Military Engineer Services-MES has published Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad. Submission Date for this Tender is 24-12-2021. Building Work Tenders in GE (AF) TUGHLAKABAD Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30115193
Corrigendum : Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad
Open Tender
Indian
Delhi
GE (AF) TUGHLAKABAD
24-12-2021

Tender Details

Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad Provn Of Deficient Storage Accn For Logistic Section At Af Stn Najafgarh Under Ge (Af) Tughlakabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Dec-2021 Corrigendum1 Other 13-12-2021
2 13-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-12-2021
3 21-Dec-2021 Corrigendum2 Date 24-12-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 181620.0 /-
Tender Value
Refer document

BOQ Items

Nature of Work: PROVN OF DEFICIENT STORAGE ACCN FOR LOGISTIC SECTION AT AF STN NAJAFGARH UNDER GE (AF) TUGHLAKABAD
Sl. No. Item Description
1Lumpsum price worked out by the contractor for "Building work" as listed in Sch "A" Part -I above/below the lumpsum price of Rs 9500000.00 as inserted by MES for Sch "A" Part -I on srl page No 21.
2Lumpsum price worked out by the contractor for"Site clearance, Earth Work and Excavation" as listed in Sch "A" Part II above/below the lumpsum price of Rs 246662.79 as inserted by MES for Sch "A" Part -II on srl page No 22.
3Lumpsum price worked out by the contractor for"Sewage Disposal" as listed in Sch "A" Part III above/below the lumpsum price of Rs 135539.14 as inserted by MES for Sch "A" Part -III on srl page No 23.
4Lumpsum price worked out by the contractor for"Area Drainage" as listed in Sch "A" Part IV above/below the lumpsum price of Rs 1145260.01 as inserted by MES for Sch "A" Part -IV on srl page No 25.
5Lumpsum price worked out by the contractor for"Hard Standing" as listed in Sch "A" Part V above/below the lumpsum price of Rs 924102.50 as inserted by MES for Sch "A" Part -V on srl page No 26.
6Lumpsum price worked out by the contractor for"Internal Electrification " as listed in Sch "A" Part VI above/below the lumpsum price of Rs 938572.46 as inserted by MES for Sch "A" Part -VI on srl page No 31.
7Lumpsum price worked out by the contractor for"External Electrification" as listed in Sch "A" Part VII above/below the lumpsum price of Rs 109898.34 as inserted by MES for Sch "A" Part -VII on srl page No 32.
8Lumpsum price worked out by the contractor for"Aluminium Works" as listed in Sch "A" Part VIII above/below the lumpsum price of Rs 206166.40 as inserted by MES for Sch "A" Part -VIII on srl page No 33.
9Lumpsum price worked out by the contractor for"Internal Water Supply" as listed in Sch "A" Part IX above/below the lumpsum price of Rs 15702.74 as inserted by MES for Sch "A" Part -IX on srl page No 34.
10Sch "A" Part-X (Miscellaneous B&R / E&M Items) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 signifies this fact only.
11S&F SFRC factory made drain cover/ man hole cover size 1100mmx550mm and 70 mm thick, with steel flat complete all as specified and directed.
12S&F SFRC factory made drain cover/ man hole cover size 1200mmx600mm and 70 mm thick, with steel flat complete all as specified and directed.
13Cleaning of open/covered drain and hume pipes, culverts etc and the like of any type, size of any description for silt/ earth accumulated due to storm water and spreading the cleaned earth where directed.Note :- cover slabs to be removed and refixed after cleaning with cement mortar 1:4 where covered drain exist complete all as specified and directed.
14M&L for 1x 20 watts ( 4 feet) wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including lamp complete all as specified and as directed.
15M&L for 1x 9/10 watts ( 2 feet) wall mounted LED batten,extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver including lamp complete all as specified and directed.
16M&L for ceiling fan 1200 mm sweep, five star rating, white colour complete AC single phase 230 voltsand connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable lenght from ceiling rose complete all necessary arangement of hanging of ceiling fan (GI Pipe hook etc ) as specified and directed.
17M&L for PVC exhaust fan of size 300 mm sweep, 1400 RPM single phase, single phase,230 Volt AC 50 Hz with louver shutter / grill and connection complete all as specified and directed.
18M&L for PVC exhaust fan of size 450 mm sweep, 1400 RPM single phase, single phase,230 Volt AC 50 Hz with louver shutter / grill and connection complete all as specified and directed.
19Supply and fixing LED street light 35/36watt IP 65complete all as specified and directed.
20M&L for MCB single pole 240 volts, C curve-10 KA16 Amp complete all as specified and directed.
21M&L for MCB single pole 240 volts, C curve-10 KA 06 Amp complete all as specified and directed.
22M&L for MCB single pole & neutral 240 volts, C curve-10 KA 40-60 Amp complete all as specified and directed.
23S&F porcelain insulator on angle iron frame for mounting of strip heater all as required complete all as specified and directed.
24Supply, fabrication, installation,testing & commissioning of dust & vermin proof totally enclosed, outdoor type LT, 3 phase 4 wire feeder pillar box factory made (CPRI approved), double door cubical type of suitable sizemade by3.15mm thick MS sheet with MS angle iron frame of size 40 x 40 x 6mm slanting roof, front door opening with locking arrangement complete painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary PCC for fixing with PCC 1:2:4 type B-1 using 20mm graded stone aggregate of size 0.2m x 0.2m x 0.2m for 4 Nos legs , inclusive of under mentioned items fixed inside with suitable arrangement vertically operatedand internal connection with PVC insulated stranded single core copper cable of suitable size or using insulated copper strip of appropriate size and connection of all incoming and outgoing cableincludingextended the cable from cable loop if requiredusing aluminium cable terminal sockets/lugs duly crimpled comprising of the following:-INCOMING:- (i) MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 100 Amps,breaking capacity 25 KA- 01 No Make- legrand/siemens/ schiender (ii) 4 strip copper busbar of size40x10 mm with specific colour (R,Y,B) insulation -01 set (iii) Metering panel comprising, volt meter, and ammeter, digital type with selector switches, CTs, control fused and indicating lamps.Make of volt meter/ammeter:-AE/IMP and Make of indicating lamps legrand/L&T complete all as specified. OUTGOING :- (i)04 pole on load changeover switch with advance neutral SS enclosure current rating 400/320 amp, 415 volts .Make Havells/CG/L&T (ii)MCCB, AC 415 volts, adjustable thermal & adjustable magnetic setting, 4 pole current rating 63 Amps, breaking capacity 25 KA= 02 NosMake- legrand/siemens/ schiender(iii)Spare blanking way for one Nos extra out going MCCB = 01 No
25Supply and laying well burnt bricks sub class "B" locally available of old size in trenches for protection of underground cable complete all specified and directed.
26Taking out old existing serviceable underground cable of any sizes and any capacity from trenches/pipes complete all specified and directed. Note : Necessary earth work such are exavation, returning filling shall be measured and paid seperately under respective item of earth work schedule.
27Relaying of existing under ground cable of size 70 Sqmm 3.5 core and 50 Sqmm 3.5 core complete all specified and directed.
28Taking out old existing serviceable GI pipe line of any sizes and any capacity from excavated trenches complete all specified and directed. Note : Necessary earth work such are exavation, returning filling shall be measured and paid seperately under respective item of earth work schedule.
29Relaying of existing GI pipe line of size 60 mm dia complete all specified and directed.
30Shifting of existing panel from old location to new location distance approx 35 Mtr incluing taking existing panel and disconnecting of all existing cable connection and then refixing of existing panel at new location including necessary earth work, cement work and connectionsand testing etc complete all specified and directed.
31Supply, installation, testing and commissioningair cooled split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated including necessary initial gas charging, all tubing , insulation , drain pipe upto 5 meter andall accessories complete including plateform of required size for mounting out door unit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and finishing the top surface even and smooth with using extra cementand necessaryPVC insulated copper wire 03 corecomplete all as specified and directed.Make: Hitachi/ Blue star/ Carrier
32Supply, installation, testing and commissioningair cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated including necessary initial gas charging, all tubing , insulation , drain pipe upto 5 meter andall accessories complete including plateform of required size for mounting out door unit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and finishing the top surface even and smooth with using extra cementand necessaryPVC insulated copper wire 03 corecomplete all as specified and directed.Make: Hitachi/ Blue star/ Carrier
33S&F voltage stabilizer5 KVA for automatic operation , single phase naturally air cooled indoor type, and designed for input variation betwwen 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5 % and capacity complete all as specified and directed.Make: Bluebird/ volina/ V gaurd