Work Of Maintenance Of Ht / Lt / 33 Kv Lines In The Area Of Eudsd Iind Etah Under Eudd Etah., Etah-Uttar Pradesh

Dakshinanchal Vidyut Vitran Nigam Limited-DVVNL has published Work Of Maintenance Of Ht / Lt / 33 Kv Lines In The Area Of Eudsd Iind Etah Under Eudd Etah.. Submission Date for this Tender is 09-12-2021. Overhead Line Tenders in Etah Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30142454
Work Of Maintenance Of Ht / Lt / 33 Kv Lines In The Area Of Eudsd Iind Etah Under Eudd Etah.
Open Tender
Indian
Uttar Pradesh
Etah
09-12-2021

Tender Details

Work Of Maintenance Of Ht / Lt / 33 Kv Lines In The Area Of Eudsd Iind Etah Under Eudd Etah.

Key Value

Document Fees
INR 1180 /-
EMD
INR 2000.0 /-
Tender Value
INR 2 Lakhs /-

BOQ Items

Name of Work:Work of Maintenance of HT/LT/33 KV lines in the area of EUDSD IInd Etah under EUDD Etah.
Sl. No. Item Description
1Safe carriage of 8.5/9 mtr. long PCC pole from store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends.
2Safe carriage of11/13 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends.
3Safe carriage of9 mtr STPfrom store center Etah/nearest 33/11 KV S/S to direct pit site in distance range 0 to 60 Km. including loading & unloading at both ends.
4Safe carriage of line material from store center Etah/nearest substation to pit site in distance range 0 to 60 Km. including loading & unloading at both ends.
5Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place.
61- Dog/ Raccoon/ Rabbit conductor
72- AAAC/ACSR weasel conductor/ GI wire.
83- ABC 3X95+1X35+1X16/3X50
94- ABC 3X120+1X70+1X16
10Errection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes
11Errection of 9 mtr. STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes
12Errection of 11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes
13Errection of 8.5 mtr. long PCC poles as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete.
14Errection of 11mtr. STP as Double Pole/ section pole including drilling,cutting etc. andfixing of all accessories etc. complete.
15Laying stringing & sagging of 3 phase 3 wire 33/HT/LT line with ACSR/ weasel/ Reccoon/Dog conductor including binding and nuzzling etc. complete.
161- Dog/ Raccoon/ Rabbit conductor
172- AAAC/ACSR weasel conductor/ GI wire.
183- ABC 3X95+1X35+1X16/3X50
194- ABC 3X120+1X70+1X16
20Straighting of tilted PCC poles/ST P/Railsingle support of HT/LT line after opening of nuzzling, digging of pit applying anti direction force for making of proper alignment of line.
21Straighting of tilted D/P after opening of connection applying anti direction force, digging of dug for proper alignment of line including reconnection etc. complete.
22Opening of HT/LT connections & lowering of followingT/F from D/P/Plinth and shifting up to in safer place.
231- 25/63 KVA T/F
241- 100 KVA T/F
25Dismanteling of old/damage STP/RS Joistof HT/LT line andcarriage to store centre Etah
26Re-sagging of loose 33/HT/LT conductor after opening, binding, nozzling etc.
271- Dog/ Raccoon/ Rabbit conductor
282- AAAC/ACSR weasel conductor/ GI wire.
293- ABC 3X120+1X70+1X16
304-ABC 3X95+1X35+1X16
315-ABC 3X50+1X35+1X16
32Replacement of following broken/damaged/missing accessories by new accessories including opening of the same and refixing.
331-11 KV cross arms V type
342-11 KV pin insulator
353-11 KV pin with nut
364-11 KV Disc insulator
375-Cross Arms holding clamps
386-F Clamps
397-LT shackle insulator
408-33 KV cross arm.
419-33 KV pin with nut
4210-33 KV pin insulator
43Retightening of Stay rod. Etc. complete.
44Providingfixing of stay rod with nuzzling etc. complete.
45Earthing of PCC/RS Joist/STP as per RESPO norms.
46Carriage of old material from pit site to JE store/store center, Etah in distance range 0 to 10 km including loading & unloading and proper stacking.
47Mounting of Following Transformers on double pole/Plinth including making of the connection etc complete.
481- 25/63 KVA T/F
491- 100 KVA T/F
50Chopping of tree branches
51Disconnecting of LT service line of following category of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of clamp/connectors etc. for consumer service cables after commissioning ofline.
52Single phase consumer
53Three phase consumer
54Repairing/ Resagging / new guarding of HT lines with GI wire as per RESPO norms
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail