Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manauri Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manau, Manauri,Prayagraj-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manauri Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manau. Submission Date for this Tender is 25-12-2021. LED Light Tenders in Manauri,Prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30146796
Corrigendum : Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manauri Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manau
Open Tender
Indian
Uttar Pradesh
Manauri,Prayagraj
25-12-2021

Tender Details

Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manauri Repair / Maintenance Of Street And Perimeter Light With Allied Works In Domestic / Md Accn Area / Aor Under Age ( I ) Manauri

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 9.90 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF STREET AND PERIMETER LIGHT WITH ALLIED WORKS IN DOMESTIC/ MD ACCN AREA/ AOR UNDER AGE(I) MANAURI
Sl. No. Item Description
1Excavatingin trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundationetc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm thick in soft/loose soil.
3Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point.
4M&L for Sand cushioning in trenches with clean dry unsheathed gently punning around cable for protection complete. Note : Only punned thickness shall be measured for payment
5M&L for brick, old sub class "B" well burnt, laid dry flat in trenches for protection of cable over LT cable, complete all as specified and directed.
6Cutting /boringto pilinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 MM dia of bore for drawn through XLPE under ground cable forgivingmechanical protection to cable complete all as directed. Note ;Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per exisiting.
7Supply and fixing galvainesd water tubing light grade 40 mm dia of borefixed with pole/ surface of wall / laid in trench etc assiteusing 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make: Jindal / Tata / Swastic
8Supply, laying, jointing & testing of underground LT cables XLPE insulated armoured heavy duty aluminium conductor power cable1100 Volt gradecross-sectional area 10 Sqmm 2 core (earthed) laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs including taking out of old cable. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
9All as per item No 8 above but 25 Sqmm 4 core (earthed)
10All as per item No 8 above but 35 Sqmm 3.5 core (earthed)
11Supply and fixing in replacement of 45 watt LED street light fitting energy savingIP 65 protection includingmaking electric connection using three core copper flexible cable drawn through in PVC flexible conduit and GI bracket made out from GI pipe light grade in 1.2 Mtr long bend in 120° with clamps made out from GI strip 32x4mm in 2 Nos , nuts, bolts & washers etc complete all as specified and directed. Note :- (i) Fitting shall be of Make :Bajaj cat No ENXT P 45L WW CR PC SD (EDGENXT LED) or Crompton cat Part No TRP-409-45-57-SL-NS-GL-NSG or equivalent model of make philips/ Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
12Supply and fixing in replacement of 60 watt LED street light fitting energy savingIP 65 protection includingmaking electric connection using three core copper flexible cable drawn through in PVC flexible conduit and GI bracket made out from GI pipe light grade in 1.2 Mtr long bend in 120° with clamps made out from GI strip 32x4mm in 2 Nos , nuts, bolts & washers etc complete all as specified and directed. Note :- (i) Fitting shall be of Make :Bajaj cat No ENXT P 60L WW CR PC SD (EDGENXT LED) or Crompton cat Part No TRP-409-60-57-SL-GL-NSG or equivalent model of make philips/ Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
13Supply and fixed in replacement of flood light fitting LED minimum 200 W equipped with IP66 protectionto be fix on pole/ wall etc all as site making all connection using suitable three core flexible copper cable drawn through in flexible conduit pipe from control box to light fittings complete all as directed. Note :- (i) Fitting shall be of Make :Bajaj cat No BJFL 200W LED I (AMAZE LED) or Crompton cat Part No LFLN-200-CDL/60-M (PLUTO NEO) or equivalent model of make philips/ Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB to fitting shall be included in unit rate quoted by contractor.
14S&Fin replacement of shock proof, fire retardant rust proof, out door pole kiosk controllbox of size 310 x 210 x120 mm made out of one piece Engineer plastic moulding of siemens grey colour comprising4 Nos aluminium bus bar 200Amp rating fitted on DMC unbrakable insulator andincluding clamps for fixing arrangement complete all as specified and directed. Make:Sintex /Universal/ SMC/HENSEL
15Labour only with necessary T&P such as tool kit/ ladder to attend day to day security light/Flood light related works and rapair/replace the unsv spares such as driver control plate/Fuse assembly/ cable from fittings to junction box/GI Pipe bracket/clamps/kiosk box all other required work for making servicable to security light fittings etc all as specified. Note : (i) Required spares such as driver shall be measured agaist respective item of this Sch as supply only. (ii) Old drivers shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (iii) Making serviceable one security light will be considered as single job.
16Supply only Driver circuit plate for LED security light fitting capacity 45 W to 60 W in original suitable for make/ model suggested by deppt complete. Make :As per sample at site.
17Supply only Driver circuit plate for LED security light fitting capacity 100 W to 120 W in original suitable for make/ model suggested by deppt complete. Make :As per sample at site.
18Supply only Driver circuit plate for LED security light fitting capacity 150 W to 200 W in original suitable for make/ model suggested by deppt complete. Make :As per sample at site.
19Supply & fixed in replacement threecore copper flexible cable , PVC insulated sheathed heavy duty in size 1.0 Sqmm drawn through in PVC flexible conduit for making inter connection from control box to existing light fittigs complete allas directed. Make :Finolex / Legrand / Havells
20All as per item No 19 above but three core 1.5 sqmm.
21Supply and fix in replacement three polepower contactor type ML-4 suitable for 70-100 Amp range, 240 volt including making connection complete as specified and directed. Make : L&TModel-SS90910or equivelent in Seimens/ Schneider/C&S
22Supply and fix in replacement three polepower contactor type MNX suitable for 32-55 Amp range, 230 /415 volt including 1 no with NO volt coil, making connection complete as specified and directed. Make :L&T Model-CS94111or equivelent in Seimens/ Schneider/C&S
23Supply and fix inreplacement three polepower contactor type MNX suitable for9-25 Amp range, 230/415 volt including one 1 with NO volt coil, making connection complete as specified and directed Make :L&T Model-CS94106or equivelent in Seimens/ Schneider/ C&S
24S&F in replacement timer switch (FM series) suitable for 16A/250 V AC supply, FM/1 quartz daily 240V AC base/din mounting including making connection complete all as specified and as directed. Make :L&T Model- J648B1 or equivelent in Seimens/ Schneider/ C&S
25S&F in replacement for security light bracket made out by GI pipe light grade in suitable dia of bore upto 40 mm in 1.2 Mtr long and bend in 120 digree bracing fixed with 02 Nos clamp made out by Mild steel strip 25x4 mm with nut bolts and washers. Note:- MS clamps shall be painted with two coat of aluminium paint over a coat of redoxide primer.
26M&L for servicing , cleaning, oiling greasing etc to all required site work to make smoothly to intergral power toolHigh Mask light tower/ pole operating SWG wire made cable, rolling pully, controling gear, pinoinincluding repairing to control box / panel circuit etc after removing / taking out from existing location and re-assemblingin any length / specification etcall completeasand directed. Note : Quoted rate shall be included cost of required minor spare such as nut bolt, washer, motor pully, support bracket etc to all as site.
27Supply and fixing in replacement to SWG wire made flexibale cable india of boreas per exisiting ( more than 12 mm) for repacing tounsv cable of high mask light fitting in any length/ specification, incl lowering taking down re-assembling oiling , greasing replacing to minor spare such as pully, penion, brackets, nut bolt washer oprating motor mounting bolt etc to all make serviceable as site complete and directed.
28Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri if not specified in BOQ
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail