Public Health Engineering Department-PHED has published Empanelment Of Eligible Contractors At Provincial Level And Fixing Of Item Rates For Lift Schemes Of Plain Areas Of District Baramulla For Execution Ofjal Jeevan Mission ( Jjm ) Works More Then 50 Lacs Upto 100 Lacs - Group Iv Phe Division Sopor. Submission Date for this Tender is 24-01-2022. Coats and Jackets Tenders in Sopore Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-Dec-2021 | Corrigendum | Technical Bid | 01-01-2022 |
2 | 03-Jan-2022 | Extension I | Date | 12-01-2022 |
3 | 13-Jan-2022 | Extension II | Date | 24-01-2022 |
Sl. No. | Item Description |
1 | Dismantling of GI pipeincluding earthwork excavation, removing of pipe, stackingwithin 50m lead and refilling of trenches complete .Above 40mm |
2 | Above 40mm |
3 | Below 40mm |
4 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated upto 1mt from cutting edge earth as directed: |
5 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated upto 1mt from cutting edge earth W. B.Macadem |
6 | Earth work in excavation by manual means over areas (exceeding 30cm and up[to 1.5mtr in depth, 1.5mtr in width as well as 10 sqm on plan) including disposal of excavated earth upto 1mtr from cutting edge disposal earth to be leveled and neatly dressed .All kinds of soil |
7 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, Ordinary Rock |
8 | Extra for every additional lift of 1.5 mtr. or part thereof in all kinds of soil |
9 | Earth work in excavation by mech. means over areas (exceeding 30cm and up[to 1.5mtr in depth, 1.5mtr in width as well as 10 sqm on plan) including disposal of excavated earth upto 1mtr from cutting edge disposal earth to be leveled and neatly dressed .All kinds of soil |
10 | Supply , Filling of good earth incl. Consolidation incl. All carriages upto site of work. |
11 | Laying and fitting of G.I Pipes 100mm ø G.I = |
12 | Laying and fitting of G.I Pipes 80mm ø G.I = |
13 | Laying and fitting of G.I Pipes 65mm ø GI |
14 | Laying and fitting of G.I Pipes 50mm ø G.I = |
15 | Laying and fitting of G.I Pipes 40mm ø G.I = |
16 | Laying and fitting of G.I Pipes 25mm ø G.I = |
17 | Laying and fitting of G.I Pipes 20mm ø G.I = |
18 | Laying and fitting of G.I Pipes 15mm ø G.I = |
19 | P/F of flanges incld. Cutting, welding, insertion of rubber Gasket, nuts bolts incld. Earth work & refilling incl all carriage and head load complete job. 80mm dia G.I |
20 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job 200 mm |
21 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job150 mm |
22 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job125 mm |
23 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job 100mm |
24 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job 80mm |
25 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job 65mm |
26 | Providing and fixing of 10mm thick MS flangesto Gi pipes incl cutting of pipes , incl c/o flanges , nuts ,bolts , RI cloth and all sorts of carriage of pipes complete job 50mm |
27 | Providing and fabrication of MS/Gi bend, TEES ,as per various goundprofile pipe specials at site made out of MS pipe incl c/o pipe , flanges , nuts, bolts , RI cloth and all sorts of carriage upto site of work complete job 100mm/125mm |
28 | Providing and fabrication of MS/Gi bend, TEES ,as per various goundprofile pipe specials at site made out of GI/MS pipe incl c/o pipe , flanges , nuts, bolts , RI cloth and all sorts of carriage upto site of work complete job 80mm |
29 | Flanged 100mmTee,bend |
30 | Flanged GI150mm bend |
31 | Rethreading of damaged ends of various dia pipes40mm |
32 | Back-filling of available excavated soil into the trench excluding rock. |
33 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete |
34 | 25 to 40 mm nominal bore |
35 | 40 to 80 mm nominal bore |
36 | Providing and laying S&S Centrifugally Cost ( Spun ) Iron Pipes ( class K7) 150mm Dia |
37 | Providing push on joints to centrifugally Cast of spun Iron S&S including testing of joints & Cost of rubber gasket200mm |
38 | 80mm dia Sluice valve |
39 | 100mm dia Sluice valve |
40 | 150mm dia Sluice valve |
41 | 200mm dia sluice valve |
42 | Providing and fixing Ci double acting air valve of approved quality with bolts nuts rubber insertions etc complete ( The tail pieces, tapers etcif required will be paid sepately ) |
43 | 50m dia Double acting |
44 | Providing and fixing of MS bends of required dia and TEE"s including carraige of welding machine upto site of work and fixing at site including cost of rubber gasket/washers/ nuts & bolts etc as complete job |
45 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)15mm |
46 | 25 mm dia |
47 | 40 mm dia |
48 | 50 mm dia |
49 | 65 mm dia |
50 | Providingand fixing of ISI marked double flanged sluice valves approved make of Kirloskar etc including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 200mm |
51 | Providingand fixing of ISI marked double flanged sluice valves including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 150mm |
52 | Providingand fixing of ISI marked double flanged sluice valvesapproved make of Kirloskar etc including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 125mm |
53 | Providingand fixing of ISI marked double flanged sluice valvesapproved make of Kirloskar etc including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 100mm |
54 | Providingand fixing of ISI marked double flanged sluice valvesapproved make of Kirloskar etcincluding c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job (80mm |
55 | Providingand fixing of ISI marked double flanged NRV including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 125mm |
56 | Providingand fixing of ISI marked double flanged NRV including c/o nuts, bolts RI cloth ,tail pieces and all sorts of carriage upto site of work complete job ( W/o, Supply & Over flow) 100mm |
57 | Providing and fixing of air valve ISI marked including c/o flanges ,nuts ,bolts ,RI cloth , tail pieces and all sorts of carriage upto site of work complete job .20mm |
58 | Providing lying and fixing/jointing (rich mix concrete) of spun pipe NP3 type including earthwork excavation of tenches as specified to withstand the traffic load including sand coushioning by 2nd class sand and cost of pipe.The job omc;ides a;; sprts pf carriage upto site of work complete job (TO BE UTILISED AS SLEEVES) 300mm |
59 | Providing lying and fixing/jointing (rich mix concrete) of spun pipe NP3 type including earthwork excavation of tenches as specified to withstand the traffic load including sand coushioning by 2nd class sand and cost of pipe.The job omc;ides a;; sprts pf carriage upto site of work complete job (TO BE UTILISED AS SLEEVES) 400mm |
60 | Cutting of road and making good the same incl all aggtegates required to complete the job |
61 | Providing and laying stone soling hand packed on level |
62 | Providing and laying cement concrete in1:4:8with 40 mm stone size agg. Crushed excluding cost of shuttering |
63 | Providing and laying of reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, pots and struts etc upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20mm nominal size) |
64 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts any struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement in1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone agg. 20mm nominal size). |
65 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc upto floor five level excluding cost of centering, shuttering finishing and reinforcement 1 : 1.5 : 3 ( 1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size). |
66 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. |
67 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc upto floor five level excluding cost of centering, shuttering finishing and reinforcement 1 : 1.5 : 3 ( 1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size). S/Floor |
68 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts any struts, etc. upto floor five level excluding cost of centering, shuttering, finishing and reinforcement in1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone agg. 20mm nominal size). |
69 | Reinforced cement concrete work in arches, archibs, domes, vaults, shells, folded plate and roofs having slope more than 15º upto floor five level incld. curing but excld. The cost of centring, shuttering finishing and reinforcement with 1 cement : 1.5 coarse sand : 3 graded stone agg.) 20mm nominal size incld. all carriages |
70 | Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with:5.6.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
71 | Providing and laying incement concrete of specified grade upto plinth level etc. excluding the cost of centering and shuttering. All work upto plinth level 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone) aggregate 20mm nominal size Crushed. |
72 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level 1 : 2: 4 crushed. |
73 | Providing/laying of plain cement concrete in 1 : 3 : 6 mix excluding cost of centring and shuttering, finishing and reinforcement. All works upto plinthlevel for thrust blocks. |
74 | Cement concrete flooring in 1:2:4 mix finished with floating coat of neat cement |
75 | Extra For RCC work In Super Structure above floor V Level for Each Floor |
76 | Providing and incorporating during Construction joints GP Sheet |
77 | Providing and fixing of lightening copper conductor of approved quality and make with 0.60 x 0.60 mtr 12mm thick copper plate Complete job |
78 | Reinforcement for RCC work including straightening, cutting ,bending ,binding and placing in position completeTMT |
79 | Extra for providing water proofing compound to cement concrete works. |
80 | Foundation, footing bases of columns |
81 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses |
82 | Arches, domes valuts upto 6m span |
83 | Suspended floors |
84 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
85 | Column, Pillar |
86 | Edges= |
87 | Extra for shuttering In circuilar work (20 % of respective centring and shuttering items): Foundations, footing, bases of columns etc for mass concrete |
88 | Extra for shuttering in circular works. Walls |
89 | Extra for shuttering in circular works. Dome |
90 | Extra for shuttering In circuilar work (20 % of respective centring and shuttering items): Suspended floors |
91 | Extra for shuttering In circuilar work (20 % of respective centring and shuttering items): Linets beams |
92 | 12mm cement plaster of mix 1 : 3 (1 cement : 3 fine sand) incld. all carriages |
93 | 12mm thick C. Plaster in 1:4 mix |
94 | 15mm thick cement plaster finished without floating coat of neat cement of mix 1: 4 mix (1 cement : 4 fine Sand). |
95 | Extra for plastering on circular Wall one coat. |
96 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like |
97 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
98 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
99 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
100 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
101 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 10.26.1 M.S. tube |
102 | Providing and fixing of MS lid of size 0.75x0.75 made out of angle iron 50xx50x6 with all locking arrangement complete |
103 | Provding, fabrication of MS lid of size 0.45x0.45 mtr with frame made out of angle iron 40x5 with MS sheet covering of 3mm thick wir gaugeincluding locking arrangements complete the job includes applying two coats of approval paint over zinc chromate primer |
104 | Providing and fixing of 1mm thick M.S sheet door for frame 40x40x6mm incld. locking arrangements complete job |
105 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in charge. 16.25.1 Made of G.I. wire of dia 4 mm |
106 | Boulder filling in rooms inclduing handpacking and laying etc complete |
107 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4( 1 cement : 4 coarse sand) |
108 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
109 | Extra for brick work in super structure above plinth level upto floor V level. (by manual level) |
110 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etcincluding cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1metres or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (plan area to be measured |
111 | Providing , hoisting and fixing trusses / purlins , rafters , posts , plates or like componenets incl c/o screws etc complete Popular wood |
112 | Providing CGI sheet roofing incl GI washers of specified size excl c/o purlins , etc incl cutting to size & shape wherever required (0.50mm) |
113 | Providing color coatedsheet roofing incl GI washers of specified size excl c/o purlins , etc incl cutting to size & shape wherever required (0.63mm) |
114 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
115 | Providing and fixing of 200mm wide Eaves boarding |
116 | Providng and fixing of soffits of MS sheet of 2mm thickness incl support / frame complete of specified size and guage incl nuts bolts |
117 | Supplying and fixing rolling shutters of approved make, made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire springs manufacture from high tensile steel wire of adequate strength confirming to IS 4454 part 1 and M.S top cover of required thickness for rolling shutters. 80x1.25mm M.S laths with 1.25mm thick top cover |
118 | Providing and fixing ball bearing for rolling shutters |
119 | Providing and fixing rods of 1.25mm thick crominium plated brass plates with 2 cromium plated brass brackets fixed with CP brass screws and wooden plugs etc. whatever necessy complete 25mm dia |
120 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
121 | Providing and fixing panelled or panelled &glazed shutters for door windows using 4mm thick glass panes including MS pressed butt hinges bright finished off required size with necessary screws excl c/o glass panes 2nd class deodar wood |
122 | Providing and fixing wire gauze shuttersof 30mm thickness butt hinges bright finished off required size with necessary screws |
123 | Providing and fixing pannelled and glazed shutters 35mm thick |
124 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4mm |
125 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5mm |
126 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 10kg/sqm (4mm thick) float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Second class kail wood |
127 | Providing & fixing aluminium sliding door bolt ISI marked annodized (Anodic coating not less than grade AC 10 as per IS-1868) transparent or dyed to required colour or shade with nuts and screws etc. complete |
128 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :100mm |
129 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100mm |
130 | Providing and fixing of nuts and bolts and chip including one end fix anchor block |
131 | Providing and fixing 80mm dia PVC pipes for areation purpose |
132 | Providing and fixing finished brass door latchwith necessary screws etc |
133 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat preperation of surfaces, etc complete. |
134 | Painting ofwood work with synthetic enamel paint of approved brand and manufacture ( Two or more coats) |
135 | Applying Priming coat with ready mixed red oxide zinc chromoate primer of approved paint and manufacture on steel galvanized iron/steel works |
136 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer ( Qty as per item no 19) |
137 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
138 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
139 | Finishing walls with water proofing cement paint of required shade: 13.117.1 Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat |
140 | Supply , fabrication and fixing in position MS Edge cutterof internal diameter of 5.10m made out of 12mm MS plate & 8mm plate, internally supported y 75X75x 6mm with proper anchorage with supporting platesincl all welding and as per directions of Engineer Incharge |
141 | Sinking of well through all type of soil completeincl exacvating of earth , disposal& dewatering during sinkingas per specificatons and directions of Engineer Incharge complete |
142 | Providing, placing earth filled bags incl excavating earth from borrow pits , filing of bags, sewing, stitching , stacking and placing in position as per the diractions of Engineer Incharge incl all sorts of carriagecomplete job . The job includes demolishing of same after successful commissioning of the job |
143 | Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as perthe direction of Engineer-in-Charge. 20 mm dia and 350 mm length |
144 | Providing ,fabrication and fixing of 200/150mm dia MsFlanged bend / tail pieces , specials etcofincl c/o nuts bolts RI cloth,welding etcas per directions of engineer Inchargecomplete job |
145 | Providing . Installation , testing and succeessful commissiononig of sludge motor of required discharge 1000 LPMupto 7.5hp 3phasecapacity and head upto 10mtr includingall sorts of accessories required like Providing & Fitting of25 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting motors from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement .make phenolix/havells/KEI,Fabrication , erection of gantry in MSfabricated out of MS Pipefor vertical support and ISMB 200 for horizontal supports , DOL starter 7.5 hp , panel boardfor gadjets of required specification with preventive devices & earthig, Chain pulley, gantry, anddisposal pipe ,Fabrication of canopy 3’x3’ size for chain pulley block fabricate out of ISA 40x40x4mm and CGI sheets (Green Shade)to house the gadjet like panel board& all sorts of accessories required to complete the job |
146 | Providing, installation, testing and commissioning of 50 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer & p/f of 25sqmm cable armoured 30mtr xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 50 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. |
147 | Constructing of Earthling station :Supply , installation , testing and commissioning of earthing electrode comprising of company fabricated earthing electrode as per IS :3043 for carrying out earthing . The job includes drilling / boring of 200 mm dia bore to the depth of 6 feet . Connectingthe cable tray through GI strips of suitable thickness besides making surface pit in brick / cement concrete of appropriate size. The earthing electrode shall be of 76/80mm dia and 1.83 mtr length of reputed make. The backfilling properly mixed compound as required . |
148 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm |
149 | Providing and fixing Salem Stainless Steel A lSI 304 (18/8) kitchen sink as per I.S. 13983 with C.l. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board 510 x1040mm Bowl depth 250mm |
150 | Providing and fixing of Wash Basin 460 mm |
151 | Providing & fixing PVC soil waste and vent pipe. |
152 | 100mm |
153 | 75mm |
154 | Providing & fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls etc. (Internal works). |
155 | 15mm dia nominal bore ( Light weight ) |
156 | Providing & fitting oflighting points foras per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulatedcopper conductor through pvcconduit pipe/channel by way of p / f of pearl or non-ploy carbonate angle holders , pvc gang box, switches, socket modules , regulators ,indicators,distriution box08/10 watt LED lamps Surface light Make(/Havells/Phillips/GM/syska). Make items Anchor, klick, S S K, Indo Asian, Philips, Havells .Included is cost on account of modular switch boards,10amp MCB ,with the wooden frames as per site requirements |
157 | Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit //channeby way of p / f of 15 Amp switches, ,16ampMCB,6 pin socketon modularfitting of Anchor, Philips, GM ,make as per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm. |
158 | Providing and fixing 12mm thick plyboard for covering yhe ceiling area incl c/o frames, supports , battens inclallosorts of screws etc complete job |
159 | 15mm thick cement plaster finished with floating coat of neat cement of mix 1: 4 mix (1 cement : 4 fine Sand). |
160 | Dry Random Rubble stone masonry hard stone |
161 | Dry stone filling inside shaft plan area |
162 | P/F WC indian type(0.45x 0.60) |
163 | P/F PVC low level flushingof 10 ltr capacity |
164 | providing and fixingof kitchen sink |
165 | p/F of trap 100 dia |
166 | P/FPVCsoil waste 100/80 & 50mm ventpipe |
167 | P/F of PVC specials |
168 | Tee 100x100 |
169 | 100 Bend |
170 | Providing and fixing DI tail piece male /female to DI/CI pipes one side socketed and one side Flanged including all sorts of carriages upto site of work complete job. |
171 | 100mm dia |
172 | 150mm dia |
173 | 200mm dia |
174 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc |
175 | Providing & fixing on Terrace ( at all floor levels) polyetheline water storage tank ISI 12701 marked indicating the BIS license no. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank ( Syntex,Electroplast,Star,Lotus or equivalent having valid ISI license. |
176 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
177 | P/ f of ceramic glazed tiles of approved quality on 20mm thick bed of cement mortar 1:4 mix incl pointing of joints with white cement |
178 | Pointing on brick work in 1:3 mix |
179 | P/F of holdfast |
180 | P/f of tower bolts |
181 | Providing anf Fixing Sliding door bolts heavy duty |
182 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of app Quality |
183 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make. |
184 | Providing and fixing 15mm nominal bore CP mixer of approved make |
185 | Providing Fixing od Soap Holder |
186 | Providing fixinf of wood work in trusses, purlins, Rafters etc. In Budloo/ fir wood |
187 | Providing and fitting of service line 7/16 of specified specificationcomplete job |
188 | Providing , Installation of approved make Gyser of 50ltr capacity including CP pipe,nipplesetc as per directions of Engineer inchargecomplete job |
189 | Preparation of subgrade by excavating earth to an average depth, dressing to camber and consolidation with road roller of 8-12 tonne capacity including making good the undulation etc. and disposal of surplus earth upto 50 meters. |
190 | Supply , stacking of GSB max size agg 90mm incl consoldationwith road roller incl spreading , watering and carriage complete |
191 | Supplying and stacking at site Graded crushed stone aggregate of size 63 to 45 mm |
192 | Supplying and stacking at site Graded crushed stone aggregate of size 53 to 22.4mm |
193 | Supplying and stacking at site Graded crushed stone aggregate of size icl all Carriage complete |
194 | Laying, spreading and compacting stone aggregate of specified sizes toWBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
195 | Spreading 6 mm thick red bajri, watering and rolling complete including preparation of the surface and rolling (Payment for red bajri to be made separately): |
196 | Carraige of pipes fromsoure upto actual site of work by mechanical transport including loading and unloading for an avg lead of 25 kms |
197 | Below 100 mm dia. GI Pipes |
198 | Carriage of pipe 200mm from from divisional store by avg lead of 12km |
199 | Carraige of Materials fromsoure upto actual site of work by mechanical transport including loading and unloading for an avg lead of 25km |
200 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: Cemenet/Steel for avg. lead |
201 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: Sand for avg. leadkms |
202 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: Stone soling for avg. lead |
203 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: Stone agg. 40mmfor avg. lead 20kms |
204 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: Stone agg. 20mmfor avg. lead 20kms |
205 | Carriage of materials by Mechanical transport from source to actual site of work including loading, unloading and stacking of material: bricks for avg. lead 75kms |
206 | Head load from different materials from dumping site upto actual site of work by 300 m |
207 | Pipes |
208 | Cement /steel |
209 | stone aggregate/ Sand |
210 | Stone soiling |
211 | Mechanical Components |
212 | Supply, installation, testing and commissioning of submersible pumping unit of below mentioned parameters to be lowered inside well casing having inside diameter of 200mm (Proposed) Pump : Type Submersible [Multistage Bowl Type] Speed 2900 RPM Discharge 4000 GPH at 50 m head Material of impellerBronze/SS Impellers Dynamic Head 30-90 Mts Shaft Material Stainless steel Fluid to be handles Raw water Make M&P/KSB/KirloskarMOTOR /PRIME MOVER: Type Submersible Speed 2900 RPM Phases 3 - Phase AC supply , 50 Hz frequency Make M&P/KSB/Kirloska Capacity Corresponding to head and discharge(not less than 15 HP)Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 420 volts, 50 HZ .The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a)The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips/rods of suitable size and length. b)The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of 18 mm thickness at other end for 65mm dia column pipe .The threaded portion should be as per size of pumping out let for proper fixing.c) Providing and fitting of M.S clamp (comprising of 2 parts/Nos) to be fitted using M.S fasteners for holding of 65 mm Dia column pipes in hanging position at top/ over Well casing.(02 Sets)d) Fabrication, providing and fitting of 65 mm dia MS pipe of length minimum 3 feet long as per site requirement and 65mm dia MS bend both fitted with 18mm thick flanges on both sides.(with R.I. cloth/rubber washers , nuts, boltsThe job includes providing and fitting of R.I cloth joints/rubber washers with nuts, bolts and washers for all joints as per site requirement. The job also includes proper testing and commissioning of pumping unit on full load at site and providing of test certificate of pumping equipment is compulsory. |
213 | Supply, installation, testing and commissioning of submersible pumping unit of below mentioned parameters to be lowered inside well casing having inside diameter of200mm(Proposed) Pump: TypeSubmersible[Multistage Bowl Type] Speed2900 RPM Discharge5000 GPH at 90 m head Material of impellerBronze/SS Impellers Dynamic Head 80-120 Mts Shaft MaterialStainless steel Fluid to be handlesRaw water Make M&P/KSB/Kirloskar MOTOR /PRIME MOVER: Type Submersible Speed 2900 RPM Phases3 - Phase AC supply , 50 Hz frequency MakeM&P/KSB/Kirloskar CapacityCorresponding to head and discharge (not less than20 HP) Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 420 volts, 50 HZ .The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a)The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips/rods of suitable size and length. b)The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of 18 mm thickness at other end for 65mm dia column pipe .The threaded portion should be as per size of pumping out let for proper fixing. c) Providing and fitting of M.S clamp (comprising of 2 parts/Nos) to be fitted using M.S fasteners for holding of 65 mm Dia column pipes in hanging position at top/ over Well casing.(02 Sets) d) Fabrication, providing and fitting of 65 mm dia MS pipe of length minimum 3 feet long as per site requirement and 65mm dia MS bend both fitted with 18mm thick flanges on both sides.(with R.I. cloth/rubber washers , nuts, bolts The job includesproviding and fitting of R.I cloth joints/rubber washers with nuts, bolts and washers for all joints as per site requirement. The job also includes proper testing and commissioning of pumping unit on full load at site and providing of test certificate of pumping equipment is compulsory. |
214 | Supply, installation, testing and commissioning of submersible pumping unit of below mentioned parameters to be lowered inside well casing having inside diameter of200mm(Proposed) Pump: TypeSubmersible[Multistage Bowl Type] Speed2900 RPM Discharge5000 GPH at 90 m head Material of impellerBronze/SS Impellers Dynamic Head 70-120 Mts Shaft MaterialStainless steel Fluid to be handlesRaw water Make M&P/KSB/Kirloskar MOTOR /PRIME MOVER: Type Submersible Speed 2900 RPM Phases3 - Phase AC supply , 50 Hz frequency MakeM&P/KSB/Kirloskar CapacityCorresponding to head and discharge (not less than25 HP) Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 420 volts, 50 HZ .The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a)The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips/rods of suitable size and length. b)The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of 18 mm thickness at other end for 65mm dia column pipe .The threaded portion should be as per size of pumping out let for proper fixing. c) Providing and fitting of M.S clamp (comprising of 2 parts/Nos) to be fitted using M.S fasteners for holding of 65 mm Dia column pipes in hanging position at top/ over Well casing.(02 Sets) d) Fabrication, providing and fitting of 65 mm dia MS pipe of length minimum 3 feet long as per site requirement and 65mm dia MS bend both fitted with 18mm thick flanges on both sides.(with R.I. cloth/rubber washers , nuts, bolts The job includesproviding and fitting of R.I cloth joints/rubber washers with nuts, bolts and washers for all joints as per site requirement. The job also includes proper testing and commissioning of pumping unit on full load at site and providing of test certificate of pumping equipment is compulsory. |
215 | Supply, installation, testing and commissioning of submersible pumping unit of below mentioned parameters to be lowered inside well casing having inside diameter of200mm Pump: TypeSubmersible[Multistage Bowl Type] Speed2900 RPM Discharge7500 GPH at 110 m head Material of impellerBronze/SS Impellers Dynamic Head 80-120 Mts Shaft MaterialStainless steel Fluid to be handlesRaw water Make M&P/KSB/Kirloskar MOTOR /PRIME MOVER: Type Submersible Speed 2900 RPM Phases3 - Phase AC supply , 50 Hz frequency MakeM&P/KSB/Kirloskar CapacityCorresponding to head and discharge (not less than25 HP) Submersible motor should be water filled water lubricated squirrel cage type having capacity for above pumping parameters and working on 3 phase; AC supply ranging from 380 to 420 volts, 50 HZ .The motor should be sealed by radial rings to avoid mixing of well water with motor filled water. a)The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips/rods of suitable size and length. b)The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of 18 mm thickness at other end for 65mm dia column pipe .The threaded portion should be as per size of pumping out let for proper fixing. c) Providing and fitting of M.S clamp (comprising of 2 parts/Nos) to be fitted using M.S fasteners for holding of 65 mm Dia column pipes in hanging position at top/ over Well casing.(02 Sets) d) Fabrication, providing and fitting of 65 mm dia MS pipe of length minimum 3 feet long as per site requirement and 65mm dia MS bend both fitted with 18mm thick flanges on both sides.(with R.I. cloth/rubber washers , nuts, bolts The job includesproviding and fitting of R.I cloth joints/rubber washers with nuts, bolts and washers for all joints as per site requirement. The job also includes proper testing and commissioning of pumping unit on full load at site and providing of test certificate of pumping equipment is compulsory. |
216 | Providing, installation, testing and commissioning of vertical turbine pumping unit driven by hollow shaft motor for pumping water at an altitude of 1584 M (AMSL). The specification are as underas per Design enclosedfor stage 1st : “A” Pump: 1. Discharge =15000 GPH 2. Type = Self water lubricated, vertical turbine pump, open line shaft type with delivery above floor level. 3. Liquid to be handled = Contaminated water having solids in suspension 4. RPM = 1450 5. Head = 48Meters 6. Efficiency = 75% without negative tolerance 7. Material of Impeller = Semi enclosed open shrouded impellers mixed flow (Bronze grade V of BIS 318) 8. Material of Line shaft and line shaft coupling = Stainless steel AISI-410 9. Material of impeller shaft = Stainless steel AISI-410 10. Intermediate shaft = Stainless steel 11. Column pipe = Mild steel column pipe as per IS226/2062, minium 150mm nominal dia, total length not to increase 10m (lengths for columns shall be 3.04m+2.43m+1.52m+1.52m+0.61m) i.e. to be fabricated in suitable pieces 12. Suction strainer = MS fabricated 13. Bell mouth = CI 14. Pump Bowl = CI (pump bowls should be fastening through screws) and not more than 4 stages 15. Levels: Sump bed level = 100 Meters Machinery floor level = 112 Meters Minimum water level = 1.5 Meters Minimum submergence = 1.5 Meters Level are as per design of sump/cum pump house. Pump bowl to be designed with minimum number of stages not more than 4 Stages. Make= WIPL / Kirlorkar / Mather Platt "B" Motor 1. Type = Hallow Shaft AC Squirrel cage induction motor 2. Rating = not less than 25 HP 3. Frequency = 50 ± 3 % Hz 4. Working Voltage = 380 ± 15 V, 03 phase 5. RPM = 1450 (sync) 6. Efficiency = Not less than 80% 7. Class of insulation = F 8. Enclosure = TEFC 9. IS standard = IS 325-1970 |
217 | 10. Quantity = One Number 11. Make = Kirlosker/ABB 12. Bearings = Thrust bearing shall be suitable and of adequate capacity to carry the weight of all rotating parts and the hydraulic down thrust. 13. Ratchet = Non-reversing ratchet or similar mechanism should be provided to the motor to prevent reverse rotation. 14. Continuous maximum rating = Continuous maximum rating of the motor shall be at least 20% above the maximum power absorbed by the pump under any operating point within stipulated head range of the pump or at least 10% above the power required at shut-off, whichever is higher. 15. Discharge Head: Discharge head shall be fabricated from MS. It shall be incorporated in full diameter elbow mounting flange for motor with suitable tapping for pressure gauge. The discharge head shall be of robust construction and shall be designed to support entire static and dynamic load of pump assembly, water column and motor. The discharge head shall have an arrow indicating direction of rotation of pump. The discharge head may have a stuffing box with renewable bushing. The location shall be easily accessible. The lantern ring and gland follower shall be split type. It shall incorporate suitable arrangement to collect gland leakage and lead to sump with suitable piping. The discharge head should have suitable size valve arrangement for air release |
218 | Providing and fitting and 35 sq mm ABC HT cable 30 mtrs in lengthfor making connections at tapping point and providing and fitting of 35 sq mm ABC HT insulator kit-02 sets (one set comprises of 3 pieces) |
219 | Providing , fitting, testing and commission of heavy duty de-silting pumping unit complete unit of capacity 15000 GPH head 25 m and motor including compete cabling, starter- 2nos(one as standby), Sluice valves ,agitator function, delivery pipe minimum 50 m with MS supports with all joints and accessories. Complete job Job includes fabrication , providing , fitting and testing of gantry system for fabricated out of ISCM/ISMBbelow machine floor of circular shape approx. 7 m dia.The gantry system should be fabricate in such a way that desilting pumping unit should move in all directions. Job includes providing and fitting of 2 MT chain pulley block (chain lift 10 m)and monorail of induff/globe make. the de-silting pumping have. Job also includes providing and fitting of 2MT electric hoist with monorail for said units. Job also includes making of hole and covering of the same with 8 mm thick MS sheet & ISA. Job also includes fabrication of Ladder and plate form at middle in ISA,ISMC for handling of the system. |
220 | Providing and fitting of 42.68 meters 65 mm Dia MS pipes ( thickness 3.6 mm) of length 10 (each pipe) feet to be used as Column pipes & to be fitted inside the well casing ( Flanges should be fabricated keeping well casing dia 200mm & submersible cable in consideration). The Job includes p/f of 2 No MS 65 mm nominal dia, 18 mm thick flanges welded to extreme ends of the pipe with Coating of red oxide anti-corrosive paint to whole arrangement. The job includes providing and fitting of R.I cloth joints/rubber washers with nuts, bolts and washers for all joints. The Job also Includes P/F/Welding of Triangular shaped plates [2 No’s] for strengthening to each flange along with cutting/making of two groove for each flanges for carrying Submersible Cable. |
221 | Fabrication , Providing , Fittingand testing of delivery manifold Y-junction system fabricated out of M S ( heavy class) 150mm dia pipes. The job also includes fabrication, providing and fitting of 150mm dia MS bends, including flanges, tabular flanges, increasers, reducers, nuts and bolts, gaskets as per site requirement. The job also includes p/f of 02 No’s 150mm dia NRV PN 1.6 of VAG/AVK make and 02 No’s 150mm dia Sluice Valve PN 1.6 of VAK/AVK make. Job Also includes fabrication of base frame in ISMC 200 -17m, 8mm thick MS Plate 5 sq m for V.T. Pumping units as per side requirement . Job also includes painting of delivery manifold with one coat of red oxide and two coat of paint.(Colour as per direction of site engineer) . Thejob also includes fabrication providing and fitting of washout system in 100 mm dia MS Pipe (Heavy class) 18mts includingP/F fittingof 100 mm dia sluice valve 01 no, bends,offsets , flanges as per site requirement.Job also includes providing and fitting of flanged tail piece . |
222 | Providing and fitting of 10-12 mm Dia Steel wire rope for holding of Pump/motor unit & column pipes in hanging position at top over Well casing as a safety measure/precaution to avoid detachment of Pumping unit inside well .Includes providing & fitting of D clamps as per site requirement. |
223 | Providing & fitting of 80mm dia flanged DI NRV , Make: VAG /AVK make (PN 16). Job includes two number table flanges connected to delivery pipe. Job also includes p/f of RI cloth with nuts and bolts. |
224 | Providing & fitting of 80mm dia flanged sluice valve , Make: Vag /AVK make (PN 16). Job includes two number table flanges connected to delivery pipe. Job also includes p/f of RI cloth with nuts and bolts and one MS flanged Bend |
225 | Providing and laying of ISI marked 3-core 16 sq.mm water proof Submersible cable of Phenolex/Havells make from starter to motor. Job includes cost of 2 inch dia PVC conduit, earth excavation for its underground from well to panel as per site requirement. Job also includes p/f of 6 no cu thimbles of suitable rating to said cable for connection purpose.. |
226 | Design , manufacturing , providing , erection, testing and commissioning of 3 MT capacity overhead gantry system made out of diff. steel structures viz. MS Plates, MS pipes by various operations viz. cutting, welding and buffing etc.a) Vertical posts made out of 150 mm dia pipe of 5.9 mm thickness ( 2x 20’=40‘ ) Horizontal ISMB 200 mm dia. = 1 x 10’= 10’b) Top surface plate made out of simple MS plate 8mm thick. The job needs fitting of nuts , bolts and welding of Upper Side : 2x 1’ x 1’ Lower side : 2 x 1’x 1’ Base plate : 2 x 1’x 1’ c) Earth excavation of size 2 ½’ x 2 ½’ x 3-9” . 6”in height is to be filled with boulder and 3” in mud mate. c) Foundation blocks of size 2 ½’ x 2 ½’ x 3’ to be laid in M 20 mix. The job includes earth excavation and grouting of the base plat in foundation block as per site requirement. d) Providing and fitting of 10’ x 8’ canopy over the gantry by way three trusses of MS angle[50x50x5]mm and CGI sheets [26 guage] with allied fixtures. e) Supply installation, testing & commissioning of 01 number 03 ton capacity chain pulley block having chain minimum lift of 6m with mono rail Make :Pull Lift/Indeff/globe . Complete with U. clamps, chain, hooks and other allied fixtures. f) Supply , installation , testing & Commissioning of 01 number 03 MT capacity electric hoist with minimum 6 m lift. Make: pull lift/ Indeff/ Globe. With monorail Complete with U clamp, chain hooks and other allied fixtures f) Fitting of 1.5’ long 50x50x5mm angle iron pieces for fabrication of ladder on one of the two vertical posts. g) Providing and finishing by anti- corrosion coating, buffing and two coats of painting of whole gantry with approved shade |
227 | Construction of (10"-0"x8"-0"x4"-0") gravel pack holding , control chamber and watering mechanism involves following: a) Earth work excavation for foundation trenches in all kinds of soil, including dressing of sides and ramming of bottom with all leads and lefts. b) Cost in situ/ providing and laying of M20 (12 inch thick wall) grade cement concrete instone aggregate (quarry) including shattering, centering, removal ofshuttering and curing complete. (1.5 cum) c) Fab. P/grouting in above concrete work ISMC 100 angle iron frame of (10-0"x8"0") with side holding cleats. 10’x9 No, 4’x11 no’s, 4’x10 nos’ for vertical supports, ISA 50x50x5mm=40’ d)Fabrication, providing, fitting of top cover in four halves out of 8mm thick MS chequred sheet of 10’x8’ (2.5’x8’x4)for covering of the above gravel pack chamber and control valve chamber from the top including the cast of flushing hole for column pipe, lift holes for wire rope.The halves should be fixed with heavy duty hinges minimum 4 for each pieces. d) Painting by primary coat of red oxide steel primer and then black paint. (1 job) e) Proving and fitting of pressure guage at delivery line. f) Providing and fitting of water mechanism in PPR fitting for gravel g) Providing and filling of pea-gravel for production well. 200 Sft The above job executed at site by Shifting of desired tools, tackles & machinery done by skilled labor. |
228 | Fabrication of Transformer bed by way of : |
229 | Earth work excavation for foundation trenches in all kinds of soils, including dressing of sides, ramming of bottom, all leads and lifts involved. |
230 | Cost-in-situ/ Providing and laying M15 (1:2:4)grade cement concrete 20 mm nominal stone aggregate including carriage of material, form work , curing and loading to site complete for vertical posts & ladder main step |
231 | Fabrication / providing / fitting / grouting & allied jobs for transformer bed involves |
232 | Fabrication / providing & fitting of cable tray LT service line , cables up to controlling panel includes.Horizontal members of cable tray are to be fabricated by way of cutting welding & allied jobs out of ISA 35X 35 X5mm (total 20 m) & 25mmx5mm flat iron as resting members 20 no’s each 12 inch long, also included are fabrication of flower pot resting rings 4 no’s each 22 inch out of mentioned flat iron ISA 35X 35 X5mm - 20 m @ 2.6 kg / m = 52 Kgs. |
233 | Painting (double coat ) of the fabricated structure by two coats of enamel paint after one coat of red, shade approved by concerned engineer at site. |
234 | Fabrication, erection , and construction of overhead gantry for Transformer bed by way of: |
235 | Earth work/ Excavation of trenches by way of manual means, trenches for foundation for ISMB, the excavated earth to be disposed 15 m away from site all classifications of soil |
236 | Providing/ laying cement concrete in M15 1:2:4 mix 40 mm stone aggregate including form work and all carriages up to site, curing of concreting,. |
237 | Structural Steel:Fabrication , erection of gantry in MS fabricated out of MS Pipe for vertical support and ISMB 200 for horizontal supports Fabrication, providing and fitting of various steel structure for vertical/ horizontal Posts, horizontal belting , trusses ,plates etc. The job including cutting as per shape at site. Job is to be done by using skilled labour. |
238 | P/F of Mono rail for lifting 3MT load and is be fitted on ISMB200 for lifting transformer. |
239 | Providing of 3 ton chain pulley block one no (Pull lift/ indeff), with 6 m lift |
240 | Fabrication of canopy 3’x3’ size for chain pulley block fabricate out of ISA 40x40x4mm and CGI sheets (Green Shade) |
241 | Painting of steel structure with one coat of red oxide and two coats of paint with approved shade |
242 | Providing & Fitting of35 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting motors from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement .make phenolix/havells/KEI |
243 | Providing & Fitting of25 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting motors from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement .make phenolix/havells/KEI |
244 | Supply installation, testing & commissioning of 01 number 03 ton capacity chain pulley block having chain minimum lift of 6m with mono rail Make :Pull Lift/Indeff/globe . Complete with U. clamps, chain, hooks and other allied fixtures. Supply , installation , testing & Commissioning of 01 number 03 MT capacity electric hoist with minimum 6 m lift. Make: pull lift/ Indeff/ Globe. With monorail Complete with U clamp, chain hooks and other allied fixtures Fitting of 1.5’ long 50x50x5mm angle iron pieces for fabrication of ladder on one of the two vertical posts. Providing and finishing by anti- corrosion coating, buffing and two coats of painting of whole gantry with approved shade. |
245 | Gantry: a) P/F of 3-ton chain pulley block with Mono rail Pull Lift/ Indef make having lifting capacity of 6m. Complete with U. clamps, chain, hooks and other allied fixtures. 01 c uni b) P/fiting 3 ton capacy electric hoist rope hoist with monorail and all allied accessories like cable , control , MCB etc- 01 unit c) Providing and laying of M15 Cementconcrete 2 cum as per site requirement including exaction of earth for vertical supports. d) Fabrication / Erection of Channel iron column to act as support for resting of Chain Pully Blockwith Monorailas per following details:- Vertical Posts = ISMC 150 No. of vertical posts = 02 Nos. Vertical channel section each post= 02 Nos. vertical post bracing = ISMC 100 Sole / Matching plates = 500x300x12 mm Height of vertical posts = 4.5 M size of vertical post concrete blocks = 600x600x900mm Concrete grade = M20(as per requirement) welding Electrode = Overcord SS of Adore/ESAB/L&T Monorail Section = ISMB 200 length of monorail Chain Pully Block with monorail= 3 Ton= 5M |
246 | Providing & Fitting of35 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting VT motors from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement .make phenolix/havells/KEI |
247 | Providing, installation ,testing of power service cablefor workingvoltage up to and including 1100 volts;70 mm2 armored aluminum 3.5 core cable as service line from output terminals of HT/LT transformer / AVR to cubical panel. Cost includes laying of cable in trenches in Pvc conduit where ever itis to be laid underground as per site requirement included is termination of ends with suitable Aluminum tube terminals dully crimpled & taped. Make Gloster, Havells, Legend. |
248 | Scope: Design, manufacturing ,providing , fitting, testing & commissioning of Star-delta Motor control gear Panel for stage 1st The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Circuit Breaker incoming combined Type -----Front Operated micro processor release type on load 4 pole Qty ----- 2 Nos ( for Main and DG set Supply) Make ----- L & T / Schneider No. of poles ----- 4 Thermal relay range.------200A Rated operational voltage----- 415 V AC± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 50kA Type----- Microprocessor control b) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 200 Amp Make --------L & T / Schneider c) Change over Switch Qty ----- One Type ----- Front Operated on load 4 pole (open execution) Rating ----- 200 Amp Make ----- L&T/ Schneider d) Circuit Breaker units Type ----- MPCB (Type MOG-H2 (Rotary Type) - Frame 2) Qty ----- 2 Nos No. of poles------3 Make ----- L & T /Schneider Rated current -----150 Amp Thermal release range- Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----50kA e)Starters (FASD) Power Specification -----3 phase, 415± 15% v &50 Hz Contactors : MNX / Schneider Line Contactor -----AC3 90 A Delta Contactor --- AC390 A Star Contactor -----AC3 70A Contactor Make = L & T / Havells Timer ----- Star Delta Electronic Overload relay – direct/CT operated (10-45A range)/ available range Coil Voltage : 220/240V Qty ----- 2 No’s |
249 | f)Aux. panel Circuit breaker---MCCB Qnty---01 no. Make---L&T /Schneider No. of poles---04 Thermal release range -------63-80 A Rated operational Voltage---415+15% Ultimate S.C. Breaking Capacity---35 KA at (415AC,50 Hz) g)Stabilization unit Qnty---01 no Rating---- 1 KvA single phase automatic voltage stabilizer Input :90V-300 Out Put : 220/240 ( as per coil voltage of contractors) Enclosure--- to be housed within the cubical panel in separated chamber with additional meter , LEDfitted outer side Make : V-guard, microtec, luminious MCB DP ---10A----1nos h)ProtectionDetails: Motor Protection Relay including other related accessories like single phase preventer relay, timer relay , overload-under load, phase difference etc. Display -----LED/LCD and all setting is to be done at display Compact motor protection relay Qnty :01 nos) Make : L&T/ Schneider Protections : • Flush Mounting with display • Last trip data recording • Protections: - Thermal Overload with pre- alarm - Short Circuit - Earth fault - Phase loss, Unbalance, Phase reversal - Under Current - Prolong starting, Locked Rotor. -Single phase protection- Single Phasing condition- Phase Reversal condition- Phase Unbalance condition-Modes of Operation |
250 | i) Auxiliary Protection Earth Fault Relay -----3 phase Earth fault, ground fault module Type -----GF Range 100-200A MCB ----- MCB SP , 10A (10 Ka) Make : L&T/Schneider j) Water level controlrelay for including wiring and capsules required at site keepind depth of sump 10 meters in consideration: 01 unit complete g) Metering Details: • Incomers (Panel Mounted) (a) Multi-Function MetersLCD Display (1 No) Voltage of each phase , Current of each phase 3ø power (Active, Apparent) , 3ø Power factor Frequency, Energy (b) Analog voltmeter S/S operated (1 No) - Rishabh make. • (b) Outgoing (Analog voltmeter (0-500) S/S operated (1Nos) . Analog Ammeters 0-100 Amp(2Nos)for both starters Each outgoing with S/S CT operated (Rishabh make ) Note: Name of Scheme ; Allotment No ; should be imprinted on the machine with capital letters The job also includesproviding and fitting of MUG-50 FASD (starter-02 number(as standby arrangement) |
251 | Providing, installation ,testing of power service cablefor workingvoltage up to and including 1100 volts;50 mm2 armored aluminum 3.5 core cable as service line from output terminals of HT/LT transformer / to cubical panel. Cost includes laying of cable in trenches in Pvc conduit where ever itis to be laid underground as per site requirement included is termination of ends with suitable Aluminum tube terminals dully crimpled & taped. Makemake phenolix/havells/KEI |
252 | Design, manufacturing ,providing , fitting, testing & commissioning of Star-delta Motor control gear Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Circuit Breaker incoming combined Type -----Front Operated micro processor release type on load 4 pole Qty ----- 1 Nos Make ----- L & T / Schneider No. of poles ----- 4 Thermal relay range.------63-160 Rated operational voltage----- 415 V AC± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 36kA Type----- Microprocessor controlb) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 150 Amp Make --------L & T / Schneider c) Change over Switch Qty ----- One Type ----- Front Operated on load 4 pole (open execution) Rating ----- 200 Amp Make ----- L&T/ Schneider |
253 | Make : V-guard, microtec, luminious MCB DP ---10A----1nos h)ProtectionDetails: Motor Protection Relay including other related accessories like single phase preventer relay, timer relay , overload-under load, phase difference etc. Display -----LED/LCD Compact motor protection relay Note: all setting is to be controlledat display. Qnty :01 nos) Make : L&T/Schneider Protections : • Flush Mounting with display • Last trip data recording • Protections: - Thermal Overload with pre- alarm - Short Circuit - Earth fault - Phase loss, Unbalance, Phase reversal - Under Current, Over Load - Prolong starting, Locked Rotor. -Single phase protection- Single Phasing condition- Phase Reversal condition- Phase Unbalance condition-Modes of Operation i) Auxiliary Protection Earth Fault Relay -----3 phase Earth fault, ground fault module Type -----GF Range 100-200A MCB ----- MCB SP , 10A (10 Ka) Make : L&T/Schneider j) Metering Details: d) Circuit Breaker units Type ----- MPCB Qty ----- 2 Nos No. of poles------3 Make ----- L & T /Schneider Rated current -----100 Amp Thermal release range-28-60 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----36kA • Incomers (Panel Mounted) (a) Multi-Function MetersLCD Display (1 No) |
254 | e)Starters (FASD) Power Specification -----3 phase, 415± 15% v &50 Hz Contactors : MNX / Schneider Line Contactor -----AC3 70 A Delta Contactor --- AC370 A Star Contactor -----AC3 50 A Contactor Make = L & T / Havells Timer ----- Star Delta Electronic Overload relay – direct/CT operated (35-75A range) Coil Voltage : 220/240V Qty ----- 2 No’s f)Aux. panel Circuit breaker---MCCB Qnty---01 no. Make---L&T /Schneider No. of poles---04 Thermal release range -------63-80 A Rated operational Voltage---415+15% Ultimate S.C. Breaking Capacity---35 KA at (415AC,50 Hz) g)Stabilization unit Qnty---01 no Rating---- 1 KvA single phase automatic voltage stabilizer Input :90V-300 Out Put : 220/240 ( as per coil voltage of contractors) Enclosure--- to be housed within the cubical panel in separated chamber with additional meter , LEDfitted outer side Voltage of each phase , Current of each phase 3ø power (Active, Apparent) , 3ø Power factor Frequency, Energy (b) Analog voltmeter S/S operated (1 No) - Rishabh make. • (b) Outgoing (Analog voltmeter (0-500) S/S operated (1Nos) . Analog Ammeters 0-100 Amp(2Nos)for both starters Each outgoing with S/S CT operated (Rishabh make ) Note: Name of Scheme ; Allotment No ; should be imprinted on the machine with capital letters K)The job also includesproviding and fitting of MUG-30 FASD (relay range 20-33)starter-03 number(as standby arrangement) |
255 | Providing, installation, testing and commissioning of 50 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 50 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables |
256 | Providing, installation, testing and commissioning of 75 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 75 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables |
257 | Providing, installation, testing and commissioning of 100 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 100 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables |
258 | Providing, installation, testing and commissioning of outdoor type HT Trivectometer as per IEE Rule. Job includes grouting of legs in cement concrete as per site requirement. All cabling, earthing and allied accessories required to be provided by the firm. Moreover firm responsible for completing all sealing of PDDdepartment and testing on load and noload at site |
259 | Providing, fitting , installation , testing and commissioning of three phase ,40 KvA DG Set (Specification as per latest guide line) , 50 Hz , 415V, 0.8 (lag),1500 rpm, H class insulation ,water cooled , high tank capacity with acoustic enclosure, cabling required, battery, battery charger heavy duty, fuel storage arrangement 2 barrel additional with hand pump,pipe complete, earthing, AMC panel, construction of concrete base as per ruleminimum 3feet above ground and keeping HFL in consideration, Altitude-1610 AMSL, Job also includes providing and fitting of 90 m50 Sq mm Armoured 3.5 core Al Cable to be laid underground , lugs required . testing on load for minimum 5 hours and service free including first 3 moil change, filter change.Design, manufacturing ,providing , fitting, testing & commissioning of Main Control Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three |
260 | Design, manufacturing ,providing , fitting, testing & commissioning of Main Control Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor , Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Change over Switch Qty ----- Two ( one for phase reversal) Type ----- Front Operated on load 4 pole Rating ----- 200 Amp Make ----- L&T/Schneider b) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 200 Amp Make --------L & T /Schneider c) Circuit Breaker incoming combined Type ----- MCCB Qty ----- 2 Nos( one for DG Set, One for Mains) Make ----- L & T /Schneider No. of poles ----- 4 Thermal relay range.------200 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 36kA Type of release ----- Thermal Magnetic d) Circuit Breaker units Type -----MCCB Qty ----- 3 Nos No. of poles------4 Make ----- L & T /Schneider Thermal release range-150/160A Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----36kA |
261 | e)Circuit Breaker units (for illumination and for other related electrical ) Type -----MCCB(directly connected with the main MCCB ) Qty ----- 2 Nos No. of poles------2 Make ----- L & T / Schneider Thermal release range-100 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----10kA f) Earth Fault relay complete g) Metering Details: • Incomers (Panel Mounted) (a) Digital Voltmeter 01 No,L&T/Rishabh Make (b) Digital Ampere meter- 01 No L&T/Rishabh Make (c) Frequency meter-01 no L&T/Rishabh Make Selector switch with CT operated-02 nos to check Voltage & ampere for each phase incoming. Neon indicators for each phase Outgoing Digital Voltmeter 03 No,L&T/Rishabh Make Digital Ampere meter- 03 No L&T/Rishabh Make Each outgoing with S/S CT operatedL&T/Rishabh make ) and neon indicators for each phase |
262 | Providing and fitting of 60 W LED Street light (outdoor type) with angular stand fixture in MS/Steel. The LED should be environmental friendly long life versatile pressure dia cast aluminum IP67 roadway luminaires with high power LEDS as light source & exclusively designed polycarbonate cover along with electronic driver. The LED is to be controlled inside pump house and connected to the automatic voltage stabilizer through panel. The wire used should be2.5 sq mm multistranded two core 1100 volts pvc insulated copper conductor minimum 30 m for each connection through PVC pipe by way of p/f of MCB duly fitted on Bakelite phylum switch board with frame as per site requirement. Make havells , syska |
263 | Providing and fitting of 5 Kva Single phase automatic copper wound stabilizerfitted with digital meter .Job includes providing and fitting of cable input and output side. The job includes p/f of 16 A SS combine on inputside with 16 top.the said unit is used for illumination purpose and is to be connected with MCCB.. The name of water supply scheme is to be printed on top of the stabilizer. |
264 | Providing & fitting oflighting points for( machine room , operators room,) as per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulatedcopper conductor through pvcconduit pipe by way of p / f of pearl or non-ploy carbonate angle holders , pvc gang box, switches, socket modules , regulators ,indicators, 08/10 watt LED lamps Surface light Make(/Havells/Phillips/GM/syska). Make items Anchor, klick, S S K, Indo Asian, Philips, Havells .Included is cost on account of modular switch boards with the wooden frames as per site requirements |
265 | Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit by way of p / f of 15 Amp switches, 6 pin socketon modularfitting of Anchor, Philips, GM ,make as per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm. |
266 | Providing and fitting of 9” x 9”exhaust fan with complete wiring in 1.5 mm cu wire through conduit and 6 A modular controlcomplete job. Make havells , GM |
267 | Providing and fitting of ceiling fan make bajaj, havells, syska with complete wiring in 1.5 mm cu PVC insulated wire and fan regulator control on modular panel. Complete job. |
268 | Providing, fitting of Distribution Board of reputed make 4 way S P N single door powder coated sheet steel enclosure for surface mounting fitted with bus bar, DIN channel, neutral link and incoming contact. the above DB is to be provided /fitted with double pole 40 amp MCB for Main. 32 A for heating circuit & rest 3 of 16/6 amps each for premises luminary, auxiliary circuit 0f make indo Asian, Havells. Further job includes providing / fitting 4 mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit as service line from main panel as per site requirements. Connections should be made in such a way Lighting pointsis to be connected via automatic transformer by way of p/f switch socket arrangement with allied fixtures & and heating points to main panel. Job includes dismantling of existing damaged conduit , wires, conduit and cleaning the surface properly.one job at each stage |
269 | Providing of heavy duty tool kit Taparia make : Ring spanner of size 12-13,14-15,16-17,18-19,21-22,20-21,21-23,24-26,30-32 Plate Spanner of size12-13,14-15,16-17,18-19,21-22,20-21,21-23,24-26,30-32 Pipe wrench 36” & 14”one each, Plair -01 no. Screw driver set 01 set Providing of one no Heavy duty re- chargeable flash light. 01 no L-N Key – 1 set Providing of 04 no’s plastic chairs with one table of samrudhi make- 01 set Providing clamp type multi meter(AC/DC). make meco heavy duty -01 no’s Providing and fitting of link rod.-01 no Providing and fitting of shock proof matting 2x3 m 20 mm thick-6 no’s Providing and fitting of fire extinguisher 7.5 kgs for electric short circuit-02 no’s. |
270 | Constructing of Earthling station :Supply , installation , testing and commissioning of earthing electrode comprising of company fabricated earthing electrode as per IS :3043 for carrying out earthing . The job includes drilling / boring of 200 mm dia bore to the depth of 6 feet . Connectingthe cable tray through GI strips of suitable thickness besides making surface pit in brick / cement concrete of appropriate size. The earthing electrode shall be of 76/80mm dia and 1.83 mtr length of reputed make. The backfilling properly mixed compound as required . |
271 | Providing of four number good quality blankets,Two no’s good qualitymattress, quilts, pillows with covers for all. Two No. pressure cookers of 5 liters capacity (Hawkins make) 01, 3L pressure cooker -01, Bunton 3L-01 No. al/steel tea pan, 4 No. steel glass,4 cups, 4 steel plates, 4 no steel spoons, 1 steel jugs,2 no plastic jug, two number buckets ,14 L LPG Gas cylinder with regulator,pipe and two way gas topr, Electric cooking heater, 2 liters Collin ,dhoti cloth, 2 No. shook proof gloves, Bathroom broom, 2 No. brooms for room cleaning, 1 No. wiper,harpic.,.one no Heavy duty re- chargeable torch lantern led light. 04 no’s heavy duty link locks. |
272 | Providing, fitting , installation , testing and commissioning of three phase ,62.5 KvA DG Set (Specification as per latest guide line) , 50 Hz , 415V, 0.8 (lag),1500 rpm, H class insulation ,water cooled , high tank capacity with acoustic enclosure, cabling required, battery, battery charger heavy duty, fuel storage arrangement 2 barrel additional with hand pump,pipe complete, earthing, AMC panel, construction of concrete base as per ruleminimum 3feet above ground and keeping HFL in consideration, Altitude-1610 AMSL, Job also includes providing and fitting of 90 m50 Sq mm Armoured 3.5 core Al Cable to be laid underground , lugs required . testing on load for minimum 5 hours and service free including first 3 moil change, filter change. |
273 | Supply , installation ,t estingand commissioning of oil filled unbalanced sero voltage stabilizer of capacity 150 KW input working votage 156-470 and out 400 Volts PP- 230 PN, fitted with MCCB at input and out put side, digital meters, lugs, heavy duty tyre for easy movement, |
274 | Providing, fitting , installation , testing and commissioning of three phase ,30KvA DG Set (Specification as per latest guide line) , 50 Hz , 415V, 0.8 (lag),1500 rpm, H class insulation ,water cooled , high tank capacity with acoustic enclosure, cabling required, battery, battery charger heavy duty, fuel storage arrangement 2 barrel additional with hand pump,pipe complete, earthing, AMC panel, construction of concrete base as per ruleminimum 3feet above ground and keeping HFL in consideration, Altitude-1610 AMSL, Job also includes providing and fitting of 90 m50 Sq mm Armoured 3.5 core Al Cable to be laid underground , lugs required . testing on load for minimum 5 hours and service free including first 3 moil change, filter change. |
275 | Design, manufacturing ,providing , fitting, testing & commissioning of Star-delta Motor control gear Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Circuit Breaker incoming combined Type -----Front Operated micro processor release type on load 4 pole Qty ----- 1 Nos Make ----- L & T / Schneider No. of poles ----- 4 Thermal relay range.------63-160A Rated operational voltage----- 415 V AC± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 36kA Type----- Microprocessor control b) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 150 Amp Make --------L & T / Schneider |
276 | c) Change over Switch Qty ----- One Type ----- Front Operated on load 4 pole (open execution) Rating ----- 200 Amp Make ----- L&T/ Schneider d) Circuit Breaker units Type ----- MPCB Qty ----- 2 Nos No. of poles------3 Make ----- L & T /Schneider Rated current -----100 Amp Thermal release range-28-60 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----36kA e)Starters (FASD) Power Specification -----3 phase, 415± 15% v &50 Hz Contactors : MNX / Schneider Line Contactor -----AC3 70 A Delta Contactor --- AC370 A Star Contactor -----AC3 50 A Contactor Make = L & T / Havells Timer ----- Star Delta Electronic Overload relay – direct/CT operated (35-75A range) Coil Voltage : 220/240V Qty ----- 2 No’s f)Aux. panel Circuit breaker---MCCB Qnty---01 no. Make---L&T /Schneider No. of poles---04 Thermal release range -------63-80 A Rated operational Voltage---415+15% Ultimate S.C. Breaking Capacity---35 KA at (415AC,50 Hz) |
277 | g)Stabilization unit Qnty---01 no Rating---- 1 KvA single phase automatic voltage stabilizer Input :90V-300 Out Put : 220/240 ( as per coil voltage of contractors) Enclosure--- to be housed within the cubical panel in separated chamber with additional meter , LEDfitted outer side Make : V-guard, microtec, luminious MCB DP ---10A----1nos h)ProtectionDetails: Motor Protection Relay including other related accessories like single phase preventer relay, timer relay , overload-under load, phase difference etc. Display -----LED/LCD Compact motor protection relay Note: all setting is to be controlledat display. Qnty :01 nos) Make : L&T/Schneider Protections : • Flush Mounting with display • Last trip data recording • Protections: - Thermal Overload with pre- alarm - Short Circuit - Earth fault - Phase loss, Unbalance, Phase reversal - Under Current, Over Load - Prolong starting, Locked Rotor. -Single phase protection- Single Phasing condition- Phase Reversal condition- Phase Unbalance condition-Modes of Operation i) Auxiliary Protection Earth Fault Relay -----3 phase Earth fault, ground fault module Type -----GF Range 100-200A MCB ----- MCB SP , 10A (10 Ka) Make : L&T/Schneider |
278 | j) Metering Details: • Incomers (Panel Mounted) (a) Multi-Function MetersLCD Display (1 No) Voltage of each phase , Current of each phase 3ø power (Active, Apparent) , 3ø Power factor Frequency, Energy (b) Analog voltmeter S/S operated (1 No) - Rishabh make. • (b) Outgoing (Analog voltmeter (0-500) S/S operated (1Nos) . Analog Ammeters 0-100 Amp(2Nos)for both starters Each outgoing with S/S CT operated (Rishabh make ) Note: Name of Scheme ; Allotment No ; should be imprinted on the machine with capital letters K)The job also includesproviding and fitting of MUG-30 FASD (relay range 20-33)starter-03 number(as standby arrangement) |
279 | Providing, installation, testing and commissioning of split casing Horizontal pumping unit complete with AC induction squirrel cage prime mover as per following specifications: A. PUMP: 1. Type= Horizontal Shaft single or double suction, split casing type single or double volute. 2. Discharge = 6000 GPH 3. Head Range =25-40 meters range andat 32 m head discharge should be 4000 GPH 4. Liquid to be handled= Raw Water. 5. Impeller= Closed/ Semi open all bronze. 6. RPM= 1500/1470 7. Impeller Shaft= H.T.S.S. accurately machined protected by sleeve in gland 8. Bearing= Thrust/ roller/ ball bearing for both DE/NDE lubricated designed for duty to be performed. 9. Stuffing Box= Gland packed suitable for liquid to be handled. 10. Casing= CI preferably axially split/ volute type 11. Efficiency= Not less than 50% at duty point. 12. Make = Kirlosker/Wipl/M&P. B. PRIME MOVER: 1. Type=AC Squirrel cage induction motor SPDP/TEFC 2. Power supply= 415 ± 10%, volts 30 phase, 50 ± 5% Hz. AC 3. Efficiency = Not less than 85 % 4. Class of Insulation= B or F or above 5. H.P= Suitable for pump/ but not less than 12.5 HP 6. R.P.M= 1500 Syn. 7. Shall be confirming to latest ISS in voltage over a suitable period. C. Coupling= Flexible type coupling bored accurately and keyed to shafts designed for load. D. Base Frame= M.S fabricated sturdy for mounting above pump and motor designed for reqd. Load. E. Foundation= concrete base in M15 fitted withL/J type bolts and ISMC100 F. Make= Kirlosker/ ABB. G. Spare parts= Rubber bushes/ Washers for coupling 06 No’s reqd. size packing 2Kg. coupling set 01 No. |
280 | Providing, installation, testing and commissioning of split casing Horizontal pumping unit complete with AC induction squirrel cage prime mover as per following specifications: A. PUMP: 1. Type= Horizontal Shaft single or double suction, split casing type single or double volute. 2. Discharge = 10000 GPH 3. Head Range =25-50 meters range andat 40 m head discharge should be 10000 GPH 4. Liquid to be handled= Clear Water. 5. Impeller= Closed/ Semi open all bronze. 6. RPM= 1500/1470 7. Impeller Shaft= H.T.S.S. accurately machined protected by sleeve in gland 8. Bearing= Thrust/ roller/ ball bearing for both DE/NDE lubricated designed for duty to be performed. 9. Stuffing Box= Gland packed suitable for liquid to be handled. 10. Casing= CI preferably axially split/ volute type 11. Efficiency= Not less than 50% at duty point. 12. Make = Kirlosker/Wipl/M&P. B. PRIME MOVER: 1. Type=AC Squirrel cage induction motor SPDP/TEFC 2. Power supply= 415 ± 10%, volts 30 phase, 50 ± 5% Hz. AC 3. Efficiency = Not less than 85 % 4. Class of Insulation= B or F or above 5. H.P= Suitable for pump/ but not less than 20 HP 6. R.P.M= 1500 Syn. 7. Shall be confirming to latest ISS in voltage over a suitable period. C. Coupling= Flexible type coupling bored accurately and keyed to shafts designed for load. D. Base Frame= M.S fabricated sturdy for mounting above pump and motor designed for reqd. Load. E. Foundation= concrete base in M15 fitted withL/J type bolts and ISMC100 F. Make= Kirlosker/ ABB. G. Spare parts= Rubber bushes/ Washers for coupling 06 No’s reqd. size packing 2Kg. coupling set 01 No. |
281 | Fabrication , Providing , Fittingand testing of delivery manifold Y-junctionand suction system fabricated out of M S ( heavy class) 100mm dia pipes for delivery manifold and 80 mm dia MS pipe with bends for suction side fitted with 2 number 80 mm dia DI NRV’s VAG/AVK/Kirloskar make. The job also includes fabrication, providing and fitting of 100mm dia MS bends, including flanges, tabular flanges, increasers, reducers, nuts and bolts, gaskets as per site requirement. The job also includes p/f of 02 No’s 80 mm dia DI NRV PN 1.6 of VAG/AVK make and 02 No’s 80mm dia DI Sluice Valve PN 1.6 of VAK/AVK make. Job also includes fabrication frame in MS 8 mm thick sheet and ISAfor two number and as per side requirement . Job also includes painting of delivery manifold with one coat of red oxide and two coat of paint.(Colour as per direction of site engineer) . Thejob also includes fabrication providing and fitting of washout system in 100 mm dia MS Pipe (Heavy class) 18mts includingP/F fittingof 80 mm dia sluice valve 01 no, bends, offsets , flanges as per site requirement. |
282 | Fabrication , Providing , Fittingand testing of delivery manifold Y-junctionand suction system fabricated out of M S ( heavy class) 150mm dia pipes for delivery manifold and 100 mm dia MS pipe with bends for suction side fitted with 2 number 100 mm dia DI NRV’s VAG/AVK/Kirloskar make. The job also includes fabrication, providing and fitting of 100-150mm dia MS bends, including flanges, tabular flanges, increasers, reducers, nuts and bolts, gaskets as per site requirement. The job also includes p/f of 02 No’s 1500 mm dia DI NRV PN 1.6 of VAG/AVK make and 02 No’s 150mm dia DI Sluice Valve PN 1.6 of VAK/AVK make. Job also includes fabrication frame in MS 8 mm thick sheet and ISAfor two number and as per side requirement . Job also includes painting of delivery manifold with one coat of red oxide and two coat of paint.(Colour as per direction of site engineer) . Thejob also includes fabrication providing and fitting of washout system in 150 mm dia MS Pipe (Heavy class) 18mts includingP/F fittingof 150 mm dia sluice valve 01 no, bends, offsets , flanges as per site requirement. |
283 | Design, manufacturing ,providing , fitting, testing & commissioning of Star-delta Motor control gear Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor Cable Entry ----- Bottom Painting ----- Shade Siemens grey. a) Circuit Breaker incoming combined Type -----Front Operated micro processor release type on load 4 pole Qty ----- 1 Nos Make ----- L & T / Schneider No. of poles ----- 4 Thermal relay range.------63-160A Rated operational voltage----- 415 V AC± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 50 kA Type----- Microprocessor control b) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 150 Amp Make --------L & T / Schneider |
284 | c) Change over Switch Qty ----- One Type ----- Front Operated on load 4 pole (open execution) Rating ----- 200 Amp Make ----- L&T/ Schneider d) Circuit Breaker units Type ----- MPCB Qty ----- 2 Nos No. of poles------3 Make ----- L & T /Schneider Rated current -----100 Amp Thermal release range-28-60 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----36kA e)Starters (FASD) Power Specification -----3 phase, 415± 15% v &50 Hz Contactors : MNX / Schneider Line Contactor -----AC3 70 A Delta Contactor --- AC370 A Star Contactor -----AC3 50 A Contactor Make = L & T / Havells Timer ----- Star Delta Electronic Overload relay – direct/CT operated (35-75A range) Coil Voltage : 220/240V Qty ----- 2 No’s f)Aux. panel Circuit breaker---MCCB Qnty---01 no. Make---L&T /Schneider No. of poles---04 Thermal release range -------63-80 A Rated operational Voltage---415+15% Ultimate S.C. Breaking Capacity---35 KA at (415AC,50 Hz) g)Stabilization unit Qnty---01 no Rating---- 1 KvA single phase automatic voltage stabilizer Input :90V-300 Out Put : 220/240 ( as per coil voltage of contractors) Enclosure--- to be housed within the cubical panel in separated chamber with additional meter , LEDfitted outer side Make : V-guard, microtec, luminious MCB DP ---10A----1nos h)ProtectionDetails: Motor Protection Relay including other related accessories like single phase preventer relay, timer relay , overload-under load, phase difference etc. Display -----LED/LCD Compact motor protection relay Note: all setting is to be controlled at display. Qnty :01 nos) Make : L&T/Schneider Protections : • Flush Mounting with display • Last trip data recording • Protections: - Thermal Overload with pre- alarm - Short Circuit - Earth fault - Phase loss, Unbalance, Phase reversal - Under Current, Over Load - Prolong starting, Locked Rotor. -Single phase protection- Single Phasing condition- Phase Reversal condition- Phase Unbalance condition-Modes of Operation i) Water level controller complete assembly including capsules , wires, relays ia) Auxiliary Protection Earth Fault Relay -----3 phase Earth fault, ground fault module Type -----GF Range 100-200A MCB ----- MCB SP , 10A (10 Ka) Make : L&T/Schneider j) Metering Details: • Incomers (Panel Mounted) (a) Multi-Function MetersLCD Display (1 No) Voltage of each phase , Current of each phase 3ø power (Active, Apparent) , 3ø Power factor Frequency, Energy (b) Analog voltmeter S/S operated (1 No) - Rishabh make. • (b) Outgoing (Analog voltmeter (0-500) S/S operated (1Nos) . Analog Ammeters 0-100 Amp(2Nos)for both starters Each outgoing with S/S CT operated (Rishabh make ) Note: Name of Scheme ; Allotment No ; should be imprinted on the machine with capital letters K)The job also includesproviding and fitting of MUG-20H FASD starter-03 number(as standby arrangement) |
285 | Providing & Fitting of25 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting Electrical gadgets from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement .make phenolix/havells/KEI |
286 | Providing, installation ,testing of power service cablefor workingvoltage up to and including 1100 volts;70 mm2 armored aluminum 3.5 core cable as service line from output terminals of HT/LT transformer / to cubical panel. Cost includes laying of cable in trenches in Pvc conduit where ever itis to be laid underground as per site requirement included is termination of ends with suitable Aluminum tube terminals dully crimpled & taped. Makemake phenolix/havells/KEI |
287 | Providing, installation, testing and commissioning of 50 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 50 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. |
288 | Providing and fitting of single phase 1 Hp Open well submersible unit for filling of suction for horizontal motor along with complete fitting suction and deliveryin PPR fitting fitted with pumping unit, cabling and single phase starter complete |
289 | Providing and fitting of gantry system by way of providing and fitting of ISMB200 20’, longafter dismantling of existing cement concrete/brick wall and repair to same after fitment of ISMB200 , Providing and fitting of Mono rail 3MT indeff make , CP Block 3 MT indeff with 6m chain. Painting of the ISMB with one coat of red oxide and two coats of Golden yellowenamel paint. |
290 | Providing & fitting of 100mm dia flanged DI NRV , Make: VAG /AVK make (PN 16). Job includes two number table flanges connected to delivery pipe. Job also includes p/f of RI cloth with nuts and bolts. |
291 | Providing & fitting of 100mm dia flanged sluice valve , Make: Vag /AVK make (PN 16). Job includes two number table flanges connected to delivery pipe. Job also includes p/f of RI cloth with nuts and bolts. One for washout including tail pieces. |
292 | Providing, installation, testing and commissioning of 100 KVA Voltage Stabilizer of following specifications i. Range : 156V – 415 V i. Copper wound with adequate insulation and thickness suitable to the duty to be performed. ii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iii. Hysteresis loses to be minimum and temperature not to exceed 700 C. iv. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. v. Regulator to be of plate type with copper contacts cylindrical having six boosting steps. The contacts to be suitable to with stand over loading current at least double the rated current over considerable period of time. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. vi. The container at its top to be fitted with porcelain insulators for housing poles. vii. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The distance between the poles to be sufficient enough to accommodate the required size terminals to prevent arcing. viii. The container is be fitted with drain plug for T-oil near bottom & hooks at top for lifting top of the container by CP block at the time of repair works. ix. The top of the container to have a display panel for housing 02 numbers voltmeters0-500V (Rishab / AE Make) , square dial flush type along with 4 way selector switch and set of neon indicators both for input & output x. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. xi. Name of WSS ,Supplier & Allotment no& Date should be written on one side of body of Voltage Stabilizer. Rating : 100 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. |
293 | Providing, installation, testing and commissioning of split casing Horizontal pumping unit complete with AC induction squirrel cage prime mover as per following specifications: A. PUMP: 1. Type= Horizontal Shaft single or double suction, split casing type single or double volute. 2. Discharge = 14000 GPH 3. Head Range =25-50 meters range andat 40 m head discharge should be 14000 GPH 4. Liquid to be handled= Clear Water. 5. Impeller= Closed/ Semi open all bronze. 6. RPM= 1500/1470 7. Impeller Shaft= H.T.S.S. accurately machined protected by sleeve in gland 8. Bearing= Thrust/ roller/ ball bearing for both DE/NDE lubricated designed for duty to be performed. 9. Stuffing Box= Gland packed suitable for liquid to be handled. 10. Casing= CI preferably axially split/ volute type 11. Efficiency= Not less than 50% at duty point. 12. Make = Kirlosker/Wipl/M&P. B. PRIME MOVER: 1. Type=AC Squirrel cage induction motor SPDP/TEFC 2. Power supply= 415 ± 10%, volts 30 phase, 50 ± 5% Hz. AC 3. Efficiency = Not less than 85 % 4. Class of Insulation= B or F or above 5. H.P= Suitable for pump/ but not less than 20 HP 6. R.P.M= 1500 Syn. 7. Shall be confirming to latest ISS in voltage over a suitable period. C. Coupling= Flexible type coupling bored accurately and keyed to shafts designed for load. D. Base Frame= M.S fabricated sturdy for mounting above pump and motor designed for reqd. Load. E. Foundation= concrete base in M15 fitted withL/J type bolts and ISMC100 F. Make= Kirlosker/ ABB. G. Spare parts= Rubber bushes/ Washers for coupling 06 No’s reqd. size packing 2Kg. coupling set 01 No. |
294 | Design, manufacturing ,providing , fitting, testing & commissioning of Main Control Panel The Star-delta Motor control gear Panel shall be fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TP Aluminum Buses, complete with connection, internal wiring, neon indicators for each phase ,starter buttons, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel ----- 440 Volts Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Application ----- Indoor , Cable Entry ----- Bottom Painting ----- Shade Siemens grey. b) Change over Switch Qty ----- Two ( one for phase reversal) Type ----- Front Operated on load 4 pole Rating ----- 200 Amp Make ----- L&T/Schneider b) Distribution bus bar Type -----Electric grade AL with red, blue & yellow tapings Of adequate section. Rating ----- 200 Amp Make --------L & T /Schneider c) Circuit Breaker incoming combined Type ----- MCCB Qty ----- 2 Nos( one for DG Set, One for Mains) Make ----- L & T /Schneider No. of poles ----- 4 Thermal relay range.------200 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking cap at (415 volt A C , 50 Hz ) ----- 36kA Type of release ----- Thermal Magnetic |
295 | d) Circuit Breaker units Type -----MCCB Qty ----- 3 Nos No. of poles------4 Make ----- L & T /Schneider Thermal release range-150/160A Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----36kA e)Circuit Breaker units (for illumination and for other related electrical ) Type -----MCCB(directly connected with the main MCCB ) Qty ----- 2 Nos No. of poles------2 Make ----- L & T / Schneider Thermal release range-100 Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt A C , 50 Hz ) -----10kA f) Earth Fault relay complete g) Metering Details: • Incomers (Panel Mounted) (d) Digital Voltmeter 01 No,L&T/Rishabh Make (e) Digital Ampere meter- 01 No L&T/Rishabh Make (f) Frequency meter-01 no L&T/Rishabh Make Selector switch with CT operated-02 nos to check Voltage & ampere for each phase incoming. Neon indicators for each phase Outgoing Digital Voltmeter 03 No,L&T/Rishabh Make Digital Ampere meter- 03 No L&T/Rishabh Make Each outgoing with S/S CT operatedL&T/Rishabh make ) and neon indicators for each phase |
296 | Providing, fitting , installation , testing and commissioning of three phase ,30KvA DG Set (Specification as per latest guide line) , 50 Hz , 415V, 0.8 (lag),1500 rpm, H class insulation ,water cooled , high tank capacity with acoustic enclosure, cabling required, battery, battery charger heavy duty, fuel storage arrangement 2 barrel additional with hand pump,pipe complete, earthing, AMC panel, construction of concrete base as per ruleminimum 3feet above ground and keeping HFL in consideration, Altitude-1610 AMSL, Job also includes providing and fitting of 90 m50 Sq mm Armoured 3.5 core Al Cable to be laid underground , lugs required . testing on load for minimum 5 hours and service free including first 3 moil change, filter change. |
297 | Providing/fitting/testing/commissioning of power backup systems with pure sine wave home ups coupled with an inbuilt environmentally friendly zero maintenance tubular SMF VRLA gel batteries in a single console. The batteries should be sealed for life that is they should not have any requirement for water topping up or any spillage. The power bus should be equipped with a multi colored LCD user interface for better usage & monitoring. Technical specification. o Inverter rating = 850VA o Inverter Type = home UPS o Battery capacity = 150 Ah. o Battery Model = Tubular Type. o No Batteries = 01 No. o Output voltage at no load = 220+/-7 o Output frequency = 50 HZ +/- 1 o Output wave form = pure sine wave Make: Exide, Phillips, Microtek, luminous. Warranty:-UPS = 02 years ,Batteries = 03 years The combo unit is to be provided with warranty card for on door service during warranty period. Further job includes providing/fitting of separate circuit involving 2.5mm square multi stranded copper conductor form main auxiliary panel, 16 amp switch, socket separate modules, wooden blocks, hylum sheets, 03 pin top, earthing conductor from main earthing station, desired conduits, pvc channels & all allied items as per site requirement |
298 | Providing, installation, successful testing and commissioning of vertical turbine pumping unit driven by hollow shaft VT pumping unit of following parameters: • Site Condition: Altitude = 1580 Meters (AMSL) Ambient Temperature = +40°C to - 15°C Relative Humidity = 60% • Levels of site Bottom level of intake channel = Zero Meters Machine Floor level from bottom level of sump = 10 Meters • Type of water = Raw water having specific gravity of unity average • Quality of water = Raw water with silt having medium to coarse sand. A. PUMP 1. Discharge = 5000 GPH 2. Type = Self water lubricated, VT pump, open line shaft. 3. Liquid to be handled = Raw Water 4. RPM = 1460 5. Head = 170 Meters 6. Efficiency = Not less than 75% 7. Impeller = Enclosed/semi-enclosed mixed flow all bronze 8. Line shaft = Stainless steel 9. Impeller shaft = Stainless steel 10. Line shaft bearing = Cut less rubber/Neoprene rubber 11. Line shaft coupling = Stainless steel 12. Suction Strainer = MS fabricated 13. Suction Bowl/Bell mouth= Cast Iron 14. Pump Bowl = Cast iron 15. Column pipe = Mild Steel 150mm dia, anti- corrosive and polished, of wall thickness not less than 8mm flanged type in assorted lengths. At least 10 Meters column pipes to be provided. 16. Make = WPIL / Kirlosker / M&P Pump bowl to be designed with minimum number of stages. B. Prime Mover 1. Type = Vertical hollow shaft, AC induction 2. Power Supply = 03 Phase, 41 5V± 10% AC 3. Frequency = 50Hz±3% 4. RPM = 1450 Synchronous |
299 | 5. Efficiency = Not less than 85% 6. HP = Corresponding to Head and discharge but not less than 30 HP. 7. Class of insulation = F or above 8. Type of duty = Continuous 9. Motor thrust bearing = Anti-friction ball bearing 10. Make = Kirlosker / ABB / Siemens The motor should be able to with stand fluctuations in voltage and to be conforming the latest ISS specifications. C. Accessories Pumping unit shall be provided with motor stool discharge elbow, non-reverse ratchet, coupling, base frame fabricated of rolled steel beams ISMB-200 and chequered plate etc. as per standard specification. Besides all other accessories required for satisfactory performance of pumping units shall be provided, moreover cost of pumping set complete (VT pump/Electric motor/Accessories) as detailed above all told is inclusive of all taxes and duties state/central and carriage charges for delivery in the consignee"s stores/ site. Test certificates to be provided. The job includes necessary concreting and painting of the base frame by black paint in two coats after primary coat of red oxide. |
300 | Fabrication, providing, fitting of delivery manifold system out of 15 m of Heavy duty 5.4 mm thick 100 mm Dia. MS pipe at site with suitable no bends of required size/ pipe Spacer fabricated from said pipe, 18 mm thick flange, gaskets, screw fasteners as per pump diffuser size of the units to be installed and pipe being used as per site requirement. The system is to be designed to with stand pressure of 25 Kgf / cm2. The job also includes Supply of MS Clamps as per column pipe Dia. - 03 sets Pressure gauge Mechanism involving: (a) Welding of MS socket to above pipe spacer at the desired locations as per site requirement. (b) MS nipples as per site requirement- 6 Nos. (c) P/fitting of 03 no pressure gauge (0 to 25 kgf/ cm x cm) on the above welded MS nipple & gun metal ¾" ball Valve. (d) P/fitting of 02 No. 100mm dia. Sluice Valve of VAG/AVK/Sigma Flow Make. (e) P/fitting of 02 No. 100mm dia. Non Return Valve VAG/AVK/Sigma Flow Make. The quantity of the steel may vary as per site requirement as it is conditional to civil structures to be constructed. The job includes necessary painting by black paint in two coats after primary coat of red oxide. |
301 | Design, manufacturing ,providing , fitting, testing & commissioning of LT Control Starter Panel fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TPN Copper Buses, complete with connection, internal wiring, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel --440 Volts. Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Three phase Indication Lumps in Red, yellow &green Shades Application ----- Indoor. Cable Entry ----- Bottom Painting ----- Shade Siemens grey. Change over Switch Qty ----- One No Type ----- Front Operated on load “4 pole” Rating ----- 200 Amp Make ----- L&T/Schneider b) Distribution bus bar Type -----Electric grade “Cu” with red, blue & yellow tapings Of adequate section. Rating ----- 200 Amp Circuit Breaker incoming combined Type ----- MCCB 200 A D-Sine series Qty ----- 1 Nos Make ----- L & T No. of poles ----- 4 Breaking cap: at (415 volt A C , 50 Hz ) ----- 50 kA Type of release ----- Thermal release range [32-40]”A” Breaking cap: at (415 volt A C , 50 Hz ) ----- 50 kA Type of release ----- Thermal release range [32-40]”A” Auxiliary Circuit Breaker units for 3 nos. starters Type ----- MCCB Qty ----- 3 No’s No. of poles------3 |
302 | Make ----- L & T /Schneider Rated current -----200 Amp Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt AC, 50 Hz ) -----50 kA Starters Starters fitted with Single phase Protection relay arrangement [SPPR], Dual Analog voltmeter Cum Ampere Meters of Rishabh/L&T make of applicable range with Phase selector switch for Volt meter & ammeter. Type:- MUG-50 H Make = L & T Model = MUG 50 star / Delta Contactor= ML4 (wide band)Overload Relay=MN5 Relay Range= 45-75 A Pickup-up Voltage= 65% to 110% Uc Drop-off Voltage= 20% to 50%Uc Service Temperature= -5oC to + 55oC Qnty ----- Three Numbers Power Specification -----3 phase, 415 ± 15% v & 50 Hz. Backup HRC fuse=HF – 63A Switch Disconector fuse unit=FN 63:-Two No’s Aux. Cubical. One Auxiliary Cubical for use of auxiliary equipments of Pump House and premises like lightening/Heating with 63 amps 2 Pole MCB’s and Change over Switch. Circuit breaker---MCB Qnty---02 no. Make---L&T/Havells/Schneider No. of poles---02 Rated current---63 A Rated operational Voltage---220+15% Change over Switch Qty ----- One No Type ----- Two way centre off MCB Type 2 pole. Rating ----- 63 Amp Make ----- L&T/Havells Meter Module. Meter module comprising ofSeparate:- 1) Digital Volt-meter. 2) Digital ammeter. 3) Digital frequency meter.4) Digital power factor meter. 5) Digital Intelligent Panel meter which shall display line current in RYB phases, record and display trip counts and indicate trip status for over load, under load, single pahse, etc. The meter shall also analyse, display and record no. Of operations and duration of motor running. [All Components of L&T/Havells/Reputed make only confirming to ISI Specifications] |
303 | Providing, installation, testing and commissioning of 75 KVA Voltage Stabilizer with of following specifications: i. Range: 180 V – 415 V ii. Copper wound with adequate insulation and thickness suitable to the duty to be performed. iii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iv. Hysteresis loses to be minimum and temperature not to exceed 700C. v. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. vi. Voltage regulator switch to be of plate type with copper contact points having six boosting steps. The contacts to be suitable to withstand over loading current at least double the rated current over the considerable period of time. vii. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. viii. The container at its top to be fitted with porcelain insulators for housing poles. ix. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The creapage distance between the poles to be sufficient enough to accommodate the required size tube terminals to prevent arcing. x. The top of the container to have a display panel for housing 02 numbers voltmeters 0- 500V, square dial flush type along with 4 way selector switch and set of neon indicators. xi. Insulating media (T. Oil) of 11 KVA grade to be provided and filled with dielectric strength of 5 KV at 4m air gap. xii. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. Rating of stabilizer: 75 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. (The Voltage stabilizer to be manufactured in a registered workshop in presence of person authorized by the undersigned). The T-Oil of specific grade should be provided in a separate barrels. |
304 | Providing and fitting and testing of (06 no’s) lighting to the Operator Room with lighting points in 1.5 sq mm PVC insulated copper wire of Havells/Polycab including P/F of 10 Amp ON-OFF switches on Bakelite Sheet Modular Type, 12 watt LEDs of Havells/Syska/Philips Make and all other allied fixtures like Angle/Button Holder as required. The Job includes P/F of necessary PVC channels. The job includes cost of material and labour charges as well. |
305 | Providing/Fitting of Havells/Orient/Usha/CG make ceiling fan complete in all respects |
306 | Providing/Fitting of heating points Providing and fitting of (04 no’s)Heating Points to the operators roomin 4 sq mm PVC insulated copper wireof Havells/Polycab including P/F of 16 Amp SS Combine on Bakelite Sheet. The Job includes P/F of necessary PVC channels. The job includes cost of material and labour charges as well. |
307 | Providing /Fitting of 3-pin,5 Amp plug points complete in all respects. The 3-pin plugs has to be fitted along with Switchesin Modular Type Bakelite sheets. |
308 | Providing /Fitting of 16 way main distribution board of QVF Havells make with 10 Amp MCB-5 nos, 16 Amp-2 nos for heating points, 36 AMP MCB (mains) Havells make. |
309 | Service Line for Luminaries The cabling shall be of 2 Core, 10 mm Sq, PVC Insulated Al Cable (90 mtrs) (Havels/ABB/L&T) make. The Cabling shall have to be laid underground through a PVC conduit of suitable size and the job includes cost on account of earth excavation and back filling of the excavated soil after laying of the cable. |
310 | Cabling for Luminaries The cabling for luminaries shall be 4.0 mm Sq Cu wire (90mtrs) of standard quality (Havells/L&T/ABB) make in black and red as per ISI specifications. |
311 | FLOOD LIGHTS P/F of 48 Watt LED type street light assembly of Havells make (JETA Type) on GI 50 mm Dia. 3mm thick tabular pole/pipe having 5 meter height fabricated out of pipe 50 mm Dia. GI pipe with MS Plate to be welded at bottom. The Pole/pipe is to be erected in a trench 2.5 feet deep and then grouted in 1:2:3 C.C. block and the Top of the pole/pipe is to be bend at an angle of 135 degree for holding above light assembly by way of arm/holder arrangement. The Job includes Coating of pole with two coats of red oxide paint and one coat of enamel silver paint and P/f of 2 core 10 sq.mm armored al. cable up to control panel along with P/f of 16 amp MCB. The job includes providing of necessary wirings. |
312 | Power Inverter Providing and fitting of Power Inverter of 850VA Rating of Exide/Luminous/V-Guard Make including providing of 150 A Lead acid Battery Tubular Type complete in all respects. The job includes P/F of necessary plugs (SS Combine)- 2 nos. Socket for charging the inverter with necessary cable for incoming and outgoing power supply. |
313 | Providing & fitting of thermo coal along with Excel matting for operator’s room. Supplying of two number Quilts, two number Mattresses, two number pillows, two number Blankets, one no. blower for the employees in the operator’s room working during night shift. The job also includes providing & fitting of two number chargeable Light of Andeslite Make,& providingof4 number plastic chairs( Samrudhi / Neel Kamal, 01 number plastic table & crockery items/ utensilswith 05 kg gas cylinder as required for operators with all types of leads & carriages |
314 | Tool kit in a suitable box comprising of following tools (Taparia/JK Tools Make): - i. Ring spanner set of 12 pieces.-01 set. ii. Open ended spanner set of 12 pieces -01 set. iii. Pliers 8” -01 No. iv. Adjustable wrench -01 No. v. L.T. Line tester -01 No. vi. DigitalMultimeter -01 No. vii. Screw driver set starter type 01 set viii. Chisel type screw driver set -01 set ix. Hammer -01 No. x. Hacksaw frame with set of 6 blades. -01 No. |
315 | Providing, fabrication, erection, alignment, testing and commissioning of overhead Gantry consisting of 02 No. vertical posts fabricated out of MS pipe 200mm dia. and thickness of 6mm and height of 20’ for the lift of 6m required for chain pulley block. The two No. bases of vertical posts should be embedded in cement concrete blocks of mix M15 of size 1’6”x1’6”x1’. The base plates out of MS black plate of size 1’x1’ and thickness of 16mm to be fitted to the base and top of the vertical posts. Necessary holes to be drilled in the base plates and 16mm dia. anchors to be embedded in the concrete blocks. The horizontal beam out of ISMB-200 of length sufficient to go across the pump station walls, to be fitted above the top of the vertical posts properly aligned, fitted with nuts bolts and other required accessories like base plates and clamps to make it strong enough with required welding etc. to be carried with Adani/Spark electrodes. The Job also includes providing and applying of red oxide primer coat and two coats of synthetic enamel paint to whole overhead gantry. The Job also includes Providing, fitting, testing and commissioning of 3 MT chain pulley block with monorail, robust type heavy duty with minimum lift of 6m of heavy duty type Indef/Pull Lift/Globe make. The Job also includes P/F of Monkey Ladder fabricated out of angle iron 50x50x5mm at a distance of 1 feet provided and welded on one of the Vertical Posts for climbing up and down the vertical post for installation of the chain pulley block. |
316 | Providing, laying and testing of flat 3 core copper 16 sq mm submersible cable. The cable shall be PVC insulated and impermeable to grease, water and abrasion resistant. The job includes providing of copper thimblings as per requiremements. Make: Finolex/ Polycab/ Havells |
317 | Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 35 mm sq.copper cable forinternal distribution wiring. The multi-stranded copper cable to be laid through PVC conduits on wooden plain boards fixed on walls with suitable plugs, nails and clamps. The job also includes termination of ends of cable with suitable rating of Cu. thimbles duly taped. Make: Havells/ National/Standard/Plaza/Imperial/reputed make. |
318 | Providing, laying, installation and testing of 1.1KV, 3-1/2 Core, 95 sq. mm. Aluminum Conductor, PVC insulated, armored cable from distribution box of Transformer to the voltage stabilizer at both stages of the scheme. The Job also includes providing and installation of Aluminum thimbles of appropriate ratings (24 No.) duly crimped and taped. Make: Finolex/ Polycab/ Havells |
319 | Manufacturing, installation and commission of Energy Level 2, 100 KVA Level-II, oil cooled, three phase, outdoor type 11/0.433 KVA conventional (non-seated) type distribution, transformer shall have core type construction, suitable for outdoor system as stop down transformer. The primary winding shall be connected in the delta and secondary winding in star with symbol (DYLL). The neutral of separate insulated terminal. The core shall be built up of high grade chrome annealed silicon steel laminators having low loss and coated with firmly with channeled frame to prevent noise and vibrations. The LV winding shall be circular and concentric with HV winding on the outside. The arrangement of winding should be robust in elect./ mechanical construction and should permit free circulation of oil to avoid hot spots. Adequate bracing shell be provided so that a strong self-supporting coils is obtained, no tapes shall be provided in the Winding Electrical grade epoxy dotted or other suitable insulations both for LV and HV windings. The transformer tank shall be made out of MS Sheet of minimum thickness 3.15mm thickness for sides and 5m thicknesses for top and bottom plate, suitable to withstand extreme pressure conditions. Primary coating and two coats of enamel paint should be duly painted on the tank. The transformer shall have a conservator tank provided with a drain plum-filling hole with cover. The cover shall be with 75x49 mm channel, with holes to make them suitable for mounting on plate/ plinth. The transformer tank shall be fitted with new 11 KVA A-grade T-oil up to specific mark, the Earthing terminals, two lifting lungs, rating and terminal marking plate, bi-metallic terminal connection for High Voltage/ Low V voltage side bushing level gauge, breather, duly valve should be provided to the transformer. Test certificates to be provided. |
320 | Providing, installation, successful testing and commissioning of vertical turbine pumping unit driven by hollow shaft VT pumping unit of following parameters: • Site Condition: Altitude = 1580 Meters (AMSL) Ambient Temperature = +40°C to - 15°C Relative Humidity = 60% • Levels of site Bottom level of intake channel = Zero Meters Machine Floor level from bottom level of sump = 10 Meters • Type of water = Raw water having specific gravity of unity average • Quality of water = Raw water with silt having medium to coarse sand A. PUMP 1. Discharge = 5000 GPH 2. Type = Self water lubricated, VT pump, open line shaft. 3. Liquid to be handled = Raw Water 4. RPM = 1460 5. Head = 70 Meters 6. Efficiency = Not less than 75% 7. Impeller = Enclosed/semi-enclosed mixed flow all bronze 8. Line shaft = Stainless steel 9. Impeller shaft = Stainless steel 10. Line shaft bearing = Cut less rubber/Neoprene rubber 11. Line shaft coupling = Stainless steel 12. Suction Strainer = MS fabricated 13. Suction Bowl/Bell mouth= Cast Iron 14. Pump Bowl = Cast iron 15. Column pipe = Mild Steel 150mm dia, anti- corrosive and polished, of wall thickness not less than 8mm flanged type in assorted lengths. At least 10 Meters column pipes to be provided. 16. Make = WPIL / Kirlosker / M&P Pump bowl to be designed with minimum number of stages. B. Prime Mover 1. Type = Vertical hollow shaft, AC induction 2. Power Supply = 03 Phase, 41 5V± 10% AC 3. Frequency = 50Hz±3% |
321 | 4. RPM = 1450 Synchronous 5. Efficiency = Not less than 85% 6. HP = Corresponding to Head and discharge but not less than 15 HP. 7. Class of insulation = F or above 8. Type of duty = Continuous 9. Motor thrust bearing = Anti-friction ball bearing 10. Make = Kirlosker / ABB / Siemens The motor should be able to with stand fluctuations in voltage and to be conforming the latest ISS specifications. C. Accessories Pumping unit shall be provided with motor stool discharge elbow, non-reverse ratchet, coupling, base frame fabricated of rolled steel beams ISMB-200 and chequered plate etc. as per standard specification. Besides all other accessories required for satisfactory performance of pumping units shall be provided, moreover cost of pumping set complete (VT pump/Electric motor/Accessories) as detailed above all told is inclusive of all taxes and duties state/central and carriage charges for delivery in the consignee"s stores/ site. Test certificates to be provided. The job includes necessary concreting and painting of the base frame by black paint in two coats after primary coat of red oxide. |
322 | Fabrication, providing, fitting of delivery manifold system out of 15 m of Heavy duty 5.4 mm thick 100 mm Dia. MS pipe at site with suitable no bends of required size/ pipe Spacer fabricated from said pipe, 18 mm thick flange, gaskets, screw fasteners as per pump diffuser size of the units to be installed and pipe being used as per site requirement. The system is to be designed to with stand pressure of 25 Kgf / cm2. The job also includes Supply of MS Clamps as per column pipe Dia. - 03 sets Pressure gauge Mechanism involving: (a) Welding of MS socket to above pipe spacer at the desired locations as per site requirement. (b) MS nipples as per site requirement- 6 Nos. (c) P/fitting of 03 no pressure gauge (0 to 25 kgf/ cm x cm) on the above welded MS nipple & gun metal ¾" ball Valve. (d) P/fitting of 02 No. 80 mm dia. Sluice Valve of VAG/AVK/Sigma Flow Make. (e) P/fitting of 02 No. 80 mm dia. Non Return Valve VAG/AVK/Sigma Flow Make. The quantity of the steel may vary as per site requirement as it is conditional to civil structures to be constructed. The job includes necessary painting by black paint in two coats after primary coat of red oxide. |
323 | Design, manufacturing ,providing , fitting, testing & commissioning of LT Control Starter Panel fabricated out of 2 mm CRCA Sheets Modular, compartmentalized, Free Standing, Floor Mounting, Front hinged doors for indoor use, removable bottom gland plates for incoming cables, dust and vermin proof (IP: 42 protection) with TPN Copper Buses, complete with connection, internal wiring, name plates, painting ,vents etc. generally as per details furnished below: Rated Voltage of the Panel --440 Volts. Frequency ----- 50 HZ No of Phases ----- Three Enclosure Details ----- Free Standing, Floor mounted, Compartmentalized Design. Material ----- CRS Thickness of sheet steel used ----- 02mm Three phase Indication Lumps in Red, yellow &green Shades Application ----- Indoor. Cable Entry ----- Bottom Painting ----- Shade Siemens grey. Change over Switch Qty ----- One No Type ----- Front Operated on load “4 pole” Rating ----- 200 Amp Make ----- L&T/Schneider b) Distribution bus bar Type -----Electric grade “Cu” with red, blue & yellow tapings Of adequate section. Rating ----- 200 Amp Circuit Breaker incoming combined Type ----- MCCB 200 A D-Sine series Qty ----- 1 Nos Make ----- L & T No. of poles ----- 4 Breaking cap: at (415 volt A C , 50 Hz ) ----- 50 kA Type of release ----- Thermal release range [32-40]”A” Breaking cap: at (415 volt A C , 50 Hz ) ----- 50 kA Type of release ----- Thermal release range [32-40]”A” Auxiliary Circuit Breaker units for 3 nos. starters Type ----- MCCB Qty ----- 3 No’s No. of poles------3 Type ----- Two way centre off MCB Type 2 pole. Rating ----- 63 Amp Make ----- L&T/Havells Meter Module. |
324 | Make ----- L & T /Schneider Rated current -----200 Amp Rated operational voltage----- 415 V± 15% Rated frequency ----- 50± 3% Hz Ultimate S.C Breaking capacity at (415 volt AC, 50 Hz ) -----50 kA Starters Starters fitted with Single phase Protection relay arrangement [SPPR], Dual Analog voltmeter Cum Ampere Meters of Rishabh/L&T make of applicable range with Phase selector switch for Volt meter & ammeter. Type:- MUG-30 H Make = L & T Model = MUG-75 H star / Delta Contactor= ML4 (wide band) Overload Relay=MN5 Pickup-up Voltage= 65% to 110% Uc Drop-off Voltage= 20% to 50%Uc Service Temperature= -5oC to + 55oC Qnty ----- Three Numbers Power Specification -----3 phase, 415 ± 15% v & 50 Hz. Backup HRC fuse=HF – 63A Switch Disconector fuse unit=FN 63:-Two No’s Aux. Cubical. One Auxiliary Cubical for use of auxiliary equipments of Pump House and premises like lightening/Heating with 63 amps 2 Pole MCB’s and Change over Switch. Circuit breaker---MCB Qnty---02 no. Make---L&T/Havells/Schneider No. of poles---02 Rated current---63 A Rated operational Voltage---220+15% Change over Switch Qty ----- One NoMeter module comprising ofSeparate:- 1) Digital Volt-meter. 2) Digital ammeter. 3) Digital frequency meter.4) Digital power factor meter. 5) Digital Intelligent Panel meter which shall display line current in RYB phases, record and display trip counts and indicate trip status for over load, under load, single pahse, etc. The meter shall also analyse, display and record no. Of operations and duration of motor running. [All Components of L&T/Havells/Reputed make only confirming to ISI Specifications] |
325 | Providing, installation, testing and commissioning of 50 KVA Voltage Stabilizer with of following specifications: i. Range: 180 V – 415 V ii. Copper wound with adequate insulation and thickness suitable to the duty to be performed. iii. Core should be of cold rolled high silicon steel laminations held together with the help of steel clamps; material should be such that both magnetized currents and the core losses are minimum. The core laminations to be of minimum thickness but of adequate strength. iv. Hysteresis loses to be minimum and temperature not to exceed 700C. v. Air gap to be minimum to avoid Eddy formations for it the coils to be immersed in insulating varnish and dried by suitable means. vi. Voltage regulator switch to be of plate type with copper contact points having six boosting steps. The contacts to be suitable to withstand over loading current at least double the rated current over the considerable period of time. vii. The container to be sufficient to accommodate cores, windings, internal connections, and insulating media. Suitable cooling tubes to be provided along with oil level indicators. The container should be manufactured out of MS sheet of suitable thickness strong enough to withstand stresses produced by jacking and lifting. It should be provided with lifting lugs and should be duly painted form inside and outside. viii. The container at its top to be fitted with porcelain insulators for housing poles. ix. Seven numbers of brass poles to be fitted in the plate, three each for incoming and outgoing poles and one for neutral. The poles to be marked. The creapage distance between the poles to be sufficient enough to accommodate the required size tube terminals to prevent arcing. x. The top of the container to have a display panel for housing 02 numbers voltmeters 0- 500V, square dial flush type along with 4 way selector switch and set of neon indicators. xi. Insulating media (T. Oil) of 11 KVA grade to be provided and filled with dielectric strength of 5 KV at 4m air gap. xii. Steel Castor wheels to be fitted to the container at the bottom for easy positioning of the stabilizer. Rating of stabilizer: 50 KVA The job shall also include providing and fitting of suitable copper terminals dully crimped and taped to the incoming and outgoing cables. (The Voltage stabilizer to be manufactured in a registered workshop in presence of person authorized by the undersigned). The T-Oil of specific grade should be provided in a separate barrels. |
326 | Providing and fitting and testing of (06 no’s) lighting to the Operator Room with lighting points in 1.5 sq mm PVC insulated copper wire of Havells/Polycab including P/F of 10 Amp ON-OFF switches on Bakelite Sheet Modular Type, 12 watt LEDs of Havells/Syska/Philips Make and all other allied fixtures like Angle/Button Holder as required. The Job includes P/F of necessary PVC channels. The job includes cost of material and labour charges as well. |
327 | Providing/Fitting of Havells/Orient/Usha/CG make ceiling fan complete in all respects |
328 | Providing/Fitting of heating points Providing and fitting of (04 no’s)Heating Points to the operators roomin 4 sq mm PVC insulated copper wireof Havells/Polycab including P/F of 16 Amp SS Combine on Bakelite Sheet. The Job includes P/F of necessary PVC channels. The job includes cost of material and labour charges as well. |
329 | Providing /Fitting of 3-pin,5 Amp plug points complete in all respects. The 3-pin plugs has to be fitted along with Switchesin Modular Type Bakelite sheets. |
330 | Providing /Fitting of 16 way main distribution board of QVF Havells make with 10 Amp MCB-5 nos, 16 Amp-2 nos for heating points, 36 AMP MCB (mains) Havells make. |
331 | Service Line for Luminaries The cabling shall be of 2 Core, 10 mm Sq, PVC Insulated Al Cable (90 mtrs) (Havels/ABB/L&T) make. The Cabling shall have to be laid underground through a PVC conduit of suitable size and the job includes cost on account of earth excavation and back filling of the excavated soil after laying of the cable. |
332 | Cabling for Luminaries The cabling for luminaries shall be 4.0 mm Sq Cu wire (90mtrs) of standard quality (Havells/L&T/ABB) make in black and red as per ISI specifications. |
333 | FLOOD LIGHTS P/F of 48 Watt LED type street light assembly of Havells make (JETA Type) on GI 50 mm Dia. 3mm thick tabular pole/pipe having 5 meter height fabricated out of pipe 50 mm Dia. GI pipe with MS Plate to be welded at bottom. The Pole/pipe is to be erected in a trench 2.5 feet deep and then grouted in 1:2:3 C.C. block and the Top of the pole/pipe is to be bend at an angle of 135 degree for holding above light assembly by way of arm/holder arrangement. The Job includes Coating of pole with two coats of red oxide paint and one coat of enamel silver paint and P/f of 2 core 10 sq.mm armored al. cable up to control panel along with P/f of 16 amp MCB. The job includes providing of necessary wirings. |
334 | Power Inverter Providing and fitting of Power Inverter of 850VA Rating of Exide/Luminous/V-Guard Make including providing of 150 A Lead acid Battery Tubular Type complete in all respects. The job includes P/F of necessary plugs (SS Combine)- 2 nos. Socket for charging the inverter with necessary cable for incoming and outgoing power supply. |
335 | Providing & fitting of thermo coal along with Excel matting for operator’s room. Supplying of two number Quilts, two number Mattresses, two number pillows, two number Blankets, one no. blower for the employees in the operator’s room working during night shift. The job also includes providing & fitting of two number chargeable Light of Andeslite Make,& providingof4 number plastic chairs( Samrudhi / Neel Kamal, 01 number plastic table & crockery items/ utensilswith 05 kg gas cylinder as required for operators with all types of leads & carriages |
336 | Tool kit in a suitable box comprising of following tools (Taparia/JK Tools Make): - i. Ring spanner set of 12 pieces.-01 set. ii. Open ended spanner set of 12 pieces -01 set. iii. Pliers 8” -01 No. iv. Adjustable wrench -01 No. v. L.T. Line tester -01 No. vi. DigitalMultimeter -01 No. vii. Screw driver set starter type 01 set viii. Chisel type screw driver set -01 set ix. Hammer -01 No. x. Hacksaw frame with set of 6 blades. -01 No. |
337 | Providing, Installation, testing of multi-stranded copper conductor PVC insulated single core unsheathed 35 mm sq.copper cable forinternal distribution wiring. The multi-stranded copper cable to be laid through PVC conduits on wooden plain boards fixed on walls with suitable plugs, nails and clamps. The job also includes termination of ends of cable with suitable rating of Cu. thimbles duly taped. Make: Havells/ National/Standard/Plaza/Imperial/reputed make. |
338 | Providing, laying, installation and testing of 1.1KV, 3-1/2 Core, 95 sq. mm. Aluminum Conductor, PVC insulated, armored cable from distribution box of Transformer to the voltage stabilizer at both stages of the scheme. The Job also includes providing and installation of Aluminum thimbles of appropriate ratings (24 No.) duly crimped and taped. Make: Finolex/ Polycab/ Havells |
339 | Providing, laying and testing of flat 3 core copper 16 sq mm submersible cable. The cable shall be PVC insulated and impermeable to grease, water and abrasion resistant. The job includes providing of copper thimblings as per requiremements. Make: Finolex/ Polycab/ Havells |
340 | Providing, fabrication, erection, alignment, testing and commissioning of overhead Gantry consisting of 02 No. vertical posts fabricated out of MS pipe 200mm dia. and thickness of 6mm and height of 20’ for the lift of 6m required for chain pulley block. The two No. bases of vertical posts should be embedded in cement concrete blocks of mix M15 of size 1’6”x1’6”x1’. The base plates out of MS black plate of size 1’x1’ and thickness of 16mm to be fitted to the base and top of the vertical posts. Necessary holes to be drilled in the base plates and 16mm dia. anchors to be embedded in the concrete blocks. The horizontal beam out of ISMB-200 of length sufficient to go across the pump station walls, to be fitted above the top of the vertical posts properly aligned, fitted with nuts bolts and other required accessories like base plates and clamps to make it strong enough with required welding etc. to be carried with Adani/Spark electrodes. The Job also includes providing and applying of red oxide primer coat and two coats of synthetic enamel paint to whole overhead gantry. The Job also includes Providing, fitting, testing and commissioning of 3 MT chain pulley block with monorail, robust type heavy duty with minimum lift of 6m of heavy duty type Indef/Pull Lift/Globe make. The Job also includes P/F of Monkey Ladder fabricated out of angle iron 50x50x5mm at a distance of 1 feet provided and welded on one of the Vertical Posts for climbing up and down the vertical post for installation of the chain pulley block. |
341 | Construction of production tube well by way of a) Drilling/boring of Pilot hole:- The job includes drilling/boring of a pilot hole in all strata of soil/hard/rock/soft loose boulders etc upto adepth of max 150meters. The job shall have to be taken up strictly in accordance to the hydrological survey and report to be appended before the start of the work and exectution thereof. The type of well to be constructed shall be strictly in lightof the report and consent by the hydrologist expertise and report. The collection of water samples at the requisite spots/depth shall have to be collected by available means best suitable means to the firm as per site requirements. Then plastic boxes with proper labeling soil sample are to be collected in plastic boxes with proper labeling. The samples need to be deposited in the Divisional office for future reference. Specification a) Dia of Pilot hole :- 125mm B) Depth of pilot hole = < 150mtrs Max |
342 | b) Construction of Production Tube Well:-- After successful completion of the pilot hole an positive (within limits) water sample test report, the job is to be continued for construction of a full fledged production tube well at the same spot by way of the reaming/ODEX method (in case of hard rock strata if encountered to be decided by the hydrologist in consultation with the departmental expert) to the desired width/size. Broad band technical specification of the pilot hole and production well by and as required by the drilling procedure. 1) Production Well: a) Dia of production tube well=> 500/550mm b) Depth of Production well = < 120mtrs (May increase or decrease with condition of requirement report. Method type of Drilling/technique i) By D.C.M/R.C.M Mehod ii) By ODEX Mehod. The construction pruction tube well casing design and the positioning thereof shall be the full responsibility of firm/agency strictly as per the hydrologists report framed in consultation with the departmental expert/Engineer |
343 | Providing,Lowering and fitting of Heavy duty M.S casing pipe ERW as per relevant IS codes. The Jigs and fixtures for lowering the casing pipe are provided by the firm. Providing and fitting of Bail Plug/Bottom Plug ofvrequired dia t the bottom of the pipe aasly of the well |
344 | Providing and shrounding of Pea Gravel as per IS : 4097-1967 of assorted size around annual space between the casing pipe and the well surface has to be filled with a gravel pack to act as a filter medium. (Qunatity shall be subject to the actual measurements at site) |
345 | Development of Tube Well:- a) Development of Tube Well shall be done in accordance with IS 11189 - 1985. The job includes charges on accounts of complete development of the well after completion of drilling/boring and lowering of M.S Casing pipe and filling of pea Gravel if required (in Case of Artfical gravel pack). the compressor used should have pressure ratings of 1100 PSI with a delivery of 300 cfm. The job shell include cleaning and stablization of the well by inserting high compressed Air pressure to remove the suspended/strick/loose material from the casing and in the well bore surface. Development of well by compressor=04hrs/mtr of screen. The development has to be carried out in presence of the incharge site Engineer and as per the expertise advise consultant hydrologist if needed. Yield Test:- The job shell also include for carrying out yield test of the well by a submersible pumping unit of dsired capacity to be decided by the incharge Engineer. All other job"s which have not been specifically specified in the works shell have to be included as required and in accordance with relevant ISBS Codes. The grounting and sealing of tube well has be done to ensure |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy