Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme , , Maithon, Jharkhand-Jharkhand

Damodar Valley Corporation has published Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme , . Submission Date for this Tender is 03-02-2022. Transformer Supply Tenders in Maithon, Jharkhand Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

30126102
Corrigendum : Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme ,
Open Tender
Indian
Jharkhand
Maithon, Jharkhand
03-02-2022

Tender Details

Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme Procurement For Current Transformer ( 132Kv ) And Potential Transformer ( 132Kv ) For Implementation Of Sema Ph-Ii Scheme , 132 Kv Ct -- ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) As Per Technical Specification. , 132 Kv Ct --Short Time Current Test ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) , 132 Kv Ct --Temperature Rise Test ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) , 132 Kv Ct --Lightning Impulse Test ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) , 132 Kv Ct -- High Voltage Power Frequency Wet Withstand Voltage Test ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) , 132 Kv Ct -- Determination Of Errors And Other Characteristics Specific To A Particular Accuracy Class ( Ratio : 2000 / 5, 800-400 / 5-5-5-5 ) , 132 Kv Ct -- ( Ratio : 1600-800 / 1-1-1-1 ) As Per Technical Specification. , 132 Kv Ct --Short Time Current Test ( Ratio : 1600-800 / 1-1-1-1 ) , 132 Kv Ct --Temperature Rise Test ( Ratio : 1600-800 / 1-1-1-1 ) , 132 Kv Ct --Lightning Impulse Test ( Ratio : 1600- 800 / 1-1-1-1 ) , 132 Kv Ct --High Voltage Power Frequency Wet Withstand Voltage Test ( Ratio : 1600-800 / 1-1-1-1 ) , 132 Kv Ct -- Determination Of Errors And Other Characteristics Specific To A Particular Accuracy Class ( Ratio :1600-800 / 1-1-1-1 ) , 132 Kv Pt -- 132Kv / V3  /  110V / V3 /  110V / V3 /  110V / V3 ( 3P-3P-0.2 ) ) As Per Technical Specification. , 132 Kv Pt --Temperature Rise Test , 132 Kv Pt --Lightning Impulse Voltage Test , 132 Kv Pt -- Short Circuit Withstand Capacity Test , 132 Kv Pt -- High Voltage Power Frequency Wet Withstand Voltage Test , 132 Kv Pt -- Accuracy Test

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Dec-2021 Corrigendum_No_1 Technical Bid 30-12-2021
2 30-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-01-2022
3 14-Jan-2022 Corrigendum_No_2 Date 27-01-2022
4 25-Jan-2022 Corrigendum_No_3 Date 03-02-2022

Key Value

Document Fees
INR 7000 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Procurement for Current Transformer (132KV) & Potential Transformer (132KV) for implementation of SEMA PH-II scheme.
Sl. No. Item Description
1132 KV CT -- (Ratio : 2000/5, 800-400 /5-5-5-5) as per technical specification.
2132 KV CT --Short time current test (Ratio : 2000/5, 800-400 /5-5-5-5)
3132 KV CT --Temperature Rise test (Ratio : 2000/5, 800-400 /5-5-5-5)
4132 KV CT --Lightning Impulse test (Ratio : 2000/5, 800-400 /5-5-5-5)
5132 KV CT -- High voltage power frequency wet withstand voltage test (Ratio : 2000/5, 800-400 /5-5-5-5)
6132 KV CT -- Determination of errors and other characteristics specific to a particular accuracy class (Ratio : 2000/5, 800-400 /5-5-5-5)
7132 KV CT -- (Ratio : 1600-800/1-1-1-1)as per technical specification.
8132 KV CT --Short time current test (Ratio : 1600-800/1-1-1-1)
9132 KV CT --Temperature Rise test (Ratio : 1600-800/1-1-1-1)
10132 KV CT --Lightning Impulse test (Ratio : 1600- 800/1-1-1-1)
11132 KV CT --High voltage power frequency wet withstand voltage test (Ratio : 1600-800/1-1-1-1)
12132 KV CT -- Determination of errors and other characteristics specific to a particular accuracy class (Ratio :1600-800/1-1-1-1)
13132 KV PT -- 132KV/v3 / 110V/v3 / 110V/v3/ 110V/v3 (3P-3P-0.2) ) as per technical specification.
14132 KV PT --Temperature Rise test
15132 KV PT --Lightning Impulse voltage test
16132 KV PT -- Short circuit withstand capacity test
17132 KV PT -- High voltage power frequency wet withstand voltage test
18132 KV PT -- Accuracy Test
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail