}

Empanelment Of Eligible Contractors At Provincial Level And Fixing Of Item Rates For District Kulgam ( Qazigund / Kulgam Division ) Plain Lift Zone Group-4 For Execution Of Jal Jeevan Mission ( Jjm ) Works- 1 Earth Work In Excavation By M, Qazigund-Jammu And Kashmir

Public Health Engineering Department-PHED has published Empanelment Of Eligible Contractors At Provincial Level And Fixing Of Item Rates For District Kulgam ( Qazigund / Kulgam Division ) Plain Lift Zone Group-4 For Execution Of Jal Jeevan Mission ( Jjm ) Works- 1 Earth Work In Excavation By M. Submission Date for this Tender is 22-01-2022. Kitchen Equipment Tenders in Qazigund Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30108522
Corrigendum : Empanelment Of Eligible Contractors At Provincial Level And Fixing Of Item Rates For District Kulgam ( Qazigund / Kulgam Division ) Plain Lift Zone Group-4 For Execution Of Jal Jeevan Mission ( Jjm ) Works- 1 Earth Work In Excavation By M
Open Tender
Indian
Jammu And Kashmir
Qazigund
22-01-2022

Tender Details

Empanelment Of Eligible Contractors At Provincial Level And Fixing Of Item Rates For District Kulgam ( Qazigund / Kulgam Division ) Plain Lift Zone Group-4 For Execution Of Jal Jeevan Mission ( Jjm ) Works- 1 Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: 2 All Kinds Of Soil 3 Ordinary Rock 4 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) In Trenches For Foundations, Drains, Pipes, Cables Etc. ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres: 5 All Kinds Of Soil 6 Ordinary Rock 7 Earth Work In Bulk Excavation By Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 Mtr In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Upto 50 Mtrand Lift Upto 1.50 Mtr, As Directed By Engineer-In- Charge. 8 All Kinds Of Soil 9 Ordinary Rock 10 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) Over Areas ( Exceeding 30Cm In Depth, 1.5Mtr In Width As Well 10Sqm On Plan ) Including Disposal Of Exceveted Earth , Lead Upto 50M & Lift Upto 1.50 M Disposed Earth To Be Levelled & Neatly Dressed In Big Boulder Strata 11 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) In Foundion Tranches ( Exceeding 30Cm In Depth, 1.5Mtr In Width As Well 10Sqm On Plan ) Including Disposal Of Exceveted Earth , Lead Upto 50M & Lift Upto 1.50 M Disposed Earth To Be Levelled & Neatly Dressed In Big Boulder Strata 12 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) In Foundion Tranches ( Exceeding 30Cm In Depth, 1.5Mtr In Width As Well 10Sqm On Plan ) Including Disposal Of Exceveted Earth , Lead Upto 50M & Lift Upto 1.50 M Disposed Earth To Be Levelled & Neatly Dressed In Big Boulder Strata 13 Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. 14 Extra For Every Additional Lift Of 1.5 M Or Part There Of In Excavation / Banking Excavated Or Stacked Material. All Kinds Of Soil. 15 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 16 Dismantling G.I. Pipes ( External Work ) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually / By Mechanical Means Including Stacking Of Pipes Within 50 Meters Lead As Per Direction Of Engineer-In-Charge :Above 40 Mm Nominal Bore ( 65 / 50 Mm Dia G I Pipe ) 17 Laying And Fitting Of G.I. Pipes ( All Classes ) Complete Excluding Cost Of Pipes, Fittings And Earth Work. 18 80 Mm Dia. G.I. Pipes 19 65 Mm Dia. G.I. Pipes 20 50 Mmdia. G.I. Pipes 21 40 Mm Dia. G.I. Pipes 22 25 Mm Dia. G.I. Pipes 23 20 Mm Dia. G.I. Pipes 24 15 Mm Dia. G.I. Pipes 25 Laying In Position Centrifugally Cast Iron Pipes 26 150Mm Dia Di Pipes 27 Providing Push On Joints Todia Di Pipes 28 300 Mm Dia 29 200 Mm Dia 30 150Mm Dia 31 100Mm Dia 32 80 Mm Dia 33 Providing And Fixing Ms Flanges To Gi Pipes Including Cost Of Cutting Of Threaded Portion , Flanges, Welding , Nuts , Bolts, Rubber Washer And Carriage Etc Complete Job. 34 100Mm Dia G.I Pipes 35 80Mm Dia G.I Pipes 36 Providing And Fixing Sluice Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc. If Required Will Be Paid Separately ) . 37 100 Mm Dia. 38 80 Mm Dia. 39 Making Connection Of G.I. Distribution Branch With G.I. Main Offollowing Sizes By Providing And Fixing Tee, Including Cutting Andthreading The Pipe Etc. Complete 40 25 To 40 Mm Nominal Bore 41 50 To 80 Mm Nominal Bore 42 Provision For Providing And Fixing Ofcontrol / Regulator Valves At Various Spots / Pipe Specials If Not Supplied By Deptt. Store ( To Be Paid As Per Actual ) 43 Providing And Fixing Of 150Mm Dia.Sluice Valves With Tail Pieces Including All Carriage Complete. 44 Cutting Road And Making Good The Same Including Supply Of Extra Quantities Of Material I.E. Crushed Aggregate, Moorum Screening, Red Bajri And Labour Required. 45 Bituminous Portion 46 Water Bound Macadam 47 Providing And Laying Of Dry Stone Solling Tightly Hand Packed On Horizontal Levels 48 Dismentalling Of Cement Cvoncrate Manually / Mechnically Including Disposal Of Material Within 50M Lead In 1:3:6 Mix 49 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 50 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etc Upto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With. ( 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . 51 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 52 Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etc Upto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With. ( 1:3:6 ( 1 Cement : 3 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 53 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 54 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Includingcuring But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level. 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 55 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement Of Mix 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 56 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 57 Reinforced Cement Concrete Work In Arches, Archribs, Domes, Vaults Shells, Folded Plate And Roofs Having Slope More Than 15° Upto Floor Five Level Level Including Curing But Excluding The Cost Of Centering, Shuttering Finishing And Reinforcement With: 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 58 Brick Work With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 59 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level . 60 Dry Random Rubble Masonry With Hard Stone In Foundation And Plinth:With Bond Stone. 61 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above / Upto Plinth Level Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 62 Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 63 Structural Steel Work In Single Section, Fixed With Or Without Connectingplate, Including Cutting, Hoisting, Fixing In Position And Applying A Primingcoat Of Approved Steel Primer All Complete In Ladder . 64 Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-InCharge. Made Of G.I. Wire Of Dia 4 Mm 65 Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weightof Cement As Per Manufacturer’S Specification. ( 1 Kg Of Water Proofing Material In 50 Kg Of Cement ) 66 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 67 Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. 68 Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses Etc. 69 Suspended Floors, Roofs, Landings, Balconies And Access Platforms 70 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide. 71 Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 72 Columns, Pillars, Piers, Abutments, Posts And Struts. 73 Arches, Domes, Vaults Upto 6 M Span 74 Stairs 75 Extra For Shuttering In Circular Works ( 20 % Of Respective Quantity ) 76 Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. 77 Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses Etc. 78 Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 79 Extra For Arches, Domes, Vaults Exceeding 6 M Span 80 12Mm Cement Plaster Finishing With Floating Coat Of Neat Cement Of Mix 1 : 3 ( 1 Cement :3 Fine Sand ) 81 12Mm Cement Plaster Of Mix 1 : 4 ( 1 Cement : 4 Coarse Sand ) 82 12Mm Cement Plaster Of Mix 1 : 4 ( 1 Cement : 4 Fine Sand ) 83 6 Mm Cement Plaster Toof Mix 1 : 3 ( 1 Cement : 3 Fine Sand ) 84 Dewatering During Excution And All Stages Of Construction Complete Job 85 Cement Concrete Flooring 1:2:4 ( 1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 50 Mm Thick With 20Mm Nominal Size Stone Aggregate. 86 Supply Of Nallah Much Incld. Spreading Etc. Complete Job 87 Providing And Fixing 1St Quality Ceramic Glazed Floor Tiles Conforming Tois : 15622 ( Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 88 Providing Corrugated G. S. Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I. Limpet Washers Filled With White Lead, Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.50 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 89 Providing And Fixing Plained Eaves Boarding Of Ms Coloured Sheets 0.50Mm Thick 90 Providing And Fixing Of Ms Soffit Boarding Of Required Size As Per Dircetions Of Engineer In Charge. 91 Providing Ridges Or Hips Of Width 60Cm Overall Width Plain G.S. Sheets Fixed With Polymer Coated J. Or L Hooks, Bolts And Nuts 8Mm Dia G.I. Limpet And Bitumen Washers Complete. 0.50Mm Thick With Zinc Coating Not Less Than 275 Gram / M2. 92 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) Second Class Kail Wood 93 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge. ( Note: -Butt Hinges And Necessary Screws Shall Be Paid Separately ) . First Class Kail Wood 94 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge : . First Class Kail Wood 95 Providinghoisting And Fixing Trusses / Purlins / Rafters / Posts / Post-Plates Or Like Componentsincluding Cost Of Screws Etc. Completeist Class Popular Wood 96 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) . 97 Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete 1Mm Thick 98 Finishing Walls With Water Proofing Cement Paint Of Required Shade For New Work Two Or More Coats 99 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade On New Work ( Two Or More Coats ) Over And Including Priming Coat With Water Thinnable Cement Primer 100 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound ) Content. With Ready Mixed Pink Or Grey Primer On Wood Work ( Hard And Soft Wood ) Having Voc Content Less Than 50 Grams / Liter 101 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade.Two Or More Coats On New Work 102 Providing And Fixing Pvc Pipes For Weep Holes Along Retaining Wall 103 Provision For Instalation All Type Of Sanitary In Bath Room Including Water Storage Tank, 50 Ltr Gyser Etc Complete As Pert Direction Of Engineer Incharge At Site 104 Providing And Fixing Pvc Condusts Of Stsnadard Make For Electric Fitting Including Fitting Wire And Other Electric Installations Of Standard Make Including McbS And Main Control Panel Service Line ( Lighting Points 06 No Heating Points 04 No ) 105 Provision For Dismantling Of Existing Old And Damaged Pump Operator Quarter Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material As Per Deiection Of Engineer Incharge . The Dismantled Material So Retreved From The Structure Will Be The Property Of Executing Agency. ( Subject To Actual / Photographic Evidance ) 106 Providing And Supplying Matting Of Approved Quality In Two Layers As Approved By Engineer Incharge . 107 Providing And Fixing G.I. Pipes Complete With G.I. Fittings And Clamps, Including Cutting And Making Good The Walls Etc Concealed Pipe Including Painting With Anti Corrosive Bitumastic Paint, Cutting Chases And Making Good The Wall 108 15 Mm Dia. Nominal Bore 109 20 Mm Dia. Nominal Bore 110 Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) 111 20Mm Nominal Bore 112 Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) 113 15 Mm Nominal Bore 114 20 Mm Nominal Bore 115 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 116 Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or Strap, 10 Litre Low Level P.V. C. Flushing Cistern Including Flush Pipe ( Of Approved Make ) Manually Contro ( Led Device ( Handle Lever ) Conforming To Is:7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required. 117 Providing And Fixing Salem Stainless Steel A Lsi 304 ( 18 / 8 ) Kitchen Sink As Per I.S. 13983 With C.L. Brackets And Stainless Steel Plug 40 Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required: 19.10A1 Kitchen Sink With Drain Board 118 Providing And Fixing Soil, Waste And Vent Pipes : Pvc Type-B : 119 100 Mm Dia 120 75 Mm Dia 121 Provision For Providing And Fixing Bright Finished Brass Tower Bolts ( Barrel Type ) With Necessary Screws Etc. Complete. ( To Be Paid As Per Actual ) 122 Providing And Fixing Bright Finished Brass Handles With Screws Etc. Complete 123 100 Mm 124 75 Mm 125 Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. 126 Providing And Fixing Of 35 Ltr Capacity Geysers Of Venus, Racold Or Equivalent Including Fittings, And Complete Job 127 Providing And Fixing Chromium Plated Brass Curtain Rod Having Wall Thickness Of 1.25Mm With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Pvc Sleeves Etc., Wherever Necessary Complete :20 Mm Dia 128 Providing And Fixing Heating Points Using4.0 Mmthick Pvc Copper Wire Of Reputed Brand Including All Accessories 129 Providing And Fixing Of Lighting Points Inm 2.5 / 1.5Mm Pvc Copper Wire , Led Conical Type Of Handles / Syska Make Of 8 Watt Including Push Buttons Etc Complete Job. 130 Providing And Fixing Of Exhaust Fan In The Chemical House Complete Job. ( Havells, Usha, Crompton Greaves Make ) 131 Providing And Fixing Of Ceiling Fan In The Operating Room Complete Job. ( Havells, Usha, Crompton Greaves Make ) 132 Supply And Fixing Of Lightening Conductor Complete Job 133 Supply And Filling Excavated Earth Near Plinth Around Oht Etc Layeers Not Exceeding 20 Cm In Depth Cosolditing Each Deposited Layer By Remaining & Watering Including All Leads And Lifts 134 Carriage Of Material From Source To Dumping Site At Road By Mechanical Transport. 135 Cement & Steel For Avg. Lead Of15km 136 Sand For Avg. Lead Of25 Km 137 Sand For Avg. Lead Of20 Km 138 Sand For Avg. Lead Of15 Km 139 20Mm Aggregate For Avg. Lead Of 15 Km 140 40Mm Aggregate For Avg. Lead Of15 Km 141 Stone Solling / Quarry Stone For Avg Lead Of05 Km 142 Stone Solling / Quarry Stone For Avg Lead Of15 Km 143 Bricks10 Km 144 Timber 10 Km 145 100Mm Dia G.I Pipes15 Km 146 80 / 65 / 50 / 40 / 25 / 20 Mm Dia Gipipe15 Km 147 300Mm Dia Di 15 Km 148 200Mm Dia. 15 Km 149 150M M Dia Di Pipe15 Km 150 Carriage Of Material From Road Site Upto Actual Site Of Work By Manual Labour For Avg.Lead Of 350 Mtrs. 151 Cement 152 Steel 153 Sand And 20Mm Agg. 154 40Mm Aggregate 155 Stone Solling 156 Bricks 157 Timber 158 100Mm Dia G.I Pipes 159 80 / 65 / 50 / 40 / 25 / 20 Mm Dia Gipipe 15 Km 160 Extra Carriage Ofmaterial From Road Site Upto Actual Site Of Work By Manual Labour For Avg.Lead Of 500 Mtrs. 161 Cement 162 Steel 163 Sand 164 Aggregate 165 Bricks 166 Stone 167 80 / 65 / 50 / 40 / 25 / 20 Mm Dia Gipipe 168 300 Mm Dia D.I. Pipes 169 200 Mm Diad.I. Pipes 170 150 Mm Diad.I. Pipes 171 Extra Carriage Ofmaterial From Road Site Upto Actual Site Of Work By Manual Labour For Avg.Lead Of 100 Mtrs 172 Sand 173 Aggregate 174 Stonesoling 175 Cement And Steel 176 80 / 65 / 50 / 40 / 25 / 20 / Mm Dia Gipipe 500 Mtr 177 150Mm Dia D.I 178 100Mm Dia G.I 179 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unitas Per Is 8034 With Following Specification Are As Under :Pump : Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermotor:-Method Ofstarting = Star – Deltaspeed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage= 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90%Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. Detailed Specifications As Per Cluase 1 Sbdthe Mainspecicifications Of Pumping Unit Are Given Below: 180 Motor Rating 12.5 Hp 181 Motor Rating 25 Hp 182 Fabrication, Providing, Fitting And Lowering Of 65 / 80 / 100 Mm Diameter B Class ( Medium Class ) Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Up To The Desired Depth ; The Job Includes Providing And Welding Of Flanges Conforming Tois: 6392, Table-5 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Weld On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange. 183 Size: Dn 65Class: B ( Medium ) 184 Size : Dn 80Class: B ( Medium ) 185 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-B / C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) .S. The Rising Main Is To Be Laid As Per The Instructions Of The Engineer In Charge And Site Requirement And Details As Per Cluase 8 Of Sbd 186 Size : Dn80class: B ( Medium ) 187 Size : Dn100class: C ( Heavy ) 188 Earth Work In Excavation By Manual Means In Trenches For Foundation , Drains , Pipes , Cables ( Not Exceeding 1.5 M In Width ) And For Shafts , Wells , Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed. 189 All Kinds Of Soil 01 Meter From Cutting Edge 190 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M. 191 Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materialin All Kinds Of Soil 192 Providing And Laying Of Stone Soling Including Manual Compaction 193 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 194 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2 : 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 195 12 Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement , 4 Fine Sand ) 196 Fabrication, Providing And Fitting Of Split Type Ms Clamps10 Mm Thick, 2 Ft Long And 3 Inch Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 197 Size: 65 / 80Mm 198 Fabrication , Providing And Fitting Of90-120 Degree Long Bend To Be Fabricated Out Ofg.I Pipe And Flanged On Both Ends Ato Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement.Specifications As Per Clause 15 Of Sbd 199 Size:Dn 80Class: C 200 Size:Dn 100Class: C 201 Providing And Fitting Of 300Mm In Length 80 / 100-65 Mm Dia Gi Reducer Bend Flanged On Both Sides, Flange Conforming To Table-17 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising-Main And Column Pipe / Delivery Manifold. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint. 202 Size:Dn 80Class: C 203 Size:Dn 100Class: C 204 Fabrication, Providing And Fitting Of Washout Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. 205 Size: 80Mmclass: C Class 206 Size: 100 Mmclass: C Class 207 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 12Of Technical Anexure Of Sbd 208 Size 80 Mmpn1.6 209 Size100 Mmpn1.6 210 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size 80 Mm Pn 1.6Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 13Of Technical Anexure Of Sbd 211 Size: 80Mmpn: 1.6 / 16 212 Size: 100Mmpn: 1.6 / 16 213 Fabrication Of Gravel Hooper For Proper Feeding Of Gravels To The Borewell Andplatform To Bear The Load Of Pumping Unit, Column Pipes Etc By Way Of Providing And Fitting Of Steel Work Welded In Built Up Sections / Framed Work , Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required. The Job Involves Following Steel Details: 214 In Stringers , Treads , Landings Etc Of Stair Cases Including Use Of Chequered Plate Wherever Required , All Complete 215 In Grating , Frames , Guard Bar , Ladder , Railings, Brackets, Gates And Similar Works 216 Providing And Fitting Ofm.S 4 Inch Hinges -6 No And M.S Handle Heavy -8No., Anchor Bolts With Nuts ( M16 ) Of 0.3 M Long= 04 No. Metallic Strip ( 350Mm×50Mm×3Mm ) = 02 No. 217 Fabrication Of Gantry Mechanism / Cgi Shed / Angle Iron Bed By Way Of Providing Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded. 218 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 219 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features : Make= Reputed Make No. Of Load Chain Falls = 2 Or Abovemin. Height Of Lift = 6 M Manufacture Test Certificate To Be Appended. Rest Ofspecification As Per Cluase 24Of Technical Anexure Of Sbd 220 Capacity =2Ton 221 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories As Per Technical Specification Mentioned In Nit 222 Fabrication, Providing And Fitting Ofmodularmotor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories As Mentioned In Technical Specification In Nit 223 Providing, Fitting, Testing And Commissioning Ofvoltage Stabilizeras Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supplyrest Technincal Specification As Per Cluase 45 Of Sb 224 Rating:30Kva 225 Rating:50Kva 226 Providing And Fitting Of 3-Core Flatsubmersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipments . The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. 227 Size: 10Sq.Mm 228 Size: 16Sq.Mm 229 Providing And Fitting Of 3.5 Core, Xlpe Armoured Aluminium Cable Conforming To Is: 7089 Part 1St As Service Line From The Ht Transformer / Dg Set To Control Panel Including Necessary Thimbling, Crimping, Taping Etc.Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Al. Thimbles Of Appropriate Size And Connected By Hydraulic Crimp Tool Only. 230 Ii ) 50Sqmm, 3.5 Core Lt 1.1 Kv 231 Providing And Fitting Of Single-Core, Copper Pvc Insulated Cable, Conforming To Is: 694 Part 1St For Internal Connections With Crimping, Taping Etc Note:- The Cable Terminal Ends For Connection To Switchgear At Various Requisite Points Shall Be Copper Thimbled And Of Appropriate Size And Connected By Hydraulic Crimp Tool Only. 232 Single Core Pvc Insulated 16 Sqmm 233 P / I Of Earthing Station For Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size:80 Mm Dia , Length :2000 Mmback Fill Compound :30 Kg 234 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is:15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . Rest Technical Specification As Per Cluase 50 Of Sbd 235 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items.1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp. Rest Technical Specification As Per Cluase 51 Of Sbd 236 Providing Laying And Connection Of 2Cx10 Mm² Xlpe Aluminum Armored Cable From The Connector Of High Mast Pole To The Stabilizer. The Job Includes Underground Laying Or Overhanging As Per Requirement And Directions Of The Site In-Charge. 237 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole . Rest Technical Specification As Per Cluase 52 Of Sbd 238 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70-240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site Incharge. 239 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Amaron / Exide ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 240 Supply, Installation, Testing & Commissioning Of 850Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) 241 Supply, Installation, Testing & Commissioning Of 850Va Full Sine Wave Power Inverter ( Make: Microtek / Luminous ) Including Providing / Installation Of 12V, 150Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Amaron / Exide ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 242 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 243 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise All The Items As Per Cluase 57Of Technical Anexure Of Sbd With Laid Down Specifications. 244 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 245 Providing Of Good Qualityconvence And Utility Items. Technical Specification And Item Details Are As Per Cluase 58 Of Sbd. 246 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 247 Providing Of Bamboo Ladders 18 Feet Long Along With 15 / 18 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 248 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 249 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Names Of Water Supply Scheme And The Department. Size:6’×1’6” 250 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 251 Providing Ridges Or Hips Of Width 60 Cm Overall With Plain G.S Sheets Fixed With Polymer Coated J- Or L- Hooks , Bolts And Nuts 8 Mm Dia. G.I Limpet And Bitumen Washers Complete 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gram / Sq.M 252 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments.Manufacturers Certificate To Be Apended And Rest Of Technical Specification As Per Cluase 67 Of Sbd 253 Rating: 25Kva , Air Cooled. 254 Rating: 40 Kva , Air Cooled. 255 Fabrication Ofcgi Angle Iron Shed And Bed 256 Drilling / .Boring Of Pilot Bore Hole: The Job Includes Drilling / Boring Of A Pilot Hole In All Types Of Strata Of Soil I.E. Hard Rock / Soft / Loose Boulders Etc Upto A Depth Of Max 150 Metres. The Job Shall Have To Be Taken Up Strictly In Accordance With The Hydro-Geological Survey And Repogtis To Be Appended Beforethe Start Of Thework. The Collection Of Water Samples / Soil Samples At The Requisite Depth, Shall Have To Be Collected By Available Means In The Best Possible Manner, As Per Site Requirements. The Soil Samples Need To Be Deposited In The Divisional Office For Future Reference. Specificationsa ) Dia Of Pilot Hole >= 125B ) Depth Of Pilot Hole <= 140 Mtrs Max. 257 After Successful Completion Of The Pilot Bore And Positive ( Within Limits ) Water Supply Test Report, The Job Is To Be Continued For Construction Of A Full-Fledged Production Tube Well At The Same Spot By Way Of The Reaming / Odex Method ( In Case Of Hard Rock Strata If Encountered: To Be Decided By The Hydro-Geologist In Consultation With The Departmental Experts ) To Be Desired Dia / Size. Broad Technical Specification Production Well By And As Required By The Drilling Procedure. A ) Dia Of Production Tube Well >= 500 / 550 Mmb ) Depth Of Production Well <= 120 Mtrs ( May Increase Or Decrease As Per The Site Conditionsand Hydro-Geological Reports. Browserin Case No Case The Depth Shall Be Allowed Beyound 150 Meters Depthmethod Type Of Drilling / Technique I ) By Dcm / Rcmii ) By Odex Methodthe Construction Of Production Tubewell, Casing Design And The No. Of Screen.Slottedpipes Or Length Of Each Screen And Positioning Thereof Shall Be The Full Responsibility Of Firm / Agency Which Should Be Strictly As Per The Hydro-Geologist;S Report Framedin Consultation With The Departmental Expert / Engineer 258 Lowering And Fittingof Heavy Duty M.S. Casing Pipe Erw / Few As Per Relevant Is Codes. The Jigs And Fixtures For Lowering The Casing Pipe Are To Be Provided By The Firm. Providing & Fitting Of Bail Flug / Bottom Flugof Required Dia As Per The Relevant Is Codes, At The Bottom Of The Pipes Assly Of The Well. The Pipe Is To Be Provided By The Department 259 Providing And Shrouding Of Pea Gravel As Per Is : 4097 -1967Of Assorted Size Around Annular Space Between The Casing Pipe And The Well Surface Has To Be Filled With A Gravel Packto Act As A Filter Medium ( Quantity Shall Be Subject To The Actualmeasurements At Site ) 260 Developmentof The Well Should Be Strictly Be Done In Accordance To Is :1189-1985. The Job Includes Charges On Accounts Of Complete Development Of The Well After The Completion Of Drilling / Boring And Lowering Of M.S Casing Pipe And Filling Of Pea Gravelif Required ( In Case Of Artifical Gravel Pack ) . The Compressor Used Should Have Pressure Ratings Of 1100 Pso With A Delivery Of 300 Cfm. The Job Include Cleaning And Stabilization Of The Well By Inserting High Compressed Air Pressure To Remove The Suspended / Stick Loose Material From The Casing And In The Well Bore Surface. Development Of Well By Compressor = 04 Hrs / Mtr Of Screen. The Development Has To Be Carried In Presence Of In Charge Site Engineer And As Per The Expert Advice Of Consultant Hygro-Geologist If Needed. Yield Test:- The Job Shall Also Include For Carryingout Yieldtest Of The Well By The Submersiblepumping Unit Desired Capacity To Be Decided By The In Charge Engineer. All Other JobS Which Have Not Been Been Specifically Specified In The Works Shall Have To Be Included As Required And In Accordance With Relevant Isbis Codes. The Grouting & Sealing Of The Tube Well Needs To Be Done To Ensure Safe Sanitary. An Apron Aroundthewell ( Mix Shall Be M10 Grade ) & Slopping Away From It To Protect The Well From Pollution Has To Be Constructed To Prevent Contaminated Water Flowing Back Into It. The Casing Pipe Is To Be Anchored Within The Apron By Welding Ismc-190 Stell Bracing With Crates & Sufficientwelding Area2 Mtslength Each Bracing Embedded Within The Apron ( 4 Bracing ) . The Complete Well Thus Is To Be Handed Over To The Territorial Mechanical Division For Harnessing. Technical Specifications .Minimum Run For Compressor ......... 04 Hrs / Mtr Of Screen Yield Test For Water ( Till Desired Results ) ..... Min 30 Hrsi Apron Size = 2.5 Mtr X 2.5Ii. Apron Depth At Skirt = 300 Mm. Iii Apron Depth At Well Casing = 350 Mm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Dec-2021 Corrigendum Technical Bid 31-12-2021
2 01-Jan-2022 Extension I Date 11-01-2022
3 11-Jan-2022 Extension II Date 22-01-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 75000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail