}

Supply, Installation, Testing, Commissioning, Operation And Maintenance ( For 03 Years ) Of Electro-Mechanical Equipments At Wss Poshpathri Khonmoh-2 Supply, installation, testing and commissioning ofSubmersible pumping units of following s, Srinagar-Jammu And Kashmir

Public Health Engineering Department-PHED has published Supply, Installation, Testing, Commissioning, Operation And Maintenance ( For 03 Years ) Of Electro-Mechanical Equipments At Wss Poshpathri Khonmoh-2 Supply, installation, testing and commissioning ofSubmersible pumping units of following s. Submission Date for this Tender is 15-12-2021. Kitchen Equipment Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30108407
Corrigendum : Supply, Installation, Testing, Commissioning, Operation And Maintenance ( For 03 Years ) Of Electro-Mechanical Equipments At Wss Poshpathri Khonmoh-2 Supply, installation, testing and commissioning ofSubmersible pumping units of following s
Open Tender
Indian
Jammu And Kashmir
Srinagar
15-12-2021

Tender Details

Supply, Installation, Testing, Commissioning, Operation And Maintenance ( For 03 Years ) Of Electro-Mechanical Equipments At Wss Poshpathri Khonmoh-2 Supply, installation, testing and commissioning ofSubmersible pumping units of following specifications to be installed in the sump conforming to IS : 8034:2002 :-PUMP:-Discharge :- 4000GPH Head:-102Mtrs Speed : 2900 rpm Type of pump:submersibleQuality of water to be handled:-Clear Water The material of construction for pump, bearings, sleeves, casing, wear rings, pump shaft and suction casing shall suit to handle specifications detailed above.MOTOR Type :- Submersible Rating : Suitable for above parametersMethod of starting : Star Delta Speed: - 2900 rpmVoltage : 415 V + 15 % Class of Insulation : Suitable for above ratingThe pumping equipment has to be installed in the bore well of dia 250mm. The submersible motor shall be squirrel cage induction type and the winding shall be wet type. The motor windings and bearing bushes of the rotary shall be cooled / lubricated by water. The unit shall be provided with name plate giving following details / information.Name of the manufacturer or trade markSerial No. Of the pump setTotal head and dischargeInduction motorFrequency in HzNumber of phasesRated output in KW / HPRated voltage and including connectionsSpeed in revolutions per minute at rated outputApprox. current in Amps at rated outputThe pumping unit shall be provided with allied accessories / attachments viz. MS strengthening clamp, coupling etc for each unit. One number unit to be installed in the well and two to be kept as standby.The item shall be supported with test certificate, performance characteristic curve and material of construction certificate from original Equipmentmanufacturer. 3 Supply/Fabrication and fitting of suitable size GI nipples for pumps. The nipples shall be threaded on one side as per outlet of pump and welded with suitable size MS flange as per the size of rising main including 2 number of MS clamps as per pipe size, with nuts and bolts. 4 Fabrication, Providing, Fitting & lowering of column pipe of 80 mm NB (Class-B) Flanged GI Pipe, confirming to IS 1239, 2005 part 1 (with latest amendments) each of 10 Rft length. The M.S Flanges shall conform to BIS 6392-1971, relevant Table 5. The flanges shall be welded in double layers with reputed make electrode having dia. Not less than 4mm. The job includes P/& screwing the nuts bolts (M-16) size (as per IS: 1363 Part Ist) and Rubber Insertion Gaskets (as per IS: 638/79) to be used between flanged joints of column pipes. The job also includes providing and fitting of offsets, bends for connecting column pipe with rising main up to the sump as per the site requirement. The acceptable makes for the pipe shall be of reputed make. Flange should be grooved for cable, so that cable does not get damaged. 5 P/F of 16 sq. mm, submersible cable reputed make for open well submersible pumping equipment from panel in the pump house to sump. 6 Fabrication / Providing / Fitting and testing of Modular control panel of appropriate size fabricated out of 14 SWG steel sheet having required openings / vents and fitted with accessories as under as per I&C 60947:2020:-Change over switch : Front operated / On load / 04 pole Rating: 200 Amp / 415 V + 15 % , 50 Hz + 3 % Quantity: One NoMain Circuit breaker : MCCB Thermal release range ( Amp ): 160 – 200 Breaking Capacity: Icu at 415 V AC, 50 HZ : 50 KA No of poles : 04Type: DN2 – 100N Qty : 01 NoCircuit Breaker on the input of starters : MCCB Thermal release range ( Amp ): 100 – 125 Breaking Capacity: Icu at 415 V AC, 50 HZ : 36 KA No of poles : 03Type: DN2 – 100D Qty : 02 NoStarter ( FASD ) Relay Range : 30 - 50AmpPower Specs : 415 V + 15 % , 50 Hz + 3 %Qty: 02 NoM-POWER module for mobile starter IVRS language : English Type: 3 phase 3 wire Qty: 02 NoAmpere MeterSize: 96 mm sq ( 0 – 100 ) Amp Type : Digital 3 Ph LED Ammeter Class 1Qty: 02 NoVolt meter Size : 96 mm sq ( 0 – 600 ) V Type : Digital 3 Ph LED Voltmeter Class 1 Qty: 02 No Frequency meter Type : LED Freq meter Class 0.2 Qty: 01 NoNeon Indicators (RYB)Qty : 03NoBus Bars : Electrolytic Aluminium for 200 Amp Rating with proper tapping 7 P/I/T/Comm. of 50 KVA voltage stabilizer of following specifications:-a)Type:-Manually operated oil cooled b)Capacity:- 50 KVAc)No of phases:- 3 No of phases, 50 HZ frequencyd) Operating conditions:-1) Input 180 volts +10% to 440 volts+10% on 3 phase AC supply 2) Out put :- 440 volts + 10% 3 phase AC supplye) Terminals:- Three No incoming and three no outgoing terminals f) Core:- The voltage stabilizer shall be fitted with high permeability core for efficient heat dissipation and the core strips shall be held together firmly and fitted on bracket of suitable size and thicknessg) Coils:- Three no copper wound coils shall be fabricated out of suitable copper conductor with cotton tapping.h) Voltage regulator:- The voltage stabilizer shall be fitted with 6/8 steps three phase 200 amp stepping up voltage regulator double plate disc type having copper contact pointsi) Panel:- The indicating panel shall be fitted on the top side ofvoltage stabilizer fabricated out of suitable thickness MS sheetand fitted with volt meterand indication lamps.j) Meters :-Volt meters - Size : 96 mm sq - Type : Digital 3 Ph LED Voltmeter Class 1 Qty : 02 No with phase selecting optionk) Enclosure:- The whole assembly shall be enclosed in MS tank of suitable thickness, floor mounted . l) Coolant:-Thestabilizer shall be filled with A- gradeT – oil up torequired levelThe item shall be supported with test report/certificate from originalequipment manufacturer confirming to relevant IS codes. 8 P/F of 25 sq mm PVC insulated copper wire of reputed make for inters connections of electric gadgets. 9 P/F of copper thimbles of various sizes as per size requirement including crimping and taping. 10 Providing, fitting, testing and commissioning of XLPE Armoured Al. Cable of 1.1 KV grade with following characteristics: Conductor Nominal area : 50 mm2Min. Number of wires : 3 ½ To be fitted from change over panel to modular control panel 11 Providing, Fitting, Testing and Commissioning of Non Return Valve as per following specifications :Nominal Dia: 80 mmType : RETO – STOP Rating : PN 16Body : Ductile iron Corrosion protection – Epoxy CoatingEachvalve shall be provided with 02 no matching flanges 12 Providing, Fitting, Testing and Commissioning of Gate / Sluice Valve as per following specifications Nominal Dia: 80 mmType : EKO PLUS Rating : PN 16Body : Ductile iron Corrosion protection – Epoxy Coating Eachvalve shall be provided with 02 no matching flanges 13 Fabrication / Providing / Fitting of ( 80x80x80 ) mm TEE fabricated out of ( Class – B )GI pipe and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. 14 Supply, Installation and testing of 3 ton capacity motorized chain hoist with hook suspension along with monorail having following specifications:-Capacity=3 tonHoisting speed=2.4 M/MinHoist motor H.P=as per requirementNo. Of chain falls=4Min. Height of lift=6 MNote:-Alldescriptive datagiven above is approximate, intended to give general idea of the product. The equipment be supplied as per the latest parameters / specifications. The chain hoist shall also have the following characteristics:-1.Motor:- The basic drive of the hoist be provided with 3 phase squired cage totally enclosed induction motor having a high starting torque with class “F” insulation. The motor be reputed make and conform to IS : 325 (RPM-1500) 2.Brake:- The hoist shall have instant action, Fail to safe electromagnetic disc brake mounted on the end of the motor to ensure minimum safety and reliability when the load is held in its position as soon as the supply to the motor is switched off internally or accidentally. The adjustment & maintenance of break shall be quick and simple.3. Gears:- The hoist shall have precision cut super and helical gears made of alloy steel mounted on bearings and housed in a dust proof gear box. The lubrication of gears be of high viscosity and temperature for longer life of gears.4.Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation.5. Load chain wheel:-Specially designed, perfectly machined wheel providing correct grip of load chain made of malleable cast iron makes the hoist most safe and reliable against any failure. 6.Lifting Hook:-The lifting hook shall be forged with provision for free swiveling.7.Limit Switch :- The limit switch shall have snap action, shunt type prevent over hoisting or over lowering to ensure maximum safety of operation.8.Control:- The unit shall be controlled by heavy duty air break direction reversing type contractors and electrically inter – locked for safety. Contactors relay, fuses, low voltage transformer be fitted for control voltage and are to be housed in fabricated / pressed sheet steel box dust proof. 9. Push button pendent:- The contactors shall be operated by a pendent push button station suspended from hoist by a rope / dog chain to prevent any damage to the pendent cable and for easy operation.Test:-The hoist supplied is to be tested at 25% overload and the test certificate of the same be provided at the time of installation. The complete unit as specified above is required to be fitted / tested at site. 15 STAGE 2ND 16 Supply, installation, testing and commissioning ofopen well type Submersible pumping units of following specifications to be installed in the sump as per IS: 14220:1994 :-PUMP:-Discharge :- 4000 GPH Head:- 106 Mtrs Speed :2900 rpm Type of pump: Open well type submersibleImpelleras per IS code Quality of water to be handled:-clear Water The material of construction for pump, bearings, sleeves, casing, wear rings, pump shaft and suction casing shall suit to handle specifications detailed above.MOTOR Type :- open well Submersible Rating :Suitable for above parametersMethod of starting : Star Delta Speed: -2900 rpmVoltage :415 V + 15 % Class of Insulation : Suitable for above ratingThe submersible motor shall be squirrel cage induction type and the winding shall be wet type. The motor windings and bearing bushes of the rotary shall be cooled / lubricated by water. The unit shall be provided with name plate giving following details / information.Name of the manufacturer or trade markSerial No. Of the pump setTotal head and dischargeInduction motorFrequency in HzNumber of phasesRated out put in KW / HPRated voltage and including connectionsSpeed in revolutions per minute at rated outputApprox. current in Amps at rated outputThe pumping unit shall be provided with allied accessories / attachments viz. MS strengthening clamp, coupling nipple etc. one units to be installed in the sump and two to be kept as standby The item shall be supported with test certificate, performance characteristic curve and material of construction certificate from original Equipmentmanufacturer. 17 Supply/Fabrication and fitting of suitable size GI nipples for pumps. The nipples shall be threaded on one side as per outlet of pump and welded with suitable size MS flange as per the size of rising main 18 P/F of 16 sq. mm, submersible cable reputed make for open well submersible pumping equipment from pump house to sump. 19 Fabrication / Providing / Fitting and testing of Modular control panel of appropriate size fabricated out of 14 SWG steel sheet having required openings / vents and fitted with accessories as under :-Change over switch : Front operated / On load / 04 pole Rating: 200 Amp / 415 V + 15 % , 50 Hz + 3 % Quantity: One NoMain Circuit breaker : MCCB Thermal release range ( Amp ): 160 – 200 Breaking Capacity: Icu at 415 V AC, 50 HZ : 50 KA No of poles : 04Type: DN2 – 100N Qty : 01 NoCircuit Breaker on the input of starters : MCCB Thermal release range ( Amp ): 100 – 125 Breaking Capacity: Icu at 415 V AC, 50 HZ : 36 KA No of poles : 03Type: DN2 – 100D Qty : 02 NoStarter ( FASD ) Relay Range : 30 - 50AmpPower Specs : 415 V + 15 % , 50 Hz + 3 %Qty: 02 NoM-POWER module for mobile starter IVRS language : English Type: 3 phase 3 wire Qty: 02 NoAmpere MeterSize: 96 mm sq ( 0 – 100 ) Amp Type : Digital 3 Ph LED Ammeter Class 1Make : as per IS codeVolt meter Size : 96 mm sq ( 0 – 600 ) V Type : Digital 3 Ph LED Voltmeter Class 1 Qty: 02 No Frequency meter Type : LED Freq meter Class 0.2 Qty: 01 NoNeon Indicators (RYB)Qty : 03NoBus Bars : Electrolytic Aluminium for 200 Amp Rating with proper tapping 20 P/I/T/Comm. of 50 KVA voltage stabilizer of following specifications:-a)Type:-Manually operated oil cooled b)Capacity:- 50 KVAc)No of phases:- 3 No of phases, 50 HZ frequencyd) Operating conditions:-1) Input 180 volts +10% to 440 volts+10% on 3 phase AC supply 2) Out put :- 440 volts + 10% 3 phase AC supplye) Terminals:- Three No incoming and three no outgoing terminals f) Core:- The voltage stabilizer shall be fitted with high permeability core for efficient heat dissipation and the core strips shall be held together firmly and fitted on bracket of suitable size and thicknessg) Coils:- Three no copper wound coils shall be fabricated out of suitable copper conductor with cotton tapping.h) Voltage regulator:- The voltage stabilizer shall be fitted with 6/8 steps three phase 200 amp stepping up voltage regulator double plate disc type having copper contact pointsi) Panel:- The indicating panel shall be fitted on the top side ofvoltage stabilizer fabricated out of suitable thickness MS sheetand fitted with volt meterand indication lamps.j) Meters :-Volt meters - Size : 96 mm sq - Type : Digital 3 Ph LED Voltmeter Class 1 Qty : 02 No with phase selecting optionk) Enclosure:- The whole assembly shall be enclosed in MS tank of suitable thickness, floor mounted . l) Coolant:-Thestabilizer shall be filled with A- gradeT – oil up torequired levelThe item shall be supported with test report/certificate from originalequipment manufacturer confirming to relevant IS codes. 21 P/F of 25 sq mm PVC insulated copper wire of reputed make for inter connections of electric gadgets. 22 P/F of copper thimbles of various sizes as per size requirement including crimping and taping. 23 Providing, fitting, testing and commissioning of XLPE Armoured Al. Cable of 1.1 KV grade with following characteristics: Conductor Nominal area : 50 mm2Min. Number of wires : 3 ½ To be fitted from change over panel to modular panel 24 Supply / Laying and fitting of flanged GI rising main which is to be laidas per following specifications Nominal Dia: 80 mmClass of Pipe: BPipe Ends: FlangedFlange Standard: Table – 5 Flange thickness: 18 mmNo of holes: 4Bolting of Flange : M16Gasket : Fabric reinforced rubberAverage Trench size: 60 cm x 60 cm The job includes all the charges on account of flanges, bolts, gaskets, fabrication and welding work etc. the job also includes cutting of trenches, laying and fitting of pipes and backfilling of trenches. 25 Providing, Fitting, Testing and Commissioning of Non Return Valve as per following specifications :Nominal Dia: 80 mmType : RETO – STOP Rating : PN 16Body : Ductile iron Corrosion protection – Epoxy CoatingEachvalve shall be provided with 02 no matching flanges 26 Providing, Fitting, Testing and Commissioning of Gate / Sluice Valve as per following specifications Nominal Dia: 80 mmType : EKO PLUS Rating : PN 16Body : Ductile iron Corrosion protection – Epoxy CoatingEachvalve shall be provided with 02 no matching flanges 27 P/F of Air Release valve as per following specifications Size: DN 25Type : Automatic Operation : Single chamber air valve, MOC: Floatof stainless steel, Body & Cover Ductile ironCoating : Inside and outside of epoxy coating. The job includes p/f of suitable sizeG.I. Tee, G.I nipple. The item shall be supported with test certificate from original manufacturer 28 Providing and fitting of90080 mm dia G.I. long radius bends / offsetsmade out of ( Class – B )GI pipe and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joint. 29 Fabrication / Providing / Fitting of ( 80 x 80 x 80 ) mm TEE fabricated out of ( Class – B )GI pipe and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. 30 Fabrication / Erection of channel iron column to act as support for monorail crane as per following specifications :-Vertical posts ISMC – 150 Posts 02 No = 6.0 m x 2 x 2 = 24 m @ 16.4 Kg / m = 393.6 kgIntermediate / middle post for extra support to be fitted on top of sump. 02 No channel sections to be welded face to face to form square section )= 4.5 m x 2= 9 m @ 16.4 Kg / m = 147.6 kgISMC – 75 for bracing = 0.35 m x 24 x 2 = 16.84 m @ 6.9 kg / m =115.9 kgPlate -12 mm thick = 0. 45 m x 0.3 m x 9 No( 06 No for posts and 03 No. for beam)= 1.2 m2= 114.4 kgThe job includes drilling of suitable size 04 no holes to each plate for accommodating boltsMonorail ISMB – 200 =9 m @ 25.4 kg / m = 228.6 kgNuts and Bolts and washers assorted incl foundation bolts 6/8 “ x 2’ each – 08 No = 20 kg ( L/S)Total wt. for gantry = 1020.1 kgs 31 COMMON FOR BOTH STAGES 32 A) HT DISTRIBUTION TRANSFORMERP/I/T/Commissioning oflevel-2 (L-2) 100 KVA 3 phase and neutral distribution transformer of following specifications and details as per IS 1180 (Part 1) of 2014 :-A) Type:- Distribution transformer, naturally aspirated, oil cooledB) Capacity:-100 KVAC) Operating Conditions1) Input:-11000 Volts 2 ) Output:-440 Volt AC supply, 3 phaseD) Terminals 1)Input: - 3 No. HT bush rods with insulators, washers, nuts etc. 2) Output:- 4 No. LT bush rods with insulators, washers, nuts etcE)Core:- High permeability core for heat dissipation, fabricated out of suitable size and gauge strips.F) Transformer Coils:- Suitable no. of HT& LT coils in each leg. The transformer coils shall be fabricated out of superior quality aluminium wire/ strips properly wound.G) Coolant:- The HT transformer shall be completely filledwith “A” grade transformer oil up to required level.H) Enclosure: - The core, coils, brackets shall be enclosed in MS tank of suitable thickness with cooling conduits /fins on either side. The MS tank shall be painted in to two coats of enamel synthetic paint and the tank shall be fitted with drain plug and oil level indicator.Besides above the whole assembly is to be carried to sight and includes carriages, head loads, all leads and lifts. 33 B) Providing/Erection of 9 Mtr long M S Tubular poles (410 SP - 33) having reducing dia of 6’’ x 5’’x 4’’ from bottom to top.The pole shall be 164 kgs in weight. The job shall also be inclusive of concrete bottoming of poles, painting in silver colour and P/F of Danger plates. 34 P/F of guy wire with insulator, anchoring rod and turn buckle. 35 P/F of 8’ long ISMC 100 channels for transformer bed complete with nuts and bolts 36 P/F of 8’ long ISMC 75 channels complete with nuts and bolts for fitment of link set, D/O set & lightening arrestor set etc. 37 F) P/F 3 phase heavy duty link set with copper grips. ( G.O. Switch ) suitable for 11 KVA reputed make 38 G) P/F 3 phase heavy duty drop out set suitable for 11 KVA reputed make 39 H) P/F of lightening arrestor set ( Station type ) 40 I) P/Fitting of 50 sq mm ABC (Aerial bunched cable) conductor for 11 KV power transmission. 41 J) P/F of 11 KV cable terminating cable kits for above cable 42 L) P/F of the arrangement (Belt) to hold the transformer firmly and securely to the substation. It is to be fabricated out of ISA(40x40x5)mm C/w nuts & bolts 43 M) Providing, Installation of earthing station comprising of company fabricated earthing electrodes as per IS: 3043. The job includes Auguring of bore of required dia / depth for installation of electrode along with black fill compound mixed with soil and all other items required thereof for achieving the best result The job includes P/F ofGI strip shall be fitted on baby insulators and clamps. Safe earthing electrode size 50 mm dialength - 1500mmBackfill - 30 Kg 44 Providing/Erection of 9 Mtr long M S Tubular poles (410 SP - 33) having reducing dia of 6’’ x 5’’x 4’’ from bottom to top.The job shall also be inclusive of concrete bottoming of poles, painting in silver colour and P/F of Danger plates. Along with strip/GI earthing. The job also includes providing and fitting of Pin insulators and cross arms as per the requirements. 45 Supply installation testing and commissioning of .05 ACSR conductor form taping point to substation. 46 Supply, Installation, Testing & Commissioning of 62.5 KVA – 3 Phase air cooled D.G. Set. The DG set shall be suitable for 1600m-AMSL altitude, -100C to +400C temperature and 60% relative humidity. The DG Set shall comprise of diesel engine and alternator coupled together and fitted with standard accessories, control panel, battery, anti vibration pads, MS canopy duly painted and conforming to noise pollution specifications. The DG Set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in twelve hours. The DG set shall comprise ofA)ALTERNATOR The alternator shall be self excited. Self regulated for desired rating. The alternator shall be fitted with high performance AVR and suitable for continuous and trouble free operation.SPECIFICATIONS1)Rated Output at above Site Conditions :- 62.5KVA 2)Rated Speed :- 1500 rpm 3) Efficiency:-88.8%4) Voltage:- 415 V at 50 Hz B)DIESEL ENGINE (Prime Mover)The engine shall be diesel driven to develop requisite BHP at 1500 rpm for the alternator rated as above at an altitude of 1600m AMSL with ambient temperature ranging from 100C to +400C under 60% humid conditions. Specifications:- 1) Speed:- 1500rpm2) No. of cylinders :- 063) Aspiration:- TC4)Cooling system;-Aircooled 5) Method of start: - 12 volt electric start.The engine shall be fitted with following accessories. 1) Fuel tank:-suitable capability for twelve hours continuous running on full load. The fuel tank shall be floor mounted type made of M.S sheet duly painted and fitted with inlet/outlet return connections, air vent, drain valve, level indicator and fuel pipes 2) Safety control: - In order to shut down the engine in the event of high water temperature. It shall also be fitted with ant vibration pads, cold starting aid, safety control for low lube pressure etc. 5) Radiator:- Suitable Size C/W hoses, clamps etc.C) Standard control pannel:- It shall be fabricated out of steel sheet 1.5mm thick duly pretreated and Aesthetically finished. It shall be totally enclosed, dust, vermin proof with IP-53 degree of protection as per IS 2147-62. The panel shall consist of following instruments.1) (0-600) V -AC Voltmeter of class 1.5 accuracy with phase selector switch. 2) AC- Ammeter of class 1.5 accuracy.3) HRC fuses of suitable rating.4) One No. MCCB/MCB of suitable rating 5) Pilot lamps6) Push button switch for ON-OFF operation.7) It shall also be fitted with starting switch with keys, Lube oil gauge, Temp. and pressure gauge, Speedometer and hour meter etc.All the above components shall be properly mounted duly wired and shall be of reputed make.D) Canopy:- M.S. Canopy of suitable thickness, duly painted, able to withstand snow load and able to control noise pollution, is to be fitted to the D.G. Set.E) First Filling Of HSD:-The DG set shall be provided with first filling of HSD. The fuel tank shall be filled with 60 ltrsE) Miscellaneous:-Technical literature and catalogue is to be provided. The job includes earthing of DG set as per norms and site conditions & requisite cables etc for inter connection to commission the DG set.The item shall be supported with test report/certificate from originalequipment manufacturer confirming to relevant IS codes. 47 Providing and Fitting of 50 mm dia flexible canvas sleeve / conduit for carrying conductor. 48 Supply, installation and testing of 02 ton capacity, manually operated chain pulley block of reputed make. The chain pulley block shall have 6 m lift. It shall also include suspension arrangement made of 10 mm steel wire rope or GI wire capable of supporting rated load and 2 No. D-Shackles (with nut locking system) for fitment of chain with suitable size. 49 Supply and erection of 9 mtr long hot dip galvanized octagonal pole( Single Section ) with bottom 155 mm, top 65mm, thickness 3 mm with Zinc coating with inside arrangement for providing of power connection with following items:02 No terminal connector 60 AmpRequired size duly crimped lugs04 No foundation bolts of required size and length with nutsCement concreting of required size but not less than (50 x 50 x 100) cm in 1 : 2 : 4 ratiorequired length 1.5 sq mm multi strandPVC insulated copper conductorMounting arrangement for fixing flood lightsService line from panel to pole in 2.5 sq mm multi strandPVC insulated copper conductor to be laid underground through alkathine sleeve – Length as per site requirement 50 Supply, Installation, Testing and commissioning of pressure die cast aluminium integral LED flood lights as per specifications below :Rating – 48 W 51 Providing, Fabrication and fitting of suitable fixture capable of supporting 3 lights. It must be suitable for pole mounting and fabricated out of suitable size pipe. 52 Supply and installation of 1000 VA reputed make inverter for charging battery of DG set installed at water supply scheme. The job also includes supply of 12 V - 180 Ah reputed made battery complete with leads, terminals and thimbles. The job includes all the charges on account of carriages, wiring and arrangement of skilled labour for installation of inverter. The job includes demonstration of the use of inverter and testing at site. The job also includes wiring switches and sockets etc. 53 Electrification of Pump House by way of P/F of:-Lighting points in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures. – 08 jobsLighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – 06 jobsHeating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp.SS combine- 04 jobs5-pin socket points in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- 04 jobsIndicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – 04 jobsCeiling Fan make c/w regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – 02 jobs Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -04 No for lighting points and 2/3 pin socket points and fans, 10 A – 02 No for flood lights, 16 Amp – 02 No for heating points, 63 Amp MCB ( Mains ) – reputed make. 05KW sine wave voltage stabilizer single phase 90 – 270 V input for a constant output of 240 VThe fittings shall be modular type and of reputed make 54 The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below & shall be of reputed make:Flat Spannerof Size (4/5 to 30/32) :(01 complete set)Ring Spanner Set of Size (12/13to 30/32) :(01 complete set)Cutting Pliers, 10 inch: (01 No)Cutting Pliers, 12 inch: (01 No)Nose Pliers 9 inch: (01 No)Rechargeable torch : (02 No) Multimeter reputed make : ( 01 No)Screw Driver 18 inch /12 inch / 9 Inch:( 02 No`s Each )Hammer, 1 Kg, 2 kg : (01 No each)Pipe Wrench 12 inch / 18 inch / 24 inch : (01 No each ) Bamboo Ladder (20 feet) : (01 No)11 KVA Shock Proof Rubber Gloves: (02 pairs)Bamboo type Link Rod : (01 No)The tools are to be provided in a strong tool box with key and lock. 55 Supply of basic facilities to the staff comprising of:Matting comprising of 12 mm thermo cool, jute matting/ excel, floor blankets – 150 sft eachBedding comprising of mattress, quilt, excel blanket, pillow – 03 sets.Cooking and bathroom items as 4 ltr pressure cooker, 2.8 ltr rice cooker, pan, aluminum cooking vessels – 02 No, steel plates – 04 No, Steel glass ( tumblers) – 04 No, cooking spoons – 02 No, Cups – 04 no, Plastic Jug, Electric heater, Kerosene stove, 20 ltr plastic buckets – 02 No, 1 ltr plastic mugs – 02 No, Heavy duty plastic chairs -04 No and table 01 No 9 Prima / Cello / reputed make)Chargeable lantern reputed make – 01 No, Gas stove with domestic gas cylinder – 14 kg capacity complete with gas pipe and regulator and papersHeat convector / Heating Blower – 01 No 56 P/Fab of retiring bed for operational staff. The bed is to be fabricated out of ISA (50x50x6) mm. the bed should be 6 feet long, 4 feet wide and 1.25 feet high. Also 03 No. supports fabricated out of 25x5mm MS strips shall be provided and welded to support 19 mm thick ply board to be fitted on top. 57 Providing/ Mountingof 4.5 Kg carbon dioxide fire extinguishers conforming to IS: 2878, suitable and effective for controlling electric, machinery and oil generated fires (B C class of fires ). The fire extinguishers to have a suitable hose pipe of sufficient length. The job includes mounting the fire extinguishers on the walls conveniently in the vicinity of machinery by way of fixing the MS clamps and angle iron of suitable size on the walls. 58 Painting of gantry, pipe network( inside the premises of pump house), and shed incl. all the metal surfaces except CGI sheeting and purlins by applying a coat of anticorrosive (Red Oxide) and then two coats of synthetic enamel paint. 59 Providing/laying of 3mm thick high density anti skid rubber floor mating on the machine floor level area 60 Providing of 25 mm thick shock proof rubber mats each of size 1 m x 2 m 61 Operation and Maintenance charges of all the electro-mechanical equipments for a period of 03 years from the date of commissioning of the scheme.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Dec-2021 CORRIGENDUM-1 Technical Bid 15-12-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 201000.0 /-
Tender Value
INR 67 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail