lock jamb , head and steel base ties at the bottom of the frame . The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20 x 20 x1.25mm thick. Frame to be fitted up with 1:4:8 P.C.C after fitting the frame with brick/concrete works etc. complete as directed by the department for all levels. )P.C.C to be measured and paid for separately) (a). 1.25mm thick sheet. (iii) Size 125mm X 60mm (Single rebate)
27Providing ,fitting and fixing Syntex PVC door frame made out of extruded PVC section in an overall size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm , + 0.3 mm with special polymeric reinforcement having an overall size of 30mm x 25mm width , 150mm length at hardware location . The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fittings
28Providing ,fitting and fixing 24mm/29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges , screws,bolts etc as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) a)(24mm thick)
29Providing wood work in frame of false ceiling partitions etc.sawn, wrought, framed hoisted and fixed in positon with spikes, nails, M.S flat,angle/ cleats with bolt and nuts complete including kiricide oiling two coats to unexposed surfaces of the timber (M.S flats, angle cleats, and bolt and nuts required for flat, angle cleats wherever necessary shall be measured and paid separately). (b). With Hollock/ Bonsum/Sundi/Gamari
30Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
31Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measuredand paid separately ) . B).With 1st class local wood(Hollock / Bola/ Bonsum/Gamari). B.(ii). 35 mm thick.
32Supplying, fitting and fixing 30mm thickflush door(single leaf finished) made of phenol bonded Duratuff exterior grade (both side) plain medium density fibre board . The door should be fixed using 4 nos of hinges 125mm long ensuring that the hinges are not fixed less than 150mm from the edges with 8 nos. parallel sunk fully threaded screws 38mm long, should be used for fixing the hinges to the flush door after drilling a pilot hole 2.50mm dia 40mm long . Screws should not be hammered . Lock, tower bolts etc. necessary, if any to be paid separately. (a). 30mm thick. ii). One side teak and other side commercial.
33Providing, fitting and fixing steel windows of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15mmx13mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mmx12mm sq. bars duly welded to steel frame at not more than 12cm c/c applying a priming coat of red-lead paint etc. complete as per drawing. a) Openable
34Providing, fitting and fixing steel windows of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15mmx13mmx100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65mm and not less than 15mm wide) bolting device, steel handles, pegs, stays of 300mm long etc. complete including providing 12mmx12mm sq. bars duly welded to steel frame at not more than 12cm c/c applying a priming coat of red-lead paint etc. complete as per drawing.b) Fixed
35Providing and fixing plain with special metal, sachputty and glazing clip in steel window / doors /cleastory windows including necessary cutting to required sized for all floors.(1).Clear sheet glass panes (v). 5.00mm thick.
36Providing and fixing in position collapsible M.S.SQ.m Rs.4245.50 shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
37Providing ,fitting and fixing Hard board sheet in ceilling with necessary nails, wood screws including 1st class local wood 50mm x 12mm (hollock/bonsum/sundi) beading including paint ing two coats to timber beads complete as directed( ceilling joist tobe measuredand paid separately). (b) 4.5 mm thick
38Providing, fitting and fixingM.S.grillof requiredpattern for windows/ clerestory windows/ openingwith M.S. flatsat required spacingin frame all round,squre or round M.S.bars with round headed bolts and nuts or screws. I. Plain grill. (c). Fixed to Brickwork/P.C.C/R.C.C.
39Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black-tubes conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.(TATA make circular hollow.....
40Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ). a) Sliding door bolts. ii) 250mm x 16mm
41Supplying, fitting, fixing anodised aluminium fittings..b) Tower bolts. ii) 250mm x 12mm
42Supplying, fitting, fixing anodised aluminium fittings..iii) 200mm x 12mm
43Supplying, fitting, fixing anodised aluminium fittings..c) (Door Handle). ii) 100mm
44Supplying, fitting, fixing anodised aluminium fittings..iii) 150mm
45Supplying, fitting, fixing anodised aluminium fittings..j.Fan Light Pivot
46Supplying, fitting, fixing anodised aluminium fittings..t) Door stopper with rubber stopper
47m) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth. (i).Priming coat with distemper primer
48a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
49b) Finishing wall with water proofing cement paint of approvedbrand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
50Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
51Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
52Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm). (ii)Thickness = 1.0mm thick
53Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). (B) (i) 0.50 mm thick
54Providing galvd iron ridging of TATA SHAKTEE / SAILincluding supplying and fixing necessary galvd screws/washers etc. complete as directed. (d) 0.60 mm thick (ii) 230 mm lapping
55Providing Pre Painted Galvalume Sheet Roofing(PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (a) (Dyna roof /TATA Blue Scope/Wooden Roof) . (v) 0.60 mm thick
56Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing)at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (v) 0.60 mm thick
57Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
58Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
59Providing, supplying, mixing, laying 8mm thick cement Plastering in prop.1:6 over R.C.C. surfaces mixed with integral waterproofing compounds like Master Proof IWP-1 of Choksey Chemicals /Dr. Sealkit No.1 (Asian Chemicals) /Rheomac 707 of BASF@ 0.2% by weight of cement conforming to IS:2465 as specified and directed by the Department complete.
60Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG). BRAND : FIRESTOP / FIREND / FIRE SHIELD/GETECH/MINIMEX
61Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete..a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
62Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
63Applying priming coat over newwood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
64Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
65INTERNAL WATER SUPPLY WORKS:Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. b) 40 mm dia. i) Using Tata (medium)
66Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand...e) 20mm dia. i) Using Tata (medium)
67Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary "R" brand..f) 15 mm dia. i) Using Tata (medium)
68Supplying, fitting and fixing 87.5 degree PVC bend of(Supreme/Prince) or other ISIapproved including joining ,fitting and fixingetc.as necessary completeat all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches.(i) 160mm dia.
69Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) (VI) Sona brand.(ii) Bib Cock ( Code.No.CL-5022)Long Body
70Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (IV) Sona brand. (a) Stop cock male/female 15mm Angle Stop Cock
71Supplying fitting and fixingpush bib cock 15mm diacomplete as directed and specified as follows.(pipes will be measured and paidseperately). (I) CPCH. a) Light type
72Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (I) SONA make. (a)Light type
73SANITARY WORKS:Providingfitting and fixing white vitreous water closet squatting pan (Indian type W.C Orissa pattern) of size 580 x 440 mm with 100 mm SCI "P" or "S" trap, 10 litre low level vitreous flushing cistern with manually controlled device(handle lever) of SONA make with all fittings and fixtures complete including cutting and making good the walls and floors whereever required. (a) White(Parryware make)
74Providing fitting and fixing white vitreous china pedestal type watercloset (European type W.C pan 400mm high) of Parryware/ Hindware makewith seat and lead ,CP brass hinges and rubber buffers, 10 litre low level white china vitreous flushing cistern with fittings, CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, cutting and making good the walls and floors whereever required. (a) White (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)
75Providingvitreous china wash basin of size 550mm x400mmof Parryware make with CI/MS brackets, 32mm CP brass waste coupling of standard pattern C.P stop cock,C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (xiv) Flair 550 x 400(Cat. No.C0460, C0316, C8298) with short Pedestal, spring set and bolt set
76Providing fitting and fixing Mirror of Agmeco make ( Cat. No. VN-9011) colour CP frame of complete as directed and specified.(Size 500x400mm)
77Providing fitting and fixingglass shelf with C.P. guard railof Agmeco make to wall complete fixed with 25mm long screw, rawl plugetc.complete . (a) Econ(Cat.No.EN00104)
78Providing, fitting and fixingsoap dish of Sona make complete as specified and directed. (a) Stainless Steel Soap Dish Light
79Providing, fitting and fixingtowel rail of Sona make complete as specified and directed. (a) Chrome plated towel rail 300 mm long
80Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISIapproved including joining ,fitting and fixing wiyh clamps etc.as necessary completeat all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (ii) 110mm dia.
81Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approvedincluding joining, fitting and fixing etc.as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (ii) 110mm dia.
82Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (ii) 110mm dia.
83Supplying fiting and fixing PVCsingle tee with door of(Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (ii) 110mm dia.
84Supplying fiting and fixing PVCsingle ‘Y’ of (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (ii) 110mm dia.
85Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approvedincluding joining , fittingand fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C/R.C.C. and making good to the damages. (i) 110mm x110 mm
86Providing fitting and fixing 110mm dia. PVC cowel of ISI make completeas directed and specified.
87Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. ( ix ) 200 Users
88Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
89EXTERNAL WATER SUPPLY WORKS:Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container(container scaffolding tools etc. will have to be arranged by the contractor at his own cost).
90Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter
91Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (ii) pvc pipe (a) Supreme Brand. (vi) 140 mm diameter
92Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. (ii)PVC Pipe (a) Supreme Brand. (iii) 40mm Diameter
93Supplyingfitting and fixing ribbed screen PVC filter 3.00 metre long. (a) 40mm Diamter
94Supplyingfitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)
95Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
96Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (I) 2000 Lt capacity. (b)Polycon make
97Labour for erectingand placing PCVCTankover the stagging of 5.00m up to 8.00m complete as directed. (a) 2000 litre capacity
98Three phase Submersible motor pump set(Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guarsuitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump setcontrol panel. (2) 2 HP Three Phase(100mm Bore Well)
99(Boundary Wall ) CH-1: EARTHWORK:EARTHWORK IN EXCAVATION :Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
100Providing soling in foundation and under floor with stone/ (a).Brick on flat soling.
101PLAIN CEMENT CONCRETE WORKS: Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop 1cement: 4 sand :8 coarse aggregate by volume
102REINFORCED CEMENT CONCRETE WORKS :Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) . (I) Using Mixer Machine. (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser. a) M15 grade concrete or Prop. 1:2:4
103REINFORCED CEMENT CONCRETE WORKS (B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser. a) M15 grade concrete or Prop. 1:2:4
104REINFORCEMENT:Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) . a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL. b)Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc..
105REINFORCEMENT:Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling. c)ISI approved Mild steel reinforcement bar(M.S.Bar)
106Brick work in cement morter with 1st class brick including racking out jointsand curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary. (c) In proportion 1:5.
1071st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paidseparately). (A) 112mm thick brick wall. (b) In cement mortar in proportion 1:5. (1 cement:5 sand)
108PLASTERING:CEMENT PLASTERING:10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. d) In cement mortar 1:6
109CEMENT PAINT & PRIMER b) Finishing wall with water proofing cement paint of approvedbrand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
110TIMBER SHUTTERING (FORMWORK):Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in. Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank
111TIMBER SHUTTERING (FORMWORK):Providing form work of ordinary timber planking….Columns, Pillars, Posts & Strut. (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank
112Gate - 1No. (IRON GATE) : CH-1: EARTHWORK:EARTHWORK IN EXCAVATION:Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
113Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. (a).Brick on flat soling.
114PLAIN CEMENT CONCRETE WORKS :Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
115REINFORCED CEMENT CONCRETE WORKS:Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) . (I) Using Mixer Machine. (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser. a) M15 grade concrete or Prop. 1:2:4
116REINFORCED CEMENT CONCRETE WORKS:Providing and laying plain/reinforced cement croncrete works (B)In super structure from plinth level up to 1st floor level.ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.N) Without using admixture, plasticiser. a) M15 grade concrete or Prop. 1:2:4
117REINFORCEMENT:Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) . a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL. (i) TMT Corrosion resistant steel (CRS) reiforcement bar
118REINFORCEMENT:Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling.c)ISI approved Mild steel reinforcement bar(M.S.Bar)
119PLASTERING:CEMENT PLASTERING:10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises orrounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
120TIMBER SHUTTERING (FORMWORK):Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in. Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 38mm thick plank
121TIMBER SHUTTERING (FORMWORK):Providing form work of ordinary timber..Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (ii) Using 25mm thick plank
122PAINTING ON STEEL AND OTHER METAL SURFACE: Applying primary coat over new steel and other metal surface upto 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
123Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
124CHAPTER 17: FENCING & GATES: Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are tobe protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessarylocking arrangement on both faces, arrangement for temporary closing the gateand 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
125Internal Electrification:Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Short point up to 3.00 metre. length.
126Internal Electrification:Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core.. Medium point up to 6.00 metre. Length.
127Internal Electrification:Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core...Long point up to 10.00 metre. Length.
128Wiring for twin control light point with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 amp flush type 2 way switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Medium point up to 6.00 metre. Length.
129Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark withphenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Medium point up to 6.00 metre. Length.
130Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedconduit wiring system includingand fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switchboard (I.S.I. mark withphenolic laminated sheet cover earth continuity with 2.5 sq. mm cableto the 3rd pin of the socketas required complete with20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.). Medium point up to 6.00 metre. Length.
131Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan.
132Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVCconduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
133Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
134Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor.....With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
135Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor.....With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cablein 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
136Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessedPVC20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - IIIconduit.
137MCB/MCBDB: Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. . 12 way SPN double door
138Supplying with fitting and fixing sheet steel, phosphatised, powder painteddust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.(ABB, Schneider MG, legrand, Hager , Crabtree xpromake) .4 way TPN (4+12)double door
139Supplying with fitting and fixing SPN 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager , Crabtree xpro make). 6 to 32A
140Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager , Crabtree xpro make). 40A
141Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager,Crabtree xpromake). 63A
142MCCB:Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asianmake) . 63A
143MCCB:Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) ...125A
144LUMINARIES: Fitting and fixing of brackets on the wallin GI/ MS switch board (ISI marked) half conceal on wallwith phenolic laminated sheet cover with all accessories such as GI/ MS switch board (ISI marked) with phenolic laminated sheet cover including connection as approved by the Deptt.)as required complete.
145Supplying and fitting of 7/9 watt LED lamp in the existing batten holder/angle holder/ decorative bracket/bulk head fitting/pendent holder etc as specified and directed by the deptt.( as per present MRP)
146Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp
147Supplying and fixing of bulk head fitting suitable for CFL /LED lamp complete with all accessories including connection as approved by the Deptt.)as required. Without lamp.
148Supplying, fitting fixing ofLED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN 021C LED 20 S PSU CW GR S2
149Supplying,installation, testing and commissioning of pressure die cast power coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection with built in LED of following landscape luminaire ( POST TOP) suitable for 38 mm dia post top mounting applications including connection with 2.5sq.mm. 3 core PVC insulated round copper conductor as required and as diredted by the department. LIGHTING TECHNOLOGIES ADORNIS MIN MODEL NO.A04557LD00
150CALLBELL Supplying and fixing of Call bell ( Buzzer )including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required.
151CEILING/EXHAUST FAN: Supplying including fitting fixing of followingstar rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable,as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make). Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
152Supplying fiting and fixing of ceiling fan regulator including connections etc. complete as required. Electronic Type
153Supplying including fitting fixing of followingA.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic.Trans Air 300 mm sweep (Cromptonmake)
154EARTHING: Supply, installation & testing of Copper Plate earth station with600 mmx600 mmx3 mm copper earth plate withnecessary 40 mm dia. G.I. medium duty watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
155Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipewith necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mmhinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt
156Extra for using salt (5 Kand Charcoal (96 Kin G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
157Supplying & laying of25x4mmsize Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply ofBrass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
158Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
159Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
160PANEL: Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.25M X0.6MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation and brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 2nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 20mm X 3mm 4 strip copper Bus-Bar 0.5M length each. 2. Digital 3 Phase Voltmeter Accuracy class 0.5- 1 no. 3. Digital 3 Phase Ammeter Accuracy class 0.5- 1 no. 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no. 5. Voltmeter & Ammeter Selector Switch- 2 no. 6. 2 A Slide fuse unit - 3nos. (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
161External Electrification and Campus Lighting: Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to bemade to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security)and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 100 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
162Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular polemanufacturing out from electrically welded in 3 (threesection having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGRmake) . 410 SP 43 Length of pole = 10.00 metre., Length of sections,Bottom = 5.20 M, Middle = 2.40 M, Top = 2.40 M, Out side dia. & Thickness Bottom = 165.10 x 4.50 mm, Middle =138.70 x 4.50 mm, Top =114.3 x 3.65 mm
163Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
164Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
165Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly)set complete as required and as directed by the department.
166Supplying and erection of 11 KV Pin insulator (Poly)with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
167Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
168Supplying including installation of 4" dia. C.I. earth pipecomplete as required and as directed by the department.
169Supplying and erection of 11 KV Disc insulator (Poly)45 KN with hard ware fittings etc. as required and as directed by the department.
170Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
171Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
172Supplying & laying of 6 SWG G.I.. earth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
173xii) Supplying & laying of 8 SWG Copperearth drawn through 15 mm dia. Medium quality G.I. pipe from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
174xiii) Supplying and fitting fixing pole clamp complete as required and as directed by the department.
175Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988 armoured U.G. cableU.G. cable laid in ground/partially in air (as required for termination over groundincluding excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etto proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 3 & 1/2 Core A2XFY .25.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
176Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated….. 50.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
177Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV GSolid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated….. 95.00 Sq.mm.3 & 1/2 Core armoured U.G. cable
178Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1)1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch,through medium duty G.I. pipe(Tata/ Nezonemake or equivalent as approved by the Deptt)bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). Core - 3 & 1/2 A2XWY A2XFY. 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
179Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape.....50.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
180Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape..... 95.00 Sq.mm 3&1/2 Core U.G. cable in65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
181Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured, extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1)1988, laid in air or through existing cable trench/duct/ cable tray/ HDPE pipeincluding fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .Core - 2, 2XY. 4.00 Sq.mm 2 Core Unarmoured
182Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner …….6.00 Sq.mm 2 Core Unarmoured U.G. cable
183Supplying including installation of the Octagonal poles shall be designed to withstand themaximumwind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflectionof the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuouslytapered with single longitudinal welding. There shall not be any circumferentialwelding of the pole shaft. The welding of the pole shaft shall be done bySubmerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The baseplate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approvedby Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezonemake) . Pole Type BOP or equivalent-7030 Height7m The materials of the pole as follows : Conforming to grade S355JOConforming to grade S355JO , Base PlateFe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections :- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as perIS 2629 / IS 2633 / IS 4759 standards with averagecoating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate500 mm length at the elevation of 500 mm from thebase plate. The door shall be vandal resistance and shall be weather proof to ensure safety of insideconnection as .....Foundation:-The foundation shall be done with (Earth work:- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres.Steel :- 22.43 Kg.Shuttering :-4.32 square metres. = 22.43 Kg.
184Single arm bracket 1500mm long for 3m to 10 metre. Poles.
185Supplying including installation ,connection cable,as approved by the deptt with 2x205sqmm copper FR CABLE , testing and commissioning of the follpwing street light on existing pole/structure including lamp, driver, ballast as required complete as directed and specified by deptt. Philips lighting luminarie 36w Green Line Model BRP 409 LED CW 036 MR FG S1 PSU GR/BRP409 LED CE 033 NR PC 51 PSU GR or equivalent as approved by the Deptt.
186Supplying and installation of three phase (3-phase) energy Meter including testing fees (ASEB"s approved rate)
187Payment to be made to CAEDCL for Load and Meter security (Rate as per CAEDCL)
188Payment to be made to CAEDCL for Service Connection Charge
189Child friendly Element & BaLA Items
190Sanitary Napkin Incinerator Machine
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail