Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Under Ge ( I ) ( Dm ) Visakhapatnam Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Und, GE (I) (DM) VISAKHAPATNAM-Andhra Pradesh

Military Engineer Services-MES has published Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Under Ge ( I ) ( Dm ) Visakhapatnam Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Und. Submission Date for this Tender is 31-12-2021. Water Cooler Tenders in GE (I) (DM) VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30146993
Corrigendum : Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Under Ge ( I ) ( Dm ) Visakhapatnam Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Und
Open Tender
Indian
Andhra Pradesh
GE (I) (DM) VISAKHAPATNAM
31-12-2021

Tender Details

Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Under Ge ( I ) ( Dm ) Visakhapatnam Repair And Maintenance Of Various Capacity Water Coolers And Allied Works At Naval Dockyard Visakhapatnam Under Ge ( I ) ( Dm ) Visakhapatnam

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 36000.0 /-
Tender Value
INR 18 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINTENANCE OF VARIOUS CAPACITY WATER COOLERS AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
Sl. No. Item Description
1Material & labour for attending complaints of water coolers/ refrigerators/ deep freezers of any capacity by and checking of loose wiring/loose contacts and replacement of unserviceable spares such as capacitor, thermostat, over load protector, relay, fan motor, fan blade and MCBs etc.,and charging of gas wherever requiredand keeping the water cooler in trouble free conditioncomplete all as specified and directed. [Note:- (i) Spares such as capacitor, thermostat, over load protector, relay, fan motor, fan blade and MCBs etc., shall be measured and paid under relevant items of schedule "A" as supply only. (ii) Unit rate quoted shall be deemed to be included for replacement of burnt wires and wiring clips wherever required. (iii) Cost of gas shall be measured and paid separately as supply only]
2Material and labour for refrigerant gas charging of the coolers, thoroughly flushing out the refrigeration system, pressure testing with CO2/N2 gas, arresting of leakage, vacuumisation, supply regrigerant gas & charging the system conducting performance test complete all as specified and directed for thefollowing capacities. [Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.]
3150 ltrs
460/120 ltrs
540 / 80 ltrs
6All as per item No. 2.00above but Deep freezer / refrigerator of 165 ltrs to 300 ltrs capacity.
7Material and labour for servicingthe water cooler in position by cleaning the water cooler body, storage tank, fan bushes, blow out the condenser coils with air blower, alignment, greasing and arresting leakages, removing blockages of drain out-let connections, testing trouble free functioning complete all as specified and directed.
8Labour only for disconnecting all connections of the water coolers/ refrigerators/deep freezers from the existing location, transporting the same to workshop for carryout body repairs/ gas charging/ painting and transporting back the coolers/refrigerators/deep freezers to it’s original location, installing, connecting up, testing and commissioning all as specified and directed. [Note: (i) Body repairs/ painting shall be measured and paid under relevant items of schedule "A". (ii) Note : Cost of gas shall be measured and paid separately as supply only]
9Material and labour for cutting & removing all corroded/rusted portion of 40/60/150 ltrs capacity water coolers and making good the same with MS sheet and suitable size of MS angle as existing for the following parts including preparation ofsurfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. [Note : - Cost of MS sheet/MS angle iron shall be measured and paid separately as supply only.]
10Bottom legs (set of four)
11Bottomplate complete
12Base plate
13Body frame
14Top cover including replacement of hinges with rubber gasket
15Taking out defective PVC flexible connector, supply & fix heavy duty PVC flexible connector braided type 15mm dia and 450mm long union, nuts & washers on either end complete all as specified and directed. [Make :- Panna]
16Supply only starting / running capacitors of the following capacities [Make: Sarada/ power]
1715 Mfd
1840 Mfd to 60 Mfd
1925 Mfd
2010 Mfd
21Material and labour for preparing the surfaces smooth by scrapping/ chipping the corroded/rusted portions and applying one coat ofsynthetic enamel paint on inner and outer surface of the entire space of various types of water coolers , deep freezers and refrigerators of the following capacity complete all as specified and directed.
2240/80 ltrs, 60/120 ltrs
23150 ltrs
24165 - 300 ltrs
25Material and labour for taking out the defective sealed reciprocating / rotary compressors from the following capacities of water coolers and supply & fix new compressors and connecting the refregeration system after flushing out the system, leak testing with CO2, vaccumising and gas charging with refrigerent gas, testing and commissioning all as specified and directed.[Note : Cost of gas shall be measured and paid separately as supply only ] [Make : As per sample]
26150 ltrs capacity
2740/80 ltrs, 60/120 ltrs capacity
28Taking out the defective/unserviceable suction/ discharge/ charging copper tubes of water cooler and supply & fix new copper tubes of the following sizes including brazing and leak testing complete all as specified and directed.
293/8” dia
301/2 ” dia
315/16” dia
321/4 ” dia
33Taking out unserviceable condensers from the following capacity of water coolers and supply & fix new condenser alongwith suitable MS bed all as specified and directed.
3440/80 ltrs
3560/120 ltrs
36150 ltrs
37Supply & fix stop valve of fancy type chromium plated copper alloy 15mm bore with one GI union and GI nipple on the in-let connection of water cooler complete all as specified and directed. [Make :- Luster/Emerald/Kingston/Bright]
38Material and labour for taking out defective push / lift cock of water cooler, supply & fix new chromium plated brass self closing tap all as specified and directed. [Make :- Anchor/Emerald/Kingston]
39Material and labour for taking out defective float valve and supply & fix new brass ball valve of 15mm dia complete with polythene float and fly nutscrewed for iron pipe of brass ferrule all as specified and directed. [Make :- Viking/Hindon/Bright]
40Supply only FLORON 134a gas high cooling capacity, higher compressor life, ozone friendly, as AHRI 700 purity standards. Container Net Weight 450 grams [Make : SRF Ltd].
41Supply only fan motor of 1/35 HP capacity. [Make :- Frac Master/AUE/Signature]
42Supply only fan motor of 1/16 HP capacity. [Make :- Frac Master/AUE/Signature]
43Supply only fan motor of 1/32 HP capacity. [Make :- Frac Master/AUE/Signature]
44Supply only relay as existing make and model [Make :- Hitech/Usha/Aravind]
45Supply only Thermostat switch [Make: Indfos/ Voltas]
46Supply only fan blade of same as existing size and model.
47Supply only overload protector suitable for as existing size and model.
48Material and labour for taking out the corroded in-let and out-let pipe lines of water cooler and supply & fix new GI pipe line of medium grade, 15 mm bore conforming to IS-1239 part I complete with all fittings and specials such as elbows, bends, tees, unions etc, all as specified and directed. Make :- Oswal/Kalinga/Zindal /Tata]
49Taking out the perished PVC flexible drain pipes from water cooler and supply & fix new PVC flexible drain pipe of size 25mm dia all as specified and directed
50Supply and fixing SS water storage tank 80 ltr cap with cooling coilas existing size and taking out old unserviceable one all as specified and directed
51Supply and fixing of drain tray made stain less steel as existing sizes and taking out old unserviceable one all as specified and directed.
52Supply only MS angle iron / MS sheet with same guage of suitable size as per site requirement
53M&L for dismantling unserviceable voltage stabiliser for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, vernishing and testing after repair complete for capacity upto 2 KVA as per existing make complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail