University Of Delhi-DU has published Civil And Interior Works For Audio Video Room At Janki Devi Memorial College, New Delhi 110060.. Submission Date for this Tender is 16-12-2021. Civil Work Tenders in Principal Janki Devi Memorial College Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | RECORDING STUDIO |
2 | Half brick masonry with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
3 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
4 | 9" Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
5 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering: 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
6 | Providing and fixing melamine polished wooden door Chowkhats with Aluminium subframe. Polish Finished wood section size of 6” x 2.5” of Second-class teak wood fixed over aluminium subframe section of 25 mm x 75 mm x 3 mm. Work including all labour, material, hardware, HILTI PVC dash-fastener (16 per door- 8 for subframe and 8 for door) and fixing COMPLETE. Contractor will fix the aluminium subframe to the door opening in the brick wall before doing the plaster work. After the plasterwork is completed, the contractor will fix the wooden frame on top of the aluminium subframe. Thereafter, the contractor will do melamine polish on the door Chowkhats complete as per the instructions of the engineer in charge. |
7 | ACOUSTIC DOOR: Providing, Supplying, Installation, Testing and fixing in position a 65 mm thick acoustic door. Door should have a 150 mm x 300 mm vision panel of 6.0 mm thick toughened glass. Shutter shall be made with 100 mm x 50 mm thick hardwood outer frame with 50 mm x 50 mm hardwood ribs at 500 mm c/c both ways. All woodwork shall be treated with anti-termite treatment. The door shutter shall have 6 mm thick BWP grade plywood fixed on its both sides. All the cavities inside the door shall be filled with high NRC acoustic insulation materials (rockwool of 60 kg/m3 density) Insides of the door will be lined with 3 mm thick MLV Sheet of minimum 1700 kg/m3 density. Periphery of the the shutter shall be covered with 12 mm thick teakwood lipping matching with the door frame. The external faces of the door shutter will be finished with 1mm thick laminate on both sides. Teakwood lipping will be melamine polished. Weather seal of Rehau make shall be fixed on the door frame to fill the gap of shutter and wooden frame. Drop down seal to be fixed in shutter to block the gap with floor when the door is closed. The cost shall include all hardware fittings like heavy duty SS Hinges (4 inch long - 5 per door), 1 ft long D type SS Handles of Godrej/Hettich/Dorma make (both inside and outside) and door Lock of Godrej/Hettich/Dorma make. |
8 | Providing and fixing bright finished Heavy duty SS AL drop with necessary SS screws etc. complete: 300 x 16 x 5 mm |
9 | Providing and fixing 40-80 KG capacity Hydraulic door closer of Godrej/Hettich/Dorset or Dorma. |
10 | Providing and fixing approx. 1m x 1m double glazed hermetically sealed glazing with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge. The glazing will be fixed inside Aluminium U channel of appropriate section size. Cost shall be inclusive of providing fixing glass and U channel complete. |
11 | Filling the gap in between aluminium/wooden frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
12 | Providing and fixing tiled false ceiling as per DSR 2021 item no.12.52.4 -complete with 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595 x 595 mm, having perforation of 9.7 x 9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non-woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. Contractor shall take approval of sample from Architect/Engineer incharge before procurement of materials. |
13 | 12/15 mm cement plaster of mix (Junctions of all RCC and brick shall be provided with chicken wire mesh of 150 mm width on either side of the junction before plastering)1:3:3 (1 cement: 3 course sand: 3 fine sand) |
14 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. (Asian/ ICI /Shalimar/ Berger/ Nerolac) |
15 | Providing & Fixing 3 mm thick LG PVC TILE flooring GRD 1110 as per manufacturers specifications after cleaning/ scrapping & removing of dust particles from the surface and applying air blower to dry the surface. The scope of work shall also include application of hand roller to ensure zero entrapped air beneath PVC flooring. |
16 | Acoustical Wall Panels with Gripper system:Providing and installing Acoustical treatment to the walls, including 50mmX50mmX2mm Aluminium section framework of size 600mm x 600mm and 50 mm thick Acoustical Insulation of 1000 gsm density from Star Insulation or Prime Insulation. 9 mm thick Plywood strips-100 mm width strips with 20 mm air gaps in between, fixed over acoustical insulation. The plywood strips are to be faced with 6 mm thk fire retardant polyester wadding and gripper system from Walltracts, Chisel Interiors Inter Dimension or equivalent system) pressure stapled over Plywood strips and selected FINAL Fabric . Fabric is to be approved by Client and tested by vendor for dimensional stability etc installed in the gripper system, all done in accordance to the recommendation and the specs Rate quoted includes all the materials, labour, scaffolding, lead, lift, finishing, cleaning, hardware, etc complete. Contractor shall take approval of samples and the Shop drawings from architect/engineer in charge prior to the commencement of the work. |
17 | 1 TR Hi-wall Split Unit (5 Star Rated Inverter AC) Supply, installation, testing and commissioning of Hi-wall Split Unit with rotary compressor & cordless control including 1) Outdoor unit stand/ wall mount/ceiling suspension 2) Power & control cabling. (FRLS 4 Core 4 Sq.mm. wire in FRLS Conduit) 3) MCB’s. 20 AMP 4) Voltage Stabilizer (140V to 280V) Copper wounded:4 KVA ( Servo mate, Bluebird orVGuard make ) 5) Refrigerant Piping duly insulated with 13 mm for indoor application and 19 mm for outdoor application closed cell nitrile rubber of density 60+/-10% Kg/m3 to interconnect indoor & outdoor units for each circuit. Up to 3 meters per unit. 6) 25 mm dia UPVC Condensate Drain Water piping of density 20 kg/m3 complete with fittings like elbows, tees, reducers, bends, support and 13mm thick insulation. (Upto 15 meter per unit) 7) Anti-Corrosion Coating on coils. 8) Core Cutting in the Brick Wall for making required opening for copper pipe / condensate pipe.(MITSUBISHI/DAIKIN/FIJITSU O GENERAL ONLY) |
18 | LED light fitting, 2ft x 2ft LED Panel light of philips, Havells or equivalent make complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. |
19 | Wiring for the following light points with 1.5sq.mmPVCinsulatedcopperconductor 1100 volts gradestrandedflexible FRLS wires of approvedmake in concealedor surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6mmthickGIboxandearthingof fixturesandthe outlet boxwith1.5 sq.mmPVCinsulatedcopperconductorstranded flexible "FRLS" wire. |
20 | Wiring for 250 volts single phase and neutral 16 amps modularswitch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade strandedflexible "FRLS" wire in concealed or surface mounted25 mm dia 16 gauge MS conduit / existing raceway including providingand fixing of 16 amps 3 pin modular switchedsockets of approvedmake and design in 1.6 mm thick GI box withgrid plates and earthing the third pin ofeachsocket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. (No loop point allowed) |
21 | Wiringfor 250 volts singlephaseand neutral6 amps modular switch socketoutletwith universal pinswith3x2.5sq.mmPVC insulated copper conductor 1100 volts grade strandedflexible "FRLS" wire in concealed orsurfacemounted25 mm dia 16 gaugeMSconduit / existing raceway including providingand fixing of 6/16 amps3pinmodularswitchedsockets of approvedmake and designin1.6 mm thick GI box withgridplatesandearthing the thirdpinofeachsocketoutletwith2.5Sq mm PVCinsulated copperconductorstrandedflexible "FRLS" wire. (No loop point allowed) |
22 | Providing and fixing in position the following 2mm thick PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design. 20 mm dia PVC conduit |
23 | DISTRIBUTION BOARDS: Supply, installation, testing and commissioning ofthe following cubicletype1.6mmthickCRCA sheet steel enclosed and partitions to segregate phases recessed inwallor surfacemounted finaldistributionboardsofthe following description.Distribution board shall be powder coated and double door construction and in four tier configuration.8 way TPN DB with 12 No 10/16/20/32 amps SP MCB as outgoing and 3 No. 32 amps DP RCCB’sof 100 mA leakage current including1 No. 16 amps 4 Pole MCB as incomer & separate neutral link for each phase and earth bar. |
24 | EARTHING INSTALLATION: Supplying, fixing, testing and commissioning of following bare Copper/GI tapes including all necessary fixing accessories and effecting connections. 8 SWG GI wire |
25 | Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300 mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required. |