Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi, AVADI-Tamil Nadu

Military Engineer Services-MES has published Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi. Submission Date for this Tender is 29-12-2021. Street Lighting Tenders in AVADI Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

30114914
Corrigendum : Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi
Open Tender
Indian
Tamil Nadu
AVADI
29-12-2021

Tender Details

Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi Repair And Maintenance Of Street Light Building Security Light At Residential Area Cvrde Avadi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Dec-2021 Amd 1 BOQ 22-12-2021
2 22-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-

BOQ Items

Nature of Work: REPAIR AND MAINTENANCE OF STREET LIGHT BUILDING SECURITY LIGHT AT RESIDENTIAL AREA CVRDE AVADI.
Sl. No. Item Description
1Taking down carefully existingunserviceable LED street light fittings of any capacity & size & any make from poles and refixing the same on existing location after making the LED fitting serviceable by replacement of defective drivers/surge protection device as required with new one complete all as specified and directed Note:-(i) Spare parts required for replacement shall be measured and paid separately under relevent items 2,3 & 4 of BOQ. (ii) The cost of Replacement of minor Parts i.e. nuts/bolts,connectors etc are deemed to be included in this item.
2Supply only constant current LED driver for energy saving & environment area light fitting upto 75watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing street light of make: Surya/ C&S/ Crompton/ Havells/ Bajaj/ Philips/ Wipro complete all as specified and directed.
3Supply only constant current LED driver for energy saving & environment area light fitting upto 100watts security light with active power factor correction (APFC) electronic driver with operating voltage between 100-270V AC of suitable for existing steel lights of make: Surya/ C&S/ Crompton/ Havells/ Bajaj/ Philips/ Wipro complete all as specified and directed.
4Supply only Surge Protection Device (SPD) of capacity 10 KV for LED energy saving & environment area light of 45-90 watts security light with maximum operating voltage 320V AC, 50 Hz & maximum peak current 10 KA of suitable for existing streel lights of make: Surya/ C&S/ Crompton/ Havells/ Bajaj/ Philips/ Wipro complete all as specified and directed.
5S&F in replacement of LED street light fixture not less than 72/70 Watt LED withpressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit with suitable size GI bracket/clamps etcincluding taking taking down HPSVMV/ MH fittings complete all as specified and directed. Make:Havells Cat No ENDURACITYLINERNEOSL70WLED757 PASYBOTG/ Philips Cat No. BRP 409 LED 074 CW HE MR FG S1 PSU GR 9 / Wipro Cat part No LR02-781-XXX-57-G2
6S&F in replacement of LED street light fixture not less than 90 Watt LED withpressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP ^^ protection and impact resistance of IK07 with 10KV built in surge protection deviceMake:Havells Cat No ENDURAPEARLPLLUSSL90WLED757PASYTOP CASTHO / Philips Cat No. BRP 410 LED 094 CW HE MR FG S2 PSU GR / Wipro Cat part No LR02-781-XXX-57-XX
7M&L for taking down high mast latern unit and S&F in repair LED flood light fitting energy efficientnot less than 160Watt LED withpressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/ watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit and including provision suitable clamps/ bolts, nuts and conneting flexible copper wire including taking down unserviceable conventional flood light fittings complete all as specified anddirected. Make :- Havells JETAIRISFLS160WLED 757PWBLTG/ Bajaj BARFEG160W LED / Philips Cat No. BVP 410 LED 170 CW HE NB FG S4 XTFCL.
8S&F in repair LED flood light fitting energy efficientnot less than not less than 100Watt LED withpressure die cast aluminium housing with toughened glass,IP-66 degree of protection, luminarie efficacy 100 lumen/watt, colour temperature (CCT) of 5700K with integral electronic driver, surge protection unit and including provision suitable clamps/ bolts, nuts and conneting flexible copper wire including taking down unserviceable conventional flood light fittings complete all as specified anddirected . Make :- Havells JETAIRIS FLS100WLED757SYMLTG/ Philips Cat No. BVP 192 LED 110 CW HO NB FG GR PSU / Wipro Cat part No LD20-122-060-57-XX.
9Checking of street light fittings any type on pole/ wall to find out defect/taking out unservieceble parts such as lamp /choke/ iginiter / capacitor etc and repairing by changing the defective parts including minor repairs to cable connection/loose connection /necessary cleaning the bowl/ perpex cover whre provided and testingcomplete all as specified and as directed by Engineer -in-Charge. Note : (i) Spares of light fittings shall be measured & paid separately)(ii) The T&P Vehiclesand necessry ladders etc will be arranged by the contractor and the cost deemed to be included in the quoted rates
10Supply polyester ballast (coper wound choke)suitable forSV/MH light fitting 250 Watt. Make CG /Bajaj/Philips
11Supply iginitor electronic type suitable for SV lamp light fitting of capacity 70/150/250 Watt. Make CG /Bajaj/Philips
12Supply porcelain lamp holder pin type and screw type suitable for SV lamp light fitting of capacity 250/400 Watt.
13Supply only HPSV lamp tubler type 250 Watts . Make CG /Bajaj/Philips
14Supply and Laying XLPE cable of size 06 sqmm 2 core1100 Volt grade heavy dutyaluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/ glands as requiredcomplete all as specified and as directed.
15Supply and Laying XLPE cable of size 10sqmm 4 core1100 Volt grade heavy dutyaluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size lugs/glands as requiredcomplete all as specified and as directed.
16Supply and LayingXLPE cable of size 16 sqmm 4 core1100 Volt grade heavy dutyaluminium conductor laid in trenches / fixed to wall / pole / laid in floorincluding necessary connection and suitable size lugs/glands as requiredcomplete all as specified and as directed.
17Supply and laying GI pipe “light Grade” in trenches/ under floors or roads or along the pole for protection of cables of 40 mm bore includingtaking down u/s GI pipe any type any size complete all as specified and as directed. complete all as directed.
18Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil
19Retruning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed.
20Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed.
21Dry river sand cushioning / sand covering for underground cable protection complete all as specified. Note : Punned down thickness only shall be measuredcomplete all as specified and directed
22Supply and laying old size brick, size 230x115x75mm burnt clay building brick sub class (B) for protecting LT U/G cable complete.
23Taking down and Supply and fix in replacement of analog time switch 24 hours range suitable for autamatic ON/OFF control ofstreet light 230V,50Hz complete all as specifed and directed.
24Taking down the lanteen carrige assembly along with lanterns after replacement of worn out pully at top section of high mast ,welding putting the fell down wire rope in pully groves in proper alignment for satisfactory operation of winch system by arranging hydraulic crane from civil market having boom suitable for working at 16 mtr height all as directed and carrying out work all as directed. (Note:-i) Cost of hiring of hydraulic crane suitable for working at above 16 mtr height and T&P used for repair of high mast is deemed to be included in unit rate. ii) Spare shall be measure and paid seperatly)
25Rewinding of motor 2 HP, 3 phase, 415 volts, 1425 RPM with copper wire of existing size including providing of insulating material, bearing, bush and ,greasingvarnishing and properly packing of winding, assembling and testing complete all as specified and directed.
26Taking out old unserviceable under groundPVC/ XLPELT cable of any size from trenches/ wall/ roof/ road/ pipe/ pole including segregation of serviceable bricks for re-use complete all as specified and as directed.
27Relaying of old serviceable under groundPVC/XLPE LT cable any grade and any size in trenches/ fixed to wall/ pole/ roof/ laid in floor including necessary connections and thimbling complete all as specified and as directed. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
28Re-laying only old bricks, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete allas specified and as directed.
29Supply and fix in replacement of junction box made of inpact resistance plastic & heat resistant materials of size not less than 230x170x105mm, IP 66 protection, single left hinged door including provision of suitable terminal connector 16A capacity with MCB SP 6Aand fixing to the surface/light pole with suitable sizes of clamps, nuts and bolts complete all as specifed and directed.
30Taking down existing HPSV/LED lights and Supply and fixing energy in repairefficient LED security/street light fitting of not less than 30 Watt seasonal RTC control with dimmable type,including No. ofLED bulbs as per manufacturers instructions for lighting ofnot less than 30 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LED"s should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for cable connection complete all as directed by Engineer-in-Charge. Make- ENDURACITYLITEPLATPLUSSL30W LED757SASYBOPC of Havells/ BRP050 LED 036 CW HP SLA FG S1 PSU GRof Philips/BCLST 30W LED I of Bajaj
31Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction box/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation, returning filling, relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid separately.
32Supply and fixing in replacement of MCB , SP ,240Volt, 6 Amp 10KAall as specified and as directed.
33S&F in replacement of Power Contractor 3Pole 25A AC-3 230V Volts,50Hzcoil voltage rating 240 volts including taking down old UNSV power contractor complete all as specified and directed.
34Supply and fix in replacement ofPVC insulated, PVC sheathed,3 core multi stranded copper conductor of size 1.5 Sqmm for connecting to streetlight fitting passing through conduit fixed including taking down existing cable complete all as specified and as directed. Note:-Conduit and conduit accessories shall be measured paid separately under respective item of this schedule
35Supply and fixin replacement of medium duty non metallic PVCconduit of 20 mm bore including all fitting such as bends, elbow, coupler lock nut etc, fixed along pole with clamp for streetlight including taking down old PVC conduct of any type complete all as specified and directed.
36M&L for cleaning the steel tubularpoles of any height and thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of synthetic aluminum paint over one coat of red oxide metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including marking of pole numbers all as specified and directed.
37S&F MCCB 3 Pole, 415 V, fixed thermal and magnetic type, 25 to 100A with breaking capacity 16 KA on existing LT Panel/ Feeder pillar box include taking down complete all as specified and directed.
38M&L for cleaning the PSCC poles of any height and thoroughly with necessary cleaning agent including scrapping up of old paint dirt/dust carefully and applying two coat of cement based paint over one coat of primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of cement based paint including marking of pole numbers all as specified and directed.
39Taking down Old unserviceable PCC pole and Supply, install and testing of Galvanized Octagonal Street Pole6 mtr long,Bottom dia 130 mm and Top dia 70 mm, Wall Thickness 3 mm, Base Plate 220 x 220 x 12 mm thick with Inbuilt Junction Box, 3 mm thick Acrylic sheet. The Bracket shall be 04 Arms with 1 mtr Long. The pole shall be fixed with M16 x 600 Foundation Bolt and nut embadded in Concrete with templates as specified by OEM complete all as specified and directed by Engineer-in-Charge. Note: i) The Rate quoted shall includes for Earth work excavation in any type of soil, Concrete foundation and foundation bolts. ii) The depth of excavation and grade concrete shall be as per OEM specifcation.
40Taking down Old unserviceable PCC pole and Supply, install and testing of Galvanized Octagonal Street Pole6 mtr long,Bottom dia 130 mm and Top dia 70 mm, Wall Thickness 3 mm, Base Plate 220 x 220 x 12 mm thick with Inbuilt Junction Box, 3 mm thick Acrylic sheet. The Bracket shall be 01 Arms with 1 mtr Long. The pole shall be fixed with M16 x 600 Foundation Bolt and nut embadded in Concrete with templates as specified by OEM complete all as specified and directed by Engineer-in-Charge. Note: i) The Rate quoted shall includes for Earth work excavation in any type of soil, Concrete foundation and foundation bolts. ii) The depth of excavation and grade concrete shall be as per OEM specifcation.
41Taking down Old unservicaeable PCC pole and Supply, install and testing ofsteel tubular swaged pole 4Meter with suitable size MS base plate and entry holes at the bottom and foundation bolt as per require size,single arm mounting bracket (single swan neck)with support pipe/plate with bolts and check nutsfor fixing the street light fittingand internal bus bar chamber with 4 way connector, flush type hexagonal screws for connecting the in/out cables and required cable from connector to light fitting, open raft shallow footing of required size to match with the base plate and standard drawing all as per design ofpoles approved by Engr-in-charge. Note: i) The Rate quoted shall includes for Earth work excavation in any type of soil, Concrete foundation and foundation bolts. ii) The depth of excavation and grade concrete shall be as per OEM specifcation.