Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair, GE Haddo Port Blair-Andaman And Nicobar Islands

Military Engineer Services-MES has published Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair. Submission Date for this Tender is 23-12-2021. Pump House Construction Tenders in GE Haddo Port Blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

30146800
Corrigendum : Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
GE Haddo Port Blair
23-12-2021

Tender Details

Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair Special Repairs To Ug Sump And Pump House At Buniyadabad And Other Sanctioned Works Under Ge Haddo, Port Blair

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Dec-2021 BOQ Corrigendum BOQ 23-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 54000.0 /-
Tender Value
INR 27 Lakhs /-

BOQ Items

NAME OF WORK : SPECIAL REPAIRS TO UG SUMP AND PUMP HOUSE AT BUNIYADABAD AND OTHER SANCTIONED WORKS UNDER GE HADDO, PORT BLAIR
Sl. No. Item Description
1Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
2Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
3M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
4M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate)as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
5M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
6M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
7M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc., also splays between floors and beams etc., for rough finished surfaces of concrete flat complete all as specified and as directed.
8Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
9M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
10M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry not exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
11Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
12M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed withintegral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
13M&L for rendering 15mm thick in CM (1:4) mixed withintegral water proofing compound @ 3% by weight of cement on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
14M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
15M&L for applying bonding agent on old concrete surfaces (wall & ceiling) all as specified and as per manufacturers instructions, Over prepared surfaces provide 20mm thick high build polymer modified cement sand mortar (1:3) mixed with 10 litres (minimum) Nitobond SBR per 50 kilograms of cement of M/sFOSROC Chemical (India ) Pvt Ltd or equivalent in Dr. Fixit or Harjas Coatings & Polymers includingnecessary scaffolding up to 15 m and including match the existing shade of surface complete all as specified and directed
16Supply only integral water proofing compound.
17M&L for applying 2 to 3mm thick wall care putty on wall surfaces complete all as specified and as directed
18M&L for preparation of new plastered surfaces of walls and applying two coats of aqua based anti fungal paint overa a coat of primer complete all as specified and as directed.
19M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of distemper oil emulsion over a coat of primer after filling the cracks with filler complete all as specified and as directed.
20M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer after levelling the undulations if any with cement putty complete all as specified and as directed.
21M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
22M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment by scraping, washing, cleaning etc., and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer after filling the cracks with filler complete all as specified and as directed.
23Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc.,laid bedded and pointed in any mortar mortar complete all as specified and as directed.
24Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
25M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc,laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
26M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc,laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
27M&L for glazed ceramic designed coloured tilesin vertical surfaces using size of tiles 200x200x7mm / 350x250x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
28M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
29Dismantling of wrought iron or mild steel work and structural steel work of any description ot otherwise provided for complete.
30M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality "B" complete all as specified and as directed.
31M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, framing for cladding and glazing, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Grade E-250) Quality "A" complete all as specified and as directed.
32M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Grade E-165 complete all as specified and as directed.
33S&F Expanded metal, cut to length, bent to required shape and tying with and including annealed mild steel wire not less than 0.9mm dia or fixingwith galvanised steel staples supplied and fixed to wool or steel members complete all as specified and as directed
34M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed.
35M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
36Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
37S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
38S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
39S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
40Dismantling timber scantlings 40 sq. cm and over in section,from framed work in any position
41Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
42S&F 19mm thick plywood boarding, grade BWR, type BBas in eaves/barge boards fixed with screws on flat iron/timber frame work support including applying two coats of syntetic enamel paint complete all as specified and as directed.
43Dismantling ceiling boards / wall cladding (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and grid complete all as specified and as directed.
44M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
45M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., including 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screwscomplete all as specified and as directed.
46Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed.
47Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
48S&F Second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including preservative treatment complete all as specified and as directed.
49S&F 35mm thick second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, fixed to chowkats complete all as specified and as directed.
50S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fixed to chowkats complete all as specified and as directed.
51M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
52Supply and fix in repairs stainless steelIMAX Hinges for aluminium window shutter
53Supply only 4.0 mm thick plain sheet glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
54Supply only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
55S&F 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
56S&F 18/19mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
57S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening complete all as specified and as directed.
58S&F factory made solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm plain colour PVC sheet on back face as per specification & drawing fixed to door frame complete all as specified and as directed.
59S&F in repairs 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed.
60S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
61S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
62S&F sliding door bolt, 250mm long, aluminium alloy, anodised,with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
63S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps 40mm (when open) complete all as specified and as directed.
64S&F 50mm dia, polished, hard wood knobs fixed with screws complete all as specified
65S&F door closer, aluminium (extruded section body), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, fixed in repairs with screws complete all as specified and as directed.
66S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length pipes single socketed, in any length with rubber ring joints, laid in trenches/fixed to walls/placed in weep holes using synthetic rubber adhesive cement solvent complete all as specified and as directed.
67S&F PVC (SWR) bends any radius, diameter of outlet 110 mm complete all as specified and as directed.
68S&F PVC (SWR) branch piece, (Single Y) equal or unequal, diameter of outlet 110 mm complete all as specified and as directed.
69S&F PVC (SWR) multi floor trap with grating including jointing with solvent cement, diameterof outlet 75 mm complete all as specified and as directed.
70S&F PVC (SWR) "P" or"S" floor trap 100mm outlet dia with grating including jointing with solvent cement complete all as specified and as directed.
71M&L for vitreous China wash hand basin, white, flat back, size 550mm x 400mm including cutting for and pinning in ends of brackets or erecting stand, 32mm dia waste coupling brass chromium plated, bottle trap 32mm bore brass chromium plated with necessary packing union and caps, chain and plug, PVC connections 15mm size with PTMT nuts of length 450mm, screwed down for iron pipe or for unions complete all as specified and as directed.
72M&L for vitreous China squatting pan, ‘Orissa’ pattern,size 580 x 440 mm white, with integral foot rests, P or S trap including provision of lime concrete bedding with and includingflush pipe of polyethylene of low or high density or PVC 32 mm dia, PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
73M&L for vitreous China, wash down water closet EWC (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed.
74S&F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litre capacity, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
75S&F in repairs vitreous China bowl urinal with top inlet, half stall type coloured complete fixing with suitable fixing arrangements to wall with and including cp urinal spreader, cp domed 32mm bore dia waste coupling and waste pipe complete all as specified and as directed
76S&F pillar tap, brass, 15mm dia, chromium plated, fancy type with capstan heads, screwed down, high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
77S&F bib tap, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed.
78S&F angular stop cock, 15mm dia, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, with long shank and cup (concealed type) screwed down, screwed both ends for iron pipe or for unions complete all as specified and as directed.
79S&F tubular towel rail, brass, chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. AQN-7711 or equivalent in PARRYWARE/ PRAYAG/ JOHNSON
80S&F health faucet, brass, chromium plated with 8mm dia, 1.0 m long flexible tube, screwed for iron pipe or for brass ferrule 15mm dia or bore complete all as specified and as directed. MAKE: PRAYAG Cat part No. BEA-41 or equivalent in PARRYWARE/ ZOLOTO/ JOHNSON
81M&L for PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and as directed.
82S&F CP grating 125mm dia round with or without waste hole fixed on floor/ nahani trap fixed with white cement complete all as specifed and as directed
83S&F 600mm x 450mm bevelled edge mirror of selected quality glass 6mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
84M&L for Cutting chases in PCC block masonry walls,for shelves, lintels, edges of landing etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed.
85Taking up or down 15mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
86Taking up or down 20mm dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
87S&F 20mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
88S&F 25mm bore CPVC pipes SDR 13.5 & Plain CPVC SDR 11fittings fittings, fixed complete to walls, ceilings or in floors etc., (including concealing, if required) and to any type of pipe complete all as specified and as directed.
89Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc;removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
90Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
91Taking down existing unserviceable main switches/ distribution boards of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
92Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
93M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE LIGHT/FAN point controlled by one, one way6 Amps switch.
94M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
95M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
96M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps switch on independent board.
97S&F switch piano, flush type, single pole, one way, 6 Amps, 240 volts complete all as specified and as directed.
98S&F switch piano, flush type, single pole, one way, 16 Amps, 240 volts complete all as specified and as directed.
99S&F socket outlet 2 in 1, 3 pin 6 Amps, flush type, universal all as specified and as directed.
100S&F socket outlet 2 in 1, 3 pin 16 Amps, flush type, universal all as specified and as directed.
101S&F electronic fan regulator for ceiling fan, step type, 5 speed, AC, 120 watts, 230 volts complete all as specified and as directed.
102M&L for ceiling rose,three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
103M&L for Sub main wiring complete with two runs (1P+1N) of4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
104Taking down carefully ceiling fan of any sweep from ceiling hook at any height after disconnecting from electricity, dismantling blades, opening upfor carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade and writing MES No. in synthetic enamel paint, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed. NOTE: Spare parts like ball bearings, shafts, fan blades, copper winding shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY. A book shall be maintained for record of servicing and replacement of spares with MES Nos. of fans.
105Rewinding of ceiling fan (any sweep) stator by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves. lead wires and testing after assembling in position in ceiling fan complete all as specified and as directed.
106SUPPLY ONLY sealed ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed.
107SUPPLY ONLY shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed.
108S&F ceilingfan blade set for 1200mm sweep complete all as specified and as directed.
109S&F Tube light fittings LED 20 watts 4 feetincluding all accessories and fixing arrangements complete all as specified anddirected Make :CG Cat Part No : CCS-100-20-65-HL2-DP-NWH/ Philips Cat Part No : Astra line plus/C&S/Havells
110S&F LED security light fitting, 1x25 watts, 230 volts, 50Hz Ac supply, with high power and high efficiency long life LEDs with built-in electronic driver, unique peanut lens to ensure uniform distribution completely housed, complete all as specified and as directed. MAKE:CROMPTON Cat Part No. LSTS-25-CDL-M or its equivalent in Philips/ Havells
111S&F surface mounted 10watts LED , 2 feet including all accessories and fixing arrangement complete all as specifie and as directed MAKE: Philips Cat No : BN021CLED 10S-6500 PSU GR S1 or equivalent in Crompton/ Havells
112S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-54 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed. MAKE:INDO ASIAN Cat part No. 811826 or equivalent in L&T/ LEGRAND/ HAVELLS
113S&F MCB, SPN, 230 volts, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE:INDO ASIAN /L&T/ LEGRAND/ ABB/ HAVELLS
114S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps,10 KA rupturing capacity complete all as specified and as directed. MAKE:INDO ASIAN Cat part No. 811122 to 811129 or equivalent in L&T/ LEGRAND/ ABB/ HAVELLS
115Taking down old corroded GI bracket and supply and fixing new mounting bracket made up of 25mm dia galvanised steel tubing, medium grade, 1.20 metres long, bent to shape with inner angle not less than 120°, with and including necessary fixing clamps fabricated out of angle iron/flat iron of suitable size, bolts, nuts and washers as required and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
116M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steelall as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mmc/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail